55K9082
Issue 6
15th December 2009
Specification Control Drawing
Page 1 of 1
TWO CONDUCTOR CABLE, MODIFIED FLUOROPOLYMER INSULATED,
600 VOLT, 180°C, CONTROLLED WEIGHT
The complete requirements for procuring the wire described herein shall consist of this document and
Airbus Industrie Specification ABS0821 Issue 5
Component wire 55K9081
C6
C7
Part
Description
Wire
Size
55K9082-24-*/*
55K9082-22-*/*
55K9082-20-*/*
55K9082-18-*/*
24
22
20
18
C14
Resistance
@ 20°C
max.
ohms/km
117.42
61.80
34.20
21.73
C15
C13
Finished Cable
Outside Diameter mm
Lower
Upper
Spec
Target
Spec
Limit
Limit
1.94
2.04
2.14
2.23
2.33
2.43
2.70
2.80
2.90
3.20
3.30
3.40
C17
C16
Weight kg/km
Upper
Target
Spec
Limit
5.91
6.43
8.16
8.84
13.45
14.46
20.24
22.15
COLOUR CODE:
Cores - Red/Blue
PERFORMANCE
REQUIREMENTS:
To be tested to the issue in effect of WSD 840 and meet the requirements
of ABS0821 Issue 5.
MARKING:
Each core, every 300 ± 50mm horizontally along axis for sizes 18 & 20 and vertically
along axis for sizes 24 & 22. Marking shall be black.
Each mark shall be connected by a dashed line, each dash at 40-50mm, 5mm long,
0.5mm minimum width.
- - - PHXX U GBSYY - - - Where the XX is replaced by the wire size and the YY is
replaced by a year code designator in accordance with the table below.
e.g. - - - PH24 U GBS09 - - -
APPROVAL:
Electronic sign off - no signatures will appear.
©2009 Tyco Electronics Corporation. All International Rights Reserved.
很抱歉,暂时无法提供与“55K9082-24-2/6”相匹配的价格&库存,您可以联系我们找货