7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
RELEASED FOR PUBLICATION
PART
NUMBER
REVISION
2151832 -1
2151832 -2
G
D
FINE CRIMP HEIGHT ADJUST
MECHANICAL
FINE CRIMP HEIGHT ADJUST
G
FINE CRIMP HEIGHT ADJUST
7-2151832-1
G
MECHANICAL AND CRIMP
TOOLING KIT
MECHANICAL
7-2151832-2
G
7- 2151832 -7
A
PNEUMATIC AND CRIMP
TOOLING KIT
SIZE
WIRE
INSUL
APPLICATOR INSTRUCTIONS
408-35042
-
TE CRIMP SPECIFICATION
-
CONTACT, MALE, GENERATION Y, 0.64
114-13183
n
8
-
INSULATION DIAMETER RANGE
-
-
-
-
3
-
9
-
-
-
-
TERMINALS APPLIED
1924968-8
1-1924727-4
1924955-8
1-1924955-8
2035334-8
WIRE
SIZE
0.35mm2 OR 22 AWG
B
2
3
4
1-2035334-8
2035170-4
C1__DWG_PN_1_1
C1__DWG_PN_1_2
1-2035170-4
C1__DWG_PN_1_3
1924275-8
1456968-8
C1__DWG_PN_1_4
C1__DWG_PN_1_5
C1__DWG_PN_2_0
C1__DWG_PN_2_1
C1__DWG_PN_2_2
C1__DWG_PN_2_3
C1__DWG_PN_2_4
C1__DWG_PN_2_5
TE TERMINAL
W1__DWG_WGAUGE_1
W1__DWG_WGAUGE_2
C1__DWG_PN_3_0
1-1456968-4
1-1456968-8
C1__DWG_PN_3_1
C1__DWG_PN_3_2
1-1456574-8
C1__DWG_PN_3_3
2098762-4
1-1456841-8
CRIMP HEIGHT
mm [INCH]
6
2x0.13 OR 2X26 AWG
1
TE TERMINAL
C1__DWG_PN_1_0
0.84+/-0.02 [.033+/-.001]
0.91+/-0.03 [.036+/-.001]
TE TERMINAL
1-2138699-4
1-2138699-8
1-2098753-4
-
C1__DWG_PN_4_0
-
C1__DWG_PN_4_1
-
C1__DWG_PN_4_2
-
C1__DWG_PN_4_3
C1__DWG_PN_3_4
-
C1__DWG_PN_3_5
-
CRIMP HEIGHT
4
REFERENCE SETTING
W1__DWG_CRIMP_HT_1
W1__DWG_CRIMP_HT_2
8.8
8.2
W1__FA_SETTING_1
W1__FA_SETTING_2
RECOMMENDED SPARE PARTS
-
*WARNING
ON INSTALLATION, SET WIRE DISC TO CRIMP HEIGHT REFERENCE
SETTING FOR LARGEST WIRE SIZE. CRIMP HEIGHT REFERENCE
SETTINGS GREATER THAN THE VALUE SHOWN MAY CAUSE DAMAGE TO
THE CRIMP TOOLING. REFER TO THE INSTRUCTION SHEET FOR
PROPER SETUP AND ADJUSTMENTS.
-
REFER TO SUPPLIED INSTRUCTION SHEET FOR CLEANING, LUBRICATION AND
STORAGE OF APPLICATOR.
-
APPLY PART NUMBER 2-23419-6 LOCTITE TO THREADS OF ITEM 242.
-
CRIMP HEIGHT REFERENCE SETTING WAS THE SETTING USED WHEN THE
APPLICATOR WAS QUALIFIED AT THE FACTORY. ADJUSTMENT MAY BE
NECESSARY WHEN RUNNING APPLICATOR IN THE FIELD.
-
-
5. UNLESS SPECIFIED OTHERWISE TORQUE VALUES SHALL BE USED PER
DOCUMENT, 101-35000.
-
1
6 THIS APPLICATOR HAS BEEN DESIGNED TO APPLY WIRES WITH
THIN WALL (FLR) INSULATION.
-
7 THIS APPLICATOR EQUIPED WITH THE DOUBLE ACTING PNEUMATIC FEED WITH SENSORS,
AND IS APPLICATION SPECIFIC AND DOES NOT REQUIRE ITEMS 49 & 248.
1
-
8
1
1
9
-
1
WIRE STRIP LENGTH
2X0.13 mm² 2x0.13 mm² or 2x 26AWG; 4.3-4.5mm [.169-.177 IN]
0.35mm²or 22AWG; 4.0-4.5 mm [.157-.177 IN]
-
INSULATION DIAMETER RANGE
2X0.13mm² or 2X26AWG; 0.85-1.05mm [.033-.041 IN]
0.35mm² or 22AWG; 1.10-1.40mm [.043-.055 IN]
1
1
1
1
A
-
1
1
1
1
1
1
-
1
-
-
1
LTR
DESCRIPTION
DATE
DWN
APVD
E1
ECR-20-016024
11NOV2020
JWC
TE
F
ECR-21-113739
14SEP2021
TB
RK
G
ECR-21-114929
23SEP2021
LG
RK
G1
ECR-21-118441
25OCT2021
FZ
RK
1
1
1
1
1
1
1
2
1
1
1
4
2
1
1
1
1
1
1
2
2
1
1
1
2
1
1
1
1
1
1
2
1
1
2
1
2
1
1
-
REF
1
1
ATLANTIC VERSION
Shown on sheets 1 of 4
& 2 of 4
(Pacific version shown on sheets 3 of 4
mm
1
& 4 of 4)
MATERIAL
-
1
1
1
1
1
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
FINISH
-
-
PART NO
1
1
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
-1
1
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
DIMENSIONS:
1
-
1
1
2
-
-
1
1
1
-
1
2
1
1
1
1
1
1
-
1
1
1
-
-
1
1
1
-
1
1
1
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
2
1
2
1
2
2
1
2
1
2
1
1
1
1
1
1
1
1
2
1
1
1
2
2
1
1
1
2
1
-
1
1
2
-
1
1
1
1
1
1
2
1
-
1
4
2
-
1
1
4
-
1
1
1
1
2
1
1
2
1
2
1
4
2
1
2
1
4
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
2
1
1
1
1
-
REF REF
1
1
1
1
1
1
1
-
1
1
1
1
-
-
1
1
1
1
1
1
1
1
-
1
1
2844950-1
2119641-1
2119082-8
2079764-1
2119083-1
7-18023-7
2119580-1
2844940-1
994970-2
2844908-1
2844907-1
455888-4
1803607-3
2119791-9
2119740-1
2168078-1
2168083-2
5-18022-5
1338685-1
2168083-3
1-2168083-0
1803382-6
18023-9
2119652-1
2119653-1
1803583-9
1803515-1
1803602-1
1752356-1
2079383-5
2-2844962-4
2844992-7
1320928-2
2168083-2
1-18028-2
2119533-1
2119806-1
3-22280-3
1-356885-4
2119805-1
1803095-1
1803058-6
2119757-1
3-238011-1
1-1803019-1
455888-1
3-1633860-6
-
1
1
REF REF
1
-
-77 -72 -71 -32 -2
AMP 4805 REV 31MAR2000
P
D
-
WIRE STRIP LENGTH
TE TERMINAL
66
-
-
TE TERMINAL
TERMINAL
APPLICATION
SPECIFICATION
REVISIONS
TYPE
1.57 mm [.062]
TERMINAL NAME:
1
DIST
A
ATLANTIC VERSION TERMINATOR
INTERFACE ADAPTER
F
O
1.12 mm [.044]
TERMINAL DATA:
2
PNEUMATIC
CRIMP TOOLING KIT
APPLICATOR DATA
3
PNEUMATIC
3- 2151832 -2
CRIMP
C
FEED TYPE
DOUBLE ACTING
PNEUMATIC
WITH SENSORS
7
4
LOC
DESCRIPTION
G
5
20
ALL RIGHTS RESERVED.
BY TYCO ELECTRONICS CORPORATION.
20
6
AIR FEED MODULE
FEED CAM, AIR FEED
CAM, SNAIL, INSULATION ADJUSTMENT
WASHER, WAVE SPRING, CREST-TO-CREST
RETAINER, INSULATION DIAL
SCR, SKT HD CAP M3 X 4.0
MECHANICAL FEED ASSEMBLY
AIR FEED MODULE
COUNTER, MAGNETIC
SCREW, LOCKING
POST, LOCKING
SPACER, CRIMPER
DOCUMENTATION PACKAGE
DEPRESSOR, WIRE
TAG,IDENTIFICATION
SCREW, DRIVE, RH, RoHS, 2 x .188
SCR, SKT HD CAP, RoHS, M4 X 8.0
SCR, HEX HD CAP, M4 X 6.0
PAWL, FEED
SCR, SKT HD CAP, RoHS, M4 X 12.0
SCR, SKT HD CAP, RoHS, M4 X 10
HOLD DOWN, SPRING LOADED
SCR, SKT HD CAP M4 X 6.0
FEED CAM, PRE FEED
FEED CAM, POST FEED
APPLICATOR BASIC ASSEMBLY, SF
RAM ASSEMBLY, SF ATLANTIC
SCR, BHSC, RoHS (M8 X 25)
SUPPORT, TERMINAL
SCR, BHSC, RoHS (M4 X 20)
SPACER, CYLINDRICAL, STRIP GUIDE
ASSEMBLY, STRIP GUIDE
STRIP GUIDE
SCR, SKT HD CAP, RoHS, M4 X 8.0
WASHER, FLAT, REG M4
STRIPPER, SIDE FEED
INSERT, SHEAR
SPRING, COMPRESSION
STOP, SHEAR
SHEAR HOLDER, FRONT
FLOATING SHEAR, FRONT
ANVIL, COMBINATION
DEPRESSOR, SHEAR
BLOCK, CRIMPER SPACER
CRIMPER, INSULATION O
SPACER, CRIMPER
CRIMPER, WIRE
DWN
26APR2010
CHK
26APR2010
APVD
26APR2010
K.HUANG
L.ZHANG
U.GUO
NAME
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 3
1
2079764_APP
1
2119083
1
7-18023-7
1
2119580-1
1
2844940-1
1
COUNTER_994970
1
2844908
1
2844907
1
455888-4
1
1803607_3
1
2119791-9
1
2119740-1
2
2168078-1
1
2168083-2
1
5-18022-5
1
1338685-1
4
2168083-3
2
1-2168083-0
1
1803382-6
3
18023-9
1
2119652
1
2119653
1
1803583-9
1
1803515-1
1
1803602-1
1
1752356-1
2
2079383-5
2
2-2844962-4
1
2844992-7
1
1320928-2
1
2168083-2
2
1-18028-2
1
2119533
1
2119806
1
SIMP_3-22280-3
1
1-356885-4
1
2119805-1
1
1803095-1
1
1803058-6
..
1
ITEM_7
..
1
ITEM_6
1
2119757-1
1
3-238011-1
1
1-1803019-1
1
455888-1
1
3-1633860-6
ITEM
NO
Harrisburg, PA 17105-3608
-
WEIGHT
1
2119082-8
290
248
244
243
242
241
239
238
164
99
98
82
71
70
67
66
60
59
56
54
53
50
49
48
47
46
44
41
34
33
30
29
24
21
20
19
13
12
11
10
9
8
7
6
5
4
3
2
1
TE Connectivity
APPLICATION SPEC
-
1
2119641-1
DESCRIPTION
PRODUCT SPEC
-
1
2844950-1
Ocean Side Feed
Applicator
-
DRAWING NO
2151832
SCALE
1:2
RESTRICTED TO
SHEET
1
OF
-
4
& 4 ARE NOT REQUIRED FOR ATLANTIC VERSION
REV
G1
C
B
A
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
20
RELEASED FOR PUBLICATION
BY TYCO ELECTRONICS CORPORATION.
6
5
4
3
2
20
LOC
A
ALL RIGHTS RESERVED.
FEED TYPE
MECHANICAL
1
REVISIONS
DIST
66
P
LTR
DESCRIPTION
SEE SHEET 1
-
A
DATE
DWN
APVD
-
-
-
239
59
D
D
56
PNEUMATIC
44
A
2
244
238
243
59
242
53
2
3
50
8
82
SEE DETAIL A
1
56
C
REF
4.3
0.5
34 REF
1
C
2
FEED SPRING SETTING POSITION
(SHOWN FROM REAR SIDE)
3
1
4
TERMINAL SUPPORT LOCATION
70
5
41
DETAIL A
44.61
44
0.05
REF
66
2
164
DOUBLE ACTING
PNEUMATIC
WITH SENSORS
33
7
A
B
A
24
290
67
RAM SET-UP
19
30
B
20
59
21
29
9
241
13
30mm STROKE
ITEM 30 LOCATED AT
FRONT HOLES
12
56
SEE DETAIL A
1
CAM POSITIONS
30mm STROKE
248
48
REF
1
11
30mm STROKE
47
30
29 REF
20
46
98
99
34
54
8
1
60
54
10
1
FEED TRACK POSITION
GUIDE BY
INSULATION BARREL
7
A
A
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
49
40mm STROKE
MECHANICAL
POST FEED
AMP 4805 REV 31MAR2000
49
40mm STROKE
MECHANICAL
PRE FEED
49
7
40mm STROKE
AIR FEED
DIMENSIONS:
ATLANTIC VERSION
Shown on sheets 1 of 4
& 2 of 4
(Pacific version shown on sheets 3 of 4
mm
& 4 of 4)
MATERIAL
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
-
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
-
DWN
26APR2010
CHK
26APR2010
APVD
26APR2010
K.HUANG
L.ZHANG
U.GUO
TE Connectivity
Harrisburg, PA 17105-3608
NAME
PRODUCT SPEC
-
APPLICATION SPEC
-
-
WEIGHT
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 3
Ocean Side Feed
Applicator
-
DRAWING NO
2151832
SCALE
1:2
RESTRICTED TO
SHEET
2
OF
& 4 ARE NOT REQUIRED FOR ATLANTIC VERSION
-
4
REV
G1
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
RELEASED FOR PUBLICATION
4
3
2
LOC
PART
NUMBER
REVISION
DESCRIPTION
FEED TYPE
2- 2151832 -1
G
FINE CRIMP HEIGHT ADJUST
MECHANICAL
2- 2151832 -2
G
FINE CRIMP HEIGHT ADJUST
PNEUMATIC
7
5
20
ALL RIGHTS RESERVED.
BY TYCO ELECTRONICS CORPORATION.
20
6
4- 2151832 -2
G
FINE CRIMP HEIGHT ADJUST
DOUBLE ACTING
PNEUMATIC
WITH SENSORS
7- 2151832 -7
A
CRIMP TOOLING KIT
-
REVISIONS
DIST
A
PACIFIC VERSION TERMINATOR
INTERFACE ADAPTER
1
66
P
LTR
-
DESCRIPTION
DATE
SEE SHEET 1
DWN
APVD
-
-
-
D
D
APPLICATOR DATA
CRIMP
SIZE
WIRE
INSUL
TYPE
F
O
1.12 mm [.044]
1.57 mm [.062]
APPLICATOR INSTRUCTIONS
408-35042
TE CRIMP SPECIFICATION
3
WIRE STRIP LENGTH
TERMINAL
APPLICATION
SPECIFICATION
114-13183
n
8
-
INSULATION DIAMETER RANGE
-
-
-
-
1924968-8
1-1924727-4
1924955-8
1-1924955-8
2035334-8
WIRE
SIZE
2035170-4
1-2035170-4
C1__DWG_PN_1_2
C1__DWG_PN_1_3
1924275-8
1456968-8
C1__DWG_PN_1_4
C1__DWG_PN_1_5
0.35mm2 OR 22 AWG
1
2
C1__DWG_PN_2_1
C1__DWG_PN_2_2
C1__DWG_PN_2_3
C1__DWG_PN_2_4
C1__DWG_PN_2_5
TE TERMINAL
W1__DWG_WGAUGE_1
W1__DWG_WGAUGE_2
C1__DWG_PN_3_0
1-1456968-4
C1__DWG_PN_3_1
1-1456968-8
1-1456574-8
C1__DWG_PN_3_2
C1__DWG_PN_3_3
2098762-4
1-1456841-8
CRIMP HEIGHT
mm [INCH]
6
2x0.13 OR 2X26 AWG
B
1-2035334-8
C1__DWG_PN_1_1
C1__DWG_PN_2_0
0.84+/-0.02 [.033+/-.001]
0.91+/-0.03 [.036+/-.001]
TE TERMINAL
1-2138699-4
1-2138699-8
1-2098753-4
4
CRIMP HEIGHT
REFERENCE SETTING
W1__DWG_CRIMP_HT_1
W1__DWG_CRIMP_HT_2
8.8
8.2
W1__FA_SETTING_1
W1__FA_SETTING_2
RECOMMENDED SPARE PARTS
REFER TO SUPPLIED INSTRUCTION SHEET FOR CLEANING, LUBRICATION AND
STORAGE OF APPLICATOR.
3
APPLY PART NUMBER 2-23419-6 LOCTITE TO THREADS OF ITEM 242.
4
CRIMP HEIGHT REFERENCE SETTING WAS THE SETTING USED WHEN THE
APPLICATOR WAS QUALIFIED AT THE FACTORY. ADJUSTMENT MAY BE
NECESSARY WHEN RUNNING APPLICATOR IN THE FIELD.
*WARNING
ON INSTALLATION, SET WIRE DISC TO CRIMP HEIGHT REFERENCE
SETTING FOR LARGEST WIRE SIZE. CRIMP HEIGHT REFERENCE
SETTINGS GREATER THAN THE VALUE SHOWN MAY CAUSE DAMAGE TO
THE CRIMP TOOLING. REFER TO THE INSTRUCTION SHEET FOR
PROPER SETUP AND ADJUSTMENTS.
1
6 THIS APPLICATOR HAS BEEN DESIGNED TO APPLY WIRES WITH
THIN WALL (FLR) INSULATION.
7 THIS APPLICATOR EQUIPED WITH THE DOUBLE ACTING PNEUMATIC FEED WITH SENSORS,
AND IS APPLICATION SPECIFIC AND DOES NOT REQUIRE ITEMS 49 & 151.
8
9
1
1
WIRE STRIP LENGTH
2X0.13 mm² 2x0.13 mm² or 2x 26AWG; 4.3-4.5mm [.169-.177 IN]
0.35mm²or 22AWG; 4.0-4.5 mm [.157-.177 IN]
1
INSULATION DIAMETER RANGE
2X0.13mm² or 2X26AWG; 0.85-1.05mm [.033-.041 IN]
0.35mm² or 22AWG; 1.10-1.40mm [.043-.055 IN]
A
1
1
1
1
1
-
-
-
-
1
-
1
1
1
1
1
-
1
1
-
-
1
1
1
-
1
1
1
-
1
1
1
-
1
1
1
1
1
1
1
-
2
1
1
-
1
2
1
-
1
1
2
-
1
1
1
-
2
1
1
-
2
2
1
-
5. UNLESS SPECIFIED OTHERWISE TORQUE VALUES SHALL BE USED PER
DOCUMENT, 101-35000.
1
2
2
-
1
1
2
-
1
1
1
-
2
-
1
-
1
1
-
-
2
1
-
-
1
2
1
-
1
1
2
-
2
1
1
-
1
2
1
-
1
1
2
-
1
1
1
-
1
1
1
-
1
1
1
-
1
1
1
-
1
1
1
-
1
1
1
-
C1__DWG_PN_3_5
1
1
1
-
C1__DWG_PN_3_4
4
-
1
-
C1__DWG_PN_4_3
1
4
-
-
C1__DWG_PN_4_2
-
1
4
-
C1__DWG_PN_4_1
1
1
-
C1__DWG_PN_4_0
-
REF REF
-
-
1
1
REF
-
1
-
-
-
1
1
-
-
1
1
1
TE TERMINAL
C1__DWG_PN_1_0
-
1
1
1
-
TERMINALS APPLIED
TE TERMINAL
-
2844950-1
2119082-8
2079764-1
2119083-1
7-18023-7
2119580-1
2844940-1
994970-2
2119641-2
2168083-8
2168083-9
2119653-2
1-1803583-0
1803516-1
2844908-1
2844907-1
455888-4
1803607-3
2119791-9
2119740-1
2168078-1
5-18022-5
1338685-1
1-2168083-0
1803382-6
18023-9
2119652-1
1803602-1
1752356-1
2079383-5
2-2844962-4
2844992-7
1320928-2
2168083-2
1-18028-2
2119533-1
2119806-1
3-22280-3
1-356885-4
2119805-1
1803095-1
1803058-6
2119757-1
3-238011-1
1-1803019-1
455888-1
3-1633860-6
-
1
1
-
9
-
1
-
CONTACT, MALE, GENERATION Y, 0.64
TERMINAL NAME:
1
-
TE TERMINAL
TERMINAL DATA:
C
-
1
1
1
1
1
1
1
1
1
PART NO
-77 -42 -22 -21
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
DIMENSIONS:
PACIFIC VERSION
Shown on sheets 3 of 4
& 4 of 4
(Atlantic version shown on sheets 1 of 4
AMP 4805 REV 31MAR2000
mm
& 2 of 4)
MATERIAL
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
-
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
-
AIR FEED MODULE
CAM, SNAIL, INSULATION ADJUSTMENT
WASHER, WAVE SPRING, CREST-TO-CREST
RETAINER, INSULATION DIAL
SCR, SKT HD CAP M3 X 4.0
MECHANICAL FEED ASSEMBLY
AIR FEED MODULE
COUNTER, MAGNETIC
FEED CAM, AIR FEED
SCR, SKT HD CAP, RoHS, M4 X 16
SCR, SKT HD CAP, RoHS, M4 X 20
FEED CAM, POST FEED
APPLICATOR BASIC ASSEMBLY, SF
RAM ASSEMBLY, SF PACIFIC
SCREW, LOCKING
POST, LOCKING
SPACER, CRIMPER
DOCUMENTATION PACKAGE
DEPRESSOR, WIRE
TAG,IDENTIFICATION
SCREW, DRIVE, RH, RoHS, 2 x .188
SCR, HEX HD CAP, M4 X 6.0
PAWL, FEED
SCR, SKT HD CAP, RoHS, M4 X 10
HOLD DOWN, SPRING LOADED
SCR, SKT HD CAP M4 X 6.0
FEED CAM, PRE FEED
SCR, BHSC, RoHS (M8 X 25)
SUPPORT, TERMINAL
SCR, BHSC, RoHS (M4 X 20)
SPACER, CYLINDRICAL, STRIP GUIDE
ASSEMBLY, STRIP GUIDE
STRIP GUIDE
SCR, SKT HD CAP, RoHS, M4 X 8.0
WASHER, FLAT, REG M4
STRIPPER, SIDE FEED
INSERT, SHEAR
SPRING, COMPRESSION
STOP, SHEAR
SHEAR HOLDER, FRONT
FLOATING SHEAR, FRONT
ANVIL, COMBINATION
DEPRESSOR, SHEAR
BLOCK, CRIMPER SPACER
CRIMPER, INSULATION O
SPACER, CRIMPER
CRIMPER, WIRE
DWN
26APR2010
CHK
26APR2010
APVD
26APR2010
K.HUANG
L.ZHANG
U.GUO
NAME
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 1
1
2119083
1
7-18023-7
1
2119580-1
1
2844940-1
1
COUNTER_994970
1
2119641-2
1
2168083-8
4
2168083-9
1
2119653-2
1
1-1803583-0
1
1803516-1
1
2844908
1
2844907
1
455888-4
1
1803607_3
1
2119791-9
1
2119740-1
2
2168078-1
1
5-18022-5
1
1338685-1
2
1-2168083-0
1
1803382-6
3
18023-9
1
2119652
1
1803602-1
1
1752356-1
2
2079383-5
2
2-2844962-4
1
2844992-7
1
1320928-2
1
2168083-2
2
1-18028-2
1
2119533
1
2119806
1
SIMP_3-22280-3
1
1-356885-4
1
2119805-1
1
1803095-1
1
1803058-6
..
1
ITEM_7
..
1
ITEM_6
1
2119757-1
1
3-238011-1
1
1-1803019-1
1
455888-1
1
3-1633860-6
ITEM
NO
Harrisburg, PA 17105-3608
-
WEIGHT
1
2079764_APP
290
244
243
242
241
239
238
164
151
144
143
142
141
140
99
98
82
71
70
67
66
59
56
53
50
49
48
41
34
33
30
29
24
21
20
19
13
12
11
10
9
8
7
6
5
4
3
2
1
TE Connectivity
APPLICATION SPEC
-
1
2119082-8
DESCRIPTION
PRODUCT SPEC
-
1
2844950-1
Ocean Side Feed
Applicator
-
DRAWING NO
2151832
SCALE
1:2
RESTRICTED TO
SHEET
3
OF
-
4
& 2 ARE NOT REQUIRED FOR PACIFIC VERSION
REV
G1
C
B
A
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
RELEASED FOR PUBLICATION
BY TYCO ELECTRONICS CORPORATION.
20
6
5
4
3
2
20
LOC
A
ALL RIGHTS RESERVED.
1
REVISIONS
DIST
66
P
LTR
FEED TYPE
MECHANICAL
DESCRIPTION
SEE SHEET 1
-
A
PNEUMATIC
DWN
APVD
-
-
-
239
59
D
DATE
140
56
D
2
244
243
A
238
242
59
2
3
4.3
53
REF
8
50
0.5
34
SEE DETAIL A
56
82
1
C
REF
TERMINAL SUPPORT LOCATION
1
C
FEED SPRING SETTING POSITION
(SHOWN FROM REAR SIDE)
2
3
1
4
70
5
41
35.58
DETAIL A
140 REF
0.05
66
2
164
67
33
DOUBLE ACTING
PNEUMATIC
WITH SENSORS
7
B
RAM SET-UP
A
24
A
19
20
30
290
B
9
21
59
29
1
12
241
56
SEE DETAIL A
13
ITEM 30 LOCATED AT
FRONT HOLES
1
30
REF
29
30mm STROKE
CAM POSITIONS
30mm STROKE
30mm STROKE
7
142
REF
141
151
98
99
34
143
8
1
144
143
10
1
20
11
FEED TRACK POSITION
GUIDE BY
INSULATION BARREL
48
A
A
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
PACIFIC VERSION
Shown on sheets 3 of 4
& 4 of 4
(Atlantic version shown on sheets 1 of 4
49
MECHANICAL
POST FEED
AMP 4805 REV 31MAR2000
49
MECHANICAL
PRE FEED
49
7
AIR FEED
DIMENSIONS:
mm
& 2 of 4)
MATERIAL
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
-
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
-
DWN
26APR2010
CHK
26APR2010
APVD
26APR2010
K.HUANG
L.ZHANG
U.GUO
TE Connectivity
Harrisburg, PA 17105-3608
NAME
PRODUCT SPEC
-
APPLICATION SPEC
-
-
WEIGHT
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 1
Ocean Side Feed
Applicator
-
DRAWING NO
2151832
SCALE
1:2
RESTRICTED TO
SHEET
4
OF
-
4
& 2 ARE NOT REQUIRED FOR PACIFIC VERSION
REV
G1