Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
3-phase Delta External Power Line Filter for Frequency Converters
FCD Series
UL Recognized
6FCD10
FCD Series
Specifications
• Suitable to meet the latest EMC standards
• Insulated safety terminals
• Suitable for EMC troubleshooting in the field
• Very high attenuation
• High insertion loss
• BS models optimized for very high insertion loss
• BS models suitable for infeed/regenerative (ER)
applications
• Touch safe terminals provide easy connections
and prevent inadvertent contact for safety in the
most demanding applications
Ordering Information
150 FCD 10 BS -95
Terminal Block Option
-95 – 95mm terminal block
available on 150A only
omit for standard terminals
Filter Type
B – Single stage
BS – High performance
Single stage.
Omit for dual stage
Input / Output Style
10 – Terminal Block
Maximum leakage current
voltage drop to virtual N to PE/V:
6FCD10:
12 & 16FCD10:
25, 36 & 50FCD10:
12 & 16FCD10B:
25& 36FCD10B:
50FCD10B:
80 & 110FCD10B:
150FCD10B:
180 & 230FCD10B:
FCD10BS:
.26 mA/V
.45 mA/V
.52 mA/V
.46 mA/V
.52 mA/V
.57 mA/V
.62 mA/V
.63 mA/V
.92 mA/V
3.25 mA/V
Hipot rating (one minute):
Line to Ground:
Line to Line:
2250 VDC
1450 VDC
Rated Voltage (max):
Phase to Phase:
Phase to Neutral / Ground:
480 VAC
277 VAC
Operating Frequency:
50/60 Hz
Rated Current:
6 to 230A
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Electrical Schematics
6FCD10
Power line
Device
FCD Series
Current Rating
6, 12, 16, 25, 36, 50, 80, 110,
150, 180 or 230A
PE
PE
118
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
3-phase Delta External Filter for Frequency Converters
(continued)
FCD Series
Electrical Schematics (continued)
Available Part Numbers
12 to 50A FCD10
Power line
Device
L1
L1
L2
L2
L3
L3
PE
PE
Device
L1
L1
L2
L2
L3
L3
Slots: .260
6.61
D
PE
80 to 230A FCD10B
Power line
2
Case Styles
6 to 50A FCD10 & FCD10B
B
PE
12FCD10B
50FCD10BS
16FCD10B
80FCD10BS
25FCD10B
110FCD10BS
36FCD10B
150FCD10BS
50FCD10B
150FCD10BS-95
80FCD10B
180FCD10BS
110FCD10B
230FCD10BS
150FCD10B
150FCD10B-95
180FCD10B
230FCD10B
Three Phase Filters
12 to 50A FCD10B
Power line
6FCD10
12FCD10
16FCD10
25FCD10
36FCD10
50FCD10
F
E
Device
L1
L1
L2
L2
L3
L3
C
A
80 to 150A FCD10B
50 to 150A FCD10BS
PE
Slots: .260
6.61
PE
FCD10BS
Power line
B
Device
L1
L1
L2
L2
L3
L3
D
F
E
150FCD10B-95
Terminal Block
C
PE
PE
A
A (150FCD10B-95)
119
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
3-phase Delta External Filter for Frequency Converters
(continued)
FCD Series
Case Styles (continued)
180 to 230FCD10B\BS
Slots: .260
6.61
Case Dimensions
Part No.
Center slot on
180 & 230A only
D
E
F
25FCD10/10B
36FCD10/10B
50FCD10/10B
F
E
C
Terminals
Terminal
Size
Torque max.
lbf-in [N-m]
Ground
8-32
20.7 [2.34]
4mm²
7.08 [0.8]
6FCD10
Line/Load
terminal block
Ground
M5
26.58 [3.0]
Line/Load
4mm²
7.08 [0.8]
terminal block
M5
26.58 [3.0]
Line/Load
6mm²
15.93 [1.8]
Ground
Line/Load
Ground
50FCD10BS
Line/Load
Ground
80 to 150FCD10B
80 to 150FCD10BS Line/Load
150FCD10B/BS-95
Ground
180FCD10B/BS
Line/Load
230FCD10B/BS
80FCD10B/BS
110FCD10B/BS
150FCD10B/BS
terminal block
M5
10mm²
terminal block
M10
16mm²
terminal block
M10
180FCD10B/BS
230FCD10B/BS
Performance Data
Typical Insertion Loss
Ground
50FCD10/10B
50FCD10BS
150FCD10B-95
150FCD10BS-95
A
25FCD10/10B
36FCD10/10B
C
12FCD10/10B
16FCD10/10B
B D
12FCD10/10B
16FCD10/10B
B
6FCD10
Part No.
A
26.58 [3.0]
15.93 [1.8]
88.5 [10.0]
20.36 [2.3]
88.5 [10.0]
Measured in closed 50 Ohm system
6FCD10
12FCD10
db
100
db
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
50mm²
terminal block
70.80 [8.0]
M10
88.5 [10.0]
95mm²
177.0 [20.0]
terminal block
0
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
1
10
30
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
120
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
3-phase Delta External Filter for Frequency Converters
(continued)
FCD Series
Performance Data (continued)
Typical Insertion Loss
(continued)
Measured in closed 50 Ohm system
16FCD10
25FCD10
36FCD10
50FCD10
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
1
10
30
Frequency in MHz
0
2
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
16FCD10B
25FCD10B
36FCD10B
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0
0
0
0.01
0.1
1
10
30
Frequency in MHz
0.01
0.1
1
10
30
Frequency in MHz
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
80FCD10B
110FCD10B
150FCD10B
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
1
10
30
Frequency in MHz
0
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
230FCD10B
50/80/110FCD10BS
150FCD10BS
db
100
db
100
db
100
db
100
90
90
90
90
80
80
80
80
70
70
70
70
60
60
60
60
50
50
50
50
40
40
40
40
30
30
30
30
20
20
20
20
10
10
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
180FCD10BS
230FCD10BS
db
100
db
100
90
90
80
10
30
Frequency in MHz
0
1
10
30
Frequency in MHz
1
10
30
Frequency in MHz
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
80
70
70
60
60
50
50
40
40
30
30
20
20
10
0
1
10
30
Frequency in MHz
10
0.01
180FCD10B
0
1
10
0.01
50FCD10B
0
10
30
Frequency in MHz
Three Phase Filters
12FCD10B
1
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
10
0.01
0.1
1
10
30
Frequency in MHz
0
0.01
0.1
1
10
30
Frequency in MHz
121
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
3-phase Delta External Filter for Frequency Converters
(continued)
FCD Series
Performance Data (continued)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
122
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
很抱歉,暂时无法提供与“63AYA10”相匹配的价格&库存,您可以联系我们找货
免费人工找货