Signal Relays
AXICOM
Cradle S Relay V23054/V23062
n Strong
magnet system and wide voltage range
reliable
n Contacts for signal loads and currents up to 5A
n DC coils operating voltage 6VDC to 220VDC; AC, latching and nonlatching coils on request
n Multi purpose relay
n Great variety of contact arrangements and materials to meet
specific applications
n Sockets for easy and quick mounting of relays
n Highly
Typical applications
Press controls with high safety requirements (forcibly guided springs),
traffic and railroad signalling, motor vehicle traffic controls, power plants
and nuclear power plants controls
Contact Data
Product code block 3
B104/B110/
B604/B610/
C104/C110/
C404/C410/
F104/F105/
B112/B133
B612/B633
C112/C133
C422/C433
F110
Contact arrangement
max. 6 form C (6 CO) contacts or 6 form A (6 NO) contacts (see product code table)
Max. switching voltage
150VDC 36VDC 150VDC 36VDC 260VDC
125VAC 30VAC 125VAC 30VAC 250VAC
Rated current
2A 0.2A 2A 0.2A 5A
Limiting continuous current
at max. ambient temperature
2A 2A 2A 2A 5A
Breaking capacity max.
35 to 70W
5W, 5VA
35 to 70W
5W, 5VA
50 to 140W
see DC load breaking capacity curve below 50VA
-
50VA
-
500VA
Contact material silver, gold-flashed
gold F
silver, gold-flashed
gold F
silver, gold-flashed
Contact style
single contact
single contact
bifurcated contacts
bifurcated contacts
single contact
Frequency of operation, without load, max. 50 ops./s
max. 50 ops./s
max. 50 ops./s
max. 50 ops./s
max. 10 ops./s
Operate / release time typ.
16/2ms
16/2ms
16/2ms
16/2ms
16/2ms
Mechanical endurance
app. 107 ops.
app. 107 ops.
app. 107 ops.
app. 107 ops.
app. 107 ops.
Max. DC breaking capacity, contact sets B1xx, C1xx
Max. DC breaking capacity, contact sets F1xx
150
250
V_
V_
200
120
140 W
U
U
70 W
150
100
100 W
100
80
80
60
50
50
safe breaking, no stationary arc
contact material Ag, gold flashed
40
DC voltage [VDC]
DC voltage [VDC]
60
40 W
30
0,3
0,4
0,5
0,6
0,8
1
DC current [A]
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
1,5
I
2A
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
40
safe breaking, no stationary arc
contact material Ag, gold flashed
50 W
30
20
0,2
0,3
0,4
0,5
0,6
0,8
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
1
1,5
2
3
DC current [A] I
4
5A
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
Signal Relays
AXICOM
Cradle S Relay V23054/V23062 (Continued)
Coil Data
Magnetic system
neutral
Coil voltage range
6 to 220 VDC,
1000 - 2000mW power consumption
Max. coil temperature
100 °C
Thermal resistance
< 40K/W
Coil versions, DC coil, monostable
Coil
Rated
Operate/Limiting
Coil
Rated coil
code
voltage
voltage1) resistance power
VDC
VDC
Ω ± 10%
mW
011
6
-
33
1091
012
8.4
-
70
1008
015
12
-
130
1108
016
12.5
-
185
845
017
16
-
270
948
019
20
-
390
1026
020
24
-
630
914
002
1.2
-
1.75
823
025
28
-
800
980
046
29
-
890
945
021
32
-
1050
975
022
45
-
1900
1066
026
60
-
3800
947
014
76
-
5800
996
004
110
-
9200
1315
013
125
-
15500
1008
003
220
-
25000
1936
Insulation Data
B1xx,B6xx,C1xx,C4xx F1xx
Initial surge withstand voltage
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance, at 500VDC
500Vrms 500Vrms
500Vrms 1000Vrms
500Vrms 1000Vrms
> 106Ω
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-40 to +70°C
Category of environmental protection
IEC 61810
RT I - dust protected,
RT V - hermetically sealed
Degree of protection, IEC 60529
dust-protected IP 30,
or hermetically sealed IP 67
Terminal type
PCB, solder terminals
Weight
V23054 Size I
approx. 20g
V23054 Size II
approx. 25g
V23054Size III
approx. 27g
V23062 Size I
approx. 30g
V23062 Size II
approx. 35g
Washing
not recommended
Ultrasonic cleaning
not recommended
Packaging unit
5 pcs.
1) See part code table.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Accessories
For details see datasheet
Cradle Relay, Accessories and Mounting
Terminals:
coil with 1 winding: start 4, end 1
coil with 2 windings (upon request):
start 3, end 2 for winding I, start 4, end 1 for winding II
The minimum voltage UI depends on the contact set and the ambient
temperature, the maximum voltage UII only depends on the ambient
temperature.
Between minimum voltage UI tamb and operating voltage U a safety margin
of approx. 20% is recommended.
UI tamb (1.2) < UI ≤ UII tamb
UI tamb
UI · U20 °C · kI tamb
UII tamb UIl 20 °C · kII tamb
tamb
Ambient temperature
U
Operating voltage
UI tamb
Minimum voltage at ambient temperature, tamb
UII tamb
Maximum voltage at ambient temperature, tamb
kI and kII Factors
2
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Signal Relays
AXICOM
Cradle S Relay V23054/V23062 (Continued)
Terminal assignment
Size I
2 form C (2 CO)
V230xx-xxxxx-Bx04
V230xx-xxxxx-Cx04
Size II
2 form A (2 NO)
V230xx-xxxxx-F105
6 form A (6 NO)
V230xx-xxxxx-Bx12
V230xx-xxxxx-Cx12
4 form C (4 CO)
V230xx-xxxxx-Bx10
V230xx-xxxxx-Cx10
2 form C (2 CO)
V230xx-xxxxx-F104
Size III
6 form C (6 CO)
V230xx-xxxxx-Bx33
V230xx-xxxxx-Cx33
4 form C (4 CO)
V230xx-xxxxx-F110
Dimensions
V23054-Cxxx, size I type
V23054-Dxxx, size II type
V23054-Exxx, size I type
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
3
Signal Relays
AXICOM
Cradle S Relay V23054/V23062 (Continued)
Dimensions
V23062-Axxx, size I type
V23062-Bxxx, size II type
Instructions for Impulse Operation
The maximum voltage stated in the part code table can be increased for
impulse operation as follows:
UII Impuls UII tambxq
UII tamb Maximum continuous voltage at ambient temperature tamb
q
Factor
The impulse voltage must not exceed 80% of the test voltage (winding/
frame or winding/winding) or 2.5 times the value of the maximum voltage
listed in the part code table.
; IftED = Pulse width, t2 = Cycle time. If tED > 3s the
IftED ≤ 3s then q=
value of q must be obtained from the nomograph.
Examples of various periodic pulse trains (energizing side)
1. Periodic recurrence of one energizing pulse
2. Periodic recurrence of two unequal energizing pulses
tED = tI + tII
tI + tII = Pulse widths
within one cycle
4
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Signal Relays
AXICOM
Cradle S Relay V23054/V23062 (Continued)
Product code structure
Typical product code V23054 -D 0 021 -B1 10
Type
V23054 Cradle S Relay, dust protected
V23062 Cradle S Relay, hermetically sealed
Size
V23054 types
C
Size I, dust-protected
D
Size II, dust-protected
E
Size III, dust-protected
V23062 types
A
Size I, hermetically sealed
B
Size II, hermetically sealed
Version
0
Standard version
1
Fitted with contact pile-ups F
2
For higher test voltage of 2kV coil/frame
3
Combination of 1 & 2 (contact pile-ups F and higher test voltage coil/frame)
Coils
Coil code: please refer to coil versions table
Contact style
B1 Single contacts
B6 Single contacts
F1 Single contacts
C1 Bifurcated contacts
C4 Bifurcated contacts
Contact arrangement
04 2 form C, 2 CO
05 2 form A, 1 NO
10 4 form C, 4 CO
12 6 form A, 6 NO
33 6 form C, 6 CO
Other types on request
Product code
Version
V23054-CXXXX, standard, size I
V23054-C0013-B104 Standard, size I
V23054-C0015-B104 Standard, size I
V23054-C0016-B104 Standard, size I
V23054-C0019-C104 Standard, size I
V23054-C2003-C404 Standard, size I
V23054-C2004-B104 Standard, size I
V23054-C2013-B104 Standard, size I
V23054-C2020-B104 Standard, size I
V23054-C2026-C104 Standard, size I
V23054-C0020-B104 Standard, size I
V23054-C0020-C104 Standard, size I
V23054-C0021-B104 Standard, size I
V23054-C0021-C104 Standard, size I
V23054-C0021-C404 Standard, size I
V23054-C0022-B104 Standard, size I
V23054-C0022-C104 Standard, size I
V23054-C0026-B104 Standard, size I
V23054-C0026-C104 Standard, size I
V23054-C0026-C404 Standard, size I
V23054-C003-B104
Standard, size I
V23054-C003-C104
Standard, size I
V23054-C004-B104
Standard, size I
V23054-C004-C104
Standard, size I
V23054-CXXXX, 5A, size I
V23054-C1022-F105
5A, size I
V23054-C3015-F105
5A, size I
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Coil
Operate/Lim. Arrangement
Contacts
Enclosure
PartNumber
125VDC
12VDC
12.5VDC
20VDC
220VDC
110VDC
125VDC
24VDC
60VDC
24VDC
24VDC
32VDC
32VDC
32VDC
45VDC
45VDC
60VDC
60VDC
60VDC
220VDC
220VDC
110VDC
110VDC
59/190VDC
4.7/18VDC
5.4/21.5VDC
10.5/31VDC
98/240VDC
44/145VDC
59/190VDC
10.5/39VDC
36/94VDC
10.5/39VDC
13/39VDC
14.5/50VDC
17.5/50VDC
17.5/50VDC
19/66VDC
24/66VDC
29/94VDC
36/94VDC
36/94VDC
79/240VDC
98/240VDC
44/145VDC
53.5/145VDC
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
Single
Single
Single
Bifurcated
Bifurcated
Single
Single
Single
Bifurcated
Single
Bifurcated
Single
Bifurcated
Bifurcated
Single
Bifurcated
Single
Bifurcated
Bifurcated
Single
Bifurcated
Single
Bifurcated
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
2-1419172-8
1393812-6
1393812-7
1422019-3
3-1393812-2
3-1393812-3
3-1393812-4
3-1393812-5
3-1393812-6
1-1393812-0
1-1393812-1
1-1393812-2
1-1393812-3
1-1393812-4
1-1393812-5
1-1393812-6
2-1393812-0
2-1393812-3
2-1393812-4
1393812-2
1393812-3
1393812-4
1393812-5
45VDC
12VDC
19/66VDC
4.7/18VDC
2 form A, 2 NO
2 form A, 2 NO
Single
Single
Dust protected
Dust protected
3-1393812-1
1422019-5
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
5
Signal Relays
AXICOM
Cradle S Relay V23054/V23062 (Continued)
Product code
6
Version
V23054-DXXXX, standard, size II
V23054-D0013-B110 Standard, size II
V23054-D0015-B112 Standard, size II
V23054-D0016-C110 Standard, size II
V23054-D0017-B110 Standard, size II
V23054-D0017-B110 Standard, size II
V23054-D0019-B110 Standard, size II
V23054-D0019-C110 Standard, size II
V23054-D0019-C410 Standard, size II
V23054-D2003-B110 Standard, size II
V23054-D2013-B110 Standard, size II
V23054-D2020-B110 Standard, size II
V23054-D2021-B110 Standard, size II
V23054-D2021-B112 Standard, size II
V23054-D2026-B110 Standard, size II
V23054-D2026-B112 Standard, size II
V23054-D0020-B110 Standard, size II
V23054-D0020-B112 Standard, size II
V23054-D0020-C110 Standard, size II
V23054-D0002-C410 Standard, size II
V23054-D0021-B110 Standard, size II
V23054-D0021-C112 Standard, size II
V23054-D0022-B110 Standard, size II
V23054-D0022-C110 Standard, size II
V23054-D0002-B110 Standard, size II
V23054-D0026-B112 Standard, size II
V23054-D0026-C110 Standard, size II
V23054-D0026-C112 Standard, size II
V23054-D0026-C114 Standard, size II
V23054-D003-B110 Standard, size II
V23054-D004-C110 Standard, size II
V23054-DXXXX, 5A, size II
V23054-D1003-F104
5A, size II
V23054-D1004-F104
5A, size II
V23054-D1011-F104
5A, size II
V23054-D1012-F104
5A, size II
V23054-D1015-F104
5A, size II
V23054-D1017-F104
5A, size II
V23054-D1019-F104
5A, size II
V23054-D1020-F104
5A, size II
V23054-D1021-F104
5A, size II
V23054-D1022-F104
5A, size II
V23054-D1026-F104
5A, size II
V23054-D3003-F104
5A, size II
V23054-D0300-F104
5A, size II
V23054-D3020-F104
5A, size II
V23054-D3026-F104
5A, size II
V23054-EXXXX, standard, size III
V23054-E0012-B133 Standard, size III
V23054-E0015-B133 Standard, size III
V23054-E0015-C133 Standard, size III
V23054-E0016-B133 Standard, size III
V23054-E0016-C133 Standard, size III
V23054-E0017-B133 Standard, size III
V23054-E0017-C133 Standard, size III
V23054-E0019-B133 Standard, size III
V23054-E0019-C133 Standard, size III
V23054-E0019-C433 Standard, size III
V23054-E2004-B133 Standard, size III
V23054-E2013-B133 Standard, size III
V23054-E2026-B133 Standard, size III
V23054-E0020-B133 Standard, size III
V23054-E0020-B533 Standard, size III
V23054-E0020-B633 Standard, size III
V23054-E0020-C133 Standard, size III
V23054-E0020-C433 Standard, size III
V23054-E0021-B133 Standard, size III
V23054-E0022-B133 Standard, size III
V23054-E0022-B633 Standard, size III
V23054-E0022-C133 Standard, size III
V23054-E0026-B133 Standard, size III
V23054-E0026-C133 Standard, size III
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Coil
Operate/Lim. Arrangement
Contacts
Enclosure
PartNumber
125VDC
12VDC
12.5VDC
16VDC
16VDC
20VDC
20VDC
20VDC
220VDC
125VDC
24VDC
32VDC
32VDC
60VDC
60VDC
24VDC
24VDC
24VDC
1,2VDC
32VDC
32VDC
45VDC
45VDC
1,2VDC
60VDC
60VDC
60VDC
60VDC
220VDC
110VDC
59/190VDC
4.7/18VDC
5.4/21.5VDC
7/25.5VDC
7/25.5VDC
10.5/31VDC
10.5/31VDC
10.5/31VDC
79/240VDC
59/190VDC
10.5/39VDC
14.5/50VDC
14.5/50VDC
29/94VDC
29/94VDC
10.5/39VDC
10.5/39VDC
13/39VDC
0,75/2,1VDC
14.5/50VDC
17.5/50VDC
19/66VDC
24/66VDC
0,54/2,1VDC
29/94VDC
43/94VDC
36/94VDC
29/94VDC
79/240VDC
44/145VDC
4 form C, 4 CO
6 form A, 6 NO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
6 form A, 6 NO
4 form C, 4 CO
6 form A, 6 NO
4 form C, 4 CO
6 form A, 6 NO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
6 form A, 6 NO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
6 form A, 6 NO
4 form C, 4 CO
6 form A, 6 NO
4 form A, 4 NO
4 form C, 4 CO
4 form C, 4 CO
Single
Single
Bifurcated
Single
Single
Single
Bifurcated
Bifurcated
Single
Single
Single
Single
Single
Single
Single
Single
Single
Bifurcated
Bifurcated
Single
Bifurcated
Single
Bifurcated
Single
Single
Bifurcated
Bifurcated
Bifurcated
Single
Bifurcated
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
4-1419172-5
6-1422019-5
4-1393812-2
4-1393812-3
4-1393812-4
4-1393812-6
4-1393812-7
5-1393812-0
1393813-1
1393813-2
1393813-3
1393813-4
1393813-5
1393813-6
1393813-7
5-1393812-1
5-1393812-2
5-1393812-3
3-1419137-7
5-1393812-4
5-1393812-5
5-1393812-8
5-1393812-9
6-1393812-2
6-1393812-3
6-1393812-4
6-1393812-5
6-1393812-6
3-1393812-8
3-1393812-9
220VDC
110VDC
6VDC
8.4VDC
12VDC
16VDC
20VDC
24VDC
32VDC
45VDC
60VDC
220VDC
110VDC
24VDC
60VDC
98/240VDC
53.5/145VDC
2.9/9VDC
4.4/13VDC
5.8/18VDC
8.7/25.5VDC
10.5/31VDC
13/39VDC
17.5/50VDC
24/66VDC
36/94VDC
98/240VDC
53.5/145VDC
13/39VDC
36/94VDC
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
8-1393812-6
8-1393812-7
8-1393812-8
8-1393812-9
9-1393812-0
9-1393812-1
9-1393812-2
9-1393812-3
9-1393812-4
9-1393812-5
9-1393812-8
1393813-9
1-1393813-1
1-1393813-4
1-1393813-6
8.4VDC
12VDC
12VDC
12.5VDC
12.5VDC
16VDC
16VDC
20VDC
20VDC
20VDC
110VDC
125VDC
60VDC
24VDC
24VDC
24VDC
24VDC
24VDC
32VDC
45VDC
45VDC
45VDC
60VDC
60VDC
4.4/13VDC
5.8/18VDC
8.8/18VDC
6.9/21.5VDC
10/21.5VDC
8.7/25.5VDC
13/25.5VDC
10.5/31VDC
15.5/31VDC
15.5/31VDC
53.5/145VDC
73/190VDC
36/94VDC
13/39VDC
13/39VDC
13/39VDC
20/39VDC
20/39VDC
17.5/50VDC
24/66VDC
24/66VDC
35/66VDC
36/94VDC
55/94VDC
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
6 form C, 6 CO
Single
Single
Bifurcated
Single
Bifurcated
Single
Bifurcated
Single
Bifurcated
Bifurcated
Single
Single
Single
Single
Single
Single
Bifurcated
Bifurcated
Single
Single
Single
Bifurcated
Single
Bifurcated
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
2-1393813-5
2-1393813-6
2-1393813-7
2-1393813-8
3-1393813-0
3-1393813-1
3-1393813-2
3-1393813-3
3-1393813-4
3-1393813-5
9-1393813-0
1422019-2
9-1393813-4
3-1393813-6
3-1393813-9
4-1393813-0
4-1393813-1
4-1393813-2
4-1393813-3
4-1393813-4
4-1393813-5
4-1393813-6
4-1393813-8
4-1393813-9
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Signal Relays
AXICOM
Cradle S Relay V23054/V23062 (Continued)
Product code
Version
V23054-EXXXX, 5A, size III
V23054-E1003-F110
5A, size III
V23054-E1004-F110
5A, size III
V23054-E1011-F110
5A, size III
V23054-E1015-F110
5A, size III
V23054-E1016-F110
5A, size III
V23054-E1017-F110
5A, size III
V23054-E1019-F110
5A, size III
V23054-E1020-F110
5A, size III
V23054-E1021-F110
5A, size III
V23054-E1022-F110
5A, size III
V23054-E1026-F110
5A, size III
5A, size III
V23054-E3020-F110
V23062-AXXXX, standard, size I
V23062-A0014-C404
Standard, size I
V23062-A0025-C104
Standard, size I
Standard, size I
V23062-A0046-C104
V23062-BXXXX, standard, size II
V23062-B0019-C410
Standard, size II
V23062-B0020-C110
Standard, size II
V23062-B0022-C110
Standard, size II
Standard, size II
V23062-B0026-B610
V23062-BXXXX, 5A, size II
V23062-B1004-F104
5A, size II
5A, size II
V23062-B1026-F104
03-2012, Rev. 0312
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Coil
Operate/Lim.
Arrangement
Contacts
Enclosure
PartNumber
220VDC
110VDC
6VDC
12VDC
12.5VDC
16VDC
20VDC
24VDC
32VDC
45VDC
60VDC
24VDC
118/240VDC
66/145VDC
3.5/9VDC
7/18VDC
8.1/21.5VDC
10.5/25.5VDC
13/31VDC
15.5/39VDC
21/50VDC
29/66VDC
43/94VDC
15.5/39VDC
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
Dust protected
5-1393813-9
6-1393813-0
6-1393813-1
6-1393813-3
6-1393813-6
6-1393813-8
7-1393813-2
7-1393813-6
8-1393813-1
8-1393813-2
8-1393813-5
1-1393814-0
76VDC
28VDC
29VDC
32/110VDC
15/40VDC
13/43VDC
2 form C, 2 CO
2 form C, 2 CO
2 form C, 2 CO
Bifurcated
Bifurcated
Bifurcated
Herm. sealed
Herm. sealed
Herm. sealed
1393815-1
1393815-2
1393815-3
20VDC
24VDC
45VDC
60VDC
13/31VDC
15.5/39VDC
29/66VDC
29/94VDC
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
4 form C, 4 CO
Bifurcated
Bifurcated
Bifurcated
Single
Herm. sealed
Herm. sealed
Herm. sealed
Herm. sealed
1393815-4
1393815-5
1393815-7
1393815-8
110VDC
60VDC
53.5/145VDC
36/94VDC
2 form C, 2 CO
2 form C, 2 CO
Single
Single
Herm. sealed
Herm. sealed
1-1393815-1
1-1393815-7
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
7