0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6-1609128-4

6-1609128-4

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

    Power Line Filter

  • 数据手册
  • 价格&库存
6-1609128-4 数据手册
Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filters TE Connectivity (TE) offers over 300 solutions for RFI problems associated with susceptibility, as well as compliance with international emissions standards. TE Connectivity Corcom Products Engineering Offices USA 620 S. Butterfield Road Mundelein, IL 60060 Phone: 847-680-7400 Fax: 847-680-8169 6700 Fallbrook Ave. Suite 287 West Hills, CA 91307 Phone: 818-226-4306 Fax: 818-704-1757 IEC Inlet Filters and Power Entry Modules A complete line of power entry modules solves a variety of power entry needs by combining functions to reduce cost, space and labor. Germany Finsinger Feld 1 D-85521 Ottobrunn, Phone: 49-89-6089-0 Fax: 49-89-6089-767 People’s Republic of China DC Filters TE has developed a wide range of power line filters and power entry modules that combine several power management functions specifically designed for DC applications. Feedthrough Filters and Capacitors 668 Guiping Road Shanghai, 200233 Phone: 86-21-2407-1588 Fax: 86-21-2407-1599 For Sales assistance in the USA please refer to page 286 to find a Corcom product sales representative in your area. For Sales assistance in all other regions, please refer to page 289 to find the Product Information Center in your area. Designed to offer reliability and performance in high frequency applications and meet EN132200 and 132400 safety requirements. Available for AC or DC applications. Signal Line Products The SignalSentry filtered modular jack connector series combines different levels of filtering with RJ45 and RJ11 modular jacks to address signal line noise problems and crosstalk. Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Main Table of Contents Navigating the Catalog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1. RFI Power Line Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 RFI Power Line Filter Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 AQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 DK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 EBP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EDP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EOP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EMC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 EP & VP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 FC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 FL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 HQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 HT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 HZ Series NEW 4, 6, 10 and 20A versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 IK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 MV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Q Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 R Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 RK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 S Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68 SB Series NEW High Performance B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 SK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 U Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 V Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 W Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 WG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Y Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 2. Three Phase Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 Three Phase Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 A Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98 ADT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101 AYA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104 AYC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 AYO Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 BCF Series NEW Compact Three Phase Filters . . . . . . . . . . . . . . . . . . . . . . . . . .113 CFN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 FCD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118 3. Power Inlet Filters & Power Entry Modules . . . . . . . . . . . . . . . . . . . . . . .125 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126 Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128 Power Entry Module Selector Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129 C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 CU Series NEW Compact 1U Height Power Entry Module . . . . . . . . . . . . . . . .134 EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138 EC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 ED Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144 EEA & EEB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EAH & EBH Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 1 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Table of Contents (continued) EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EJM & EJMS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EJS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160 EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 GG & HG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166 H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172 L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175 LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180 M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183 P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192 SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201 SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203 4. DC Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210 Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211 DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212 DB Series NEW - Compact RFI High Current DC Inlet . . . . . . . . . . . . . . . . . . . .214 DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217 P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223 5. Feedthrough Filters and Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 Feedthrough Application Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226 FFA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228 FFD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231 AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234 DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237 6. Signal Line Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242 SignalSentry Filtered Modular Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243 SignalSentry Part Number Matrix / Ordering Information . . . . . . . . . . . . . . . . .244 SignalSentry Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245 L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247 L – Ganged Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 LC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249 LCT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252 Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253 Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255 L, LC, LCT and X Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .255 N and Z Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257 7. Technical Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262 Understanding RFI Power Line Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263 Understanding Hipot Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266 Understanding Leakage Current (Touch Current) . . . . . . . . . . . . . . . . . . . . . . . . .267 Understanding Insertion Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268 Appendix A - Conducted RFI Emissions Testing . . . . . . . . . . . . . . . . . . . . . . . . . .269 Appendix B - Conducted RFI Susceptibility Testing . . . . . . . . . . . . . . . . . . . . . . .270 Appendix C - Health Care Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270 Appendix D - Safety Agency File Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271 Part Number Index and Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273 North American Sales Representatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286 Authorized Corcom Product Distributors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288 Worldwide Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Inside Back Cover 2 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Navigating the Catalog Step 1: Determine the product family. The Corcom product guide contains seven sections with six distinct product families. Use the index numbers along the side of the catalog to quickly jump to that section. RFI Power Line Filters 1 Solutions associated with EMI/RFI susceptibility as well as compliance to international emissions standards for single phase power applications. Includes chassis and board mountable designs as well as single and two-stage filters. Three Phase Filters 2 Corcom Product Families Solutions associated with EMI/RFI susceptibility as well as compliance to international emissions standards for three phase and high current applications. IEC Inlet and Power Entry Modules 3 IEC inlet power filters and modular products that address a variety of power entry needs by combining several functions such as on/off switching, voltage selection switching, fuseholder, filtering in combination with the IEC inlet connector. DC Power Line Filters 4 EMI/RFI solutions for emissions and susceptibility specifically related to DC systems often found in central office and telecommunication applications. Feedthrough Filters and Capacitors 5 Products designed for through-bulkhead mounting for high frequency filtering. Designed to meet EN133200 and EN132400 safety requirements. Available in a variety of standard as well as custom configurations. Signal Line Products 6 Products that combine different levels of filtering with various sized RJ modular jacks. Signal line products are used to protect data transmissions as they pass through the RJ jacks or as they are transmitted on the PCB. Technical Notes 7 The appendices in the back of the catalog offer information such as safety agency classifications, general information regarding RFI, and testing procedures. (continued on next page ) Looking for Corcom EMI Facility Products? Power, data and signal line filters for shielded installations Available in Catalog 1654986 - see page 8 for more information 3 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Step 2: Use selector charts For Medical Application (continued) No Selector charts at the beginning of each section help you to narrow the selection. Attenuate Conducted RFI / EMI Yes For Hardened Equipment Applications Coming Out of Equipment Yes Try The No Coming Into Equipment Try The Follow the chart to locate one or several MV Series product series that could fit your specific 3-20A Page 54 application and requirements. HZ No Yes Yes Try The No Selector charts generally show filters in order of performance from good (at the top) to best performance (at the bottom). Series 1- 6A Page 92 RK Series 3-20A Page 65 Try The Try The B EBP, EDP,EOP SK Series 1-30A Page 15 Series 1-10A Page 21 Series 3-40A Page 75 EMC Try The Series 3-30A Page 24 EMC K SB Z S Series 3-30A Page 24 Series 1-60A Page 49 Series 6- 30A Page 71 Series 1-3A Page 92 Series 3-60A Page 68 FC DK K U V/W DK N EP / VP Series 1-20A Page 18 Series 6-10A Page 56 Series 3-20A Page 27 NEW B Series 1- 30A Page 15 NEW SB Series 6- 30A Page 71 Step 3: Open to the page referenced by the selector chart from X, Y or Z Class B 3-6A Page 37 All Series Are Listed in Ascending Performance Class A NEW HT Optimal filter selection requires testing in Series 6-15A Page 40 your specific system, as all systems have HQ unique characteristics. Series Series 3-6A Page 12 For EN550xxx (CISPR) For High Noise Industrial Application Series 3A Page 43 AQ For Switch Mode Power Supply Try The N ew 6 0 A Navigating the Catalog Series majority Series of questions Series Series Series Each product series contains three technical sections. The relating 1-20A 1-60A 6A 3-20A 6-50A Page 18 Page 49 Page 84 Page 86 Page 30 to product applications can be answered directly from these sections. Good Better WG Series 16A Page 89 New Terminations S Series 3-60A Page 68 New 60A to R V/W EDP - EOP G Q Technical Characteristics: This first section contains pictures, appropriate safety agency Series Series Series Series Series 1-20A 3-20A 1-10A 6-10A 3-20A classifications, a description of the series’ capabilities, applications, electrical Page 61 Page 86 Page 21 Page 35 Page 58 specifications, schematics, ordering information and available part FC T R EMC numbers. T to Best Series 3-20A Series 1-20A Series 3-30A Series 6-50A Series 3-20A 30 Page 80 61 Page 24of the Page Page 80 as and Page dimensions parts as well Drawings: The second section contains drawings the recommended cutouts. Dimensions are shown in inches with metric equivalents. Performance Data: The third section contains performance data in the form of typical insertion loss graphs and minimum insertion loss tables. If you already know the catalog number or series, the table of contents lists each series in the catalog within each section. The back of the catalog also has an index in alphanumeric order. The index will reference the technical section for that catalog number or series. The index also provides the unique TE ordering number for each part. Step 4: Contact your local Corcom product sales representative Corcom product sales representatives for North America as well as distributors and global contacts are listed in the back of the catalog. Contact the sales representative or office closest to you for technical assistance, stock and pricing. 4 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide e bl E C o ol cient ffi Relia Corcom EMI/RFI Filters and Energy Efficiency The efficiency of an electrical device is the ratio of the power it delivers to the power that it consumes. The difference is wasted as heat, and to prevent overheating of a device and the system in which it resides, this heat must be transferred out of the system and dissipated. The efficiency of every component, including the power entry module and selected filter, factors into the system’s overall efficiency. When the amount of heat is too great to dissipate through the system’s enclosure, forced air cooling becomes necessary. This is often accomplished with a fan, and the power used by that fan, (including its own thermal losses) further decreases the system efficiency by another 2% to 5%. Providing room for the fan and air passageways in the equipment increases its size and cost. Careful attention to the efficiency of every component in the system results in a simpler, smaller, lighter, cooler, more competitive product. Corcom EMI filters can help meet energy efficiency goals, including Energy Star rating and the new 80 Plus certification, which now recognizes systems that exceed 90% efficiency. By using the most energy efficient design and materials, Corcom filters can be the beginning of an energy efficient system strategy. Energy efficient power components don’t just lower energy bills and demand for power from the grid, they also increase product reliability. Small efficiency increases can decrease component temperatures throughout the system, and semiconductor life doubles for every 10°C decrease in temperature. Corcom filters are more efficient and run cooler, and this can help reduce system warranty costs, service calls and total support costs. Corcom filters • Have heat dissipation ratings as little as one third that of comparable filters. • Create less heat and run cooler • Improve system reliability • Are more efficient than PC board equivalents • Can help meet system power efficiency standards • Enable systems to be smaller and lighter • Save customers money by reducing energy costs 500 Heat Dissipation in mW/A 450 400 350 300 250 200 150 100 50 Other Power Entry Modules 0 Corcom CU Series 1A 3A 5 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Corcom Products Engineering Services and Custom Solutions Corcom Products Engineering Services and Custom Solutions TE Connectivity Corcom products were established as the world leader in EMI/RFI filtering technology with the introduction of the first line of catalog filter products over 50 years ago. Corcom Custom Filters Key Features: Today, TE continues to pursue the latest in EMI/RFI filter design by testing and evaluating application specific solutions for a wide range of industries. • Custom wire harness design In addition to our complete catalog of standard EMI/RFI filtering solutions, TE offers a full range of engineering services and custom products designed for unique applications. Corcom custom EMI/RFI product solutions can: • Custom filter options • Fully customizeable options including packaging • Agency approvals available as needed by customer • Time and cost savings to customer • Optimize both cost and performance to target a unique application • Simplify installation • Fit unique mechanical size, installation and/or connection requirements Termination and Wiring Customization Options: • Ensure conformance with EMI/RFI requirements of an entire system • Wire length • Apply EMI/RFI filtering in a specific frequency or range • Wire color • Wire gauge With design and testing facilities worldwide, TE is well suited to design an EMI/RFI solution that meets a wide range of unique application needs. • Molded connectors • Ring terminals • Custom terminations To discuss application specific filtering, contact the TE Corcom product sales representative or office closest to you. A complete list of sales representative and worldwide contacts is listed in the back of this catalog. 6 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Corcom Engineering Services and Custom Solutions EMI/RFI Testing Services Corcom Products Test Lab Key Features: An increase in electronic content and stringent regulatory compliance requirements have increased the need for time spent in qualifying test houses. At these “test labs,” products undergo a • We can test product number of qualifying tests which include conducted emissions, to the FCC / EN / EFT EFT, and harmonic content. Failure to comply with associated specifications standards can lead to delayed time-to-market and product • Let us know your testing needs and time redesign resulting in lost revenue and market share and an frame to ensure increase in time spent at the test lab. flexibility of testing and timely results Available Testing Standards: • Conducted EMI in accordance with FCC part 15 and 18 • EN55011, EN55022 and EN55014 • EFT (Electrically Fast Transient) in accordance with EN61000-4-4 TE Connectivity can help by heading off some of the potential pitfalls during testing and qualifying phases of new products. We offer complimentary testing to existing regulatory standards. We aim for a high standard of accuracy, and can help identify potential problems. We are not a certifying body and our test lab is not a qualified test lab; however, we test to the same standards and take product through the same rigor as any certifying lab. In addition, our engineers will recommend a solution and help with a design should a product fail to comply with conducted emissions, EFT and/or harmonic content standards. The advantage is clear: TE will provide you with a high degree of confidence that a product which passed our • Tests conducted up to 30A with insertion loss in-house testing will pass agency testing at a certifying test house measured up to 10GHz in reduced time and with reduced cost. • MIL-STD-461 CE101 & CE102 TE has three Corcom filter testing facilities: • Mundelein, IL, USA (main office and design center) • West Hills, CA, USA (regional office) • Ottobrunn, Germany (regional office and design center) 7 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Corcom EMI / RFI Product Solutions for Facility and Heavy Power Corcom EMI Facility Products Power, data and signal line filters for shielded installations TE Connectivity has dedicated more than 50 years to developing RFI filter technology for electronic devices. We're proud that our focus on the design and production of the highest quality products has made TE a world leader in RFI technology. Our leadership in the filter and power entry module markets was enhanced in 1988 with the aquisition of the Heavy Power Line Division of Cornell Dubilier. The high quality designs and manufacturing of these heavy power line filter products is maintained and enhanced by TE. We have continued that dedication to excellence begun by Cornell Dubilier and inherent to TE’s way of doing business. Only the highest quality designs, capacitors, inductors, and workmanship are used to produce these filters. We recognize the need for great care demanded by hi-rel military filters and automatically apply like quality to the heavy power line products. We treat all product as if it is high-reliability. The Mundelein, IL office provides application engineering service for these heavy power line and military products. Our engineers can help to design a special filter in the rare case a standard product from this catalog cannot adequately solve the problem. Additional product performance data and test results are available from the engineers at this facility. TE’s worldwide sales offices can help you locate information on these products or any of the hundreds of high quality power line filters, power entry modules and SignalSentry products made by TE. For more information on the complete line of EMI Facility products, request catalog number 1654986 or visit www.corcom.com 8 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 1. RFI Power Line Filters — Table of Contents RFI Power Line Filter Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 AQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 DK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 EBP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EDP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EOP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EMC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 EP & VP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 FC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 FL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 HQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 HT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 HZ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 IK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 MV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Q Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 R Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 RK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 S Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68 SB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 SK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 U Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 V Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 W Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 WG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Y Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 1 RFI Power Line Filters 9 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 10 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filter Selector Chart For Medical Application No Attenuate Conducted RFI / EMI Yes For Hardened Equipment Applications Coming Out of Equipment 1 Yes Try The No MV Series 3-20A Page 54 No For Switch Mode Power Supply HZ HT For EN550xxx (CISPR) For High Noise Industrial Application Series 3A Page 43 Yes Yes Class A Try The No Series 6-15A Page 40 X, Y or Z Class B Series 1- 6A Page 92 HQ Good to to Best B EBP, EDP,EOP SK Series 1-30A Page 15 Series 1-10A Page 21 Series 3-40A Page 75 SB B EMC Series 6- 30A Page 71 Series 1- 30A Page 15 Series 3-30A Page 24 EMC K Series 3-30A Page 24 Series 1-60A Page 49 Try The SB Z S Series 6- 30A Page 71 Series 1-3A Page 92 Series 3-60A Page 68 FC DK K U V/W Series 6-50A Page 30 Series 1-20A Page 18 Series 1-60A Page 49 Series 6A Page 84 Series 3-20A Page 86 DK N EP / VP Series 1-20A Page 18 Series 6-10A Page 56 Series 3-20A Page 27 S Better Try The Series 3-60A Page 68 WG Series 16A Page 89 New Terminations from Try The New 60A All Series Are Listed in Ascending Performance RK Series 3-20A Page 65 Try The NE W NEW NEW Series 3-6A Page 37 V/W EDP - EOP R Q G Series 3-20A Page 86 Series 1-10A Page 21 Series 1-20A Page 61 Series 3-20A Page 58 Series 6-10A Page 35 T R EMC FC T Series 3-20A Page 80 Series 1-20A Page 61 Series 3-30A Page 24 Series 6-50A Page 30 Series 3-20A Page 80 N ew 6 0 A Try The AQ Series 3-6A Page 12 RFI Power Line Filters Coming Into Equipment 11 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Frequency Power Line Filter or Power Entry Module AQ Series UL Recognized CSA Certified 3VAQ8F 6VAQ8F AQ Series Specifications • Low cost solution to power line noise at high frequencies • High common and differential mode performance from 10kHz to 1GHz • Available with an IEC inlet, fuseholder and switch • Suitable for applications where computers are used to process secret or confidential information Ordering Information Maximum leakage current each Line to Ground: 3A Models 6A Models 1.2 mA 2.3 mA .7 mA 1.2 mA @ 120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 V AQ 8 FS Suffix F – Fuseholder FS – Fuseholder & Switch (F & FS on VAQ8 only) Omit if none Input / Output Style 3 – Wire leads 8 – IEC inlet* (line side) Wire leads (load side) 2250 VDC 1450 VDC 3 or 6A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematics 3A Models LINE LOAD 6A Models AQ Series LINE LOAD Leakage current designation V – Standard Current Rating 3 or 6A Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Available Part Numbers 3VAQ3 3VAQ8F 3VAQ8FS 6VAQ3 6VAQ8F 6VAQ8FS *IEC 60320-1 C14 inlet mates with C13 connector 12 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Frequency Power Line Filter or Power Entry Module (continued) AQ Series Case Styles and Dimensions 3VAQ3 6VAQ3 2.46 62.3 .515 13.08 1 2.572 C L 65.3 12.0 Min. 304.8 .515 13.08 #6-32 1.0 ± 0.1 25.4 ± .25 #6-32 5.126 130.0 5.327±.015 135.3 12.0 Min. 304.8 (5 places) #6-32 (2 places) #6-32 Thd. .5 ± .01 12.7 ± .25 (2 x) 3.061 77.8 2.0 ± .01 50.8 ± .25 .78 19.8 .50 ± .02 12.7 ± .5 3VAQ8F 6VAQ8F 6.457 164 5.68 ± .01 44.3 ± .25 4.0 ± .01 102 ± .25 5.96 152.0 5.06 ± .015 128.6 ± .38 2.35 ± .015 59.6 ± .38 .90 22.9 1.58 ±.015 40 ± .38 12.0 Min. 305.0 .958 24.3 2.48 63.0 .355 ref 9.02 #6-32 (6) inserts .411 ref 10.4 2.328 ± .01 59 ± .35 1.125 ± .01 3.062 28.6 ± .25 77.8 #6-32 (6) inserts .354 ±.010 ref 8.99 ± .25 2.576 65.4 .375 ± .125 9.53 ± 3.2 .375 ± .125 9.53 ± 3.2 3VAQ8FS 6VAQ8FS 5.39 ± .015 136.9 ± .38 2.35 ± .015 59.6 ± .38 1.058 26.9 .172 4.37 #6-32 (6) inserts .44 11.2 1.575 ± .015 40.01 ± .38 .958 24.3 #6-32 (6) inserts .411 ref 10.4 1.62 41.2 12.0 Min. 305.0 6.30 160.0 .391 ± .01 9.93 ± .25 12.0 Min. 305.0 1.62 41.2 .375 ± .125 9.53 ± 3.2 RFI Power Line Filters 4.14 105.1 4.36 ± .015 111.4 ± .38 1.98 40.1 1.66 ± .015 42.1 ± .38 CL 2.48 63.0 7.125 181.0 6.347 ± .015 161.2 ± .38 4.0 ± .015 101.55 ± .25 2.33 ±.015 59.0 ± .38 .364 9.25 12.0 Min. 304.8 1.52 ± .01 3.07 38.5 ± .25 77.8 1.12 ± .01 28.3 ± .25 .391 ± .01 9.93 ± .25 2.58 65.4 .375 ± .125 9.53 ± 3.2 13 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Frequency Power Line Filter or Power Entry Module (continued) AQ Series Recommended Panel Cutouts .910 ± .005 23.11 ± .13 .855 ± .005 21.72 ± .13 .235 ± .005 R 5.969 ± .13 .620 ± .005 15.75 ± .13 1.295 ± .005 32.89 ± .13 .620 ± .005 Dia. 15.75 ± .13 Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3VAQ 6VAQ db db 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 0 100 1000 Frequency in MHz 0.01 0.1 1 10 100 1000 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground)      Differential Mode / Symmetrical (Line to Line)                                                            14 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Filters for High Impedance Loads at Low Current B Series UL Recognized CSA Certified VDE Approved 1 VB6 B Series RFI Power Line Filters VB1 / EB1 VB3 / EB3 Specifications • Small size & low cost Maximum leakage current each Line to Ground: • General purpose @ 120 VAC 60 Hz: @250 VAC 50 Hz: • Wide variety of termination options • Meets low leakage current requirements of VDE portable equipment and non-patient medical equipment Ordering Information VB Models EB Models .4 mA .7 mA .21 mA .36 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 10 E B 1 Input / Output Style 1 – .250 [6.3] spade terminals 3 – Wire leads 6 – Threaded bolt 1 to 30A Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C In an ambient temperature (Ta) higher than +40°C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 B Series Leakage current designation E – Low leakage (
6-1609128-4 价格&库存

很抱歉,暂时无法提供与“6-1609128-4”相匹配的价格&库存,您可以联系我们找货

免费人工找货