SPECIFICATION CONTROL DRAWING
55PC1111
Date
TITLE
ONE CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 600 VOLT
9-19-13
Revision
B
This specification sheet forms a part of the latest issue of Raychem Specification 55PC.
COMPONENT WIRE - 55PC0111
SHIELD - TIN-COATED COPPER
JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
SHIELD
SIZE
(AWG)
55PC1111-26-*
26
55PC1111-24-*
55PC1111-22-*
JACKET THICKNESS
(inch)
OUTSIDE DIAMETER
(inch)
WEIGHT
(lbs/1000 ft.)
LOWER
SPEC
LIMIT
TARGET
WALL
LOWER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
38
.0050
.0060
.056
.060
.064
4.00
4.24
24
38
.0050
.0060
.061
.065
.069
4.86
5.12
22
38
.0050
.0060
.068
.071
.074
6.13
6.41
55PC1111-20-*
20
38
.0050
.0060
.075
.079
.083
8.07
8.37
55PC1111-18-*
18
38
.0050
.0060
.085
.088
.092
10.82
11.22
55PC1111-16-*
16
38
.0050
.0060
.092
.096
.100
13.03
13.46
55PC1111-14-*
14
38
.0050
.0060
.107
.110
.114
18.34
18.85
55PC1111-12-*
12
38
.0050
.0065
.126
.130
.134
26.47
27.15
55PC1111-10-*
10
38
.0050
.0065
.151
.157
.162
39.82
41.05
55PC1111-8-*
8
38
.0060
.0075
.213
.220
.227
71.34
73.35
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”). OTHER CODES
AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks.
Page 1 of 2
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
© 2013 Tyco Electronics Corporation. All rights reserved.
Revision
Page
SPECIFICATION CONTROL DRAWING
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
JACKET FLAWS:
Spark Test, 1000 volts (rms)
Impulse Dielectric Test, 6.0 kV (peak)
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute
1/ PART NUMBER:
The "*" in the part numbers on page 1 shall be replaced by color code designators
with a dash separating the component wire color from the jacket color.
Example: AWG 22, white component wire; white jacket:
55PC1111-22-9-9
1/ See footer section on page 1
2 of 2
B
SCD
55PC1111
很抱歉,暂时无法提供与“55PC1111-20-9-9”相匹配的价格&库存,您可以联系我们找货