SPECIFICATION CONTROL DRAWING
55/0324
Date
TWO CONDUCTOR CABLE, UNSHIELDED, UNJACKETED,
01-28-04
OUTER SPACE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55/.
TITLE
Revision
E
COMPONENT WIRES - 55/0314
CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
55/0324-30-*
55/0324-28-*
55/0324-26-*
55/0324-24-*
55/0324-22-*
55/0324-20-*
CONDUCTOR
SIZE
(AWG)
30
28
26
24
22
20
OUTSIDE DIAMETER
(inches)
NOMINAL
.039
.047
.055
.064
.078
.099
MAXIMUM
WEIGHT
(lbs/1000 ft.)
MAXIMUM
.041
.050
.058
.067
.081
.102
1.04
1.62
2.39
3.58
5.40
8.57
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
INSULATION FLAWS:
Spark Test, 1.5 kV (rms) (30 - 24 awg)
3.0 kV (rms) (22 awg and larger)
Impulse Dielectric Test, 6.0 kV (peak)
PART NUMBER:
The "*" in the part numbers above shall be
replaced by color code designators with a
slash separating the component wire colors.
1/ Example: AWG 20, black and white component wires:
55/0324-20-0/9
NOTE: Nominal values are for information only.
Nominal values are not requirements.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to
1/COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
Page 1 of 1
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Telephone: 1-800-227-8816
Facsimile: 1-650-361-6297