MicroFit
Small diameter, high shrink ratio,
heat-shrinkable tubing
MicroFit tubing is micro-sized, heatshrinkable tubing that offers a high shrink
ratio (up to 3:1) and fits a range of diameters
from .007” to .045”. It is offered in a variety of
materials including two medical-grade
formulations from our Altera line of medicalgrade, heat-shrinkable tubing products.
MicroFit tubing provides electrical insulation,
mechanical protection, and strain relief in the
smaller, more compact medical devices and
commercial electronics products
manufactured today. MicroFit tubing’s
high shrink ratio eases installation since
the tubing’s diameter is large enough to slide
easily over the micro-sized substrate.
Yet, upon heating, the same tubing
shrinks to fit tightly on a wide range of
substrate diameters.
MicroFit tubing is offered in three materials:
RW-175, MT1000, and MT2000. MT1000
and MT2000 meet the requirements of
U.S. Pharmacopeia (USP) Class VI.
RW-175 and MT1000 tubings utilize a tough
semirigid fluoropolymer. They are especially
suitable for applications requiring hightemperature performance, outstanding
resistance to abrasion and cut-through,
and excellent resistance to a variety of fluids.
RW-175 meets NASA requirements for
low-outgassing materials. MTI000 tubing may
be sterilized by radiation, ethylene oxide,
steam, and dry heat with no significant
change in physical properties.
MT2000 tubing is made from a tough,
modified polyolefin that offers flexibility,
lubricity, and good electrical insulation
performance. MT2000’s low shrink temperature
enables the tubing to shrink faster than other
materials with similar attributes, thereby
reducing the risk of damage to temperaturesensitive substrates. MT2000 tubing may
be sterilized by gamma radiation or
ethylene oxide with no significant change
in physical properties.
Temperature rating
RW-175, MT1000
Full recovery temperature:
Continuous operating temperature:
Recommended maximum temperature
for use as a primary insulator:
175°C
–55°C to 175°C
135°C
MT2000
Full recovery temperature:
Continuous operating temperature:
140°C
–40°C to 105°C
Specifications*
Type
RW-175
MT1000, MT2000
Raychem
RW-175 MicroFit SCD
Altera MicroFit SCD
Material
Master File Number
USP Class VI
MAF-444 (MT1000), MAF-727 (MT2000)
*When ordering, always specify latest issue.
Dimensions (millimeters/inches)
W1
W2
Expanded as supplied
Fully recovered after heating
D
Part number
MFT-**-No. 1-***
MFT-**-No. 2-***
MFT-**-No. 33-***
MFT-**-No. 65-***
Inside diameter
D (min.)
Expanded
as supplied
0.356 0.014
0.610 0.024
1.143 0.045
0.635 0.025
d (max.)
Recovered after
heating
0.178 0.007
0.305 0.012
0.432 0.017
0.254 0.010
Wall thickness
W1
As supplied
(nominal)
0.076 0.003
0.064 0.0025
0.064 0.0025
0.127 0.005
d
W2 (max.)
Recovered
after heating****
0.127 0.005
0.152 0.006
0.118 0.007
0.330 0.013
**Replace double asterisk with material number: RW-175, MT1000 or MT2000 ***Replace triple asterisk with color-code number. ****Wall thickness will be less if tubing recovery is restricted during shrinkage.
Ordering information
Colors
Size selection
Standard packaging
Ordering description
RW-175, MT1000
MT2000
Standard
Clear
Black, clear
Nonstandard
Black
White, red, yellow, blue, orange
Always order the largest size that will shrink snugly over the component being covered.
A variety of special order sizes may be made available upon request.
In 4-foot lengths (RW-175); on plastic spools, double-bagged (MT1000, MT2000)
Specify product name, material type, size, and color; for example, MFT-MT2000-No.1-0 (0=Black).
RW-175 MicroFit specification values
Physical
Electrical
Property
Dimensions
Tensile strength
Unit
mm (inches)
psi (MPa)
Requirement
See reverse
5000 (34.5) minimum
Ultimate elongation
percent
150 minimum
Secant modulus (expanded)
Heat shock
(4 hours at 300°C/572°F)
Low temperature flexibility
(4 hours at -55°C/-67°F)
psi (MPa)
1 x 105 (690) minimum
No dripping, flowing
or cracking
No cracking after wrapping
on mandrel
Dielectric strength
volts/mil (volts/mm)
800 (31,500) minimum
Unit
mm (inches)
psi (MPa)
Requirement
See reverse
Method of test
ASTM D 2671
ASTM D 2671
2” per minute
ASTM D 2671
2” per minute
ASTM D 2671
AMS-DTL-23053,
5/16” mandrel
ASTM D 2671
Procedure C
5/16” mandrel
ASTM D 2671
Altera MicroFit specification values
Physical
Electrical
Chemical
Property
Dimensions
Tensile strength
MT1000
MT2000
Ultimate elongation
MT1000
MT2000
Secant modulus (expanded)
MT1000
MT2000
Dielectric strength
MT1000
MT2000
Dielectric withstand
3000 V, 60 Hz
Heavy metals analysis
Cadmium
Mercury
Lead
Bismuth
Antimony
5000 (34.5) minimum
3000 (20.7) minimum
percent
150 minimum
200 minimum
psi (MPa)
Method of test
ASTM D 2671
ASTM D 2671
2” per minute
ASTM D 2671
2” per minute
ASTM D 2671
1.0 X 105 (690) minimum
5.0 X 104 (344) minimum
volts/mil (volts/mm)
ASTM D 2671
seconds
800 (31,500) minimum
1000 (39,360) minimum
60 minimum
ppm
1 maximum (total of all metals)
ASTM D 2671
USP XXII
Physiochemical
Tests - Plastics
(See note below)
Note: Sample preparation and extraction is per USP XXII. Metals analysis may be colorimetric as described in USP XXII or by equivalent quantitive analytical method.
Users should independently evaluate the suitability of the product for their application.
Tyco Electronics Corporation
300 Constitution Drive
Menlo Park, CA 94025-1164
USA
Tel: (800) 926-2425 (US & Canada)
Tel: +1 (650) 361-3860 (All other countries)
Faraday Road
Dorcan, Swindon, SN3 5HH
United Kingdom
Tel: +44 1793 528171
3816 Noborito, Tama-ku
Kawasaki, Kanagawa 214-8533
Japan
Tel: +81 44 900 5102
Asia Pacific Headquarters
26 Ang Mo Kio, Industrial Park 2
Singapore 569507
Tel: +65 4866 151
All information, including illustrations, is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Tyco Electronics Corporation makes
no warranties as to the accuracy or completeness of the information, and disclaims any liability regarding its use. Tyco Electronics Corporation’s only obligations are those in the Standard Terms and
Conditions of Sale for these products and in no case will Tyco Electronics Corporation be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of the
product. Tyco Electronics Corporation’s Specifications are subject to change without notice. In addition, Tyco Electronics Corporation reserves the right to make changes in materials or processing
without notification to the Buyer which do not affect compliance with any applicable specification.
For more information about this product visit www.tycoelectronics.com
© 1997, 2002 Tyco Electronics Corporation Printed in USA 1654059 6/02
Altera, Raychem, and MicroFit are trademarks of Tyco Electronics Corporation.