0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
7724S3664-9

7724S3664-9

  • 厂商:

    HUMIREL(泰科)

  • 封装:

    -

  • 描述:

    COAXCABLE-DATABUS

  • 数据手册
  • 价格&库存
7724S3664-9 数据手册
7724S3664 SPECIFICATION CONTROL DRAWING CHEMINAX 77 OHM, AWG 24, 19 STRANDS OF AWG 36, OPTIMIZED DOUBLE SHIELDS, DATA BUS CABLE, MIL-STD-1553, OUTER SPACE USE Date: 8-8-18 Revision: E THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS DIMENSIONS ARE NOMINAL VALUES IN INCHES, UNLESS OTHERWISE DESIGNATED. .0250 .048 .032 CONDUCTORS AWG 24, 19 Strands of AWG 36, Silver-Coated HighStrength Copper Alloy DIELECTRICS Radiation-Crosslinked, Modified ETFE Colors - Light Blue/White FILLERS Radiation-Crosslinked, Modified ETFE .113 1st SHIELD - Optimized AWG 38, Silver-Coated Copper .130 2nd SHIELD - Optimized AWG 38, Silver-Coated Copper .146 JACKET Radiation-Crosslinked, Modified ETFE ELECTRICAL CHARACTERISTICS CHARACTERISTIC IMPEDANCE 77 ± 5 ohms, Method C at 1 MHz MUTUAL CAPACITANCE 30.0 pF/ft. (maximum) ATTENUATION 1.4 dB/100 ft. (maximum) at 1 MHz SURFACE TRANSFER IMPEDANCE 10 milliohms/meter (maximum) (Per SAE AS85485) at 30 MHz ADDITIONAL REQUIREMENTS COMPONENT WIRE PRIOR TO CABLING (Test procedures per SAE AS22759) CONDUCTOR RESISTANCE CROSSLINKING PROOF TEST INSULATION (DIELECTRIC) ELONGATION TENSILE STRENGTH INSULATION FLAWS SPARK TEST IMPULSE TEST INSULATION RESISTANCE LOW TEMPERATURE-COLD BEND SHRINKAGE 26.5 ohms/1000 ft. (nominal) 300 ± 3°C for 1 hour, .500 inch mandrel, .375 lb, 2.5 kV dielectric test 50% (minimum) 5000 lbf/in2 (minimum) 3.0 kV (rms) 8.0 kV (peak) 5000 megohms for 1000 ft. (minimum) -65 ± 3°C for 4 hours, .750 inch mandrel, 1.00 lb, 2.5 kV dielectric test 200 ± 3°C for 1 hour, .125 inch (maximum) in 12 inches FINISHED CABLE (Test procedures per NEMA WC 27500, unless otherwise specified) BLOCKING CABLE LAY LENGTH CROSSLINKED VERIFICATION FLAMMABILITY (Method B of Spec 1200) JACKET ELONGATION TENSILE STRENGTH JACKET FLAWS SPARK TEST IMPULSE TEST JACKET THICKNESS LOW TEMPERATURE-COLD BEND VOLTAGE WITHSTAND (DIELECTRIC) 200°C for 6 hours .75 inch (minimum), 1.25 inches (maximum) 300 ± 5°C for 6 hours, 6.00 inch mandrel 3 seconds (maximum), 3 inches (maximum); no flaming of facial tissue WEIGHT 21.7 lbs/1000 ft. (nominal) 50% (minimum) 5000 lbf/in2 (minimum) 1.0 kV (rms) 6.0 kV (peak) .008 inch (nominal) -55 ± 5°C for 4 hours, 6.00 inch mandrel 1000 volts (rms) (minimum) OUTER SPACE REQUIREMENTS RADIATION RESISTANCE VACUUM STABILITY Designate outer jacket color with a dash number in accordance TOTAL MASS LOSS (TML) with MIL-STD-681. Unless otherwise specified, outer jacket color VOLATILE CONDENSABLE will be white designated by a "-9" appended to the part number, MATERIAL (VCM) e.g. 7724S3664-9. WEIGHT LOSS Other codes and suffixes may be added to the part number, as necessary, to capture any additional requirements imposed by the purchase order. 500 megarads/4.25 inch mandrel 1.00% (maximum) 0.10% (maximum) 0.45% (maximum) ENGINEERING REFERENCE TEMPERATURE RATING 200°C (maximum) Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. Page 1 of 1 Cheminax, Raychem, TE Connectivity, and TE connectivity (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue Redwood City, California 94063-3800 Phone: 1-800-522-6752 Fax: 1-650-361-6297 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. © 2006-2018 TE Connectivity Ltd. family of companies. All Rights Reserved.
7724S3664-9 价格&库存

很抱歉,暂时无法提供与“7724S3664-9”相匹配的价格&库存,您可以联系我们找货

免费人工找货