7724S3664
SPECIFICATION CONTROL DRAWING
CHEMINAX
77 OHM, AWG 24, 19 STRANDS OF AWG 36, OPTIMIZED DOUBLE SHIELDS,
DATA BUS CABLE, MIL-STD-1553, OUTER SPACE USE
Date:
8-8-18
Revision:
E
THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200.
CONSTRUCTION DETAILS
DIMENSIONS ARE NOMINAL VALUES IN INCHES, UNLESS
OTHERWISE DESIGNATED.
.0250
.048
.032
CONDUCTORS
AWG 24,
19 Strands of AWG 36,
Silver-Coated HighStrength Copper Alloy
DIELECTRICS
Radiation-Crosslinked,
Modified ETFE
Colors - Light Blue/White
FILLERS
Radiation-Crosslinked,
Modified ETFE
.113
1st SHIELD - Optimized
AWG 38,
Silver-Coated Copper
.130
2nd SHIELD - Optimized
AWG 38,
Silver-Coated Copper
.146
JACKET
Radiation-Crosslinked,
Modified ETFE
ELECTRICAL CHARACTERISTICS
CHARACTERISTIC IMPEDANCE
77 ± 5 ohms, Method C at 1 MHz
MUTUAL CAPACITANCE
30.0 pF/ft. (maximum)
ATTENUATION
1.4 dB/100 ft. (maximum) at 1 MHz
SURFACE TRANSFER IMPEDANCE 10 milliohms/meter (maximum)
(Per SAE AS85485)
at 30 MHz
ADDITIONAL REQUIREMENTS
COMPONENT WIRE PRIOR TO CABLING
(Test procedures per SAE AS22759)
CONDUCTOR RESISTANCE
CROSSLINKING PROOF TEST
INSULATION (DIELECTRIC)
ELONGATION
TENSILE STRENGTH
INSULATION FLAWS
SPARK TEST
IMPULSE TEST
INSULATION RESISTANCE
LOW TEMPERATURE-COLD BEND
SHRINKAGE
26.5 ohms/1000 ft. (nominal)
300 ± 3°C for 1 hour, .500 inch mandrel,
.375 lb, 2.5 kV dielectric test
50% (minimum)
5000 lbf/in2 (minimum)
3.0 kV (rms)
8.0 kV (peak)
5000 megohms for 1000 ft. (minimum)
-65 ± 3°C for 4 hours, .750 inch mandrel,
1.00 lb, 2.5 kV dielectric test
200 ± 3°C for 1 hour,
.125 inch (maximum) in 12 inches
FINISHED CABLE
(Test procedures per NEMA WC 27500, unless otherwise specified)
BLOCKING
CABLE LAY LENGTH
CROSSLINKED VERIFICATION
FLAMMABILITY
(Method B of Spec 1200)
JACKET
ELONGATION
TENSILE STRENGTH
JACKET FLAWS
SPARK TEST
IMPULSE TEST
JACKET THICKNESS
LOW TEMPERATURE-COLD BEND
VOLTAGE WITHSTAND
(DIELECTRIC)
200°C for 6 hours
.75 inch (minimum), 1.25 inches (maximum)
300 ± 5°C for 6 hours, 6.00 inch mandrel
3 seconds (maximum), 3 inches (maximum);
no flaming of facial tissue
WEIGHT
21.7 lbs/1000 ft. (nominal)
50% (minimum)
5000 lbf/in2 (minimum)
1.0 kV (rms)
6.0 kV (peak)
.008 inch (nominal)
-55 ± 5°C for 4 hours, 6.00 inch mandrel
1000 volts (rms) (minimum)
OUTER SPACE REQUIREMENTS
RADIATION RESISTANCE
VACUUM STABILITY
Designate outer jacket color with a dash number in accordance
TOTAL MASS LOSS (TML)
with MIL-STD-681. Unless otherwise specified, outer jacket color
VOLATILE CONDENSABLE
will be white designated by a "-9" appended to the part number,
MATERIAL (VCM)
e.g. 7724S3664-9.
WEIGHT LOSS
Other codes and suffixes may be added to the part number, as
necessary, to capture any additional requirements imposed by
the purchase order.
500 megarads/4.25 inch mandrel
1.00% (maximum)
0.10% (maximum)
0.45% (maximum)
ENGINEERING REFERENCE
TEMPERATURE RATING
200°C (maximum)
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity also reserves the
right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Page 1 of 1
Cheminax, Raychem, TE Connectivity, and TE connectivity (logo) are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, California 94063-3800
Phone: 1-800-522-6752 Fax: 1-650-361-6297
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2006-2018 TE Connectivity Ltd. family of companies. All Rights Reserved.
很抱歉,暂时无法提供与“7724S3664-9”相匹配的价格&库存,您可以联系我们找货