Instruction Sheet
408-32029
Removal Tool Kit 2161844-1
09 OCT 12 Rev B
Removal Screw
Removal Tool
Top Plate of Removal Tool
QUADRA* Cage
Assembly (Typ)
Support Tool of
Removal Tool
PC Board
Side Plate of
Removal Tool
Figure 1
1. INTRODUCTION
4. REMOVAL (Figure 2)
Removal Tool Kits 2161844-1 are used to remove the
QUADRA* cage assembly from a host printed circuit
(pc) board. The cage assemblies contain press fit
contacts to allow solderless pc board installation.
Read these instructions thoroughly before using the
removal tool.
1. Place the pc board on a flat surface.
2. Insert the support tool into the cage assembly
until it contacts the stops.
2. DESCRIPTION
Each removal tool kit consists of a top plate, three side
plates, a removal screw, and a support tool. The
support tool is inserted into the cage assembly during
removal. The removal screw draws the support tool
away from the printed circuit board while the side
plates push against the pc board. As the support tool
is drawn away from the pc board, the Quadra cage
assembly is removed.
3. SETUP
When setting up equipment to remove the cage
assembly, pay particular attention to the following:
• The removal tool must be matched to the cage
assembly.
• The support tool must be properly installed, and
the removal tool must be properly aligned before
removing the cage assembly.
© 2012 Tyco Electronics Corporation, a TE Connectivity Ltd. Company
All Rights Reserved
*Trademark
CAUTION Be certain the removal tool assembly does not
contact any components on the PC board during
use.
!
3. Place the removal tool over the cage assembly
and align the hole in the removal tool to the hole in
the support tool.
4. Insert the M12 screw into the hole in the removal
tool and turn clockwise by hand to start the threads.
5. With the proper size hex wrench, (not supplied)
turn the screw clockwise until the cage assembly is
free from the pc board.
6. Remove the support tool and cage assembly
from the removal tool by turning the screw counter
clockwise until the cage and support fixture are free
from the removal tool.
7. Discard the cage assembly. It is not designed to
be reused.
8. Check the pc board for damage to cage mounting
holes, surface traces, and components.
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product and/or Company names may be trademarks of their respective owners.
1 of 2
LOC B
408-32029
Figure 2
5. MAINTENANCE AND INSPECTION
6. REPLACEMENT AND REPAIR
TE Connectivity recommends that the tool be
inspected immediately upon its arrival to ensure that it
has not been damaged during shipment.
Order tools through your TE Representative, or call 1800-526-5142, or send a facsimile of your purchase
order to 717-986-7605. or write to:
5.1. Daily Maintenance
It is recommended that each operator be made aware
of, and responsible for, the following steps of daily
maintenance:
CUSTOMER SERVICE (038-035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105-3608
• Remove dust, moisture, and other contaminants
7. REVISION SUMMARY
with a clean, soft brush, or lint-free cloth. DO NOT
use objects that could damage the tool or any of its
components.
• When the tool is not in use, store it in a clean, dry
area.
Since the previous release, Figure 1 and Figure 2
were revised.
5.2. Periodic Inspection
Regular inspections should be performed by quality
control personnel. A record of scheduled inspections
should remain with the tool or be supplied to personnel
responsible for the tool. The inspection frequency
should be based on the amount of use, working
conditions, operator training and skill, and established
company standards.