7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
20
PART
NUMBER
RELEASED FOR PUBLICATION
REVISION
D
7-2151686-2
D
7- 2151686 -7
A
5
4
3
2
20
LOC
ALL RIGHTS RESERVED.
BY TYCO ELECTRONICS CORPORATION.
2151686 -2
6
DESCRIPTION
FEED TYPE
FINE CRIMP HEIGHT ADJUST
REVISIONS
DIST
A
ATLANTIC VERSION TERMINATOR
INTERFACE ADAPTER
1
66
P
LTR
PNEUMATIC
PNEUMATIC AND CRIMP
TOOLING KIT
DESCRIPTION
DATE
DWN
APVD
A
RELEASED
01OCT2012
BH
BH
B
ECR-16-000219
07JAN2016
JH
JDG
C
ECR-19-002583
18FEB2019
FZ
YY
D
ECR-19-009769
23JUN2019
TB
TE
PNEUMATIC
CRIMP TOOLING KIT
-
D
D
CRIMP
WIRE
INSUL
APPLICATOR DATA
SIZE
TYPE
F
O
3.30 mm [.130]
5.10 mm [.201]
APPLICATOR INSTRUCTIONS
408-35042
TE TERMINAL
TERMINAL DATA:
TE CRIMP SPECIFICATION
TAB 5.8X0.8
TERMINAL NAME:
WIRE STRIP LENGTH
5.20-5.80 mm [.205-.228 IN]
C
TERMINAL
APPLICATION
SPECIFICATION
TE TERMINAL
1-962846-1
n
114-18052
-
TERMINALS APPLIED
C1__DWG_PN_1_1
-
-
1
-
3
3.30-4.50 mm [.130-.177 IN]
-
1
-
INSULATION DIAMETER RANGE
-
1
-
1
-
1
-
1
-
1
C1__DWG_PN_2_0
C1__DWG_PN_2_1
TE TERMINAL
2-962846-1
C1__DWG_PN_3_0
C1__DWG_PN_3_1
1
-
TE TERMINAL
2-962846-2
1
-
C1__DWG_PN_4_0
1
-
C1__DWG_PN_4_1
2
-
1
-
1
-
WIRE
SIZE
4.00mm2
CRIMP HEIGHT
mm [INCH]
W1__DWG_WGAUGE_1
2.33+/-0.05 [.092+/-.002]
CRIMP HEIGHT
REFERENCE SETTING
W1__DWG_CRIMP_HT_1
8.7
1
-
4
1
-
1
-
W1__FA_SETTING_1
2
-
1
-
1
-
1
-
4
-
2
-
1
1
2
B
3
4
5
1
-
RECOMMENDED SPARE PARTS
1
-
REFER TO SUPPLIED INSTRUCTION SHEET FOR CLEANING, LUBRICATION AND
STORAGE OF APPLICATOR.
1
-
1
-
1
-
APPLY PART NUMBER 2-23419-6 LOCTITE TO THREADS OF ITEM 242.
2
-
CRIMP HEIGHT REFERENCE SETTING WAS THE SETTING USED WHEN THE
APPLICATOR WAS QUALIFIED AT THE FACTORY. ADJUSTMENT MAY BE
NECESSARY WHEN RUNNING APPLICATOR IN THE FIELD.
2
-
1
-
1
-
TERMINAL PITCH NOT COMPATIBLE WITH MECHANICAL FEED.
1
-
1
-
6. UNLESS SPECIFIED OTHERWISE TORQUE VALUES SHALL BE USED PER
DOCUMENT, 101-35000.
1
-
1
-
1
-
1
1
-
1
1
-
1
1
*WARNING
ON INSTALLATION, SET WIRE DISC TO CRIMP HEIGHT REFERENCE SETTING
FOR LARGEST WIRE SIZE. CRIMP HEIGHT REFERENCE SETTINGS GREATER
THAN THE VALUE SHOWN MAY CAUSE DAMAGE TO THE CRIMP TOOLING,
REFER TO THE INSTRUCTION SHEET FOR PROPER SETUP AND ADJUSTMENTS.
1
1
-
1
1
2
-
-
-
-
-
1
1
1
1
1
1
2
-
A
2119641-1
2119082-9
2079764-1
2119083-1
7-18023-7
2844940-1
994970-2
1-18028-2
2844908-1
2844907-1
2-455888-9
2079383-4
1803096-1
1803607-3
2119791-5
2119943-1
2119740-1
2168078-1
2168083-2
5-18022-5
1338683-8
2168083-3
1-2168083-0
1803382-2
18023-9
1803583-9
1803515-2
1803602-2
1-1752356-5
2079383-5
2-2844962-3
2844992-2
1-455888-0
1320928-6
2168083-2
1-18028-2
2119533-1
455888-2
2119806-1
3-22280-3
1-356885-4
2119805-1
454276-5
1633925-2
1-2119757-3
4-238011-6
3-1633965-9
455888-5
456410-4
1
1
1
1
1
1
REF REF
-
5
TE TERMINAL
1-962846-2
C1__DWG_PN_1_0
-
1
2
1
1
1
1
2
1
1
1
1
1
2
1
1
1
4
2
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-77 -72 -2
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
DIMENSIONS:
ATLANTIC VERSION
Shown on sheets 1 of 4
& 2 of 4
(Pacific version shown on sheets 3 of 4
AMP 4805 REV 31MAR2000
mm
& 4 of 4)
MATERIAL
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
PART NO
DWN
16JUL2012
CHK
16JUL2012
APVD
16JUL2012
L.ZHANG
L.ZHANG
S.XI
WEIGHT
NAME
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 3
1
2079764
1
2119083
1
7-18023-7
1
2844940-1
1
COUNTER_994970
1
1-18028-2
1
2844908
1
2844907
1
2-455888-9
2
2079383-4
1
1803096-1
1
1803607_3
1
2119791-5
1
2119943-1
1
2119740-1
2
2168078-1
1
2168083-2
1
5-18022-5
1
1338683-8
4
2168083-3
2
1-2168083-0
1
1803382-2
1
18023-9
1
1803583-9
1
1803515-2
1
1803602-2
1
1-1752356-5
2
2079383-5
2
2-2844962-3
1
2844992-2
1
1-455888-0
1
1320928-6
1
2168083-2
1
1-18028-2
1
2119533
1
455888-2
1
2119806
1
SIMP_3-22280-3
1
1-356885-4
1
2119805-1
1
454276-5
1
1633925-2
..
1
ITEM_7
..
1
ITEM_6
1
1-2119757-3
1
4-238011-6
1
3-1633965-9
1
455888-5
1
456410-4
248
244
243
242
241
238
164
119
99
98
82
79
78
71
70
69
67
66
60
59
56
54
53
50
49
46
44
41
34
33
30
29
28
24
21
20
19
18
13
12
11
10
9
8
7
6
5
4
3
2
1
ITEM
NO
Harrisburg, PA 17105-3608
-
-
1
2119082-9
TE Connectivity
APPLICATION SPEC
-
1
2119641-1
DESCRIPTION
PRODUCT SPEC
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
FEED CAM, AIR FEED
CAM, SNAIL, INSULATION ADJUSTMENT
WASHER, WAVE SPRING, CREST-TO-CREST
RETAINER, INSULATION DIAL
SCR, SKT HD CAP M3 X 4.0
AIR FEED MODULE
COUNTER, MAGNETIC
WASHER, FLAT, REG M4
SCREW, LOCKING
POST, LOCKING
SPACER, CRIMPER
SCR, BHSC, RoHS (M4 X 8)
EXTENSION PLATE
DOCUMENTATION PACKAGE
DEPRESSOR, WIRE
WASHER, SPACER
TAG,IDENTIFICATION
SCREW, DRIVE, RH, RoHS, 2 x .188
SCR, SKT HD CAP, RoHS, M4 X 8.0
SCR, HEX HD CAP, M4 X 6.0
FEED PAWL
SCR, SKT HD CAP, RoHS, M4 X 12.0
SCR, SKT HD CAP, RoHS, M4 X 10
HOLD DOWN, SPRING LOADED
SCR, SKT HD CAP M4 X 6.0
APPLICATOR BASIC ASSEMBLY, SF
RAM ASSEMBLY, SF ATLANTIC
SCR, BHSC, RoHS (M8 X 40)
SUPPORT, TERMINAL
SCR, BHSC, RoHS (M4 X 20)
SPACER, CYLINDRICAL, STRIP GUIDE
ASSEMBLY, STRIP GUIDE
SPACER, CRIMPER
STRIP GUIDE
SCR, SKT HD CAP, RoHS, M4 X 8.0
WASHER, FLAT, REG M4
STRIPPER, SIDE FEED
SPACER, CRIMPER
INSERT, SHEAR
SPRING, COMPRESSION
STOP, SHEAR
SHEAR HOLDER, FRONT
FLOATING SHEAR, FRONT
ANVIL, COMBINATION
DEPRESSOR, SHEAR
BLOCK, CRIMPER SPACER
CRIMPER, INSULATION O PREMIUM
SPACER, CRIMPER
CRIMPER, WIRE PREMIUM
Ocean Side Feed
Applicator
-
DRAWING NO
2151686
SCALE
1:2
RESTRICTED TO
SHEET
1
OF
-
4
& 4 ARE NOT REQUIRED FOR ATLANTIC VERSION
REV
D
C
B
A
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
20
RELEASED FOR PUBLICATION
BY TYCO ELECTRONICS CORPORATION.
6
5
4
3
2
20
LOC
A
ALL RIGHTS RESERVED.
1
REVISIONS
DIST
66
P
LTR
DESCRIPTION
DATE
SEE SHEET 1
-
DWN
APVD
-
-
-
D
D
FEED TYPE
PNEUMATIC
44
2
244
243
A
238
242
53
50
82
59
C
2
6.7
3
REF
8
1
1
18
70
69
2
3
SEE DETAIL A
0.5
34 REF
C
1
4
28
56
TERMINAL SUPPORT LOCATION
5
41
FEED SPRING SETTING POSITION
(SHOWN FROM REAR SIDE)
44
43.29
DETAIL A
164
33
0.05
66
2
67
24
A
30
B
RAM SET-UP
19
B
20
79
21
78
9
1
12
29
ITEM 30 LOCATED AT
FRONT HOLES
241
13
CAM POSITION
30mm STROKE
REF
30 REF
29 REF
1
11
119
46
98
99
34
54
8
1
60
54
10
1
FEED TRACK POSITION
GUIDE BY
INSULATION BARREL
248
A
A
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
49
40mm STROKE
AIR FEED
AMP 4805 REV 31MAR2000
DIMENSIONS:
ATLANTIC VERSION
Shown on sheets 1 of 4
& 2 of 4
(Pacific version shown on sheets 3 of 4
mm
& 4 of 4)
MATERIAL
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
16JUL2012
CHK
16JUL2012
APVD
16JUL2012
L.ZHANG
L.ZHANG
S.XI
TE Connectivity
Harrisburg, PA 17105-3608
NAME
PRODUCT SPEC
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
DWN
-
APPLICATION SPEC
-
-
WEIGHT
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 3
Ocean Side Feed
Applicator
-
DRAWING NO
2151686
SCALE
1:2
RESTRICTED TO
SHEET
2
OF
& 4 ARE NOT REQUIRED FOR ATLANTIC VERSION
-
4
REV
D
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
20
RELEASED FOR PUBLICATION
6
REVISION
DESCRIPTION
FEED TYPE
2- 2151686 -2
D
FINE CRIMP HEIGHT ADJUST
PNEUMATIC
A
3
2
LOC
PART
NUMBER
7- 2151686 -7
4
20
ALL RIGHTS RESERVED.
BY TYCO ELECTRONICS CORPORATION.
5
CRIMP TOOLING KIT
REVISIONS
DIST
A
PACIFIC VERSION TERMINATOR
INTERFACE ADAPTER
1
66
P
LTR
-
DESCRIPTION
DATE
SEE SHEET 1
DWN
APVD
-
-
-
-
D
D
CRIMP
WIRE
INSUL
APPLICATOR DATA
SIZE
TYPE
F
O
3.30 mm [.130]
5.10 mm [.201]
APPLICATOR INSTRUCTIONS
408-35042
TE TERMINAL
TERMINAL DATA:
TE CRIMP SPECIFICATION
TAB 5.8X0.8
TERMINAL NAME:
WIRE STRIP LENGTH
5.20-5.80 mm [.205-.228 IN]
C
TERMINAL
APPLICATION
SPECIFICATION
1-962846-1
114-18052
-
TERMINALS APPLIED
TE TERMINAL
n
1-962846-2
C1__DWG_PN_1_1
-
3
INSULATION DIAMETER RANGE
-
3.30-4.50 mm [.130-.177 IN]
-
-
-
-
-
-
-
5
TE TERMINAL
C1__DWG_PN_1_0
-
C1__DWG_PN_2_0
TE TERMINAL
C1__DWG_PN_2_1
2-962846-1
C1__DWG_PN_3_0
C1__DWG_PN_3_1
TE TERMINAL
-
C1__DWG_PN_4_0
2-962846-2
-
C1__DWG_PN_4_1
-
WIRE
SIZE
4.00mm2
CRIMP HEIGHT
mm [INCH]
W1__DWG_WGAUGE_1
2.33+/-0.05 [.092+/-.002]
CRIMP HEIGHT
REFERENCE SETTING
W1__DWG_CRIMP_HT_1
8.7
-
4
-
W1__FA_SETTING_1
B
1
2
RECOMMENDED SPARE PARTS
-
REFER TO SUPPLIED INSTRUCTION SHEET FOR CLEANING, LUBRICATION AND
STORAGE OF APPLICATOR.
3
APPLY PART NUMBER 2-23419-6 LOCTITE TO THREADS OF ITEM 242.
4
CRIMP HEIGHT REFERENCE SETTING WAS THE SETTING USED WHEN THE
APPLICATOR WAS QUALIFIED AT THE FACTORY. ADJUSTMENT MAY BE
NECESSARY WHEN RUNNING APPLICATOR IN THE FIELD.
5
-
-
TERMINAL PITCH NOT COMPATIBLE WITH MECHANICAL FEED.
-
1
6. UNLESS SPECIFIED OTHERWISE TORQUE VALUES SHALL BE USED PER
DOCUMENT, 101-35000.
-
1
-
1
1
1
*WARNING
ON INSTALLATION, SET WIRE DISC TO CRIMP HEIGHT REFERENCE SETTING
FOR LARGEST WIRE SIZE. CRIMP HEIGHT REFERENCE SETTINGS GREATER
THAN THE VALUE SHOWN MAY CAUSE DAMAGE TO THE CRIMP TOOLING,
REFER TO THE INSTRUCTION SHEET FOR PROPER SETUP AND ADJUSTMENTS.
-
1
1
1
1
-
A
2119082-9
2079764-1
2119083-1
7-18023-7
2844940-1
994970-2
2119641-2
2168083-8
2168083-9
1-1803583-0
1803516-2
1-18028-2
2844908-1
2844907-1
2-455888-9
2079383-4
1803096-1
1803607-3
2119791-5
2119943-1
2119740-1
2168078-1
5-18022-5
1338683-8
1-2168083-0
1803382-2
18023-9
1803602-2
1-1752356-5
2079383-5
2-2844962-3
2844992-2
1-455888-0
1320928-6
2168083-2
1-18028-2
2119533-1
455888-2
2119806-1
3-22280-3
1-356885-4
2119805-1
454276-5
1633925-2
1-2119757-3
4-238011-6
3-1633965-9
455888-5
456410-4
1
1
1
1
1
REF
1
1
4
1
1
1
1
1
1
2
1
1
1
1
1
2
1
1
2
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PART NO
-77 -22
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
DIMENSIONS:
PACIFIC VERSION
Shown on sheets 3 of 4
& 4 of 4
(Atlantic version shown on sheets 1 of 4
AMP 4805 REV 31MAR2000
mm
& 2 of 4)
MATERIAL
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
DWN
16JUL2012
CHK
16JUL2012
APVD
16JUL2012
L.ZHANG
L.ZHANG
S.XI
WEIGHT
NAME
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 1
1
2119083
1
7-18023-7
1
2844940-1
1
COUNTER_994970
1
2119641-2
1
2168083-8
4
2168083-9
1
1-1803583-0
1
1803516-2
1
1-18028-2
1
2844908
1
2844907
1
2-455888-9
2
2079383-4
1
1803096-1
1
1803607_3
1
2119791-5
1
2119943-1
1
2119740-1
2
2168078-1
1
5-18022-5
1
1338683-8
2
1-2168083-0
1
1803382-2
2
18023-9
1
1803602-2
1
1-1752356-5
2
2079383-5
2
2-2844962-3
1
2844992-2
1
1-455888-0
1
1320928-6
1
2168083-2
1
1-18028-2
1
2119533
1
455888-2
1
2119806
1
SIMP_3-22280-3
1
1-356885-4
1
2119805-1
1
454276-5
1
1633925-2
..
1
ITEM_7
..
1
ITEM_6
1
1-2119757-3
1
4-238011-6
1
3-1633965-9
1
455888-5
1
456410-4
244
243
242
241
238
164
151
144
143
141
140
119
99
98
82
79
78
71
70
69
67
66
59
56
53
50
49
41
34
33
30
29
28
24
21
20
19
18
13
12
11
10
9
8
7
6
5
4
3
2
1
ITEM
NO
Harrisburg, PA 17105-3608
-
-
1
2079764
TE Connectivity
APPLICATION SPEC
-
1
2119082-9
DESCRIPTION
PRODUCT SPEC
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
CAM, SNAIL, INSULATION ADJUSTMENT
WASHER, WAVE SPRING, CREST-TO-CREST
RETAINER, INSULATION DIAL
SCR, SKT HD CAP M3 X 4.0
AIR FEED MODULE
COUNTER, MAGNETIC
FEED CAM, AIR FEED
SCR, SKT HD CAP, RoHS, M4 X 16
SCR, SKT HD CAP, RoHS, M4 X 20
APPLICATOR BASIC ASSEMBLY, SF
RAM ASSEMBLY, SF PACIFIC
WASHER, FLAT, REG M4
SCREW, LOCKING
POST, LOCKING
SPACER, CRIMPER
SCR, BHSC, RoHS (M4 X 8)
EXTENSION PLATE
DOCUMENTATION PACKAGE
DEPRESSOR, WIRE
WASHER, SPACER
TAG,IDENTIFICATION
SCREW, DRIVE, RH, RoHS, 2 x .188
SCR, HEX HD CAP, M4 X 6.0
FEED PAWL
SCR, SKT HD CAP, RoHS, M4 X 10
HOLD DOWN, SPRING LOADED
SCR, SKT HD CAP M4 X 6.0
SCR, BHSC, RoHS (M8 X 40)
SUPPORT, TERMINAL
SCR, BHSC, RoHS (M4 X 20)
SPACER, CYLINDRICAL, STRIP GUIDE
ASSEMBLY, STRIP GUIDE
SPACER, CRIMPER
STRIP GUIDE
SCR, SKT HD CAP, RoHS, M4 X 8.0
WASHER, FLAT, REG M4
STRIPPER, SIDE FEED
SPACER, CRIMPER
INSERT, SHEAR
SPRING, COMPRESSION
STOP, SHEAR
SHEAR HOLDER, FRONT
FLOATING SHEAR, FRONT
ANVIL, COMBINATION
DEPRESSOR, SHEAR
BLOCK, CRIMPER SPACER
CRIMPER, INSULATION O PREMIUM
SPACER, CRIMPER
CRIMPER, WIRE PREMIUM
Ocean Side Feed
Applicator
-
DRAWING NO
2151686
SCALE
1:2
RESTRICTED TO
SHEET
3
OF
-
4
& 2 ARE NOT REQUIRED FOR PACIFIC VERSION
REV
D
C
B
A
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
20
RELEASED FOR PUBLICATION
6
5
4
3
2
20
LOC
A
ALL RIGHTS RESERVED.
BY TYCO ELECTRONICS CORPORATION.
1
REVISIONS
DIST
66
P
LTR
DESCRIPTION
DATE
SEE SHEET 1
-
DWN
APVD
-
-
-
D
D
FEED TYPE
PNEUMATIC
140
2
244
243
A
238
242
2
53
82
1
18
70
C
69
2
56
3
1
4
28
FEED SPRING SETTING POSITION
(SHOWN FROM REAR SIDE)
33
164
30
5
140
41
34.26
0.05
REF
2
66
24
B
REF
TERMINAL SUPPORT LOCATION
1
SEE DETAIL A
DETAIL A
34
REF
8
3
0.5
50
59
C
6.7
RAM SET-UP
67
A
19
79
20
78
21
B
9
1
12
29
ITEM 30 LOCATED AT
FRONT HOLES
241
13
CAM POSITION
1
30
29
REF
REF
30mm STROKE
151
141
98
99
34
143
8
1
144
143
10
1
119
11
FEED TRACK POSITION
GUIDE BY
INSULATION BARREL
A
A
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
49
AIR FEED
PACIFIC VERSION
Shown on sheets 3 of 4
& 4 of 4
(Atlantic version shown on sheets 1 of 4
DIMENSIONS:
mm
& 2 of 4)
MATERIAL
AMP 4805 REV 31MAR2000
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
16JUL2012
CHK
16JUL2012
APVD
16JUL2012
L.ZHANG
L.ZHANG
S.XI
TE Connectivity
Harrisburg, PA 17105-3608
NAME
PRODUCT SPEC
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
DWN
-
APPLICATION SPEC
-
-
WEIGHT
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 1
Ocean Side Feed
Applicator
-
DRAWING NO
2151686
SCALE
1:2
RESTRICTED TO
SHEET
4
OF
-
4
& 2 ARE NOT REQUIRED FOR PACIFIC VERSION
REV
D