HP Series
UL Recognized
ENEC Approved
ROHS Compliant
The HP series is the new power entry module developed for medical as well as general purpose applications
with EMI suppression up to 12 A. Three options are available within this series: General Purpose, HG option
with 1 MOPP(Means of Patient Protection) and NG option with 2 MOOP(Means of Operator Protection)
compliance with UL60601. A total of 96 variants are offered for a wide range of different applications, with
versatile features, and protection for medical patients & operators. The HP series is suitable for use in Class I
or Class II medical equipment (UL60601), such as Dental Lighting, Medical Imaging Equipment, Therapeutic
Equipment, Medical X-Ray Equipment, Medical Imaging Systems, Ultrasound Equipment etc. Corcom HP PEM
is designed using Eco-design principles, and its housing is made of post-consumer recycled material.
Features
Applications
High Protection Power Entry Module
Compatible with V-Lock plug
Compact / Light Weight
2 MOOP (double insulated, 3 kV) UL60601 -NG
1 MOPP (grounded, 5 µA leakage) UL60601 -HG
DPST Switch with rocker-guard option
Compact, flanged or Snap-In
Single- or Dual-Fusing
Shrouded FASTONs (for Class II protection)
General purpose
Medical devices
Instruments
Portable electrical/electronic devices
Laboratory equipment
Home appliances
Office equipment
Telecom devices
Electrical Schematics
Class I, 1 MOOP, General Purpose option
Class I, 1 MOPP, -HG
Class II, 2 MOOP, -NG
INDUSTRIAL/ HP SERIES EMI PEM FILTERS
Page 1
Electrical Specifications
Maximum leakage current per Line to Ground
@120V, 60Hz
@250V, 50 Hz
General Purpose
-HG, -NG
70 µA
140 µA
2 µA
5 µA
HIPOT rating (2 s)
L-G
Class I
L-G
Class II, (-NG)
Line to Line
2250 VAC
3000 VAC
1500 VDC
120/250 VAC
50/60 Hz
DPST, 10,000 operations at 51 A max. Inrush
2 X Rated for 8 second †
21 days, 40C @95% RH
-40C to 40C†
-40C to 85C
With IEC 60320 C14 or C18 socket
Rated Voltage
Operating Frequency
Switch
Current Overload
Humidity
Operating Ambient Temperature
Storage Temperature
Compatible with V-lock Plug
† Use 14 AWG power cord for current over 6 A. Limit fault current to 12 A at 40C.
Case Styles
HPE – Flange type
HPS – Snap-In type
Class II, IEC 60320 C18
Class I, IEC 60320 C14
6.3 x 0.8 mm output terminals comply with IEC61210.
Case Dimensions
Part #
HPE
HPS
A
52
34
B
60.5
60.5
INDUSTRIAL/ HP SERIES PEM EMI FILTERS
C
43.6
43.6
D
50.7
52.2
E
11.9
10.0
Page 2
Typical Insertion Loss
General purpose versions
Measured in closed 50-ohm system
3A
6A
db
db
70
60
50
40
30
20
10
0
70
60
50
40
30
20
10
0
0.01
0.1
1
COMMON MODE
10
0.01
100
10
100
DIFFERENTIAL MODE
12A
10A
db
70
70
60
60
50
50
40
40
30
30
20
20
10
10
0
0.1
1
COMMON MODE
10
100
0
0.01
DIFFERENTIAL MODE
Typical Insertion Loss
0.1
1
COMMON MODE
10
100
DIFFERENTIAL MODE
-NG and -HG versions
3A
6A
db
db
70
60
50
40
30
20
10
0
70
60
50
40
30
20
10
0
0.01
1
COMMON MODE
DIFFERENTIAL MODE
db
0.01
0.1
0.1
COMMON MODE
1
10
100
DIFFERENTIAL MODE
INDUSTRIAL/ HP SERIES PEM EMI FILTERS
0.01
0.1
COMMON MODE
1
10
100
DIFFERENTIAL MODE
Page 3
10A
12A
db
db
70
70
60
60
50
50
40
40
30
30
20
20
10
10
0
0
0.01
0.1
1
10
COMMON MODE
0.01
100
1
10
COMMON MODE
DIFFERENTIAL MODE
Minimum Insertion Loss
0.1
100
DIFFERENTIAL MODE
General purpose versions
INSERTION LOSS [dB]
COMMON MODE/ Asymmetrical (Line to Ground)
-__
3
6
10
DIFFERENTIAL MODE / Symmetrical (Line to Line)
12
3
6
10
12
MHz
TYP
MIN
TYP
MIN
TYP
MIN
TYP
MIN
TYP
MIN
TYP
MIN
TYP
MIN
TYP
0.05
9
3
0
0
0
0
0
0
14
8
13
7
14
8
14
MIN
8
0.15
18
12
3
0
1
0
1
0
23
17
23
17
23
17
23
17
0.3
24
18
7
1
3
0
3
0
29
23
29
23
29
23
29
23
0.5
29
23
12
6
6
0
6
0
33
27
34
28
34
28
34
28
1
34
24
17
7
10
0
10
0
37
27
39
29
40
30
40
30
3
45
35
26
16
19
9
19
9
38
28
47
37
56
46
56
46
5
53
43
30
20
24
14
24
14
44
34
47
37
56
46
56
46
10
49
34
36
21
30
15
30
15
60
45
59
44
35
20
35
20
30
30
15
37
22
33
18
33
18
50
35
49
34
47
32
47
32
Minimum Insertion Loss
-NG, -HG versions
INSERTION LOSS [dB]
-NG and
COMMON MODE/ Asymmetrical (Line to Ground)
-HG
MHz
3A
TYP
6A
10A
DIFFERENTIAL MODE / Symmetrical (Line to Line)
12A
3A
MIN
TYP
MIN
TYP
MIN
TYP
MIN
TYP
6A
MIN
TYP
10A
MIN
TYP
12A
MIN
TYP
MIN
0.05
9
3
0
0
0
0
0
0
14
8
14
8
14
8
14
8
0.15
18
12
3
0
1
0
1
0
23
17
23
17
23
17
23
17
0.3
24
18
7
1
3
0
3
0
29
23
29
23
29
23
29
23
0.5
28
22
11
5
6
0
6
0
33
27
34
28
34
28
34
28
1
31
21
14
4
9
0
9
0
38
28
40
30
40
30
40
30
3
34
24
18
8
12
2
12
2
41
31
48
38
53
43
53
43
5
33
23
18
8
12
2
12
2
41
31
50
40
60
50
60
50
10
30
15
16
1
10
0
10
0
40
25
51
36
51
36
51
36
30
24
9
14
0
9
0
9
0
39
24
46
31
43
28
43
28
INDUSTRIAL/ HP SERIES PEM EMI FILTERS
Page 4
Ordering Information (Part Description)
EXAMPLE:
12HPENS1
12 A **
FLANGED
NO SWITCH GUARD
SINGLE-FUSE
GENERAL PURPOSE
*Class II with insulated FASTONS.
** RATED 12 A UL/CSA, 10 A ENEC.
Available Part Numbers
Class I, 1 MOOP, General purpose
Part Description
Part Number
Snap-In, Guarded, Single Fuse
3HPSGS1
1-1609158-4
6HPSGS1
1-1609158-5
10HPSGS1
1-1609158-6
12HPSGS1
1-1609158-7
Flanges, Guarded, Single Fuse
3HPEGS1
2-1609158-2
6HPEGS1
2-1609158-3
10HPEGS1
2-1609158-4
12HPEGS1
2-1609158-5
Snap-In, Non-Guarded, Single Fuse
3HPSNS1
3-1609158-0
6HPSNS1
3-1609158-1
10HPSNS1
3-1609158-2
12HPSNS1
3-1609158-3
Flanges, Non-Guarded, Single Fuse
3HPENS1
3-1609158-8
6HPENS1
3-1609158-9
10HPENS1
4-1609158-0
12HPENS1
4-1609158-1
Weight, g
68
68
68
68
80
80
80
80
68
68
68
68
80
80
80
80
Part Description
Part Number
Snap-In, Guarded, Double Fuse
3HPSGD1
1-1609158-0
6HPSGD1
1-1609158-1
10HPSGD1
1-1609158-2
12HPSGD1
1-1609158-3
Flanges, Guarded, Double Fuse
3HPEGD1
1-1609158-8
6HPEGD1
1-1609158-9
10HPEGD1
2-1609158-0
12HPEGD1
2-1609158-1
Snap-In, Non-Guarded, Double Fuse
3HPSND1
2-1609158-6
6HPSND1
2-1609158-7
10HPSND1
2-1609158-8
12HPSND1
2-1609158-9
Flanges, Non-Guarded, Double Fuse
3HPEND1
3-1609158-4
6HPEND1
3-1609158-5
10HPEND1
3-1609158-6
12HPEND1
3-1609158-7
Weight, g
68
68
68
68
80
80
80
80
68
68
68
68
80
80
80
80
Continued …
INDUSTRIAL/ HP SERIES PEM EMI FILTERS
Page 5
HG, Class I, 1 MOPP
Part Description
Part Number
Snap-In, Guarded, Double Fuse
3HPSGD1-HG
7-1609158-4
6HPSGD1-HG
7-1609158-5
10HPSGD1-HG
7-1609158-6
12HPSGD1-HG
7-1609158-7
Flanges, Guarded, Double Fuse
3HPEGD1-HG
8-1609158-2
6HPEGD1-HG
8-1609158-3
10HPEGD1-HG
8-1609158-4
12HPEGD1-HG
8-1609158-5
Snap-In, Non-Guarded, Double Fuse
3HPSND1-HG
9-1609158-0
6HPSND1-HG
9-1609158-1
10HPSND1-HG
9-1609158-2
12HPSND1-HG
9-1609158-3
Flanges, Non-Guarded, Double Fuse
3HPEND1-HG
9-1609158-8
6HPEND1-HG
9-1609158-9
10HPEND1-HG
1-1609157-0
12HPEND1-HG
1-1609157-1
Weight, g
Weight, g
68
68
68
68
Part Description
Part Number
Snap-In, Guarded, Double Fuse
3HPSGD1-NG
4-1609158-2
6HPSGD1-NG
4-1609158-3
10HPSGD1-NG
4-1609158-4
12HPSGD1-NG
4-1609158-5
Flanges, Guarded, Single Fuse
3HPEGS1-NG
5-1609158-4
6HPEGS1-NG
5-1609158-5
10HPEGS1-NG
5-1609158-6
12HPEGS1-NG
5-1609158-7
80
80
80
80
Flanges, Guarded, Double Fuse
3HPEGD1-NG
5-1609158-0
6HPEGD1-NG
5-1609158-1
10HPEGD1-NG
5-1609158-2
12HPEGD1-NG
5-1609158-3
80
80
80
80
Snap-In, Non-Guarded, Single Fuse
3HPSNS1-NG
6-1609158-2
6HPSNS1-NG
6-1609158-3
10HPSNS1-NG
6-1609158-4
12HPSNS1-NG
6-1609158-5
68
68
68
68
Snap-In, Non-Guarded, Double Fuse
3HPSND1-NG
5-1609158-8
6HPSND1-NG
5-1609158-9
10HPSND1-NG
6-1609158-0
12HPSND1-NG
6-1609158-1
68
68
68
68
Flanges, Non-Guarded, Single Fuse
3HPENS1-NG
7-1609158-0
6HPENS1-NG
7-1609158-1
10HPENS1-NG
7-1609158-2
12HPENS1-NG
7-1609158-3
80
80
80
80
Flanges, Non-Guarded, Double Fuse
3HPEND1-NG
6-1609158-6
6HPEND1-NG
6-1609158-7
10HPEND1-NG
6-1609158-8
12HPEND1-NG
6-1609158-9
80
80
80
80
Part Description
Part Number
Snap-In, Guarded, Single Fuse
3HPSGS1-HG
7-1609158-8
6HPSGS1-HG
7-1609158-9
10HPSGS1-HG
8-1609158-0
12HPSGS1-HG
8-1609158-1
Flanges, Guarded, Single Fuse
3HPEGS1-HG
8-1609158-6
6HPEGS1-HG
8-1609158-7
10HPEGS1-HG
8-1609158-8
12HPEGS1-HG
8-1609158-9
Snap-In, Non-Guarded, Single Fuse
3HPSNS1-HG
9-1609158-4
6HPSNS1-HG
9-1609158-5
10HPSNS1-HG
9-1609158-6
12HPSNS1-HG
9-1609158-7
Flanges, Non-Guarded, Single Fuse
3HPENS1-HG
1-1609157-2
6HPENS1-HG
1-1609157-3
10HPENS1-HG
1-1609157-4
12HPENS1-HG
1-1609157-5
Weight, g
68
68
68
68
80
80
80
80
68
68
68
68
80
80
80
80
68
68
68
68
80
80
80
80
68
68
68
68
80
80
80
80
NG, Class II, 2 MOOP (Insulated FASTON)
Part Description
Part Number
Snap-In, Guarded, Single Fuse
3HPSGS1-NG
4-1609158-6
6HPSGS1-NG
4-1609158-7
10HPSGS1-NG
4-1609158-8
12HPSGS1-NG
4-1609158-9
Weight, g
68
68
68
68
te.com
Corcom, TE Connectivity, TE, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be
trademarks of their respective owners
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes
no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard
Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or
misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
© 2022 TE Connectivity. All Rights Reserved.
Version 07/2022
INDUSTRIAL/ HP SERIES PEM EMI FILTERS
Page 6