SPECIFICATION CONTROL DRAWING
TITLE
55PC0212
Date
WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, MEDIUM WEIGHT, GENERAL PURPOSE, 600 VOLT
8-6-13
Revision
D
This specification sheet forms a part of the latest issue of Raychem Specification 55PC.
INSULATION - RADIATION - CROSSLINKED,
MODIFIED ETFE
CONDUCTOR - SILVER-COATED COPPER
CONSTRUCTION DETAILS
PART
NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
55PC0212-26-*
26
55PC0212-24-*
24
55PC0212-22-*
55PC0212-20-*
CONDUCTOR DIAMETER
(in.)
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
LOWER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
19 x 38
.0175
.0183
.0191
19 x 36
.0225
.0233
.0241
22
19 x 34
.0285
.0293
.0301
20
19 x 32
.0365
.0375
.0385
9.19
55PC0212-18-*
18
19 x 30
.0452
.0464
.0476
55PC0212-16-*
16
19 x 29
.0514
.0527
.0538
55PC0212-14-*
14
19 x 27
.0644
.0659
55PC0212-12-*
12
37 x 28
.0825
.0845
DIAMETER
(in.)
WEIGHT
(lbs/1000 ft.)
LOWER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
38.4
.0328
.0345
.0362
1.38
1.52
24.3
.0378
.0395
.0412
1.98
2.13
15.1
.0438
.0455
.0472
2.90
3.06
.0523
.0540
.0557
4.38
4.57
5.79
.0616
.0635
.0654
6.59
6.90
4.52
.0690
.0710
.0730
8.37
8.70
.0674
2.88
.0838
.0860
.0882
12.88
13.33
.0865
1.90
.1020
.1047
.1074
19.73
20.30
1.19
55PC0212-10-*
10
37 x 26
.1050
.1070
.1090
.1252
.1290
.1328
31.12
32.13
55PC0212-8-*
8
133 x 29
.158
.163
.169
.658
.188
.196
.203
56.8
59.9
55PC0212-6-*
6
133 x 27
.198
.205
.212
.418
.233
.242
.251
89.7
94.7
55PC0212-4-*
4
133 x 25
.250
.260
.268
.264
.300
.311
.322
146.
154.
55PC0212-2-*
2
665 x 30
.320
.330
.340
.170
.370
.383
.397
227.
240.
55PC0212-1-*
1
817 x 30
.360
.370
.380
.139
.410
.424
.438
278.
291.
55PC0212-0-*
0
1045 x 30
.395
.415
.425
.108
.449
.466
.483
343.
366.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks.
Page 1 of 2
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
© 2013 Tyco Electronics Corporation,. All rights reserved.
Page
SPECIFICATION CONTROL DRAWING
Revision
2 of 2
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
COLOR: White preferred
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
INSULATION ELONGATION AND TENSILE STRENGTH:
Total Insulation,
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
INSULATION FLAWS:
Spark Test, 3.0 kV (rms)
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS: .008 in. (nominal) total insulation
SHRINKAGE: 230 ± 3°C for 1 hour, 0.125 inch (maximum) in 12 inches
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms)