3-1393249-8

3-1393249-8

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
3-1393249-8 数据手册
W58 series Push To Reset Only Thermal Circuit Breaker Maximum Resistance vs. Current Rating @ +25°C Features • 0.5 amp to 30 amp ratings. • Cannot be manually tripped. • Button extends for visual trip indication. • Push button to reset breaker. • Termination is screw or .250” QC. Current Rating in Amps 0.5 1 2 3 4 5 6 7 Agency Approvals W58 Series is UL 1077 Recognized as Supplementary Protectors, File E69543, and CSA Certified as Appliance Component Protectors, File LR15734. Maximum Resistance in Ohms 5.0 1.35 0.32 0.18 0.10 0.026 0.026 0.020 Current Rating in Amps 8 9 10 12 15 20 25 30 Maximum Resistance in Ohms 0.020 0.020 0.014 0.010 0.010 0.005 0.006 0.004 Electrical Data @ +25°C Calibration: Breaker will continuously carry 100% of rated load. It may trip between 101% and 145% of rated load, but must trip at 145% at 25°C. Dielectric Strength: Over 1,500 volts RMS. Maximum Operating Voltages: 50VDC; 250VAC. Interrupt Capacity: 2,000 amps at 50VDC (0.5 - 30 amp models). 1,000 amps at 250VAC (0.5 - 30 amp models). Note: 30 0amp model not UL or CSA. Resettable Overload Capacity: Ten times rated current. Mechanical/Environmental Data Shock: Withstands to 10g. Endurance Cycling: Over 1,000 cycles at 200% of rated load. Vibration: Withstands to 10g at 10-55 Hz. Weight: Less than 1 1/2 oz. (42.5g). Time vs. Current Trip Curve @ +25°C Ambient Compensation Chart 1000 Load Current As A Percent Of Breaker Rating 800 Overload 100% 145% 200% 400% 600% 800% 1000% (A) 700 600 Trip Times Overload No Trip Trip in 1 hour 6.0-30 Sec. 1.6-4.5 Sec. 0.60-1.7 Sec. 0.25-0.90 Sec. 0.15-0.65 Sec. 100% 145% 200% 400% 600% 800% 1000% Trip Times No Trip Trip in 1 hour 10-45 Sec. 3.0-14.0 Sec. 1.4-7.0 Sec. 0.75-4.3 Sec. 0.50-3.4 Sec. 500 (B) 400 1.40 (B) All 1-4 Amp Models 1.30 Correction Factor (A) All 5-30 Amp Models 900 1.20 1.10 1.00 0.90 0.80 0.70 300 0.60 200 0 10 20 30 40 50 60 Ambient Temperature In Degrees Centigrade (°C) 100 0 .1 –20 –10 1 10 Time In Seconds 100 1000 To use this chart: Read up from the ambient temperature to the curve, and across to find a correction factor. Multiply the breaker rating by the correction factor to determine the compensated rating. Calculate the overloads in terms of the compensated rating to use the published trip curve. Tyco Electronics 700 Westpark Drive Peachtree City, GA. 30269-1498 Specifications and availability subject to change without notice. 13C9580 Printed in U.S.A. IH2-00 Ordering Information Typical Part No. B W 58 -X B 1 A 4 A 1. Designator: W = Circuit breaker 2. Series Number: 58 = Single Pole, Push-to-Reset 3. Circuit Function: X = Series Trip 4. Button: A = White, plain, no rate marking, no trip band B = White with red rate marking, red trip band C = White with black rate marking, red trip band E = White with red rate marking no trip band F = White with black rate marking, no trip band 5. Mounting Bushing: 1 = 7/16” x .500” (12.70mm) long 4 = 15/32” x .300” (7.62mm) long, black 6 = 3/8” x .465” (11.81mm) long, round 6. Terminals: A = Quick connect .250” (6.35mm) straight C = 6/32 screw 90° (screws installed) D = 6/32 screw 90° (screws bulk packed) 7. Mounting Hardware: 4 = Knurled nut/hex nut 6 = Knurled nut/hex nut/lock washer 12 = Knurled nut/lock washer 15 = Two hex nuts/lock washer 99 = No mtg. hardware supplied (Use C, Step #8) Note: For other hardware combinations, order separately. See mounting hardware Ordering Information table. 8. Mounting Hardware Packaging: A = Assembled to bushing B = Bulk unassembled C = No mounting hardware 9. Specify Amp Rating: 0.5 3 6 1 4 7 2 5 8 9 10 12 15 20 25 30* *Not UL or CSA Stock Items – We recommend that our authorized distributors stock the following items for immediate delivery. W58-XB1A4A-1 W58-XB1A4A-2 W58-XB1A4A-3 W58-XB1A4A-4 W58-XB1A4A-5 W58-XB1A4A-6 W58-XB1A4A-7 W58-XB1A4A-8 W58-XB1A4A-10 W58-XB1A4A-12 W58-XC4C12A-2 W58-XC4C12A-3 W58-XC4C12A-5 W58-XC4C12A-7 W58-XC4C12A-10 W58-XB1A4A-15 W58-XB1A4A-20 W58-XB1A4A-25 W58-XB1A4A-30 W58-XC4C12A-1 W58-XC4C12A-15 W58-XC4C12A-20 W58-XC4C12A-25 W58-XC4C12A-30 Outline Dimensions Terminal Options .440 (11.18) .425 .850 (10.80) (21.59) 1.375 (34.93) .250 (6.35) x .032 (.81) QUICK CONNECT TERMINALS .050 MAX. (1.27) CLOSED POSITION .415 (10.54) CODES 1 & 4 .312±.005 (7.92±.13) 1.375 (34.93) 15 .250 (6.35) CODE 6 SEE TERMINAL DRAWINGS SEE MOUNTING FOR DETAIL BUSHING AND MOUNTING HARDWARE DRAWINGS FOR DETAIL .660 (16.76) 1.375 (34.93) .850 (21.59) A .440 (11.18) .187 (4.75) .281 MAX. (7.14) OPEN POSITION BUTTON .425 (10.80) .312 TYP. (7.92) C&D .156 .85 (3.96) (21.6) #6-32 SCREW & LOCK WASHER ASSEMBLY -5 Mounting Hardware Disc Knurled Nut Hex Nut Pal Nut Lockwasher ALTERNATE TEETH TWISTED IN OPPOSITE DIRECTIONS STRAIGHT KNURL 24 PITCH IT BREAK CU ER CIR BLACK ETCHED LETTERS .078 (1.98) HIGH, BOLD FACE PR ES FLAT A A ET A S TO RES .937 (23.80) B .013 (.33) A B Mounting Bushing B B Mounting Hardware Dimensions Type 1 Recommended Cutout .440 - .450 DIA. (17.3 - 17.7) 7/16-28 THREAD (SILVER) A. B. Dim. Hex. Knurled L/W Pal 3/8” .556 .562 .562 .562 7/16” .625 .625 .540 .625 15/32” .556 .625 .600 .625 3/8” .085 .078 .018 .140 7/16” .078 .125 .022 .111 15/32” .078 .125 .018 .090 Type 4 .300 (7.62) Mounting Hardware Ordering Information .470 - .480 DIA. (18.5 - 18.9) 15/32-32 THREAD (BLACK) Type 6 Mounting Bushing Code Knurl Nut Hex Nut Pal Nut Washer Push to Reset Disc 1 55-010A 55-011A 16S086B 88-021B 33-012A 4 • 55-001B 16S086C 88-002A 33-012C 6 55-008A 55-001D 16S086A 88-006K 33-012B • 55-010B (silver) 55-010E (black) .465 (11.81) .370 - .380 DIA. (15.0 - 15.3) 3/8-24 THREAD (SILVER) Tyco Electronics 700 Westpark Drive Peachtree City, GA. 30269-1498 Specifications and availability subject to change without notice. 13C9580 Printed in U.S.A. IH/2-00
3-1393249-8 价格&库存

很抱歉,暂时无法提供与“3-1393249-8”相匹配的价格&库存,您可以联系我们找货

免费人工找货