KILOVAC High Voltage DC Contactors
KILOVAC EV200P Series Latching Contactor With 1 Form X (SPST Latch)
Contacts Rated 500+ Amps, 12-900 Vdc
Product Facts
Pick Up/Latch (Max) @ 25°C —
9 Vdc
Hold (Min) — N/A
Reset (Max)/Dropout (Min) —
9 Vdc
Duty Cycle, Max 7 — 20%
Coil Resistance @ 25°C — 2.5 Ω
Operate Specs @ 25°C —
Operate Time (Typ) — 15 ms
Operate Bounce (Max) — 7 ms
Release Time (Max) — 15 ms
n Latching
version of popular
EV200 Series
n Designed
to be the
smallest, lowest cost,
lightest weight sealed
contactor in the industry at
its current rating
n Optional
auxiliary contacts
for monitoring position of
power contacts
n Hermetically
sealed —
operates in explosive/
harsh environments with no
oxidation or contamination
of coil or contacts
during long periods of
non-operation
n Not
position sensitive,
can be mounted in any
orientation
n RoHS
versions available
Physical Data
Contact Arrangements —
Main Contacts — SPST, Latching
Auxiliary Contacts 1 — Up to 2 Form A
Dimensions — See drawing
Weight, Nominal — .95 lb. (.43 kg)
Environmental Data
Shock, 11ms 1/2 Sine
(Operating) — 30 Gpeak
Sine Vibration, 20 Gpeak —
55-2000 Hz
Random Vibration, 14.06 Grms —
15 Hz (.002 G2/Hz), 100 Hz (.002 G2/Hz),
450 Hz (.12 G2/Hz), 900 Hz (.12 G2/Hz),
2000 Hz (.083 G2/Hz)
Operating Temperature Range —
-40°C to +85°C
Electrical Data
Coil Data 5
Nominal Coil Voltage 6 — 12 Vdc
Ordering Information
Typical Part Number
EV200 P 4 A N A
Series:
EV200 = 500+ Amp, 12-900VDC Contactor
7
Contact Form:
P = Latching
F = Latching with 1 SPDT Aux.
Coil Voltage:
4 = 12 Vdc
5 = 24 Vdc
6 = 48 Vdc
KILOVAC High Voltage
DC Contactors
For factory-direct application assistance,
dial 800-253-4560, ext. 2055, or
805-220-2055.
Voltage Rating —
Main Contacts (Max) — 750 Vdc
Current Rating, Continuous —
Main Contacts 2 — 500A
Contact Resistance —
Main Contacts 3 —
0.2 mΩ max above 300A
0.3 mΩ max between 50 and 300A
Hot Switching Performance
(Positive Polarity) 4 —
200A make/ break @ 270Vdc —
10,000 cycles
600A make/ break @ 360Vdc —
100 cycles
800A break only @ 360Vdc —
15 cycles
2000A break only @ 360Vdc — 1 cycle
Mechanical Life (Min) —
75,000 cycles
Dielectric Withstand Voltage —
Terminal to Terminal/ Terminals to Coil
—
1mA max @ 2,200 Vrms
Insulation Resistance —
Terminal to Terminal/ Terminals to Coil
—
100MΩ min @ 500Vdc new
50MΩ min @ 500Vdc end of life
Notes:
1 Product can be configured alternately with form B or C auxiliary
switches if required. This changes
the product part number, depending on specific auxiliary configuration. Consult TE for availability and
part number
2 Ambient conditions and conductor
design affect rating. Terminal
temperature rise should be 75°C
max above ambient. Keep relay
terminals below 150°C max continuous, 175°C max for two hours,
and 200°C for 1 minute.
3 Stabilized reading. Contact resistance may exceed spec in the first
10 minutes of current carry.
4 Units are polarity sensitive.
Approximately 50% de-rating
for reverse polarity switching.
Consult factory for review of
specific requirements.
5 Over temperature range unless
noted. Suggested coil pulse =
50-100 ms.
6 24V and 48V coils available on
request — consult factory.
7 Intermittent Duty Coil. Coil overheating can occur if duty cycle
Coil Terminations:
A = 15.3 in. (300 mm)
Coil Termination Connector:
N = None
Mounting & Power Terminals:
A = Bottom Mount & Male 10mm x
M8 Threaded Terminals
PAGE 39
KILOVAC High Voltage DC Contactors
KILOVAC EV200P Series Latching Contactor (Continued)
Outline Dimensions
For factory-direct application assistance,
dial 800-253-4560, ext. 2055, or
805-220-2055.
AEROSPACE, DEFENSE & MARINE /// HIGH PERFORMANCE RELAYS
很抱歉,暂时无法提供与“3-1618394-1”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 20+3795.9586520+490.02646