0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
5012W5812-0CS2458

5012W5812-0CS2458

  • 厂商:

    HUMIREL(泰科)

  • 封装:

    -

  • 描述:

    COAXCABLE-STANDARDP

  • 数据手册
  • 价格&库存
5012W5812-0CS2458 数据手册
5012W5812 SPECIFICATION CONTROL DRAWING CHEMINAX 50 OHM, AWG 12, 7 STRANDS OF AWG 20, WATERBLOCKED, OPTIMIZED SHIELD, TRIAXIAL CABLE Date 2-25-13 Revision R THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED. .0890 .239 .265 CONDUCTOR AWG 12, 7 Strands of AWG 20, Silver-Coated Copper DIELECTRIC Rayfoam L Color - Natural 1ST SHIELD AWG 34, Silver-Coated Copper Water Sealant filling shield interstices WATERBLOCK LAYER Non-Woven Polyester ELECTRICAL CHARACTERISTICS CHARACTERISTIC IMPEDANCE 50 ± 2 ohms, Method A CAPACITANCE 27.0 pF/ft. (nominal) 30.0 pF/ft. (maximum) VELOCITY OF PROPAGATION 78% (nominal) ATTENUATION (maximum) 0.7 dB/100 ft. at 10 MHz 2.3 dB/100 ft. at 100 MHz 5.4 dB/100 ft. at 400 MHz 9.2 dB/100 ft. at 1000 MHz SURFACE TRANSFER IMPEDANCE 700 milliohms/meter (maximum) at .1 MHz - 1 GHz EMP RESPONSE (2ND SHIELD) 60.0 dB (minimum) for 1 meter ADDITIONAL REQUIREMENTS ELECTRICAL CONDUCTOR RESISTANCE 1.9 ohms/1000 ft. (nominal) INSULATION RESISTANCE (DIELECTRIC) 10,000 megohms (minimum) for 1000 ft. JACKET FLAWS SPARK TEST IMPULSE TEST 1.0 kV (rms) 6.0 kV (peak) 1500 volts (rms) (minimum) 500 volts (rms) (minimum) .323 1ST JACKET Zerohal Color - Black VOLTAGE WITHSTAND (DIELECTRIC) CONDUCTOR TO SHIELD SHIELD TO SHIELD ENVIRONMENTAL .349 2ND SHIELD AWG 34, Silver-Coated Copper Optimized Water Sealant filling shield interstices WATERBLOCK LAYER Non-Woven Polyester .450 ± .010 2ND JACKET Zerohal Outer jacket color will be black (designated by a “-0" appended to the part number, e.g. 5012W5812-0) unless otherwise specified. Designate outer jacket color with a dash number in accordance with MIL-STD-681. Other codes and suffixes may be added to the part number, as necessary, to capture any additional requirements imposed by the purchase order. FLAMMABILITY Method B HEAT SHOCK 225°C LOW TEMPERATURE-COLD BEND -30°C/12.00 inch mandrel PHYSICAL INSULATION (DIELECTRIC) ELONGATION TENSILE STRENGTH 50% (minimum) 1000 lbf/in2 (minimum) 2ND JACKET ELONGATION TENSILE STRENGTH 150% (minimum) 1200 lbf/in2 (minimum) 1ST SHIELD COVERAGE 90% (minimum) 2ND JACKET THICKNESS .043 inch (nominal) WRAP (EACH) .006 inch thick (nominal) WEIGHT 147. lbs/1000 ft. (nominal) Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. Page 1 of 1 Rayfoam, Zerohal, Cheminax, Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue Redwood City, California 94063-3800 1-800-227-8816 Fax: 1-650-361-6297 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. © 2005- 2013 Tyco Electronics Corporation, All rights reserved.
5012W5812-0CS2458 价格&库存

很抱歉,暂时无法提供与“5012W5812-0CS2458”相匹配的价格&库存,您可以联系我们找货

免费人工找货