7724S0664
SPECIFICATION CONTROL DRAWING
77 OHM, AWG 24, 7 STRANDS OF .0076,
DATA BUS CABLE, OUTER SPACE USE
CHEMINAX
Date:
Revision:
8-8-18
D
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS
DIMENSIONS ARE NOMINAL VALUES IN INCHES, UNLESS
OTHERWISE DESIGNATED.
ELECTRICAL CHARACTERISTICS
CHARACTERISTIC IMPEDANCE
77 ± 7 ohms, Method C at 1 MHz
MUTUAL CAPACITANCE
30.0 pF/ft. (maximum)
ATTENUATION
2.0 dB/100 ft. (nominal) at 1 MHz
SURFACE TRANSFER IMPEDANCE 250 milliohms/meter (nominal) at 10 MHz
.0230
.047
± .002
.101
CONDUCTORS
AWG 24,
7 Strands of .0076,
Silver-Coated HighStrength Copper Alloy
DIELECTRICS
Radiation-Crosslinked,
Modified ETFE
Colors - Light Blue/White
SHIELD - Flat
.0015 Strand Thickness,
Silver-Coated Copper,
ADDITIONAL REQUIREMENTS
COMPONENT WIRE PRIOR TO CABLING
(Test procedures per SAE AS22759)
CONDUCTOR RESISTANCE
CROSSLINKING PROOF TEST
INSULATION (DIELECTRIC)
ELONGATION
TENSILE STRENGTH
INSULATION FLAWS
SPARK TEST
IMPULSE TEST
INSULATION RESISTANCE
LOW TEMPERATURE-COLD BEND
SHRINKAGE
28.2 ohms/1000 ft. (nominal)
300 ± 3°C for 1 hour, .500 inch mandrel,
.375 lb, 2.5 kV dielectric test
50% (minimum)
5000 lbf/in2 (minimum)
3.0 kV (rms)
8.0 kV (peak)
5000 megohms for 1000 ft. (minimum)
-65 ± 3°C for 4 hours, .500 inch mandrel,
1.00 lb, 2.5 kV dielectric test
200 ± 3°C for 1 hour,
.125 inch (maximum) in 12 inches
FINISHED CABLE
(Test procedures per NEMA WC 27500, unless otherwise specified)
.111
(nominal)
.116
(maximum)
JACKET
Radiation-Crosslinked,
Modified ETFE
BLOCKING
CABLE LAY LENGTH
CROSSLINKED VERIFICATION
FLAMMABILITY
(Method B of Spec 1200)
JACKET
ELONGATION
TENSILE STRENGTH
JACKET FLAWS
SPARK TEST
IMPULSE TEST
JACKET THICKNESS
LOW TEMPERATURE-COLD BEND
SHIELD COVERAGE
VOLTAGE WITHSTAND
(DIELECTRIC)
WEIGHT
200°C for 6 hours
.75 inch (minimum), 1.25 inches (maximum)
300 ± 5°C for 6 hours, 3.00 inch mandrel
3 seconds (maximum), 3 inches (maximum);
no flaming of facial tissue
50% (minimum)
5000 lbf/in2 (minimum)
1.0 kV (rms)
6.0 kV (peak)
.0045 (minimum), .0050 inch (nominal)
-55 ± 5°C for 4 hours, 3.00 inch mandrel
90% (minimum)
1000 volts (rms) (minimum)
8.0 lbs/1000 ft. (nominal)
OUTER SPACE REQUIREMENTS
RADIATION RESISTANCE
VACUUM STABILITY
Designate outer jacket color with a dash number in accordance
TOTAL MASS LOSS (TML)
with MIL-STD-681. Unless otherwise specified, outer jacket color
VOLATILE CONDENSABLE
will be white designated by a "-9" appended to the part number,
MATERIAL (VCM)
e.g. 7724S0664-9.
WEIGHT LOSS
Other codes and suffixes may be added to the part number, as
necessary, to capture any additional requirements imposed by
the purchase order.
500 megarads/3.25 inch mandrel
1.00% (maximum)
0.10% (maximum)
0.45% (maximum)
ENGINEERING REFERENCE
TEMPERATURE RATING
200°C (maximum)
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity also reserves the
right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Page 1 of 1
Cheminax, Raychem, TE Connectivity, and TE connectivity (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, California 94063-3800
Phone: 1-800-522-6752 Fax: 1-650-361-6297
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2006-2018 TE Connectivity Ltd. family of companies. All Rights Reserved.