3-1618100-2

3-1618100-2

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
3-1618100-2 数据手册
Protective Relays Table of Contents PAGE 1 11 Protective Relays KILOVAC WD Series, DIN Rail or Screw Mounted Protective Relays Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-2 KILOVAC WD25 Paralleling Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-3 KILOVAC WD2759 Over/Undervoltage Relays. . . . . . . . . . . . . . . . . . . . . . . . . . 11-4, 11-5 KILOVAC WD32 Reverse Power Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-6, 11-7 KILOVAC WD47 Phase Sequence Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-8 KILOVAC WD5051 1Ø and 3Ø Overcurrent Relays. . . . . . . . . . . . . . . . . . . . . 11-9, 11-10 KILOVAC WD81OU Over/Underfrequency Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . 11-11 Voltage Sensitive Relays WUV/WOV DC Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12 WUV/WOV Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-13 WUVT/WOVT Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-14 WOUV DC Series, Over/Undervoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-15 WOUVT Series, Over/Undervoltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-16 250 Series, Over/Undervoltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-17 D100X Series, Close Differential. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-18 D101X Series, 3 Phase Adjustable, Close Differential . . . . . . . . . . . . . . . . . . . . . . . . 11-19 Reverse Power Relay 700 Series w/ Adjustable Time Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-20 Phase Failure Relay 1000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-21 Phase Sequence Relay 900 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-22 Current Balance Relay WCB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-23 Current Sensitive Relays WC1 & WCT1 Series, Overcurrent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-24 WC3 & WCT3 Series, Overcurrent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-25 Current Differential Relay WCD Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-26 Paralleling Relays 1800 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-27 Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-27 Frequency Sensitive Relays WOF & WUF Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-28 WOUF Series, Over/Underfrequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-29 20-000 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-30 25-000 Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-31 20-050-19 Series (Voltage/Frequency). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-32 Ground Fault Relays WGD Series — Floating Ground. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-33 WC1G Series — Grounded. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-34 Additional Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-35 – 11-43 Protective Relays KILOVAC WD Series, DIN Rail or Screw Mounted Protective Relays Product Facts n WD25 Paralleling (Synch Check) Relays n WD2759 Relays Over/undervoltage Installation and Maintenance Information n WD32 Reverse Power Relays n WD47 Phase Sequence Relays n WD5051 Single- or Three-Phase Overcurrent Relays n WD81OU Over/ Underfrequency Relays n File E58048, DIN EN50022-35 R Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. The WD series offers several different models of protective relays in a common package that is suitable for either DIN rail or screw mounting. These flexible, multifunction devices offer user selectable voltages, sense currents and frequencies. Adjustable time delays are standard. This allows a single part number to be suitable for multiple applications, thereby reducing inventory costs. Installation — To mount the WD series protective relay on a DIN rail, hook the top edge of the cutout on the base of the case over one edge of the DIN rail, then press the opposite side of the cutout containing the release clip over the opposite side of the DIN rail. To remove or reposition the relay, lever the release clip and move the relay as required. WD series relays should be installed in a dry location where the ambient temperature will be within the operating temperature range. Maintenance — WD series protective relays are solid state devices that require no maintenance. They are not designed to be serviced by the user. Consult KILOVAC customer service at 805-2202023 if repairs should be necessary. Outline Dimensions 16 X M3.5 1.38 (35.0) 2.87 (73.0) Specifications Common to All Models Power Consumption — 2.5VA, maximum. Contact Ratings — 5 amps, resistive, at 120VAC. 5 amps, resistive, at 30VDC. Isolation from Control to Sense Inputs — 2,500VAC. Mechanical Life — 10 million operations. Shock — 10g. Vibration — 0.062 (1.57) double amplitude at 10-55 Hz. Terminals — M3.5 screws. Maximum Wire Size — 2 x 24 AWG (2.5mm2) solid to DIN 46288 or 2 x 16 AWG (1.5mm2) stranded w/end sleeves. Operating Temperature Range — -40°C to +60°C. Enclosure — Plastic case (not sealed). Mounting Options — Snap mounts on standard DIN rail (DIN-EN 50022-35) or panel mounts with M4, M5, #8 or #10 screws. Weight — 14.4 oz. (400g) approximately. AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS 4.41 (112.0) 0.35 (9.0) 2.95 (75.0) M5 M4 2.36 (60.0) 1.97 (50.0) 2.36 (60.0) Protective Relays KILOVAC WD25 Paralleling Relays Product Facts n Function Sense Voltage Voltage (nominal) Synch Voltage (% of nom.) Dead Bus Voltage (% of nom.) 25 n ANSI/IEEE C37.90-1978 120 208 277 480 6 - 30% (≈ 4°- 20° electrical degree) 10 - 70% (Dead Bus) Control Voltage WD25 Operation WD25 Specifications WD25 paralleling relays are used to ensure that two circuits are synchronized. When voltage, phase relationship and frequency are within the selected synchronizing limits, the output relay will energize. The WD25 paralleling relay allows for a generator to be brought online without damage or system disturbance. WD25 series with a “dead bus” feature will energize for a synchronized condition or an “on line” generator, “dead bus” condition. This “dead bus” feature allows the generator to energize a dead bus. The “double dead bus” feature permits paralleling of two buses when: (a) both the line voltages are equal and in phase, or (b) when either bus is “hot” and the other bus is “dead.” Nominal Operating Range — 120, 208, 277 or 480 VAC, selectable. Maximum Sensing Range — 575VAC. Nominal Frequency Range — 40-400 Hz. Contact Form — 2 form C (DPDT). Model WD25 Input Voltage (VDC) Input Voltage (VAC) -0X1 18 to 54 — -0X2 13.5 to 32 — -0X3 100 to 200 100 to 140 WD25 Controls WD25 Calibration 11 WD25 Connections Protective Relays The calibration marks on the faceplate are provided only as guides. Proper calibration requires using an accurate voltmeter. Use the following procedure to calibrate the WD25: 1. Remove the cover. 2. Adjust the SYNC VOLTAGE control fully counterclockwise (CCW). Apply nominal voltage to the LINE B (bus) sensing terminals. 3. Apply the maximum desired synchronization voltage to the LINE A (generator) terminals. This voltage should be in phase with LINE B (bus) voltage and have the same frequency. 4. Slowly adjust the SYNC VOLTAGE control clockwise (CW) until the relay energizes. WD25 Typical Hookup Ordering Information Typical Part Number WD 25 -00 2 1. Basic Series: WD = DIN mount Protective Relay. 2. Type: 25 = Paralleling Relay. 3. Dead Bus: 00 = Double Dead Bus 01 = Single Dead Bus 02 = Generator to Generator 4. Control Voltage: 1 = 18 to 54VDC 2 = 13.5 to 32 VDC 3 = 100-200VDC or 100-140VAC. Our authorized distributors are more likely to stock these items. WD25-001 WD25-013 NOTE: For single dead bus option, connect the generator to 1 & 3 and the bus to 5 & 7. PAGE 3 Protective Relays KILOVAC WD2759 Over/Undervoltage Relays Product Facts WD2759 Operation n Function WD2759 AC voltage sensing relays provide voltage monitoring and protection in AC systems from 50 to 400 Hz. Sensing voltages, number of phases, over and undervoltage setpoint, and time delays are user configured. WD2759 voltage relays operate when the externally adjustable trip point is reached. An external time delay control is provided with an adjustment of .5 to 10 seconds. This time delay may be used to prevent false tripping when there are slight variations in the voltage supply. On overvoltage (OV) the output relay energizes when the input signal exceeds the trip point. On undervoltage (UV) the output relay energizes when the input signal goes below the trip point. A green LED indicates power to the relay. Red LED lights indicate the state of the undervoltage and overvoltage trips. 27/59 n ANSI/IEEE C37.90-1978 Sense Voltage Voltage (nominal) UV Adjustment Range OV Adjustment Range 120 208 277 480 72-120 125-208 166-277 288-480 120-168 208-291 277-388 480-672 Control Voltage Model WD2759 Input Voltage (VDC) Input Voltage (VAC) -001 18 to 54 — WD2759 Specifications Nominal Operating Range — 120, 208, 277 or 480 VAC, selectable. Maximum Sensing Range — 700VAC. Nominal Frequency Range — 50-400 Hz. Contact Form — 1 form C (SPDT) for undervoltage and 1 form C (SPDT) for overvoltage. Time Delay Adjustment — 0.5 to 10 sec. WD2759 Calibration The calibration marks on the faceplate have a maximum error of 10% and are provided only as guides. Proper calibration requires using an accurate voltmeter in parallel with the input signal. Use the following procedure to calibrate your relay. OVER VOLTAGE 1. Remove cover. 2. Adjust the TRIP SET control fully clockwise (CW) and the TIME DELAY control fully counterclockwise (CCW). 3. Apply the desired trip voltage to the relay. 4. Slowly adjust the TRIP SET control CCW until the relay trips. Ordering Information Typical Part Number WD 2759 -002 1. Basic Series: WD = DIN mount Protective Relay. 2. Type: 2759 = Over/Undervoltage Relay. 3. Control Voltage: 001 = 18 to 54VDC 002 = 13.5 to 32 VDC 003 = 100-200VDC or 100-140VAC. Our authorized distributors are more likely to stock these items. WD2759-003 AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS -002 13.5 to 32 — -003 100 to 200 100 to 140 5. Remove the applied voltage (do not change the voltage level) and set the TIME DELAY control to the desired time delay. 6. Apply the trip voltage to the relay and measure the time to trip. 7. Adjust the TIME DELAY and repeat steps 4 and 5 until you have the desired time delay. UNDER VOLTAGE 1. Remove cover. 2. Adjust the TRIP SET control fully CCW and the TIME DELAY control fully CCW. 3. Decrease the applied sensing voltage from the nominal value until the desired tripping voltage is reached. 4. Slowly adjust the TRIP SET control CW until the relay trips. 5. Set the TIME DELAY control to the desired time delay and apply nominal voltage to the relay. 6. Step down the applied voltage from nominal to a level jest below the trip level set in Step 3 and measure the time delay. 7. Adjust the TIME DELAY and repeat steps 4 and 5 until the desired time delay is achieved. Protective Relays KILOVAC WD2759 Over/Undervoltage Relays (Continued) WD2759 Controls WD2759 Connections 11 Protective Relays WD2759 Typical Hookup PAGE 5 Protective Relays KILOVAC WD32 Reverse Power Relays Product Facts WD32 Operation n Function WD32 reverse power relays are used to monitor the direction of power from AC generators. This is accomplished by measuring I cos q. If current from the generator is reversed and exceeds the adjustable setting, the relay will trip. A 0.5 to 20 second time delay is provided. A correct setting of the trip point and time delay will prevent motorizing the generator and prevent tripping during transients that occur while synchronizing. A POWER LED indicates the condition of the power supply and a REVERSE POWER TRIP LED indicates the output status of the relay. 32 Control Voltage WD32 Specifications Nominal Operating Range — 120 to 480 VAC, 1 or 3 phase. Maximum Sensing Range — 575VAC. Nominal Sensing Current — 5A. Nominal Frequency Range — WD32-00X — 40-400 Hz.; WD32-01X — 60 Hz. Contact Form — 2 form C (DPDT). Time Delay Adjustment — 0.5 to 20 sec. Sense Current — Reverse Power Trip: 0.2 to 1.0A (4-20% of nominal sense current). Model WD32 Input Voltage (VDC) Input Voltage (VAC) -001 18 to 54 — WD32 Calibration The calibration marks on the faceplate have a maximum error of 10% and are provided only as guides. Proper calibration requires using an accurate Current Meter in series with the input current. Use the following procedure to calibrate your relay. REVERSE POWER 1. Remove cover. 2. Adjust the TRIP SET control fully clockwise (CW) and the TIME DELAY control fully counterclockwise (CCW). 3. Apply the desired trip current to the relay. NOTE: for the Reverse Power (WD32-00X) a resistive load must be used and for the Reverse kVAR (WD32-01X) an inductive load must be used. 4. Slowly adjust the TRIP SET control CCW until the relay trips. 5. Remove the applied Current and set the TIME DELAY control to the desired time delay. 6. Re-apply the Current (10% more than the trip current) to the relay and measure the time to trip. 7. Adjust the TIME DELAY and repeat steps 4 and 5 until you have the desired time delay. Ordering Information Typical Part Number WD 32 -00 2 1. Basic Series: WD = DIN mount Protective Relay. 2. Type: 32 = Reverse Power Relay. 3. Load: 00 = Resistive (power) 01 = Inductive (kVAR, 60 Hz.) 4. Control Voltage: 1 = 18 to 54VDC 2 = 13.5 to 32 VDC 3 = 100-200VDC or 100-140VAC. Our authorized distributors are more likely to stock these items. WD32-003 WD32-011 AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS -002 13.5 to 32 ˜ -003 100 to 200 100 to 140 Protective Relays KILOVAC WD32 Reverse Power Relays (Continued) WD32 Controls WD32 Connections 11 Protective Relays WD32 Typical Hookup PAGE 7 Protective Relays KILOVAC WD47 Phase Sequence Relays Product Facts n Function Control Voltage Model WD47 Input Voltage (VDC) Input Voltage (VAC) 47 n ANSI/IEEE C37.90-1978 WD47 Operation WD47 Specifications WD47 phase sequence relays are designed to monitor the correct phase rotation and loss of phase of three phase ac systems from 50 to 400 Hz. An incorrect phase sequence or loss of any phase will cause the WD47 to pickup. When the phase sequence is corrected or the lost phase is restored the contacts dropout. Red LED’s light to indicate a fault condition. A green LED indicates power to the relay. The WD47 is often used to detect reverse phase rotation or loss of phase to generators, busses, motors, and transformers. Nominal Operating Range — 120 to 480 VAC. Maximum Sensing Range — 575VAC. Nominal Frequency Range — 40-400 Hz. Contact Form — 2 form C (DPDT). WD47 Controls WD47 Calibration The WD47 has no adjustments and no calibration is necessary. Proper operation may be verified as follows: 1. Apply a nominal, three-phase input with the correct phase sequence. The output relay should dropout and the green LED should light. 2. Apply a nominal, three-phase input with an incorrect phase sequence. The output relay should pickup and the red LED should light. 3. Apply only one or two phases with the correct phase sequence. The output relay should pickup and the red LED should light. WD47 Connections WD47 Typical Hookup Ordering Information Typical Part Number WD 47 -002 1. Basic Series: WD = DIN mount Protective Relay. 2. Type: 47= Phase Sequence Relay. 3. Control Voltage: 001 = 18 to 54VDC 002 = 13.5 to 32 VDC 003 = 100-200VDC or 100-140VAC. Our authorized distributors are more likely to stock these items. WD47-001 AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS -001 18 to 54 — -002 13.5 to 32 — -003 100 to 200 100 to 140 Protective Relays KILOVAC WD5051 1Ø and 3Ø Overcurrent Relays Product Facts WD5051 Operation n Function WD5051 AC current sensing relays provide current monitoring and protection in AC systems from 50 to 400 Hz. Nominal Sensing Current, Instantaneous Over Current setpoint, Time Over Current setpoint, and Time Over Current time delay are user configured. WD5051 current relays operate when the externally adjustable trip point is reached. An external time over current time delay control is provided with an adjustment of .5 to 20 seconds. This time delay may be used to prevent false tripping when there are slight variations in the sensed current. With control power applied, the Instantaneous Over Current (IOC) contacts pick-up when the input signal exceeds the IOC trip setpoint. Similarly, with control power applied, the Time Over Current (TOC) contacts pick-up after the preset time delay when the Sense Current rises above the TOC trip setpoint. The IOC contacts may also be configured to function as an under current relay. A green LED indicates power to the relay. Red LED lights indicate the state of the IOC and TOC trips. 5051 Sense Current Current (nominal) 1 3 6 8 IOC 0.2 to 1.2 0.6 to 3.6 1.2 to 7.2 1.6 to 9.6 TOC 0.2 to 1.2 0.6 to 3.6 1.2 to 7.2 1.6 to 9.6 Control Voltage Model WD5051 Input Voltage (VDC) Input Voltage (VAC) -001 18 to 54 — -002 13.5 to 32 — -003 100 to 200 100 to 140 WD5051 Calibration The calibration marks on the faceplate are provided only as guides. Proper calibration requires using an accurate ammeter in series with the current source. Use the following procedure to calibrate your relay: OVERCURRENT 1. Remover the cover. 2. Adjust the TRIP SET control fully clockwise (CW) and the TIME DELAY control (TOC only) fully counterclockwise (CCW). 3. Apply the desired trip current to the relay. 4. Slowly adjust the TRIP SET control CCW until the relay trips. 5. Remove the applied current (do not change the current level). Set the TIME DELAY (TOC only) control to the desired time delay. Ordering Information Typical Part Number WD 5051 -002 1. Basic Series: WD = DIN mount Protective Relay. 2. Type: 5051 = Single Phase Overcurrent Relay. 5051-3 = Three Phase Overcurrent Relay. 3. Control Voltage: 001 = 18 to 54VDC 002 = 13.5 to 32 VDC 003 = 100-200VDC 0r 100-140VAC. Our authorized distributors are more likely to stock these items. WD5051-001 WD5051-003 WD5051-3-001 PAGE 9 11 Protective Relays WD5051 Specifications Sense Current Full Scale — 1, 3, 6 or 8A, selectable. Maximum Sensing Current — 10A continuous; 30A for 10 sec.; 60A for 2.5 sec.; 100A for 0.9 sec.. Nominal Frequency Range — 50-400 Hz. Contact Form — 1 form C (SPDT) for IOC and 1 form C (SPDT) for TOC. TOC Time Delay Adjustment — 0.5 to 20 sec. IOC Operate Time (max.) — 0.2 sec. Protective Relays KILOVAC WD5051 1Ø and 3Ø Overcurrent Relays (Continued) WD5051 Controls WD5051 Connections WD5051 Single Phase Model WD5051-3 Three Phase Model WD5051 Typical Hookup WD5051 Single Phase Model AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS WD5051-3 Three Phase Model Protective Relays KILOVAC WD81OU Over/Underfrequency Relays Product Facts n Function Sense Frequency Frequency (nominal) UF Adjustment Range OF Adjustment Range 81 OU n ANSI/IEEE C37.90-1978 WD81OU Calibration WD81OU frequency relays are used to provide frequency monitoring and protection to generators, buses, power supplies, and other equipment. The relay operates at voltages from 120 to 480 Vac and at nominal frequencies of 50, 60, and 400 Hz. External controls include nominal frequency selection, under frequency (UF) trip set, over frequency (OF) trip set, UF time delay, and OF time delay. A green LED indicates power to the relay. Red LED’s indicate the status of the UF and OF trips. The calibration marks on the faceplate are provided only as guides. Proper calibration requires using an accurate frequency meter in parallel with the input signal. UNDER FREQUENCY 1. Remove the cover. 2. Set the SENSE FREQUENCY to the nominal system frequency. Adjust the Under Frequency TRIP SET fully clockwise (CW) and the TIME DELAY control fully counterclockwise (CCW). 3. Apply the desired trip frequency to the relay. 4. Slowly adjust the TRIP SET control CCW until the relay trips. 5. Set the TIME DELAY control to the desired time delay and apply nominal frequency to the relay. 6. Step down the applied frequency from nominal to just below the trip level set in Step 4 and measure the time delay. 7. Adjust the TIME DELAY and repeat steps 5 and 6 until the desired time delay is set. OVER FREQUENCY 1. Remove the cover. 2. Set the SENSE FREQUENCY to the nominal system frequency. Adjust the OF TRIP SET and TIME DELAY controls fully counterclockwise (CCW). 3. Apply the desired trip frequency to the relay. 4. Slowly adjust the TRIP SET control clockwise (CW) until the relay trips. 5. Set the TIME DELAY control to the desired time delay and apply nominal frequency to the relay. 6. Step down the applied frequency from nominal to just below the trip level set in Step 4 and measure the time delay. 7. Adjust the TIME DELAY and repeat steps 5 and 6 until the desired time delay is set. WD81OU Specifications Nominal Operating Frequency — 50, 60 or 400 Hz., selectable. Maximum Frequency @ 400 Hz. Nominal — 1000 Hz. Nominal Sensing Voltage — 20-480VAC. Maximum Sensing Voltage — 575VAC. Contact Form — 1 form C (SPDT) for underfrequency and 1 form C (SPDT) for overfrequency. Time Delay Adjustment — 0.5 to 10 sec. Ordering Information Typical Part Number 60 48-60 60-72 400 360-400 400-480 Control Voltage Model WD81OU Input Voltage (VDC) Input Voltage (VAC) -001 18 to 54 — -002 13.5 to 32 — -003 100 to 200 100 to 140 WD81OU Controls 11 Protective Relays WD81OU Operation 50 40-50 50-60 WD81OU Connections WD81OU Typical Hookup WD 81OU -002 1. Basic Series: WD = DIN mount Protective Relay. 2. Type: 81OU = Over/Underfrequency Relay. 3. Control Voltage: 001 = 18 to 54VDC 002 = 13.5 to 32 VDC 003 = 100-200VDC or 100-140VAC. Our authorized distributors are more likely to stock these items. None at present. PAGE 11 Protective Relays WUV/WOV DC Series Product Facts n ANSI/IEEE Product Specifications C37.90-1978 Undervoltage Models The relay is energized at normal voltage, N.C. contacts will open and N.O. contacts will close. The relay will de-energize when the voltage drops below the U/V set point. Overvoltage Models The relay is de-energized at normal voltage, N.C. contacts are closed and N.O. contacts are open. The relay will energize, when the voltage rises above the O/V set point. Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. (+) Nominal Voltage — 12 VDC to 560 VDC Drop-out Point (u/v models) — 70-100% of nominal voltage, screwdriver adjustable Pick-Up Point (o/v models) — 100-125% of nominal voltage, screwdriver adjustable Output Contacts — One set N.O., One set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Operating Temperature Range — -40˚C to +75˚C Temperature Effects — Less than 1% voltage drift over the temperature range Power Consumption — 12 to 60 VDC models — 1 W max. 120 to 305 VDC models — 2 W max. 405 to 470 VDC models — 3 W max. 560 VDC model — 4 W max. Time Delay — A short duration delay is provided to prevent nuisance tripping due to momentary dips or surges in voltage. The drop-out delay, following a voltage fault is 75 to 100 milliseconds. (–) Notes: 1. R  emove black screws for access to the O/V and U/V trip adjustment. 2. C  lockwise rotation of the adjustment potentiometer will raise the voltage trip point. 3. The  adjustments are by means of a single turn potentiometer. Use a small screwdriver and do not force beyond the limit stops. Ordering Information Sample Part Number WOV -12DC -A Type: WOV - Overvoltage WUV - Undervoltage Line Voltage VDC 12DC 125DC 18DC 240DC 24DC 250DC 28DC 305DC 32DC 405DC 48DC 430DC 60DC 470DC 120DC 560DC Options: Blank - Standard A = 2 Form A Contacts B = 2 Form B Contacts H = 125 VDC Contacts P = Transient Protection AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Transient Protection — All voltage relays will withstand momentary voltage surges of twice the nominal rated input voltage (standard). Option “P” provides additional transient protection which complies with the requirements of ANSI/IEEE C37.90-1978 Consult factory for additional models. Protective Relays WUV/WOV Series Product Facts n Function 27/59 n ANSI/IEEE n UL Product Specifications TERMINAL STRIPS #6 - 32 SCREWS C37.90-1978 File No. E58048 n CSA File No. LR61158 R R 3.0 3.0 1 /2 3 7 /8 3 2 3/4 1 /2 3 11 / 64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Notes: 1. R  emove black screw for access to the voltage trip adjustment. 2. C  lockwise rotation of the adjustment potentiometer will raise the voltage trip point. Single Phase Three Phase Typical Time Curve Ordering Information Sample Part Number Type: WUV - Undervoltage WOV - Overvoltage No. Phases 1 = Single 3 = Three Line Voltage VAC 120 416 208 440 220 460 230 480 240 525 380 575 Options P - Transient Protection A - Two Normally Open Contacts B - Two Normally Closed Contacts H - 125VDC, 3A Contacts WUV -1 -120 Voltage Above Set Point 40.0 30.0 Overvoltage Relays WOV Series 20.0 10.0 0.0 -10.0 0 0.05 0.1 0.15 0.2 Pick-Up Time Delay 0.25 0.3 Transient Protection — All voltage relays will withstand momentary voltage surges of twice the nominal rated input voltage (standard). Option “P” provides additional transient protection which complies with the requirements of ANSI/IEEE C37.90-1978 Consult factory for additional models. PAGE 13 11 Protective Relays Voltage sensitive relays are available for both AC and DC applications for over/undervoltage protection. Combination over/ undervoltage relays provide bandpass capabilities. AC relays are either single or three-phase type. Three phase models are designed to sense the average of the three phases or the highest single phase. Voltage trip points are screwdriver adjustable, and operation is time-delayed so that momentary voltage transients will not cause nuisance tripping. Nominal Voltage — 120 VAC to 575 VAC Phase — Single or Three Line Frequency — 50-400 Hz Pick-up to Drop-out Differential — 2.5% maximum Drop-out Point (u/v models) — 70-100% of nominal voltage, screwdriver adjustable Pick-Up Point (o/v models) — 100-125% of nominal voltage, screwdriver adjustable Output Contacts — One set N.O., One set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Operating Temperature Range — -20˚C to +65˚C Power Consumption — 2 VA maximum Time Delay — 150-300 ms (UV Model) Minimum Life — 500,000 operations Protective Relays WUVT/WOVT Series Product Facts n Function 27/59 n ANSI/IEEE n UL Product Specifications TERMINAL STRIPS #6 - 32 SCREWS C37.90-1978 File No. E58048 n CSA File No. LR61158 R R 4 1 /8 1 /2 5 /8 4 Overvoltage Models The relay is de-energized at normal voltages, N.C. contacts are closed and N.O. contacts are open. The relay will energize, when the voltage rises and remains above the O/V set point for the duration of the set time delay. 3 Undervoltage Models The relay is energized at normal voltage, N.C. contacts will open and N.O. contacts will close. The relay will de-energize when the voltage drops and remains below the U/V set point for the duration of the set time delay. 3.0 3 1 /2 4 1 /4 11 / 64 " DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Single Phase Three Phase Ordering Information Sample Part Number Type: WUVT - Undervoltage WOVT - Overvoltage WUVT -1 -120 Nominal Voltage — 100 VAC to 575 VAC Phase — Single or Three Line Frequency — 50-400 Hz Pick-up to Drop-out Differential — 1% typical Drop-out Point (u/v models) — 70-100% of nominal voltage, screwdriver adjustable Pick-Up Point (o/v models) — 100-125% of nominal voltage, screwdriver adjustable Output Contacts — One set N.O., One set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Operating Temperature Range — -40˚C to +70˚C Power Consumption — 3 VA maximum Time Delay — 0.5 to 20 seconds, screwdriver adjustable Voltage Reset — The reset is automatic when voltage returns to normal. Notes: 1. R  emove black screws for access to the voltage and time delay adjustment potentiometer. 2. C  lockwise rotation of the voltage adjust potentiometer will raise the voltage trip point. 3. C  lockwise rotation of the time adjust potentiometer will increase the time delay (Pick-up time for O/V models, drop-out time for U/V models). 4. T  he adjustments are single turn potentiometers, use a small screwdriver and do not force beyond the limit stops. 5. O  n U/V models, when the voltage falls to approximately 33% of nominal or below, the relay will drop out in 0.150 to 0 .300 seconds, regardless of the time delay setting. No. Phases 1 = Single 3 = Three (line to line) Line Voltage VAC 100 240 115 380 120 416 150 440 200 460 208 480 220 525 230 575 Options: Blank - Standard A = 2 Form A Contacts B = 2 Form B Contacts H = 125VDC 3A Contacts P = Transient Protection AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Transient Protection — All voltage relays will withstand momentary voltage surges of twice the nominal rated input voltage (standard). Option “P” provides additional transient protection which complies with the requirements of ANSI/IEEE C37.90-1978 Consult factory for additional models. Protective Relays WOUV DC Series, Over/Undervoltage Product Facts n ANSI/IEEE Product Specifications PS TRI S LS INA CREW M S R TE - 32 #6 C37.90-1978 2 13/16 2 .0 3 3 3 7/ 1/ 2 8 The relay will energize at normal voltage conditions. The normally open contacts will close, and the normally closed contacts will open. The relay will de-energize during over or undervoltage conditions. Reset is automatic when the voltage returns to normal. 2 3/ 3 4 1/ 2 11/64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Type: WOUV - Over/Undervoltage Line Voltage VDC 12DC 125DC 18DC 240DC 24DC 250DC 28DC 305DC 32DC 405DC 48DC 430DC 60DC 470DC 120DC 560DC Options: Blank - Standard A = 2 Form A Contacts B = 2 Form B Contacts H = 125 VDC Contacts P = Transient Protection WOUV -12DC -A 160 Percent of Nominal Voltage Sample Part Number Drop-Out Time Delay WOUV...DC Series 180 140 120 100 80 60 40 20 0 0 20 40 60 80 Time Delay (msec) 100 120 140 Transient Protection — All voltage relays will withstand momentary voltage surges of twice the nominal rated input voltage (standard). Option “P” provides additional transient protection which complies with the requirements of ANSI/IEEE C37.90-1978 Consult factory for additional models. PAGE 15 11 Protective Relays Notes: 1. R  emove black screws for access to the O/V and U/V trip adjustment. 2. C  lockwise rotation of the adjustment potentiometer will raise the voltage trip point. 3. T  he adjustments are by means of a single turn potentiometer. Use a small screwdriver and do not force beyond the limit stops. Single Phase Ordering Information Nominal Voltage (±10%) — 12 VDC to 560 VDC Drop-out Point (u/v models) — 70-100% of nominal voltage, screwdriver adjustable Pick-Up Point (o/v models) — 100-125% of nominal voltage, screwdriver adjustable Output Contacts — One set N.O., One set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Operating Temperature Range — -40˚C to +75˚C Temperature Effects — Less than 1% voltage drift over the temperature range. Power Consumption — 12 to 60 VDC models — 1 W max. 120 to 305 VDC models — 2 W max. 405 to 470 VDC models — 3 W max. 560 VDC Model — 4 W max. Time Delay — A short duration delay is provided to prevent nuisance tripping due to momentary dips or surges in voltage. The drop-out delay, following a voltage fault is 75 to 100 milliseconds Protective Relays WOUVT Series, Over/Undervoltage Product Facts n Function Product Specifications 27/59 n ANSI/IEEE C37.90-1978 Voltage sensitive relays are available for both AC and DC applications for overvoltage and undervoltage protection. Combination over/undervoltage relays provide band-pass capabilities. AC relays are either single or three-phase type. Three phase relays are designed to sense the average of the three phases. Voltage trip points are screwdriver adjustable, and operation is time-delayed so that momentary voltage transients will not cause nuisance tripping. Operation The relay will energize at normal voltage condition. The normally closed contact (Form B) will open and the normally open (Form A) will close. The relay will de-energize after time delay when over or undervoltage condition is reached. Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Single Phase Models Three Phase Models Nominal Voltage — 120 VAC to 575 VAC Phase — Single or Three Line Frequency — 50-400 Hz Type of Sensing — Average of all three phases Undervoltage Trip — 70-100% of nominal voltage, screwdriver adjustable Overvoltage Trip — 100-125% of nominal voltage, screwdriver adjustable Drop-out Time Delay — 0.5 to 20 seconds, screwdriver adjustable Pick-up to Drop-out Differential — 2% maximum Output Contacts — One set N.O., One set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Operating Temperature Range — -40˚C to +70˚C Power Consumption — 4 VA maximum Notes: 1. R  emove black screw for access to the voltage trip and time delay adjustment potentiometer. 2. C  lockwise rotation of the voltage adjustment potentiometer will raise the voltage trip point. 3. C  lockwise rotation of the time adjustment potentiometer will increase the drop-out time delay. Ordering Information Sample Part Number WOUVT -1 -120AC Type: WOUVT - Over/Undervoltage No. Phases 1 = Single 3 = Three (line to line) Line Voltage VAC 115 120 200 208 220 230 240 380 Options: Blank - Standard A = 2 Form A Contacts B = 2 Form B Contacts H = 125 VDC Contacts P = Transient Protection AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Option “H” provides for contacts rating of 3 amps @ 125VDC. Option “P” provides additional transient protection which complies with the requirements of ANSI/IEEE C37.90-1978 Consult factory for additional models. Protective Relays 250 Series, Over/Undervoltage Product Facts n Function 27/59 n ANSI/IEEE C37.90-1978 3 3 B .C 7 /8 . A transistorized circuit provides a sharp and accurate response at the preset tripping voltage; unaffected by temperature or frequency variations. 2 00 Models are available for single phase or three phase applications, and are suitable for either 50 Hz, 60 Hz, or 400 Hz operation. The trip point is adjustable. 6 -32 STUDS (6) 3 .5 The 250 series relays provide combined Overvoltage and Undervoltage protection in a single compact unit. Product Specifications 2 .7 . B .C 50 0 0 3 .5 13 / 64 " DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Nominal Voltage — See Ordering Information Undervoltage Trip — 70-100% of nominal voltage, screwdriver adjustable Overvoltage Trip — 100-125% of nominal voltage, screwdriver adjustable Pick-up to Drop-out Differential — 3% maximum Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Contact Form — One set N.O., one set N.C. Operating Temperature Range — -20˚C to +85˚C Notes: 1. R  emove screws for access the overvoltage or undervoltage trip adjustments. Clockwise rotation of the adjustment potentiometer will raise the trip point. Contact Arrangements Single Phase Three Phase Ordering Information Sample Part Number 250X Model: L-L Volts 250X = 120 VAC, 1 Phase, 50-400 Hz 251X = 120/208 VAC, 3 Phase, 4 Wire, 50-400 Hz 252X = 115 VAC, 3 Phase, 3 Wire, 50-400 Hz 253X* = 230 VAC, 3 Phase, 3 Wire, 50-400 Hz 254X* = 380 VAC, 3 Phase, 3 Wire, 50-400 Hz 255X*= 460 VAC, 3 Phase, 3 Wire, 50-400 Hz 256X* = 575 VAC, 3 Phase, 3 Wire, 50-400 Hz Mounting Blank = Stud X = Flange * Enclosure height is 3.835” Consult factory for additional models. PAGE 17 11 Protective Relays NC — Open at nominal voltage. Closed at Overvoltage and Undervoltage NO — Closed at nominal voltage. Open at Overvoltage and Undervoltage Protective Relays D100X Series, Close Differential Product Facts n ANSI/IEEE n UL Product Specifications C37.90-1978 File No. E58048 n CSA File No. LR61158 R R Close Differential Relays are voltage sensitive. The pick-up and drop-out voltage settings are independently adjustable, which allows precise setting of the differential voltage. This relay is available in a wide range of AC and DC voltages. Their primary application is the sensing and control of transfer switches. Operation Monitors a single phase AC signal, and is used for undervoltage detection. Has separate pick-up and drop-out voltage settings, providing an adjustable hysteresis. Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Nominal Voltage — AC, Single Phase, see Ordering Information Nominal Frequency — 50 to 400 Hz. Pick-Up Adjustment Range — 67-100% of nominal voltage Drop-Out Adjustment Range — 67-100% of nominal voltage Maximum Differential Setting — 33% of nominal voltage Minimum Differential Setting — 2% of nominal voltage Output Contacts — Form C (SPDT) Contact Ratings — 5 Amp resistive at 120 VAC or 28 VDC Operating Temperature Range — -20˚C to +85˚C Expected Life — 10 million operations Inverse Time Drop-Out — The differential relay contains a time delay before operation so that momentary voltage transients do not affect the operation of the relay. The time delay has an inverse time characteristic so that excessive voltage conditions will cause a more rapid drop-out. This time delay is approximately 200mSec. (12 cycles) at the trip settings and decreases to 30 mSec. at approximately 15% beyond the trip settings. Notes: 1. R  emove black nylon protective screws to gain access to the two internal adjustment potentiometers. 2. C  lockwise rotation of the pick-up and drop-out adjustment will raise the voltage trip point. 3. T  he relay contacts are shown in the de-energized state. Ordering Information Sample Part Number D100X Model: L-L Volts D100X = 120 VAC D100-6X = 120 VAC, Spike Suppression D100-3X = 208 VAC D100-4X = 240 VAC D100-8X = 277 VAC D100-5X = 480 VAC D100-7X = 510 VAC Surge Withstand Capability is in compliance with the requirements of ANSI/IEEE C37.90B Consult factory for additional models. AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Height 2” 2” 3.125” 3.125” 3.125” 3.125” 3.125” Protective Relays D101X Series, 3 Phase Adjustable, Close Differential Product Facts n ANSI/IEEE n UL Product Specifications #6 - 32 STUDS 10 PLACES C37.90-1978 File No. E58048 n CSA File No. LR61158 R R H2 H1 1 /4 Notes: 1. R  emove screws for access to pick-up and drop-out trip adjustments. 2. C  lockwise rotation of the pick-up and drop-out adjustment will raise the voltage trip point. 1 /2 0 5 5 . 0 4 . 0 5 . 13 / 64 " DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Ordering Information Sample Part Number D101X Model: L-L Volts D101X = 120 VAC D101-6X = 208 VAC D101-4X = 240 VAC D101-10X = 380 VAC D101-7X = 480 VAC Model D101X D101-4X D101-6X D101-7X D101-10X Power Consumption Each Phase 2 VA max. 3 VA max. 3 VA max. 4 VA max. 4 VA max. H1 (inches) 2 3 1/2 3 1/2 3 1/2 3 1/2 H2 (inches) 2 11/16 4 3/16 4 3/16 4 3/16 4 3/16 11 Protective Relays Operation The output contacts will close when the voltage of all three phases is above the pre-set pick-up point, and will open when any one phase drops below its drop-out setting. 4 Close Differential Relays are voltage sensitive. The pick-up and drop-out voltage settings are independently adjustable, which allows precise setting of the differential voltage. This relay is available in a wide range of AC voltages. Their primary application is the sensing and control of transfer switches. Nominal Voltage — AC, Three Phase, see Ordering Information Nominal Frequency — 50 to 500 Hz. Pick-Up Adjustment Range — 66-100% of nominal voltage, screwdriver adjustable Drop-Out Adjustment Range — 66-100% of nominal voltage, screwdriver adjustable Output Contacts — SPNO Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Operating Temperature Range — -20˚C to +85˚C Consult factory for additional models. PAGE 19 Protective Relays 700 Series w/ Adjustable Time Delay Product Facts n Function 32 n ANSI/IEEE n UL Product Specifications TERMINAL STRIPS #6 - 32 SCREWS C37.90-1978 File No. E58048 n CSA File No. LR61158 R R 3 .0 4 .0 1 2 4 / 7 8 4 / Several types of Reverse Power Relays are available including relays sensitive to reverse reactive power (kVAR). KILOVAC is the leading brand of reverse power relays. Our rugged sealed construction provides continuous and reliable operation unaffected by shock, vibration or other severe environments. Reverse Power Relays are used for the protection of generator sets operating in parallel. 7 8 3 / 5 8 4 / 11 / 64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Model 710TD Model 720TD (X) thru 724TD (X) Designed for 120, 220 or 266 volt line to neutral connection For operation on three phase, three wire Ordering Information Sample Part Number Line Voltage — Model 710TD — 120 V, 220 V or 266 V, line to neutral Model 730TD — 120 V, 230 V, 380 V, 460 V, L-L, 3 Phase or 120 V, Single Phase, L-N All models for three phase, three wire sensing are available, see Ordering Information Line Frequency — 50-500 Hz. Current Requirements — 0 to 5 amp max direct or from CT with 5 amp secondary Trip Adjustment — Screwdriver adjustable 4% to 20% (of the 5 amp rating) Time Delay Adjustment — 0.5 to 20 seconds, screwdriver adjustable Output Contacts — One set N.O., one set N.C. Contact Ratings — 5 amp resistive at 120 AC or 28 Vdc Power Consumption — Voltage circuit — 2 VA max. Current circuit — 4 VA max. Weight — 2.75 lbs. max. Notes: 1. R  emove screw for access to the pick-up and time delay adjustments. 2. C  lockwise rotation of the pick-up adjustment will raise the reverse trip point. 3. C  lockwise rotation of the time adjustment will increase the time delay. 4. P  olarity of the voltage and the current connections must be observed for true power sensing. 5. Interchanging connections on terminals 5 and 6, will cause the output contacts to pick-up on forward power and dropout on no power or reverse power. 720TDX Type: 710TD = 120V, 220V, 266V line to neutral 720TD = 120V, L-L, 3 Phase 721TD = 230V, L-L, 3 Phase 722TD = 380V, L-L, 3 Phase 723TD = 460V, L-L, 3 Phase 724TD = 575V, L-L, 3 Phase 725TD = 416V, L-L, 3 Phase 730TD = 120 V, 230 V, 380 V, 460 V, L-L, 3 Phase or 120 V, Single Phase, L-N Mounting: X = Flange Blank - Stud Options: 7 = Reverse Inductive, 60 Hz Consult factory for additional models. AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Protective Relays 1000 Series Product Facts n Function 47 n ANSI/IEEE n UL TERMINAL STRIPS #6 - 32 SCREWS C37.90-1978 File No. E58048 n CSA File No. LR61158 R R Phase failure relays protect motors, equipment and personnel from damage or injury caused by open phase, reversed phase sequence, or low voltage in a three phase system. Models are available for 50 and 60 Hz with voltages up to 575 volts. Motor control switchboards are a common application. 2 Nominal Voltage — See Ordering Information Voltage Drop-Out — 75% to 100% of nominal, screwdriver adjustable Pick-Up to Drop-Out Differential — 3% approx. Ambient Operating Temperature — -40°C to +70°C Temperature Drift — ± 1% Time Delay — See Curve Output Contacts — One set, normally open Contact Ratings — 10 amp at 28 VDC resistive 10 amp at 230 VAC resistive Notes: 1. R  emove screw for access to the undervoltage adjustment. 2. C  lockwise rotation of the adjustment potentiometer will raise the drop-out voltage. 3/4 1/2 3 11/64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. 100 Drop Out Time Delay 90 80 70 60 50 40 30 20 10 0 0 1 2 3 Nominal Voltage Ordering Information Sample Part Number 1004X Type: 1001 = 120 V, 60 Hz, 3 phase,L-L 1007 = 208 V, 60 Hz, 3 phase, L-L 1002 = 230 V, 60 Hz, 3 phase,L-L 1012 = 300 V, 60 Hz, 3 phase, L-L 1013 = 350 V, 60 Hz, 3 phase, L-L 1003 = 380 V, 50 Hz, 3 phase, L-L 1004 = 460 V, 60 Hz, 3 phase,L-L 1005 = 525 V, 60 Hz, 3 phase,L-L 1006 = 575 V, 60 Hz, 3 Phase, L-L Mounting: X = Flange Blank - Stud 11 Protective Relays The relay contacts will remain in their normally open position (de-energized) when voltage with incorrect phase sequence is applied, one or more phases are open, or at undervoltage condition. 3.0 1 /2 3 /8 7 3 Operation The contacts of the relay will close only when it senses normal conditions of three phase power at the proper phase sequence. 3 13/16 Product Specifications Consult factory for additional models. PAGE 21 Protective Relays 900 Series Product Facts n Function Product Specifications Input Voltage — See Ordering Information Output Contacts — SPDT Contact Ratings — 5 amp resistive at 120 Vac or 28 Vdc 47 Phase sequence relays are designed to monitor the correct phase rotation of a three phase system. Several models are available from 50 Hz, 60 Hz, and 400 Hz with voltages up to 575 volts. High shock relay output and reverse contacts are also available. 2 3/4 1 3 /4 6 5 /1 2 Operation The relay remains de-energized when voltage in the proper phase sequence (A, B, C) is applied, the relay is energized when voltage with incorrect sequence (A, C, B) is applied. 3 5/32 2 1/8 6 11/1 2 6 - 32 x 3/8 studs 4 places Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Ordering Information Sample Part Number 901X Type: 900-3X = 120 VAC, 60 Hz, 3 phase,L-L 910X = 190-520 VAC, 60 Hz, 3 Phase, L-L 900-2X = 208-230, 50/60 Hz, 3 Phase 900X = 230 VAC, 60 Hz, 3 phase, L-L 901X = 460 VAC, 60 Hz, 3 phase,L-L Mounting: X = Flange Blank - Stud Consult factory for additional models. AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Protective Relays WCB Series Product Facts n Function 60 or 87 n ANSI/IEEE n UL Product Specifications C37.90-1978 File No. E58048 n CSA File No. LR61158 R R Current Balance Relays are designed to sense unbalanced current flow in a three phase system. The primary application of Current Balance Relays is to protect three phase motors against phase unbalance or phase failure. Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Notes: 1. R  emove black screw for access to the trip adjustment. 2. C  lockwise rotation of the adjustment potentiometer will raise the unbalance trip point. 3. T  he output contacts are shown de-energized. Ordering Information Sample Part Number WCB -120AC -1 -A Type: WCB = Current Balance Control Voltage (± 15%) 26 DC 48 DC 125 AC 120 AC 230 AC 380 AC 460 AC Trip Adjustment Range .5 = 0.1 amp to 0.5 amps 1 = 0.2 amp to 1 amp 2 = 0.4 amp to 2 amp Options: A = two normally open contacts B = two normally closed contacts PAGE 23 11 Protective Relays Operation With control voltage applied to the relay, the output contacts will energize when the three phase currents are balanced (including zero currents), and will be de-energize by unbalance currents. Line Current — Three Phase, AC current, 50-400 Hz Direct or from CT. 5 amp continuously 20 amp, 30 sec. 200 amp, 0.10 sec. Control Voltage — See Ordering Information Unbalanced Trip Point — Screwdriver adjustable. Adjustment range in accordance with ordering information. (The unbalanced value is defined as the difference between the highest and the lowest phase current). Drop-Out Time Delay — 0.9 to 1.3 seconds Surge Withstand Capability — In compliance with C37.90B ANSI/IEEE Operating Temperature — -40°C to +70°C Burden — Current input — 5.0 VA, Phase Control voltage — 3.0 VA Contact Ratings — One set, N.O., One set N.C. 5 amp resistive at 120 VAC or 28 VDC Protective Relays WC1 & WCT1 Series, Overcurrent Product Facts n Function 50/51 n ANSI/IEEE n UL TERMINAL STRIPS #6 - 32 SCREWS C37.90-1978 File No. E58048 n CSA File No. LR61158 R R Current sensitive relays are available for single and three phase applications. Voltage controlled overcurrent relays protect generators against fault currents below the full rated value, when the fault produces a voltage drop as in the case of short circuits or grounds. Phase balance relays are available to sense and control unbalanced current flow in three phase systems. Current differential relays operate when the differential between two currents exceeds preset values. Over/under current phase-band relays are also available. 31 3 7 /2 /8 3.0 23 3 1 /4 /2 See next page for WCT Can Dimensions 11 /64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Time Delay Standard Time Delay (WC1 Series) — A fixed inverse time delay is incorporated in all overcurrent relays and is represented by the typical curves shown. Adjustable Time Delay (WCT1 Series) — The time delay is field adjustable. The standard time delay can be increased by any value between 0.5 and 20 seconds. Ordering Information Line Current — Single Phase, AC current, 50-400 Hz Direct or from CT Control Voltage — See Ordering Information Trip Point — Screwdriver adjustable. Adjustment range in accordance with ordering information. Pick-Up to Drop-Out Differential — Approximately 0.1 amp. Overcurrent Allowance — Maximum of 500% for 0.25 seconds Surge Withstand Capability — In compliance with C37.90B ANSI/IEEE Operating Temperature — -40°C to +70°C Temperature Drift — ± .05% Burden — Current input — 1.2 VA, Control voltage — 2.5 VA Contact Ratings — One set, N.O., One set N.C. 5 amp resistive at 120 VAC or 28 VDC Notes: 1. R  emove black screws for access to the current pick-up and the time delay adjustment. 2. C  lockwise rotation of the pick-up adjustment will raise the current trip point. 3. C  lockwise rotation of the time delay adjustment, (Type WCT1 only) will increase the time delay. Typical Curves (WC1 Series) WCT1 -48DC -5 -B Type: WC1 = Per Time Curves WCT1 = Adjustable Time Delay Control Voltage (± 15%) 26 DC 48 DC 125 AC 120 AC 230 AC 380 AC 460 AC 8 6 Current (amps) Sample Part Number Product Specifications 4 2 0 0 0.1 0.2 Pick-Up Time Delay 0.3 0.4 Trip Adjustment Range 1 = .2 amp - 1 amp 5 = 1 amp to 5 amp 10 = 2 amp to 10 amp Other Options A = Two normally open contacts B = Two normally closed contacts AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS See next page for 3-phase types and consult factory for additional models. Protective Relays WC3 & WCT3 Series, Overcurrent Product Facts n Function 50/51 n ANSI/IEEE n UL Product Specifications TERMINAL STRIPS #6 - 32 SCREWS C37.90-1978 File No. E58048 n CSA File No. LR61158 R R 4.0 3.0 4.0 1 /2 4 7 /8 4 3 21 / 32 See previous page for WC Can Dimensions 11/ 64 " DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Time Delay Standard Time Delay (WC3 Series) — A fixed inverse time delay is incorporated in all overcurrent relays and is represented by the typical curves shown. Adjustable Time Delay (WCT3 Series) — The time delay is field adjustable. The standard time delay can be increased by any value between 0.5 and 20 seconds. Ordering Information Notes: 1. R  emove black screws for access to the current pick-up and the time delay adjustment. 2. C  lockwise rotation of the pick-up adjustment will raise the current trip point. 3. C  lockwise rotation of the time delay adjustment, (Type WCT3 only) will increase the time delay. Typical Curves (WC3 Series) Type: WC3 = Per Time Curves WCT3 = Adjustable Time Delay Control Voltage (± 15%) 26 DC 48 DC 125 DC 120 AC 230 AC 380 AC 460 AC WCT3 -48DC -5 A 8 6 Current (amps) Sample Part Number 7 /8 4 4 2 0 0 0.1 0.2 Pick-Up Time Delay 0.3 0.4 Trip Adjustment Range 1 = .2 amp - 1 amp 5 = 1 amp to 5 amp 10 = 2 amp to 10 amp Other Options A = Two normally open contacts B = Two normally closed contacts See previous page for 1-phase models and consult factory for additional models. PAGE 25 11 Protective Relays Current sensitive relays are available for single and three phase applications. Voltage controlled overcurrent relays protect generators against fault currents below the full rated value, when the fault produces a voltage drop as in the case of short circuits or grounds. Phase balance relays are available to sense and control unbalanced current flow in three phase systems. Current differential relays operate when the differential between two currents exceeds preset values. Over/under current phase-band relays are also available. Line Current — Three Phase, AC current, 50-400 Hz Direct or from CT Control Voltage — See Ordering Information Trip Point — Screwdriver adjustable. Adjustment range in accordance with ordering information. Pick-Up to Drop-Out Differential — Approximately 0.1 amp Overcurrent Allowance — Maximum of 500% for 0.25 seconds Surge Withstand Capability — In compliance with the requirements of ANSI/IEEE Operating Temperature — -40°C to +70°C Temperature Drift — ± 0.05%/°C Burden — Current input — 1.2 VA, Control voltage — 2.5 VA Contact Ratings — One set, N.O., One set N.C. 5 amp resistive at 120 VAC or 28VDC Protective Relays WCD Series Product Facts n Function TERMINAL STRIPS #6 - 32 SCREWS 87 n ANSI/IEEE C37.90-1978 3 4 4 4 1 /2 7 /8 Current Differential Relays are used for the protection of transformers, motors and generators, by comparing the magnitude of the current entering and leaving the protected circuit. On a given phase winding, any difference between the two currents will indicate an internal fault; the relay will sense the vectorial difference between the two currents of the protected section and will initiate a quick disconnection of the unit, to prevent disastrous consequences. 3 7 /8 4 5 /8 Line Current — Single Phase, AC current, 50-400 Hz Direct or from CT 5 amp continuously 20 amp 30 seconds 200 amp, 0.10 seconds Control Voltage — See Ordering Information Differential Trip Point — Screwdriver adjustable. See Ordering Information Operating Temperature — -40°C to +75°C Burden — Current input — 2.5 VA max. Control voltage D  C — 2 W max. AC — 2 VA max. Output Contacts — One set, N.O., One set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC .172 DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. The relay may also be used to protect internal faults on transformers, such as: ground faults, shorted winding, leakage between primary and secondary, etc. It will sense and compare primary vs. secondary currents, once the turns ratio has been taken into consideration. Operation With control voltage applied, the output contacts (shown in the de-energized position) will remain de-energized as long as the difference between the two input currents remains below the preset trip value. The contact will transfer to the energized position when the current difference exceeds the trip value. Product Specifications Notes: 1. R  emove black screws for access to the trip adjustments. 2. C  lockwise rotation of the adjustment potentiometer will raise the current differential trip point. 3. T  he output contacts are shown de-energized. Ordering Information Sample Part Number WCD -230AC -1 -A Type: WCD - Close Differential Control Voltage 120AC 25DC 208AC 48DC 230AC 125DC 380AC 416AC 460AC 525AC 575AC Trip Adjustment Range .5 = 0.1 amp to 0.5 amp 1 = 0.2 amp to 1 amp 2 = 0.4 amp to 2 amp Options: A = Two normally open contacts B = Two normally closed contacts H = Contacts rated 3 amp at 125 VDC P = Transient protection is provided in compliance with ANSI/IEEE C37.90-1978 AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Consult factory for additional models. Protective Relays 1800 Series Product Facts n Function 25 n ANSI/IEEE n UL Product Specifications #6 - 32 STUDS 6 PLACES C37.90-1978 File No. E58048 n CSA File No. LR61158 R R Output Contact Options — 1. Two Form A. (Add -A to Model Number) 2. Two Form B. (Add -B to Model Number) Consult factory for additional models. 7 /8 3 5 /8 4 11 11 /64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. A. 3 Phase, 4 Wire System Connect phase “A” of LINE 1 to terminal 1 Connect phase “A” of LINE 2 to terminal 3 Connect the neutrals to terminals 2 & 4 B. 3 Phase, 3 Wire or 1 Phase, 2 Wire System Connect phase “A” of LINE 1 to terminal 1 Connect phase “B” of LINE 1 to terminal 2 Connect phase “A” of LINE 2 to terminal 3 Connect phase “B” of LINE 2 to terminal 4 Selection Guide (Typical Applications) Sensing Voltage 120 Volts 230 Volts 380 Volts 460 Volts 575 Volts 415 Volts 277 Volts Series 1800* Generator to Generator 1810X 1820X 1830X 1840X 1850X 1860X 1870X Series 1800DB** Generator to Bus 1810DBX 1820DBX 1830DBX 1840DBX 1850DBX 1860DBX 1870DBX Series 1800DDB*** Bus to Bus 1810DDBX 1820DDBX 1830DDBX 1840DDBX 1850DDBX 1860DDBX 1870DDBX Series 1800 Series 1800DB Series 1800DDB Condition Contacts Contacts Contacts Energized Not Synch. N.C. N.O. N.C. N.O. N.C. N.O. Energized Line 1 X 1 Open Close Open Close Open Close Line 2 X Yes Line 1 X No 2 Close Open Close Open Close Open Line 2 X No Line 1 X 3 Close Open Open Close Open Close Line 2 X Line 1 X 4 Close Open Close Open Close Open Line 2 X Line 1 X 5 Close Open Close Open Open Close Line 2 X PAGE 27 Protective Relays Notes *Permits paralleling of two generators only when they are “on-line” and their voltages are equal and in phase (synchronized) **Normally used to permit paralleling of a generator to a bus when: (a) both line voltages are equal and in phase, or: (b) when the generator is “on-line” and the bus is “dead” ***Permits paralleling of two power lines (buses) when: (a) both line voltages are equal and in phase, or: (b) when either bus is “hot” and the other bus is “dead” 3 4 1 /2 4 7 /8 4 Application These relays are designed for automatic paralleling (synchronizing) of generators. The relays sense the phase angle displacement and the amplitude difference between two voltages and permit paralleling only when both voltages are equal and in phase. A short time delay is provided to assure that the frequencies are essentially the same at the moment of paralleling. The basic series is designed to parallel two or more energized AC generators. The “Dead Bus” type provides paralleling of AC generators to the main bus. They permit electrical connection of an energized generator to an un-energized line (Dead Bus). If the bus is energized, connection of the generator to the bus is permitted only when both are synchronized. Sensing Voltage — 120 V, 230 V, 277 V, 380 V, 460 V, 575 V, & 415 V Line Frequency — 50-500 Hz Pick-Up Adjustment — External adjustment for field sensing of 10-30% of nominal input voltage. (Vertical voltage differential of 6 to 18 electrical degrees). Time Delay — Fixed @ 60 milliseconds is provided to assure that the frequencies of both input lines are sufficiently close to permit paralleling within the preset window. Output Contacts — One set N.O., one set N.C. 5 amp resistive at 120 VAC or 28 VDC Protective Relays WOF & WUF Series Product Facts n Function 81 O/U n ANSI/IEEE n UL Product Specifications C37.90-1978 File No. E58048 n CSA File No. LR61158 R R 2 1/2 5 /8 3 1 /8 4 2 1/ 4 3 / 1 4 4 / 1 2 11/ 64 " DIA. 4 HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Typical Curves (WOF Series) Typical Curves (WUF Series) 90 60 Overfrequency Relay Model WOF-12-6070 85 58 Hz. Setting 55 80 Frequency (Hz) Frequency (Hz) Application The output contacts of frequency relays are energized when the frequency exceeds the adjustable set point. Overfrequency and underfrequency relays are available in 50, 60 and 400Hz. Combination over/ underfrequency “band pass” relays are also available. These are energized at rated frequency and de-energized during overfrequency or underfrequency conditions. Frequency Differential relays are energized above the preset frequency. The pick-up and drop-out frequency settings are independently adjustable. Nominal Voltage (±20%) — 120, 230, 380 and 460 volts Nominal Frequencies — 50, 60 and 400 Hz. Trip Point — Screwdriver adjustable. Adjustment range in accordance with ordering information. Operating Temperature — -20°C to +65°C Differential — The frequency pitch-up to drop-out differential is .5% max Voltage Drift — ± .05% maximum frequency error for input voltage variation of ±10% Time Delay — See Time versus Frequency curves Surge Withstand Capability — In compliance with C37.90B ANSI/IEEE Output Contacts — One set N.O., one set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28VDC 75 70 Hz. Setting 70 65 Hz. Setting 65 3 2 4 5 40 30 60 1 50 Hz. Setting 45 Underfrequency Relay Model WUF-12-5060 35 62 Hz. Setting 0 55 Hz. Setting 50 0 1 6 2 3 4 5 6 Drop-Out Time Delay (sec) Pick-Up Time Delay (sec) Ordering Information Sample Part Number Time Delay WUF -12 -5060 -T Type: WUF = Underfrequency WOF = Overfrequency Input Voltage (VAC) 12 = 120 23 = 230 38 = 380 46 = 460 Frequency Range 4050 = 40-50 HZ 5060 = 50-60 HZ 6070 = 60-70 HZ 3540 = 350-400 HZ 4045 = 400-450 HZ (overfrequency only) Consult factory for additional models. Time Delay Options blank = Per Time Curve T = Adjustable AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Standard Time Delay — A minimum, fixed inverse time delay is incorporated in all frequency relays to prevent nuisance tripping and is represented by the typical curves shown above. Adjustable Time Delay — If additional time delay is required, a suffix “T” must be added to the part number. This allows the minimum fixed time delay to be field-adjustable up to 20 seconds. Notes: 1. R  emove black screws for access to the frequency and the time adjustments. 2. C  lockwise rotation of the frequency potentiometer will raise the frequency trip point. 3. C  lockwise rotation of the time adjustment, option “T” will increase the time for overfrequency relays and dropout time for underfrequency relays. Protective Relays WOUF Series, Over/Underfrequency Product Facts 81 O/U n ANSI/IEEE n UL C37.90-1978 S TRIP S AL S MIN SCREW R E T 32 #6 - File No. E58048 n CSA File No. LR61158 R R 3 3 4 1 /2 1 /8 5 /8 4 3 1 /2 1 /4 4 11 / 64 " DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Operation The relay will energize at normal frequency; The normally closed contacts will open and the normally open contacts will close. The relay will drop-out after time delay at overfrequency or underfrequency. Time Delay Ordering Information Sample Part Number WOUF -12 -5060 -T Type: WOUF = Over/Underfrequency Input Voltage (VAC) 12 = 120 23 = 230 38 = 380 46 = 460 Frequency Range UF Adj. 50 = 40-50 Hz 60 = 50-60 Hz 400 = 350-400 Hz Time Delay Options blank = Per Time Curve T = Adjustable Consult factory for additional models. 11 Notes: 1. R  emove black screws for access to the frequency and the time adjustments. 2. C  lockwise rotation of the frequency potentiometer will raise the frequency trip point. 3. C  lockwise rotation of the time adjustment, option “T” will increase the drop-out time delay. Protective Relays The output contacts of frequency relays are energized when the frequency exceeds the adjustable set point. Overfrequency and underfrequency relays are available in 50, 60 and 400Hz. Combination over/ underfrequency “band pass” relays are also available. These are energized at rated frequency and de-energized during overfrequency or underfrequency conditions. Frequency Differential relays are energized above the preset frequency. The pick-up and drop-out frequency settings are independently adjustable. Nominal Voltage (±20%) — 120, 230, 380 and 460 volts Nominal Frequencies — 50, 60 and 400 Hz. Trip Point — Screwdriver adjustable. Adjustment range in accordance with ordering information. Operating Temperature — -40°C to +65°C Differential — The frequency pick-up to drop-out differential is .5% max Voltage Drift — ± 0.05% maximum frequency error for input voltage variation of ±10% Time Delay — See Time versus Frequency curves Surge Withstand Capability — In compliance with C37-90B ANSI/IEEE Output Contacts — One set N.O., one set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Standard Time Delay — A minimum, fixed inverse time delay is incorporated in all frequency relays to prevent nuisance tripping and is represented by the typical curves shown below. Adjustable Time Delay — If additional time delay is required, a suffix “T” must be added to the part number. This allows the minimum fixed time delay to be field-adjustable up to 20 seconds. Typical Curves (WOUF Series) 90 80 70 OF Adj. 50-60 Hz 60-70 Hz 400-450 Hz Frequency n Function Product Specifications 60 50 40 30 0 1 2 3 4 Drop-Out Time Delay 5 6 PAGE 29 Protective Relays 20-000 Series Product Facts n Function Product Specifications #6 - 32 STUDS 6 PLACES 81 O R Operation The normally open contacts close, and the normally closed contacts open, at all frequencies above the set point. The contacts in the connection diagram, are shown in the de-energized position (below the trip set point). 4 1/2 3 13/16 3.0 1 /2 3 7 /8 3 The output contacts of frequency relays are energized when the frequency exceeds the adjustable set point. Overfrequency and underfrequency relays are available in 50, 60 and 400Hz. Combination over/ underfrequency “band pass” relays are also available. These are energized at rated frequency and de-energized during overfrequency or underfrequency conditions. Frequency Differential relays are energized between the preset frequencies. The pick-up and drop-out frequency settings are independently adjustable. 2 3/4 1/2 3 Input Voltage (±10%) — 120 VAC, Single Phase Frequencies Range (adjustable) — See Ordering Information Differential — Frequency pick-up to drop-out differential is 1% max Temperature Range — -40°C to +85°C Temperature Drift — ± 1% frequency error over temperature range Voltage Error — ± 1% for input voltage of 120 VAC ± 10% Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Output Contacts — One set N.O., one set N.C. Notes: 1. R  emove screw for access to trip adjustment. 11/64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. 120VAC Ordering Information Sample Part Number 20 -050 X Type: 20 - Frequency Frequency Range 040 = 40-50 Hz 050 = 50-60 Hz 060 = 60-70 Hz 350 = 350-500 Hz 400 = 400-450 Hz Mounting Options X = Flange blank = Stud Consult factory for additional models. AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Protective Relays 25-000 Series Product Facts n Function Product Specifications 81 O/U n ANSI/IEEE #6 - 32 STUDS 6 PLACES C37.90-1978 3 13/16 3.0 37 Notes: 1. T  he contacts are shown in the de-energized position. 2. R  emove screws for access to the underfrequency and overfrequency trip adjustments. 3. C  lockwise rotation of the adjustment potentiometer will raise the frequency trip points. 1 /2 /8 2 3 /4 1 /2 3 11 / 64 " DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Ordering Information Sample Part Number 25 -050 X Type: 25 - Over/Underfrequency Frequency Range Under 050 = 40-50 Hz 060 = 50- 60 Hz 400 = 350- 400 Hz Mounting Options X = Flange blank = Stud 11 Protective Relays Operation The normally open contacts close, and the normally closed contacts open, at nominal frequency. The contacts are de-energize at underfrequency, overfrequency or no input voltage. 4 1/ 2 3 The output contacts of frequency relays are energized when the frequency exceeds the adjustable set point. Overfrequency and underfrequency relays are available in 50, 60 and 400Hz. Combination over/ underfrequency “band pass” relays are also available. These are energized at rated frequency and de-energized during overfrequency or underfrequency conditions. Frequency Differential relays are energized above the preset frequency. The pick-up and drop-out frequency settings are independently adjustable. Input Voltage (±10%) — 120 VAC Frequency Range (adjustable) — See Ordering Information Trip Points — Screwdriver adjustable Temperature Range — -20°C to +85°C Temperature Drift — ± 1% frequency error over temperature range Voltage Drift — ± 1% frequency error input voltage variation of ± 10% Contact Ratings — 5 Amp resistive at 120 VAC or 28VDC Output Contacts — One set N.O., One set N.C. Over 50-60 Hz 60-70Hz 400-450Hz Consult factory for additional models. PAGE 31 Protective Relays 20-050-19 Series (Voltage/Frequency) Product Facts n Function 27/81 n ANSI/IEEE n UL Product Specifications #6 - 32 STUDS 6 PLACES C37.90-1978 file No. E58048 n CSA file No. LR61158 R R 4 1/2 3 13/16 Notes: 1. R  emove black screws for access to the voltage and frequency and the time adjustments. 2. C  lockwise rotation of the voltage adjustment potentiometer will raise the voltage trip point. 3. C  lockwise rotation of the frequency adjustment will raise the frequency time point. 3.0 2 1/ 3 The output contacts of frequency relays are energized when the frequency exceeds the adjustable set point. Overfrequency and underfrequency relays are available in 50, 60, and 400Hz. Combination over/ underfrequency “band pass” relays are also available. These are energized at rated frequency and de-energized during overfrequency or underfrequency conditions. Frequency Differential relays are energized above the preset frequency. The pick-up and drop-out frequency settings are independently adjustable. 2 Nominal Voltage (±20%) — 120 VAC, Single Phase Nominal Frequency — 60 Hz. Voltage Adjustment Range (PU) — 85 to 120 VAC Frequency Adjustment Range (PU) — 45 to 60 Hz Output Contacts — One set N.O., one set N.C. Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC 3 /4 1 /2 3 11 /64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Ordering Information Sample Part Number 20-050-19X Type: 20-050-19 = Voltage/Frequency Mounting Options Blank = stud X = Flange Options: P = Surge Suppression Consult factory for additional models. AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS Protective Relays WGD Series — Floating Ground Product Facts n ANSI/IEEE n UL TERMINAL STRIPS #6 - 32 SCREWS C37.90-1978 file No. E58048 n CSA file No. LR61158 R R 3.0 3 5 /8 1 /2 1 /8 4 3 / 1 4 4 / 1 2 11 / 64 " DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. Sensing Voltage (±10%) — 3 phase, 3-wire. See Ordering Information. Control Voltage — 120 Volts AC Contacts Trip Points (sensitivity) — Screwdriver adjustable. See Ordering Information. Pick-up Time Delay — 1.5 seconds approximately Contact Ratings — 5 amp resistive at 120 VAC or 28 VDC Operating Temperature — -40°C to +65°C Temperature Effects — ± 1% over temperature range Power Consumption — Sensing: —2 mA/Phase Approx., Control — 2VA at 120VAC Surge Withstand Capability — In accordance with the requirements of ANSI/IEEE Notes: 1. R  emove screw for access to the pick-up adjustment potentiometer. 2. C  lockwise rotation of the adjustment potentiometer will raise the relay sensitivity. Ordering Information Sample Part Number Type: Volts L-L 115-120AC 120-120AC 200-120AC 208-120AC 220-120AC 230-120AC 240-120AC 380-120AC 400-120AC 416-120AC 440-120AC 460-120AC 480-120AC 525-120AC 575-120AC 600-120AC 115 120 200 208 220 230 240 380 400 416 440 460 480 525 575 600 WGDTrip Point Adj. Phase to Ground 11-55KΩ 12-60KΩ 20-100KΩ 21-105KΩ 22-110KΩ 23-115KΩ 23-115KΩ 38-190KΩ 40-200KΩ 42-210KΩ 44-220KΩ 46-230KΩ 48-240KΩ 52-260KΩ 57-285KΩ 60-300KΩ PAGE 33 11 Protective Relays Operation When the resistance between any phase to ground falls below the set point the relay will energize; The normally closed contacts will open, the normally open contacts will close. 4 Ground Fault Detectors are used to sense leakage current to ground in power transformers and generators. They are available for both AC and DC systems. Some generator systems provide auxiliary power outlets for small equipment. TE Connectivity GFD’s eliminate personnel risk of accessing these outlets if a ground fault exists. Diesel locomotives and railroad line signal boxes also use GFD’s for operational control purposes. The GFD monitors both positive and negative grounds for fault currents and can trigger either notification or system shutdown if these are detected. GFD’s are available for both grounded and ungrounded systems. Product Specifications Protective Relays WC1G Series — Grounded TERMINAL STRIPS #6 - 32 SCREWS 3.8 3.0 1 /2 /38 35 5 2 4.1 /2 41 Ground Fault Detectors are designed to provide very sensitive Ground-Current protection for motor, equipment and personnel from damage or electrical shock. In a ground system, the leakage current is monitored through a toroidal or doughnut current transformer placed around the supply conductors to a motor, transformer, equipment or outlets. Since the sums of the current in a system add to zero, the relay is responsive only to ground-fault current. 1. Control voltage is applied. 11/ 64" DIA. 4 MTG. HOLES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm. 2. Leakage current exceed the trip setting. Current Transformer Ordering Information Sample Part Number Model: WC1GControl Voltage 120AC 220AC 230AC 380AC 400AC 460AC 480AC 575AC AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS CT Window Diameter — 1.7 inches (std) or can be specified by customer Leakage Current Range — 10 to 60 mA Control Voltage — See Ordering Information Output Contacts — One set N.C., one set N.O. Operating Temperature — 40°C to +65°C Contact Ratings — 10 amp resistive at 250 Vac, 8 amp. resistive @ 30 Vdc Notes: 1. R  emove screw for access to the pick-up adjustment potentiometer. 2. C  lockwise rotation of the adjustment potentiometer will raise the relay sensitivity. 1 2 3 / 1 4 4 / Operation The output contacts are shown in de-energized position. They will change state when these conditions are met: Product Specifications WC1G-120AC Protective Relays Additional Relays OVERVOLTAGE RELAYS 30/60VAC, 400V Max. Contin., 120V 60Hz Ctrl. 300-52X 208VAC, 208-291V, 24VDC Ctrl., 1 N.O. Contact 300-53X 200-480VAC, 200-240V Range 300DC-1X 28VDC, Set at 30V, Curve 1 MIL-STD-704 AC, SINGLE PHASE, 400 HZ 302X 120VAC 302-SX 120VAC, A.E.I. . Special 302-1X 120VAC, 0.3 Sec. T.D. 302-2X 120VAC, 125-175V Range 302-3X 120VAC, 125-150V Range with T.D. 302-4X 120VAC, 125-150V Range, 0.3 Sec. T.D. AC, THREE PHASE, 50-400 HZ, SPECIALS 301X 120/208VAC4W 301-SX 120/208VAC, 4W, Similar to WOV-3-208 with hi-shock 301-HX 120/208VAC, 4W, 125VDC 3A Contacts 301-1X 240VAC, 4W, 240-330V Range 301-2X 220/380VAC, 4W 301-3X 254/440VAC, 4W, 440-605V Range 301-3HX 277/480VAC, 4W, 125VDC 3A Contacts 301-4X 127/220VAC, 4W, 220-275V Range 301-4HX 120/208VAC, 4W, 125VDC 3A Contacts 301-5X 380VAC, 4W, 370-460V Range 301-6X 380VAC, 4W, 375-528V Range 301-7X 120/208VAC, 4W, 0.022 Sec. T.D. 301-8X 120VAC. 3W, 120-150VAC 301-9X 240VAC, 3W, 240-300V Range 301-11X 120/208VAC, Similar to 301-7X 301-12X 440VAC, 3W 301-13SX 120/208VAC, 4W, Hi-Shock, T.D., Solar 301-15X 120/208VAC, 4W, 140-180V Range 301-16X 254/440VAC, 4W, Sim to 301-3, but 3 XFMS 301-17SX 120VAC, 3W, Sim to 301-13SX except 120V 301-18X 277/480VAC,4W,3 independent adjustments 301-19SX 94VAC, 3W, Similar to 301-17SX 301-20SX 86/150VAC, 4W, 90-120V Range, T.D., Solar 301-21X 460VAC, 3W, 125VDC Contacts 301-22X 277/480VAC, 4W, 323-425V Range (L-N) 301-23X 380VAC, 3 or 4W, 0.022 Sec. T.D. 301-25X 120/208V, 4W, 2-3 Sec. T.D. 301-26X 416VAC, 3 or 4W, 415-520V Range 301-27X 277/480VAC, 4W, 2-3 Sec. T.D. 301-28X 20.8VAC, 3W, 20-25V Range 301-29X 480VAC, 3 or 4W, Sim. to 301-3X with spike supp. 301-30SX 100VAC, 3W, 100-125V Range, hi-shock 301-31X 208-240, 3W, 200-280V Range, 45-65 Hz. 301-32X 400VAC, 3W, 400-500V Range 301-34X 208VAC, 3W, Set 240V, Withstand 600V contin. 301-35X 120VAC, 3W, 3-5 Sec. T.D. 301-37X 120VAC, 3W, Sim. to 301-8X with spike suppression 301-39X 138/240VAC, 3 or 4W, 2 Sec. T.D. 301-40X 120/208VAC, 4W, Highest of 3, Solar 301-41SX 450VAC, 3W, Navy Hi-Shock, 75VDC 3A Contacts 301-42X 120VAC, 3W, Highest of 3, 120-150V Range 301-45X 120/208VAC, 4W, Highest of 3, Adj. T.D. 301-46X 104VAC, 3W, Similar to WOV-3-104 PAGE 35 11 Protective Relays AC, SINGLE PHASE, 50-400 HZ, SPECIALS 300X 120VAC 300HX 120VAC, Similar to 300X,with 125VDC 3A Contacts 300S-1X 440VAC, 370-480V Range, Navy High Shock 300-2X 120VAC, Set at 132V, .010 Sec.Time Delay 300S-2X 120VAC, Navy High Shock 300-3X 190VAC, 180-280V Range 300-4X 190VAC, P.U. 264V, D.O. 261V 300-5X 240VAC, 230-360V Range 300-5KX 240VAC, Similar to 300-5X, except 1-10KHz 300-6X 230VAC, 230-300V Range 300-7X 450VAC, 375-475V Range 300-8X 120VAC, P.U. 130V, D.O. 125V 300-9X 120VAC, P.U. 132V, D.O. 126V 300-10X 120VAC, 99-132V Range 300-10HX 120VAC, Sim. to 300-10X, 125VDC 3A Contacts 300-11X 120VAC, 0.5 Sec. Time Delay 300-12X 480VAC,480-600V Range 300-13X 120VAC, 2 N.O. Contacts 300-14X 95VAC, 95-120V Range 300-17X 120VAC, Similar to 300X with Spike Suppression 300-18X 120VAC, Differential, 2V Max. 300-20X 10VAC, 8-12V Range, 120V Transient, 120VAC Ctrl. 300-21X 120VAC, 1.5-2.0 Sec. Time Delay 300-24X 277VAC, 140-320VAC Range 300-25X 24VAC, 24-30VAC Range 300-26X 120VAC, 90-150V Range 300-27X 120VAC, 105-135VAC Range 300-28X 10VAC, 8-12VAC , 220VAC Transient, 120VAC Ctrl. 300-29X 120VAC, 150-180V Range 300-30X 120VAC, 375V Max., 24VDC Control 300-32X 120VAC, 135-180V Range, 1.5 Sec. Time Delay 300-33X 115/230VAC, DPDT Contacts 230VAC 1A 300-34X 100VAC, 1.5-2.0 Sec. T.D., 100-120V Range 300-35X 480VAC, 1.5-2.0 Sec. T.D., 480-600V Range 300-36X 138VAC, 138-172V Range 300-37X 350VAC, 350-450V Range, 2.0 Sec. T.D., Supp. 300-38X 120VAC, 99-132V Range, 125VDC 1A Contacts 300-39X 120VAC, 120-150V Range, 0.3-3.0 Adj. T.D. 300-40X 230VAC, 220-300V Range, 2.0 Sec. T.D. 300-41X 120VAC, 120-165V Range, 1.5 Sec. T.D., Supp. 300-42X 120VAC, Similar to 300-39X, but 2 N.O. Contacts 300-43X 120/240VAC, 140-180V Range, Phase Protection 300-44X 277VAC, 277-350V Range 300-45X 30/60VAC, 277V Continuous, 115VAC Control 300-46X 67VAC, 67-120V Range 300-47X 360VAC, 10-64V Range, 0.75-7.5 Sec. T.D. 300-48X 10VAC, 8-21V, 220VAC Transient, 125VDC Ctrl. 300-49X 120VAC, Similar to WOV-1-120, but 0.2 Sec. T.D. 300-50X 120/240VAC, Highest of 2, 0.5-10 Sec. T.D. 300-51X Protective Relays Additional Relays (Continued) 301-47X 69/120VAC, 4W, 69-90V Range, 120V (L-N) Contin. 301-48X 380VAC, 3 or 4W, 380-500V Range 301-49X 250VAC, Withstand 520VAC Continuous 301-50X 180VAC, 3W, Similar to WOV-3-180 301-51X 120VAC, 3W, Supp, 10CFR Class1E (Nuclear) 301-52X 95VAC, 3W, 95-120V (L-L) Range 301-53X 115/200VAC, Similar to WOV-3-200, 1.0 Sec T.D. AC, THREE PHASE, 400 HZ 303X 120/208VAC, 4W 303-1X 115/200VAC, 4W, Highest of 3, T.D., MIL-E-7894 303-1SX 115/200VAC, 3W, High Shock 303-2X 120/208VAC, 4W, High of 3, T.D., MIL-E-7894 303-3X 120/208VAC, Highest of 3, T.D. 303-4X 120VAC, 3W, 120-160V Range 303-8X 254/440VAC, 4W 303-9X 240/416VAC, 4W 303-10X 120/208VAC, 4W, 168V P.U., Kato 303-12X 120/208VAC, 4W, Fast Operating 303-13X 120/208VAC, 4W, 0 deg. C to 90 deg. C 303-15X 120/208VAC, Sim. to 303-13X with Latching Circuit 303-16X 120/208VAC, 303X with conformal coating DC 310DCX 28VDC, 28-36V Range 310DC-HX 28VDC, 28-36V Range, 125VDC 2A Contacts 310DC-SX 28VDC, 28-36V Range, 2A Contacts, High Shock 310DC-2X 28VDC, 28-36V Range, T.D., MIL-E-7894 Fig. 2 310DC-3X 28VDC, 35-46V Range, T.D., MIL-E-7894 310DC-4X 28VDC, Set 31V, 2 Sec; 40V, 0.2 Sec. 311DCX 12VDC, 12-16V Range 311DC-1X 12VDC, 12-16V Range, 1V Differential 320DCX 60VDC, 60-85V Range 320DC-HX 60VDC, 60-85V Range, 125VDC 2A Contacts 320DC-1X 35-60VDC, Spike Suppression 320DC-2X 55-80VDC, Spike Suppression 320DC-4X 48VDC, 48-70V Range 320DC-5X 20-70VDC, 120VAC Control 330DCX 120VDC, 120-160V Range 330DC-HX 120VDC, 120-160V Range, 125VDC 2A Contacts 330DC-1X 120VDC, 110-150V Range 330DC-2X 120VDC, 150-190V Range 340DCX 240VDC, 240-300V Range 340DC-HX 240VDC, 240-300V Range, 125VDC 2A Contacts 340DC-1SX 200VDC, 240-300V Range, Non-Mag., High Shock 350DCX 305VDC, 280-400V Range 350DC-HX 305VDC, 280-400V Range, 125VDC 2A Contacts 350DC-1SX 250VDC, 280-400V Range, Hi-Shock, 120VAC Control 360DCX 405VDC, 400-470V Range 360DC-HX 405VDC, 400-470V Range, 125VDC 2A Contacts AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS 360DC-1X 405VDC, 400-470V Range, Spike Suppression 360DC-2X 475VDC, 475-550V Range 360DC-3X 550VDC, 550-600V Range 360DC-4X 350VDC, 350-440V Range, Bi-Directional 360DC-4HX 350VDC, 350-440V Range, Bi-Directional 370DCX 620VDC, 600-670V Range 370DC-2X 550VDC, 550-650V Range 370DC-1X 610VDC, 600-800V Range, 120VAC Control 370DC-3X 610VDC, 800-1000VDC Range 370DC-5X 960VDC, 900-1000VDC Range AC, SINGLE PHASE, 50/60 HZ, SPECIALS 400X 120VAC 400HX 120VAC, Sim. to 400X with 125VDC 3A Contacts 400SX 120VAC, Hi-Shock, 10A Contacts 400-1X 120VAC, 55-72V Range 400-1HX 120VAC, Sim. to 400-1X, 125VDC 3A Contacts 400-S-1 450VAC, 240-350V Range, Hi-Shock, T.D. 400-2X 120VAC, 0.017 Sec. T.D. 400-S-2 440VAC, 280-420V Range, Hi-Shock, T.D. 400-3X 120VAC, 4.8 Sec. T.D., 80-115V Range 400-S-3 440VAC, 280-420V Range, Hi-Shock, T.D. 400-4X 240VAC, 170-240V Range 400-S-4 440VAC, Sim. to 400-2SX, 2-3 Sec. T.D., D.O. 160V 400-5X 450VAC, 320-450V Range 400-5SX 450VAC, 70-100% Range, Hi-Shock, 10A Contacts 400-6X 120VAC, 90-123V Range 400-7X 277VAC, 190-290V Range 400-8X 120VAC, 55-80V Range 400-8SX 120VAC, 50-70% Range, Hi-Shock 400-9X 480VAC, 320-480V Range 400-10X 120VAC, 1.0 Sec. T.D. with power loss 400-11X 480VAC, 1.0 Sec. T.D., 320-480V Range 400-12X 120VAC, Similar to 400-10X except 1 N.O. & 1 N.C. 400-13X 120VAC, 14-30V Range 400-14X 67VAC, 30-67V Range, Suppression 400-16X 120VAC, 0.6 Sec. T.D., 50-420 Hz 400-17X 120VAC, Similar to 400-2 with seismic 400-19X 120VAC, 125VDC 2A Contacts, Suppression 400-20X 208VAC, 24-48V Range 400-21X 120VAC, 94.8-102V Range, 6 +/-2 Sec. T.D. 400-23X 480VAC, 320-480V Range, 2.0 Sec. T.D. 400-24X 120VAC, 2.0 Sec. T.D. 400-25X 240/480VAC, 3-30Sec. T.D., Latching 400-26X 480VAC, 160-200V Range 400-27X 460VAC, 250-350V Range, 0.3 Sec. T.D., Set to 76V 400-28X 0.5VAC, 0.5-1.0V Range, 115VAC Control 400-29X 120VAC, 0.15 Sec. T.D., 10A Contacts 400-30X 24VAC, 18-24VAC Adjustable 400-31X 120VAC, 105-135V Range 400-32X 120VAC, 1 Ph. T.D. 0-10 Sec. 400-33X 480VAC, 1 Ph. T.D., 0-10Sec. 400-34X 120VAC, 55-72V Range, 2 N.O. Contacts 400-35X 120VAC, Similar to 400X, but 2 N.C. Contacts Protective Relays Additional Relays (Continued) AC, SINGLE PHASE, 400 HZ 402X 120VAC 402-SX 120VAC, Hi-Shock, NSN 5945-00-258-6662 402-1X 240VAC, 170-240V Range 402-1SX 240VAC, High Shock 402-2X 120VAC, 90-120V Range, 0.3 Sec. T.D., Set to 96V 402-3X 120VAC, Similar to 402-2X with 10A Contact 402-4X 120VAC, Similar to 402-2X with 0.15 Sec. T.D. AC & DC, SINGLE PHASE, CLOSE DIFFERENTIAL D100-10X 120VAC, 50-500Hz, -40 to +75 deg. C D100-13X 450VAC, D.O. 60-100%, P.U. 66-100% D100-15X 120VAC, 50-500Hz, 125VDC, 1 Amp Contacts D100-16X 208VAC, 50-500Hz, 125VDC, 1 Amp Contacts D100-17X 120VAC, 50-500Hz, 450VAC Input Capacitor, GE D100-18X 120VAC, Hi-Shock, D.O. 72-84, P.U. 102-114 Range D100-19X 120VAC, Hi-Shock, D.O. 80-120, P.U. 80-120 Range D100-20X 150VAC, 105-150V Range D100DCX 60 VDC, 48-55VDC Range, 1.5 Sec. T.D. D100DC-15X 120VDC, 80-120VDC Adjust,0.4V Differential D100DC-16X 60VDC, 40-60VDC Adjust, 0.2V Differential D100DC-18X 40VDC, 20-40VDC Adjust, 120VAC Control D100DC-19X 140VDC, 100-140VDC, 0.4V Differential D100DC-22HX 120VDC, 80-120VDC Range, 120VDC Contacts D100DC-23X 260VDC, 195-260VDC Range D100DC-35X 30-40VDC Range, Plug-in, NSN 5945-00-650-8613 D100DC-36X 48VDC, Adjustable 38-48VDC D100DC-37X 75VDC, 50-80VDC Range, 0.5A, 74VDC Contacts D100DC-38X 270VDC, 190-270VDC Range, Similar to D100DC-23 D100DC-39X 28VDC, Adjustable 15-30VDC D100DC-40X 28VDC, Approx. 2.0 Sec T.D. AC, THREE PHASE, 50/60 HZ, SPECIALS 401X 120/208VAC, 4W, 85-120V Range 401-HX 120/208VAC, 4W, 125VDC 3A Contacts 401-1X 240VAC, 4W, 182-244V Range (L-L) 401-2X 480VAC, 4W, 360-485V Range (L-L) 401-2HX 480VAC, 3 or 4W, 125VDC 3A Contacts 401-3X 220VAC, 3W, 160-200V Range (L-L) 401-4X 380VAC, 4W, 150-220V Range (L-N) 401-5X 120VAC, 4W, 90-120V Range (L-L) 401-6X 120VAC, 3W, 85-120V Range (L-L) 401-7X 480VAC, 4W, 332-407V Range (L-L) 401-8X 100VAC, 3W, 70-100V Range (L-L) 401-9X 120/208VAC, 4W, Fast Operating 401-9HX 120/208VAC, 4W, 0.02S T.D., 125VDC 3A Cont. 401-10X 480VAC, 3W, 360-485V Range 401-10HX 480VAC, 3W, 125VDC 3A Contacts 401-11X 240VAC, 3W, 180-240V Range 401-11HX 240VAC, 3W, 125VDC 3A Contacts 401-12X 120/208VAC, 4W, 1.0 Sec. T.D. 401-12HX 120/208VAC, 4W, 1.0 Sec. T.D., 125VDC 3A Contacts 401-13X 380VAC, 3W, 1.0 Sec. T.D. 401-14X 480VAC, 4W, 0.5 Sec. T.D. 401-15X 120/208VAC, Sim. to 401X with 6” leads and socket 401-16X 380VAC, Sim. to 401-4X with 6” leads and socket 401-17SX 120/208VAC, 4W, 10 Sec. T.D., Solar 401-18X 480VAC, 3W, 2.0 Sec. T.D., 90% P.U., 70% D.O. 401-19X 120/208VAC, Sim. to 401X with 2KV Diodes, Supp. 401-20X 69/120VAC, 4W, 25-35V Range, 4KV Diodes, Supp. 401-21X 120/208VAC, 4W, 85-120V Range, 0.05 Sec. T.D. 401-22X 480VAC, 3 or 4W, 5.0 Sec. T.D. 401-23X 120VAC, 3W, 0.05 Sec. T.D. 401-24X 120VAC, 3W, 2 N.C. Contacts 401-25SX 120VAC, 3W, 10Sec. T.D., Solar 401-26X 67/115VAC, 4W, Suppression 401-28X 120/208VAC, 4W, 60-100V Range, Set at 90V 401-29X 120VAC, 4W, 90-120V Range, 1.0 Sec. T.D. 401-29HX 69/120VAC, 4W, 1.0 Sec. T.D., 125VDC 3A Contacts 401-30X 480VAC, 3W, 360-480V Range, 2.0 Sec. T.D. 125VDC 3A Contacts 401-31SX 94VAC, 3W, 10 Sec. T.D., Solar 401-33X 480VAC, 4W, 139-231V Range (L-N) 401-34X 120/208VAC, 4W, 2-3 Sec. T.D. 401-35X 208VAC, 3W, 0.008 Sec. T.D., 28VDC Control 401-36X 480VAC, 3W, 0.008 Sec. T.D., 28VDC Control PAGE 37 11 Protective Relays 400-36X 120VAC, Similar to 400-24X, 1 N.O., 1 N.C. Contact 400-37X 120VAC, Similar to 400X, with Suppression 400-38X 120VAC, 85-120V, 1-20 Sec. T.D., Instant. at 50V 400-38PX 120VAC, Similar to 400-38X with Spike Protection 400-39X 120VAC, 1.0 Sec. T.D., Transient Protection 400-40X 120VAC, 0.083 Sec. T.D. 400-41X 120VAC, Similar to 400X with 2 N.O. Contacts 400-43X 240VAC, 120-240V Range 400-44X 208VAC, 150-210V Range 400-47X 380VAC, Fast Operating, 220VAC 5A Contacts 400-49X 120VAC, 55-80V Range, 125VDC Contacts 400-50X 480VAC, 320-480V Range, 125VDC 1A Contacts 400-51X 120VAC, Sim. to 400-38X with 1-30 Sec. T.D. 400-52X 120VAC, 55-80V Range, 125VDC 2A Contacts 400-53SX 450VAC, 110-300V Range, 120V Control 400-54X 120VAC, Sim. to 400-13X with 1.0 Sec. T.D. 400-55X 208VAC, 125-208V, 24VDC Ctrl., 1 N.O. Contact 400-56X 208VAC, 24-48V Range, 2 N.O. Contacts 400-57X 120VAC, 25 Hz, 84-120V, 125VDC 3A Contacts 400-58X 277VAC, 194-277V Range, 0.020 Sec. T.D. 400-59X 139VAC, 97-159V Range 400-60X 240VAC, 84-120V Range 400-6lPX 120VAC, Similar to WUV-1-120P 400-62X 120VAC,30-42V Range, 125VDC Contacts 400-63X 120VAC,30-42V Range, 120VAC Contacts Protective Relays Additional Relays (Continued) 401-37X 120VAC, 3W, 5.0 Sec. T.D. 401-38X 380VAC, 3W, 0.05 Sec. T.D. 401-39X 480VAC, 4W, 250-550V Range (L-L) 401-41X 240/416VAC, 4W, 312-416V Range (L-L) 401-41HX 230/400VAC, 4W, 125VDC 3A Contacts 401-42X 120/208VAC, 4W, 5.0 Sec. T.D. 401-43SX 480VAC, Sim. to 403-7SX except 60 Hz. 401-44X 139/240VAC, 4W, 2.0 Sec. T.D. 401-45X 120VAC, 3W, 85-120V Range (L-L), 125VDC Contacts 401-46X 480VAC, Similar to 401-2X with Suppression 401-47X 380VAC, 3W, 2.0 Sec. T.D. 401-48X 208VAC, 3W, 145-208V Range 401-49X 20.8VAC, 3W, 15.5-20.8V Range 401-50X 120VAC, 3W, 0-10 Sec. T.D. 401-51SX 90/156 VAC, 4W, Similar to 401-17SX 401-52X 480VAC, 3W, Sim. to 401-10X 401-53X 120/208VAC, 4W, 1 N.O., 1 N.C. 401-54X 400VAC, 3W, 300-400V Range 401-55X 600VAC, 3W, 480-600V Range 401-58X 120/208VAC, Sim. to 401X except 2 N.C. Contacts 401-59X 220-380VAC, Dual Voltage 220V or 380V 401-60X 480VAC, 1 N.O., 1 N.C. Contact, 2-3 Sec. T.D. 401-61X 120VAC, 3W, 85-120V Range (L-L), 1.0 Sec. T.D. 401-62X 380VAC, 3W, 220VAC 5A Contacts 401-63X 120VAC, 3W, Sim. to 401-6X with Suppression 401-67X 120/208VAC, 4W, 1.0 Sec. T.D., -55F to +150F 401-68X 120VAC, 3W, 85-120V Range, 2-3 Sec. T.D. 401-69X 120/208VAC, 4W, 85-120V Range, Lowest of 3 401-70X 133/230VAC, 4W, 99-133V Range, Lowest of 3 401-71X 220/380VAC, 4W, 154-220V Range, Lowest of 3 401-72X 266/460VAC, 4W, 186-266V Range, Lowest of 3 401-74X 66/115VAC, 4W, 65-75% Adj., Supp., 125VDC Cont. 401-75X 115/200VAC, 3W, 65-75% Adj., Suppression 401-76SX 450VAC, 3W, 382-450V, 0.3-0.5S T.D., Hi-Shock 401-77X 120/208VAC, 4W, 0.5-10 Sec. T.D., Lowest of 3 401-79X 480VAC, 3W, 0.2-0.3 Sec. T.D., Suppression 401-80X 76VAC, 3W, 53-76V Range 401-81X 120/208VAC, Sim. to 401-12X with 48VDC Contacts 401-82X 104VAC, 3W, Similar to WUV-3-104 401-83SX 120/208VAC, MIL-R-2033A 401-84X 180VAC, 3W, Similar to WUV-3-180 401-85SX 480VAC, Similar to 401-25SX except 480V 401-86SX 380VAC, Similar to 401-25SX except 380V 401-87SX 240VAC, Similar to 401-25SX except 240V 401-90X 120/208VAC, 4W, 0.5 Sec. T.D. 401-93X 480VAC, 3W Fast Oper. 50mS., Suppression 401-97X 69/120VAC, Lowest of 3 401-98X 480VAC, Sim. to 401TD-9HX with 2.0 Sec. T.D. 403X 403-1X 403-1SX 403-2X 403-3X 403-4X 403-5X AC, THREE PHASE, 400 HZ 120/208VAC, 4W 115/200VAC, 4W, 35-400mS T.D. 115VAC, 3W, Hi-Shock 120VAC, 3W 120/208VAC, 4W, 1.0 Sec. T.D. 254/440VAC, 4W 120/208VAC, 4W, 2 N.C. Contacts AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS 403-7SX 480VAC, 3W, T.D., Hi-Shock 403-10X 120/208VAC, 4W, 10A Contacts 403-11X 480VAC, 4W, 60% to 80% Range 403-13X 120/208VAC, 4W, 0C to +90C 403-14X 575VAC, 3W, 400-500V Range 403-15X 120/208VAC, Sim. to 403-13X with Latching Circuit 403-16X 120/208VAC, Sim. to 403X with Conformal Coating AC THREE PHASE, CLOSE DIFFERENTIAL D101-3X Similar to D101X, -55C to +85C D101-5X 120VAC, 50-500Hz, Military D101-9X 120VAC, 50-500Hz, 0.5 Sec. T.D. D101-11X 120VAC, 50-500Hz, 120-150VAC Adjust, N.C. Cont. D101-12X 120VAC, Similar to D101X but 60-120VAC Range D101-13X 120VAC, Similar to D101X but 3 N.C. Contacts D101-14X 208VAC, Similar to D101-6X but 3 N.C. Contacts D101-15X 480VAC, 50-500Hz, Spike Suppressors D101-16X 480VAC, Similar to D101-7X but 3 N.C. Contacts D101-17X 120VAC, 0.4A 120VDC Contact, -20 to +85 deg C D101-18X 120VAC, Similar to D101X but Spike Suppression D101-19X 208VAC, Similar to D101-6X but Spike Suppression D101-20X 240VAC, Similar to D101-4X but Spike Suppression D101-21X 380VAC, Similar to D101-10X but Spike Suppression D101-24X 240VAC, 3 N.C. Contacts D101-25X 208VAC, 3 N.C. Contacts, Spike Suppression D101-26X 277VAC, 50-500Hz, 66-100% Adjustable D101-27X 120VAC, Sim. to D101X, withstand 208V continuous D101-29X 415VAC, 50-500Hz D101-30X 380VAC, 50-500Hz, 3 N.C. Contacts D101-31X 525VAC, Spike Suppression D101-32X 120VAC, 50-500Hz, 5 Sec T.D. DC 400DCX 120VDC, 85-120V Range 400DC-HX 120VDC, 85-120V Range, 125VDC 2A Contacts 400DC-lX 28VDC, 15-29V Range 400DC-2X 240VDC, 180-220V Range 400DC-3X 62.5VDC, 40-65V Range 400DC-4X 305VDC, 200-300V Range 400DC-5X 5.6VDC, 4-6V Range, 120VAC Cont 410DCX 28VDC, 16—29V Range 410DC-SX 28VDC, 16-29V Range, Hi-Shock, MIL-R-57 410DC-1X 28VDC, 15-32V Range, 1.5V Differential 410DC-5X 24VDC, 16-29V Range, Suppression 410DCTDX 28VDC, 0.5-20 Sec. T.D. 411DCX 12VDC, 9-12 V Range 411DC-1X 15VDC, 11-15V Range 411DCTDX 12VDC, 0.5-20 Sec. T.D. 420DCX 60VDC, 40-65V Range Protective Relays Additional Relays (Continued) 420DCTDX 430DCTDX 440DCTDX DC TIME DELAY 48VDC, 32-48V Range, 0.5-20 Sec. T.D. 125VDC, 83-125V Range, 0.5-20 Sec. T.D. 250VDC, 166-250V Range, 0.5-20 Sec. T.D. OVER/UNDERVOLTAGE RELAYS AC, SINGLE PHASE 250SX 120VAC, Hi-Shock 250-1X 120VAC, 72-120V, Mil, NSN 6125-00-091-0969 250-2X 120VAC, 1.2 Sec. Time Delay 250-3X 67VAC, UV 30-67V, OV 67-91V 250-4X 26VAC, 28VDC Control, Connector 250-5X 240VAC, Two N.C. Contacts 250-6X 240VAC, One N.O., One N.C. Contact 250-6HX 240VAC, 120VDC, 3A Contact 250-7X 120VAC, 3 Sec. Time Delay 250-8X 100VAC 250-10X 120VAC, Fast Trip, 25mS 250-11X 120VAC, Set at 97V and 156V 250-12X 120VAC, Sim. to 250X, MIL-R-5757 2A 250-14XAC 67VAC, Sim. to 250-3X with removable cover 250-17X 120VAC, Sim. to 250X plus suppression 250-19X 120VAC, Sim. to 250X with 2 N.O. Contacts 250-22X 240VAC, 1-2 Sec. TD on Drop Out 250-23X 120VAC, Sim. to 250X but -40C to +52C 250-27X 139VAC, Same as 250-12X except voltage 250-28X 138VAC, Same as 250-10X except voltage 250-29HX 120VAC, 50-400Hz., 125VDC 3A Contacts 250-30X 480VAC 250-31X 240VAC, Fast Trip 25mS 250-32HX 480VAC, 100Hz, 1Sec TD, 120V 3ADC Contacts 250-33HX 480VAC, 25Hz, 1 Sex TD, 120V 3ADC Contacts 250-34X 120VAC, 72-120-160V Range, Hi Shock 250-35X 230VAC, Sim. to 250-22X, 3.0 Sec. TD 250-36X 120VAC, 84-120-150V Range, Hi Shock, -40C to 70C 250-37HX 120VAC, 25 Hz, 1 Sec. TD, 120V 3ADC Contacts 250-38X 240VAC, Two N.O. Contacts 250-39X 120VAC, Similar to 250X, Range +/- 35% AC, SINGLE PHASE, 50-400HZ 251SX 120/208VAC, Sim. to 251X with Hi Shock 251-1X 120/208VAC, 4W, 0.50 Sec. TD NSN 5895-00-139-0337 251-4X 139/240VAC, 4W 251-5X 120/208VAC, 4W, Two N.C. Contacts 251-8X 120/208VAC, 4W, 1.2 Sec. TD 251-10X 110/190VAC, 4W 251-13X 120/208VAC, Sim. to 251X except -40C to 52C 251-14X 120/208VAC, 4W, Withstand 220/380V Continuous 251-15X 120/208VAC, Sim. to 251X with Transient Protection 251-16X 120/208VAC, 1.2 Sec. TD, Transient Protection 251-17X 120/208VAC, Similar to 251X, 208V 7.5A Contacts 251-18X 120/208VAC, Highest/Lowest of three, TD Adjust 12VDC control 251-19X 120/208VAC, Highest/Lowest of three, TD Adjust 120VAC control 251-20X 120/208VAC, Highest/Lowest of three, TD Adjust, 24VDC Control 251-21X 120/208VAC, Sim. to 251X, 0.5Sec. TD 251-22X 115/200VAC, Sim. to 251X, 0.75Sec. TD 253-HX 230VAC, 3W, 48VDC 3A Contacts 253-1X 230VAC, 3W, Spike Suppression 253-1HX 230VAC, 3W, Spike Suppression, 125VDC Contacts 253-3X 230VAC, 3W, 1.0 Sec. TD 253-5X 230VAC, 3/4W, 2 N.C. Contacts, -51C to +71C 253-6X 230VAC, 3W, 3.0 Sec. TD 254-1X 415VAC, 3W, 290-415-519V 254-2X 220/380VAC, 4W, 2 N.C. Contacts 254-3X 416VAC, 3/4W, 2 N.C. Contacts, -51C to 71C 255-HX 460VAC, 3W, 125VDC 3A Contacts 255-1X 460VAC, 3/4W, Spike Suppression 255-2X 480VAC, 3W, High Shock 255-3X 495VAC, 3W, 3.0 Sec. TD PAGE 39 11 Protective Relays 420DC-4X 48VDC, 32-48V Range 420DC-5X 48VDC, 20-48V Range 420DC-6X 70VDC, 50-70V Range 420DC-8X 32VDC, 33-40V Range (Pick-Up) 420DC-9X 48VDC, Similar to 420DC-4X with 2 N.O. Contacts 420-470 SUFFIX SUFFIX : “A” 2 N.O. Contacts “B” 2 N.C. Contacts 430DCX 120VDC, 85-120V Range 430DC-HX 120VDC, 85-120V Range, 125VDC 3A Contacts 430DC-1X 140VDC, 105-140V Range 430DC-2X 140VDC, 105-140V Range, 0.5 Sec. T.D., Suppression 430DC-3X 120VDC, 50-80V Range 430DC-4X 120VDC, 85-120V Range, 0.5 Sec. T.D., Set at 90V 430DC-5X 125VDC, 90-125V Range, Spike Suppression 430DC-6X 125VDC, 105-140V Range, 3.0-5.0 Sec. T.D. 430DC-7X 170VDC, 120-170V Range 430DC-8X 120VDC, 85-120V Range, 2 N.C. Contacts 430DC-9X 100VDC, 35-50V Range 430DC-10X 120VDC, 85-120V Range, 2 N.O. Contacts 440DCX 240VDC, 168-240V Range 440DC-HX 240VDC, 168-240V Range, 125VDC 3A Contacts 440DC-1X 280VDC, 190-260V Range 450DCX 305VDC, 230-305V Range 450DC-HX 305VDC, 230-305V Range, 125VDC 3A Contacts 450DC-1X 305VDC, 230-305V Range, 2 N.C. Contacts 460DCX 405VDC, 315-415V Range 460DC-HX 405VDC, 315-415V Range, 125VDC 3A Contacts 460DC-1X 405VDC, 300-330V Range 460DC-3X 405VDC, 300-425V Range 460DC-4X 432VDC, 275-325V Range 460DC-5X 470VDC, 300-425V Range 470DC 560VDC, 400-500V Range 470DC-1X 585VDC, 400-500V Range Protective Relays Additional Relays (Continued) 255-4X 460VAC, 3W, 2 N.O. Contacts, EMD # 9333490 255-5X 460VAC, 3W, Sim. to 255-4X, MIL-R-5757, 10A Relay 255-6X 460VAC, 3W, EMD# 9337151 255-7X 460VAC, 3W, Sim. to 255X, Fast operating, 40mSec. 255-8X 480VAC, 3W, 5.0 Sec. fixed TD, 120VAC Control 255-9X 480VAC, 3W, Sim. to 255-8X except +/- 10% Setting AC, SINGLE PHASE, 50-400HZ 256-1X 600VAC, 3W, 60Hz, 2 N.O. Contacts, EMD Canada 256-2X 575VAC, 3W, GM# 6964912 Rev. A DC 250DC-HX 24VDC, 16-24-30V Range, 48VDC 3A Contacts 250DC-1X 28VDC, MIL Shock and Vibration 250DC-2X 26VDC, UV 20-30V, OV 26-36V 250DC-3X 28VDC, 20-28-35V Range, Hi Shock, -40C to 70C 250DC-4X 14VDC, Commonwealth Edison 250DC-5X 28VDC, Commonwealth Edison 251DC-1X 48VDC, Removable Cover 251DC-2X 35VDC, UV 23-30V, OV 40-52V 251DC-3X 30VDC, UV 21-27V, OV 30-40V 251DC-HX 48VDC, 32-48-60V, 48VDC 3A Contacts 251DC-4X 60VDC, 45-60-75VDC, 2N.O. 120VAC Contacts 252DCX 120VDC, 85-120-150V Range 252DC-1X 130VDC, 80-130/120-150V Range 252DC-1HX 125VDC, 85-125/125-160V, 48VDC 3A Contacts 252DC-2X 130VDC, 80-130/120-150V, Removable Cover 253DCX 250VDC, 175-250-315VDC Range 253DC-HX 250VDC, 175-250-315VDC, 48VDC 3A Contacts REVERSE POWER RELAYS 710-HX 710-PX 710-1X 710-3X 710TD-1X 710TD-5X 710TD-7X 710TD-7PX 710TD-8X 710TD-9X 710TD-12X 710TD-14X 720TD-14X 721TD-14X 722TD-14X 723TD-14X 724TD-14X AC, SINGLE PHASE 120/220/266VAC, 125VDC 3A Control 120/220/266VAC, 0.2-1.0A, Spike Suppression 120/220/266VAC, 125VDC 1/4A Control 120VAC (L-N), 1 Phase, 3-5A 120/220/266VAC. SINGLE PHASE TIME DELAY 0.05-0.25A, 0.5-10 Sec. T.D. with Knobs 2 N.O. Contacts 60Hz, Reverse Inductive Similar to 710TD-7X with Suppression Similar to 710TDX with -55F to +150F Similar to 710TDX with Suppression Similar to 710TDX, 125VDC 2A Contacts 50Hz, Reverse Inductive 120 V, L-L, 50Hz, Reverse Inductive 230 V, L-L, 50Hz, Reverse Inductive 380 V, L-L, 50Hz, Reverse Inductive 460 V, L-L, 50Hz, Reverse Inductive 575 V, L-L, 50Hz, Reverse Inductive AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS 725TD-14X 726TD-14X 727TD-14X 415 V, L-L, 50Hz, Reverse Inductive 100 V, L-L, 50Hz, Reverse Inductive 185 V, L-L, 50Hz, Reverse Inductive PHASE SEQUENCE RELAYS AC, THREE PHASE 900-2PX 208-230VAC, Spike Suppression 900-4X 208VAC, 50/60 Hz 900-5X 120VAC, 50/60Hz 900-8X 120VAC, 60 Hz, 125VDC 2A Contacts 900-10X 120VAC, 60 Hz, Spike Suppression 901-1X 440VAC, 60 Hz, 5A Contacts 901-5X 575VAC, Porcelain Term., AZ Relay 901-6X 460VAC, 60 Hz, Spike Suppression 901-SX 440VAC, 55-65HZ, HI-Shock 910-1X 220/440VAC, 60 Hz, N.O. Contacts 910-2X 220/440VAC, 60 Hz, Reversed Contact Operation 910-3X 220/440VAC, 60 Hz, Porcelain Term., Sigma Relay 920X 380VAC, 50 Hz 920-1X 380VAC, 50 Hz, Mounting per 21-037 920-2X 380VAC, 50 Hz, Porcelain Terminals, Sigma Relay 920-3X 416VAC, 50 Hz, 5A Contacts 920-5X 220/380VAC, 50 Hz 920-6X 440VAC, 50 Hz 930X 208VAC, 400 Hz 930-1X 208VAC, 400Hz, 2A at 28VDC Contacts, Energized A-B-C, 5A 930-3X 400VAC, 400Hz 930-4X 400VAC, 2 N.C. Contacts, -51C to +71C 931X 120VAC, 400 Hz. 932-5X 115/200VAC, 400Hz, 2A Contact,Hi-Shock 932-7X 230/400VAC, 400Hz PHASE FAILURE RELAYS 980X 981X 982X 983X 984X 985X 120VAC, 60 Hz, no T.D. on Starting 230VAC, 60 Hz, no T.D. on Starting 460VAC, 60 Hz, no T.D. on Starting 380VAC, 60 Hz, no T.D. on Starting 575VAC, 60 Hz, no T.D. on Starting 525VAC, 60 Hz, no T.D. on Starting 1980X 120VAC, 60 Hz 1981X 230VAC, 60 Hz 1982X 460VAC, 60 Hz 1983X 380VAC, 50 Hz 1984X 575VAC, 60 Hz 1985X 525VAC, 60 Hz 1986X 415VAC, 50 Hz 1987X 380VAC, 60 Hz SUFFIX: “-S”: Time Delay (0.5 - 30 Sec.) “-3S”: Factory Set Time Delay (0-60 Sec.) 1981-1SX 230VAC, Similar to 1981X except 50 Hz 1980-2SX 120VAC, Similar to 1980X except N.C. Contacts AC, THREE PHASE, VOLTAGE SENSITIVE 1003X-60HZ 380VAC, Similar to 1003X except 60HZ 1009X 415VAC, 50 Hz 1010X 208VAC, 50 Hz Protective Relays Additional Relays (Continued) 1001X-1010X SUFFIX “-1”: N.C. Contact (example: 1004-1X) 1001X-1010X SUFFIX “-2”: -53C to +70C, 2% Drift below -20C 1001X-1010X SUFFIX “-3”: 400Hz, N.O. Contacts 1001X-1010X SUFFIX “-T’: Spike Suppression 1001X-1010X SUFFIX “-H’: 125VDC 3A Contacts 1001X-1010X SUFFIX “-9” 1 N.O. & 1 N.C. Contacts 1001X-1010X SUFFIX “-12”: Spike Supp., 125VDC 3A Contacts 1001X-1010X SUFFIX “-13”: 1N.O + 1 N.C. 125VDC 3A Contacts OVERCURRENT RELAYS AC, SINGLE PHASE, ADJ. DIFFERENTIAL D1100X 120VAC, 1-5A Range D1100-2X 220VAC, 1-5A Range D1100-3X 120VAC, 4-12A Range D1100-4X 230VAC, 4-12A Range D1100-5X 460VAC, 4-12A Range D1100-6X 120VAC, 1-5A Range, 1-2 Sec. T.D. D1100-7X 120VAC, 0.7-5A Range, 125VDC 0.5A Contacts D1100-8X 120VAC, 5-15A Range AC, SINGLE PHASE, TIME DELAY 1100TDX 120VAC, 1-5A Range, 0.5-30 Sec. T.D. 1100TD-HX 120VAC, 1-5A, 0.5-30 Sec. T.D., 125VDC 3A Cont. 1100TD-SX 120VAC, 1-5A Range, 0.5-20 Sec. T.D., Hi-Shock 1100TD-1X 240VAC, 1-5A Range, 0.5-30 Sec. T.D. 1100TD-2X 24VDC, 1-5AAC Range, 0.5-30 Sec. T.D. 1100TD-3X 120VAC, 0.5-5A Range, 0.5-30 Sec. T.D. 1100TD-5X 120VAC, 0.5-2.5A Range, 0.5-30 Sec. T.D. 1100TD-6X 120VAC, 1-5A , 0.2-20 Sec. T.D., Manual Reset 1100TD-8X 220VAC, 2-10A Range, 220VAC 5A Contacts AC, THREE PHASE, TIME DELAY 1130TDX 120VAC, 1-5A, 0.5-20 Sec. T.D. 1130TD-1X 24VDC, 1-5A, 0.5-20 Sec. T.D. 1130TD-2X 120VAC, 1-5A, 0.5-20 Sec. T.D., Suppression 1130TD-3X 120VAC, 1-5A, 0.5-60 Sec. T.D., 2 N.C. Contacts 1150X 120VAC, 4.35A, 0.5-5 Sec. T.D. 1150-1X 120VAC, 4.26A, 0.5-5 Sec. T.D. 1150-2X 120VAC, 3.72A, 0.5-5 Sec. T.D. 1150-4X 120VAC, 1-5A, (P.G.E.) 1150-6X 120VAC, 1-5A, 2-3 Sec. T.D. on D.O. 1150-8X 120VAC,Same as 1150-2X with 2 N.O. Contacts 1150-10X 120VAC, 1-5A, 2 Sec. T.D. 1150-10SX 120VAC, 1-5A, 2 Sec. T.D., Hi-Shock 1150-11X 120VAC, 2.5-5A, 400Hz, Special T.D. Curve 1150-12X 120VAC, 2.5-5A, 60Hz, Special T.D. Curve 1150-14X 120VAC, 2.5-5A, 400Hz, T.D. Curve, Aux. N.O. 1150-15X 24VDC, 1.2-2.2A, 60Hz, T.D. Curve, (Solar) 1150-16X 24VDC, 2.5-4.3A, 60Hz, T.D. Curve, (Solar) VOLTAGE RESTRAINT 1200X 120VAC, 1-5A, 24VDC Control 1200-1X 120VAC, 1-5A, 12VDC Control 1200-4X 120/208VAC, 1-5A, 3 Phase, 24VDC Control 1200-5X 120VAC, 1-5A, 3 Phase, 24VDC Control 1200-6X 120VAC, 1-5A, 3 Phase, 24VDC Control, Suppression 1200-7X 120VAC, 1-5A, 1 Phase, 120VAC Control 1200-8HX 120VAC, 1-5A, 3 Phase, 125VDC Control DC 1100DCX 120VAC, 10-50mV ext. Shunt, 5A Contacts 1100DC-1X 230VAC, 0-10VDC ext. Shunt, 5A Contacts 1100DC-2X 120VAC, 10-50mV ext. Shunt, Transistor Output 1100DC-3X 120VAC, 0.2-0.6ADC with 0.125 ohm Shunt 1100DC-4X 28VDC, 10-50mV, Inverter, ext. Shunt, 2 Sec. T.D. 1100DC-6X 125VDC, 10-50mV, Inverter, 125VDC 3A Contacts 1100DC-7X 120VAC, 10-50mV, Inverter, 125VDC 3A Contacts 1100DC-8X 120VAC, isolated outputs 1100DC-9X 250VDC, 150mV Shunt, Hi-Shock, +/- 20% Adj. 1100DC-10X 120VAC, 50-150mV 1100DC-11X 220VDC, 5-25mV, 1-25 Sec. T.D., Inverse Current 1100DC-13X 120VAC, 20-35mV, Hi-Shock 1100DC-15X 12VDC, 10-50mV, Inverter 1100DC-17X 74VDC, 10-50mV, Inverter 1100DC-20X 120VAC, Similar to 1100DCX except 4-25mV PAGE 41 11 Protective Relays 1100X 120VAC, 1-5A Range 1100-1X 120VAC, 0.5-5A Range, Remote Adjust 1100-2X 120VAC, 0.5-5A Range 1100-2SX 120VAC, 0.5-5 A Range, Hi-Shock, 2A Contacts 1100-9X 120VAC, 1-5A, Fast Operating 1100-11X 120VAC, 1-5A, 3% Diff., Suppression 2.5KV 1100-13X 120VAC, 1-5A, 2 N.C. Contacts 1100-14X 120VAC, 7-30A, 2 N.C. Contacts 1100-15X 120VAC, 2-10A, 2 Sec. T.D. 1100-17X 120VAC, 1-5A, 2 Sec. T.D. 1100-18X 120VAC, 0.05-0.15A, 5A Max, 400 Hz 1100-19X 24VDC, 1-5A Range 1100-20X 120VAC, 1-5A, Suppression (15 times in-rush) 1100-21X 74VDC, 7-30A, 50mS T.D., Shock & Vibration 1100-22X 120VAC, 1-5A Remote Adjust 1100-23X 125VDC, 0.25-1.8A, 1 N.O. 125VDC 2A Contact 1100-24X 32VDC, 1-5AAC Range 1100-25X 120VAC, 0.25-1.25A 1100-26X 120VAC, 0.3-1.5A, Withstand 5A 1100-27X 220VAC, 1-5A Range, 220VAC Contacts 1100-32X 120VAC, Undercurrent 1-10A Adj, 0.2-5 Sec. T.D. 1100-35X 120VAC, 0.1-0.4A Range 1100-36X 74VDC, 4-20A, 50mS T.D., Shock & Vibration 1100-37X 24VDC, 0.1-0.3A Range 1100-38X 74VDC, Similar to WC1-74DC-5 1100TD-9X 24VDC, 0.5-5AAC Range, 0.5-20 Sec. T.D. 1100TD-10X 120VAC, Sim. to WCT1-120AC-5 w/ removable cover 1100TD-11X 120VAC, Sim. to WCT1-120AC-5, 1-5 Min. T.D. 1100TD-12X 120VAC, Sim. to WCT1-120AC-5, 0.5-5 Sec. T.D. OPTION 1: 0.2A to 1.0A Range 2.5: 0.5A to 2.5A Range 5: 1.0A to 5.0A Range 10: 2.0A to 10.0A Range Protective Relays Additional Relays (Continued) UNDERCURRENT RELAYS 21-693-1 21-693-2 Self Contained CT, 120VAC Control Self Contained CT, 230VAC Control 2800-480 480VAC, Ph. Ang. 5-25 deg., UV: 70% D.O. 80% P.U. 2800-600 600VAC, Ph. Ang. 5-25 deg., UV: 70% D.O. 80% P.U. CURRENT DIFFERENTIAL 1350X 24VDC, 0.1-0.5A Range 1350PX 24VDC, 0.1-0.5A Range, Suppression, 1 N.O. Contact 1350SX 24VDC, 0.1-0.5A Range, High Shock 1350-1X 24VDC, 0.1-0.5A Range, 1 N.C. Contact 1350-3X 48VDC, 0.1-0.5A Range 1351X 120VAC, 0.1-0.5A Range 1351PX 120VAC, 0.1-0.5A Range, Suppression 1351SX 120VAC, 0.1-0.5A Range, High Shock 1351-1X 120VAC, 0.1-0.5A Range, 1 N.C. Contact 1351-2X 120VAC, 2 Sec. T.D. on application of voltage 1351-4X 120VAC, 0.1-0.5A Range, Fast, 125VDC Contacts PARALLELING (SYNCHRO-CHECK) RELAYS 1880X 1890X SUFFIX 200VAC, 1 N.O. & 1 N.C. Contact 90VAC, 1 N.O. & N.C. Contact “-A”: Two Normally Open Contacts “-B”: Two Normally Closed Contacts “-P”: Spike Suppression “-7”: 0.025 Second Time Delay “-9”: 125VDC 2A Contacts “-13”: 0.250 Second Time Delay 1880DBX 1890DBX SUFFIX DEAD BUS TYPE 200VAC, 1 N.O. & 1 N.C. Contact 90VAC, 1 N.O. & 1 N.C. Contact “-A”: 2 Normally Open Contacts “-B”: 2 Normally Closed Contacts “-S”: High Shock “-2”: 2 N.O. Contacts, Cond. 5 same as 3 “-3”: Condition 1 reversed “-5”: 12 deg. to 36 deg. adjustment “-8” 3 Phase, Phase Sequence “-9”: 125VDC 2A Contacts “-12”: 25 Hz, 125VDC 3A Contacts DOUBLE DEAD BUS (EITHER BUS DEAD) 1880DDBX 200VAC, 1 N.O. & 1 N.C. Contact 1890DDBX 90VAC, 1 N.O. & 1 N.C. Contact SUFFIX “-A”: 2 Normally Open Contacts “-B”: 2 Normally Closed Contacts “-9”: 125VDC Contacts; 2A res. , 1A ind. DOUBLE DEAD BUS, UNDERVOLTAGE 2800-120 120VAC, Ph. Ang. 5-25 deg., UV: 70% D.O. 80% P.U. 2800-208 208VAC, Ph. Ang. 5-25 deg., UV: 70% D.O. 80% P.U. 2800-240 240VAC, Ph. Ang. 5-25 deg., UV: 70% D.O. 80% P.U. 2800-380 380VAC, Ph. Ang. 5-25 deg., UV: 70% D.O. 80% P.U. 2800-416 416VAC, Ph. Ang. 5-25 deg., UV: 70% D.O. 80% P.U. 2800-440 440VAC, Ph. Ang. 5-25 deg., UV: 70% D.O. 80% P.U. AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS 2850X 2850-1X PHASE BAND MONITOR 208/230/460 V, 5-60 deg. Range, 60 Hz 208/240/380/480 V, 5-45 deg. Range, 50/60 Hz OVERFREQUENCY RELAYS WOF-12-100110 23-050X 23-060X 23-400X 120VAC, 100-110 Hz. Range SUFFIX “-1”: 0.2% Max. Differential “-T”: 0.5-20 Sec. Time Delay “-2T”: 60 Second Time Delay “-S”: High Shock 120VAC, 50-60 Hz 120VAC, 60-70 Hz 120VAC, 400-450 Hz UNDERFREQUENCY RELAYS 22-050X 22-060X 22-400X 120VAC, 50-60 Hz 120VAC, 60-70 Hz 120VAC, 400-450 Hz FREQUENCY RELAYS (Over or Under) 25-050HX 120VAC, 40-50-60 Hz, 125VDC 3A Contacts 25-050SX 120VAC, 40-50-60 Hz, High Shock 25-050-1X 120VAC, 40-50-60 Hz, 2 N.C. Contacts 25-050-2X 120VAC, 40-50-60 Hz, 1.2 Sec. Time Delay 25-060HX 120VAC, 50-60-70 Hz, 125VDC 3A Contacts 25-060SX 120VAC, 50-60-70 Hz, High Shock 25-060-1X 120VAC, 50/60 Hz +/-10% on each Frequency 25-060-2X 120VAC, 50-60-70 Hz, 0.4 Hz Differential 25-060-3X 120VAC, 50-60-70 Hz, 2 N.C. Contacts 25-060-4X 120VAC, 50-60-70 Hz, 2 N.O. Contacts 25-060-5X 120VAC, 50-60-70 Hz, 2 N.O, 10A MIL-R-5757 25-060-7X 120VAC, EMD #9337150, Set 57.4 & 62.6 +/-0.6 Hz 25-060-8X 120VAC, 50-60-70 Hz, 1 Sec. T.D. 25-060-10X 120VAC, Spike Suppression 25-060-12X 104VAC, 50-60-70 Hz 25-060-14X 240VAC, 50-60-70 Hz 25-060-18X 120VAC, 50-60-70 Hz, 1 Sec. T.D., Suppression 25-060-19X 120VAC, 50-60-70 Hz, 0.5-10Sec. T.D., 12VDC Ctrl. 25-060-20X 120VAC, 50-60-70 Hz, 0.5-10Sec. T.D., 24VDC Ctrl. 25-100X 120VAC, 90-100-110 Hz 25-400X 120VAC, 350-400-450 Hz 25-400-2X 120VAC, 350-400-450 Hz, 220VAC 5A Contacts 25-400-5X 120VAC, 350-400-450 Hz, Suppression 25-025T-1HX 480VAC, 20-25-30 Hz, 0.5-20Sec T.D., 125VDC 3A Contacts 25-025T-2HX 120VAC, 20-25-30 Hz, 0.5-20Sec. T.D., 125VDC 3A Contacts 25-100T-1HX 480VAC, 90-100-110 Hz, 0.5-20Sec. T.D., 125VDC 3A Contacts 20-040-1X 100VAC, 40-50 Hz 20-040-2X 120VAC, 40-50 Hz, 1.5-2.0 Sec. T.D. Protective Relays Additional Relays (Continued) 20-060-2PX 120VAC, Sim. to 20-060-2X w/ Suppression 20-060-4X 120VAC, 65-77 Hz 20-060-5X 120VAC, Jumper, Set at 60 Hz +3% or 50 Hz +3% 20-060-6X 120VAC, 103-156V Range, 60-70 Hz, Set at 70 Hz 20-060-7X 120VAC, 60-63Hz, 0.2 Sec T.D. on P.U., Suppression 20-060-8X 120VAC, 60-70 Hz, Spike Suppression 20-060-9X 120VAC, 60-70 Hz, 0.25 Sec. Inverse T.D. on P.U. 20-350X 120VAC, 350-500Hz 20-350SX 120VAC, 350-400Hz, 2 N.C. 2A Contacts, Hi-Shock 20-350-2SX 115VAC, 350-400Hz, Hi-Shock 20-350-4X 120VAC, 300-400 Hz 20-400X 120VAC, 400-450 Hz 20-400SX 120VAC, 400-450 Hz, High Shock 20-400-2SX 115VAC, Hi-Shock 20-400-3X 120VAC, 400-450 Hz, 2 N.C. Contacts 20-400-4X 120VAC, 400-500 Hz D20-040X D20-050X D20-050-2X D20-060X 11 ADJUSTABLE DIFFERENTIAL 120VAC, 40-50 Hz 120VAC, 50-60 Hz 120VAC, P.U. 50-60 Hz, D.O. 40-50 Hz 120VAC, 60-70 Hz VOLTAGE UNBALANCE RELAYS 1500X 1510X 1520X 1530X 1540X 1550X 120VAC, 3 Phase, 15% - 25% Adjustment 230VAC, 3 Phase, 15% - 25% Adjustment 380VAC, 3 Phase, 15% - 25% Adjustment 460VAC, 3 Phase, 15% - 25% Adjustment 575VAC, 3 Phase, 15% - 25% Adjustment 208VAC, 3 Phase, 15% - 25% Adjustment SUFFIX “-2”: N.C. Contacts (Example: 1500-2X) “-3”: 10% - 20% Adjustment “-4”: Transient Suppression “-H”: 125VDC 3A Contacts PAGE 43 Protective Relays 20-040-3X 120VAC, 40-50 Hz, 2 N.C. Contacts 20-040-4X 220VAC, 40-50 Hz. 20-050-HX 120VAC, 50-60 Hz, 125VDC 3A Contacts 20-050SX 120VAC, 50-60 Hz, High Shock, MIL-S-901C 20-050-1X 120VAC, 50-60 Hz, 0.2 Sec. T.D. 20-050-2X 120VAC, 45-66 Hz, U.L. 20-050-3X 120VAC, 50-60 Hz, 2000V PIV Diode 20-050-4X 120VAC, 50-60 Hz, 1 Sec. T.D., 0.5% Drift 20-050-8X 120VAC, 57-60 Hz, 0.2 Hz Diff., 240V Contacts, FAA 20-050-8PX 120VAC, Similar to 20-050-8X w/ Spike Suppression 20-050-9X 120VAC, 45-55 Hz 20-050-10X 120VAC, 50-60 Hz, Suppression 20-050-12X 120VAC, 50-60 Hz, 125VDC Contacts 20-050-13X 120VAC, 50-60 Hz, 2 Sec. T.D. 20-050-16X 150VAC, Similar to 20-050-10X except Voltage 20-050-19X 120VAC, Volt./Freq., 45-60 Hz, 85-120V 20-050-19PX 120VAC, Similar to 20-050-19X w/ Suppression 20-050-20X 120VAC, 50-60 Hz, 2 N.C. Contacts 20-050-21X 220VAC, 50-60 Hz 20-050-22X 120VAC, 50-60 Hz, 125VDC Contacts, Seismic 20-050-23X 240VAC, Similar to 20-050-19X except Voltage 20-050-23PX 240VAC, Similar to 20-050-23X w/Suppression 20-050-25X 104VAC, 50-60 Hz 20-050-26X 120VAC, 57-60 Hz, Supp., 0.2 Sec. T.D. on D.O. 20-050-27X 120VAC, Sim. to 20-050-26X, Operation Reversed 20-050-28X 120VAC, Sim. to 20-050-2X with Suppression 20-050-29X 120VAC, Sim. to 20-050-19X w/125VDC 2A Contacts 20-050-30X 120VAC, Sim. to 20-050-1X w/125VDC 2A Contacts 20-050-31X 200-480VAC, 50-60 Hz Range, 26VDC Control 20-050-32X 120VAC, Sim. to WUF-12-5060T, Operation Rev. 20-060-1X 120VAC, 60-70 Hz, 2000V Diode 20-060-2X 120VAC, 60-63 Hz, 0.2 Hz Diff., 240VAC Contacts Protective Relays Engineering Notes AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS
3-1618100-2 价格&库存

很抱歉,暂时无法提供与“3-1618100-2”相匹配的价格&库存,您可以联系我们找货

免费人工找货