GENERAL PURPOSE RELAY
TYPE 258
FEATURES:
• Contact rating up to 15A@240V resistive load.
• UL/CSA/TUV approved.
• AC & DC coils available.
• PCB terminal and socket type.
CONTACT RATING
CSA
UL
Resistive Load
TUV
15A/28VDC
15A/28VDC
15A/250VAC, 15A/30VDC
Motor
1/2HP, 120VAC
1/2 HP, 120VAC
6.2A/120VAC, Cos ø 0.5
Gen. use
15A/240VAC
10A/240VAC, 15A/120VAC
COIL DATA (DC)
Rated Voltage
( VDC)
Rated Current
±10% at 25°C
(mA)
Coil Resistance
±10% at 25°C
W)
(W
Max. Continuous
Voltage at 25°C
Pickup Voltage
(Max) at 25°C
Dropout Voltage
(Min) at 25°C
Power
Consumption
at Rated Voltage
6
12
24
48
110
150
75
37
19
10
40
160
650
2600
11000
110% of
rated voltage
75% of
rated voltage
10% of
rated voltage
Approx. 0.9 W
COIL DATA (AC)
Rated Voltage
(VAC)
Coil Resistance
W)
±10% at 25°C (W
Max. Continuous
Voltage at 25°C
Pickup Voltage
(Max) at 25°C
Dropout Voltage
(Min) at 25°C
Power
Consumption
at Rated Voltage
12
24
120
240
40
160
3400
13600
110% of
rated voltage
85% of
rated voltage
30% of
rated voltage
approx. 1.2 VA
PART NUMBERING SYSTEM
Relay Type
258
Enclosure & Terminals
1–Dust Cover/Solder Lug
2–Dust Cover PCB
6–Flanged Cover/Solder Lug
Contact Form
Coil Voltage
Contact Material & Ratings
1–SPDT
4–SPST, NO
5–SPST, NC
2–DPDT
6–DPST, NO
(For Enclosures
1&6)
A–6VDC
B–12VDC
C–24VDC
D–48VDC
F–110VDC
P–12VAC
Q–24VAC
T–120VAC
U–240VAC
2–Standard, Ag Cd0
Standard or Special
00–Standard
C0–Standard
LC–Lamp & Push Button
L0–Lamp Across Coil
(For Enclosure 1 only & for DPDT
only)
A1-Z9–Special
Example: 258-11A200
Stock Item: 258-12B200, 258-12C200, 258-12T200, 258-12Q200, 258-22B200, 258-22C200, 258-22T200, 258-22Q200, 258-62B200,
258-62C200, 258-62T200, 258-62Q200.
36
Libertyville IL (847) 680-7400 FAX (847) 680-8169
www.ciitech.com
TYPE 258
SPECIFICATIONS
Contact resistance
Operate time
Release time
Insulation resistance
Dielectric strength @25°C
Vibration resistance
Shock resistance
Life expectancy for mechanical
Life expectancy for electrical
Operating temperature
Weight
30 m Max. (initial value)
25 mS Max.
25 mS Max.
100 M Min. (DC 500V)
Between open contact: AC 500 V 50/60 Hz 1 minute.
Between contact and coil: AC 1500 V 50/60 Hz 1 minute.
Between live parts & ground: AC 1500 V 50/60 Hz 1 minute.
Damage limits & Operating extremes: 10~55 Hz, amplitude 1.0 mm
Damage limits: 100g, Operating extremes: 20g
10,000,000 operations (frequency 18,000 operations/hr)
100,000 operations (frequency 1,800 operations/hr)
-25~+55°C (no freezing)
Approx. 32g
DIMENSIONS
Inches
(Millimeters)
WIRING
SPST, NO
SPST, NC
Libertyville IL (847) 680-7400 FAX (847) 680-8169
Reference Only
www.ciitech.com
SPDT
37
TYPE 258
PCB LAYOUT
Bottom View
Reference Only
Inches
(Millimeters)
CURVES
Life Expectancy
Operate Time/Release Time
Coil Temp. Rise Above Ambient
SAFETY APPROVAL
FILE NO.
CERTIFIED
38
UL
E38802
CSA
LR700557
TUV
9452081
Libertyville IL (847) 680-7400 FAX (847) 680-8169
www.ciitech.com
很抱歉,暂时无法提供与“25812U200”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 4+278.31069
- 17+266.70333
- 34+256.05116
- 166+245.78590
- 497+235.52064
- 国内价格
- 4+400.55675
- 17+383.85083
- 34+368.52464
- 166+353.74537
- 497+338.97853