55PC6309-10-9-9-9CS2970 数据手册
TITLE
SPECIFICATION CONTROL DRAWING
Date
ONE CONDUCTOR CABLE, DOUBLE SHIELDED, DOUBLE JACKETED, GENERAL PURPOSE, 600 VOLT
55PC6309
2-13-13
Revision
B
This specification sheet forms a part of the latest issue of Raychem Specification 55PC.
COMPONENT WIRE - 55PC0213
JACKETS - RADIATION-CROSSLINKED,
MODIFIED ETFE
SHIELDS - NICKEL-COATED COPPER
CABLE CONSTRUCTION DETAILS
1st JACKET
THICKNESS ( in. )
LOWER
SPEC
LIMIT
TARGET
WALL
2nd
SHIELD
SIZE
(AWG)
38
.0050
.0060
38
.0050
.0060
18
38
.0050
55PC6309-16-*
16
38
55PC6309-14-*
14
38
55PC6309-12-*
12
55PC6309-10-*
10
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
1st
SHIELD
SIZE
(AWG)
55PC6309-22-*
22
55PC6309-20-*
20
55PC6309-18-*
2nd JACKET
THICKNESS ( in. )
OUTSIDE DIAMETER
( in. )
LOWER
SPEC
LIMIT
TARGET
WALL
LOWER
SPEC
LIMIT
TARGET
VALUE
38
.0050
.0060
.098
.104
38
.0050
.0065
.105
.113
.0060
38
.0050
.0065
.116
.123
.0050
.0060
38
.0050
.0065
.121
.0050
.0065
38
.0050
.0065
.137
38
.0050
.0065
38
.0055
.0070
38
.0050
.0065
38
.0055
.0070
UPPER
SPEC
LIMIT
WEIGHT
( lbs/1000 ft. )
TARGET
VALUE
UPPER
SPEC
LIMIT
.110
11.87
12.83
.121
14.48
15.59
.130
17.96
19.28
.130
.139
20.62
22.04
.146
.155
27.22
28.96
.156
.166
.176
36.68
38.79
.176
.190
.204
51.16
53.97
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES
AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
Page 1 of 2
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
© 2013 Tyco Electronics Corporation,. All rights reserved.
Revision
SPECIFICATION CONTROL DRAWING
Page 2 of 2
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
DIELECTRIC WITHSTAND:
1500 volts (rms), 60 Hz conductor to shield
500 volts (rms), 60 Hz shield to shield
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum) (each)
Tensile Strength, 5000 lbf/in² (minimum) (each)
JACKET FLAWS:
Spark Test, 1000 volts (rms)
Impulse Dielectric Test, 6.0 kV (peak)
SHIELD COVERAGE:
85% (minimum) (each)
VOLTAGE WITHSTAND (Post Environmental):
1000 volts (rms), 60 Hz, 1 minute
PART NUMBER:
The "*" in the part numbers on page 1 shall be replaced by color code designators
with a dash separating the component wire color from the inner jacket color and a
dash separating the inner jacket color from the outer jacket color.
1/ Example: AWG 22, white component wire; white inner jacket and white outer jacket:
55PC6309-22-9-9-9
1/ See footer section on page 1
B