7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
20
PART
NUMBER
RELEASED FOR PUBLICATION
REVISION
FEED TYPE
2151840 -1
D
FINE CRIMP HEIGHT ADJUST
MECHANICAL
5-2151840-1
D
SEAL STRIPPER CRIMPER
TERMINATING UNIT
MECHANICAL
5-2151840-2
D
7-2151840-1
D
7-2151840-2
D
7- 2151840 -7
A
CRIMP
WIRE
INSUL
FINE CRIMP HEIGHT ADJUST
-
TE TERMINAL
TE TERMINAL
TE TERMINAL
1-965982-1
n
114-18051
-
C1__DWG_PN_1_1
-
C1__DWG_PN_2_0
C1__DWG_PN_2_1
TE SEAL
828904
-
TERMINAL
APPLICATION
SPECIFICATION
-
TERMINALS APPLIED
7
TE SEAL
C1__DWG_PN_3_0
n
.171-.186 IN [4.34-4.72 mm]
TE TERMINAL
5-965982-1
8
TE TERMINAL
1-965982-3
C1__DWG_PN_1_0
-
3.4mm [.134 IN] MAX
TE CRIMP SPECIFICATION
WIRE STRIP LENGTH
INSULATION DIAMETER RANGE
C1__DWG_PN_4_0
C1__DWG_PN_3_1
CABLE DIAMETER
-
AMP MCP 2.8K FLAT TYPE RECEPTACLE
TERMINAL NAME:
TE CRIMP SPECIFICATION
TAB 2.8 X 0.8
TERMINALS APPLIED
114-18051
-
C2__DWG_PN_1_1
INSULATION DIAMETER RANGE
-
3.4mm [.134 IN] MAX
-
-
-7
3
-
-
8
TE TERMINAL
5-965982-3
C2__DWG_PN_1_0
-
-
TE SEAL
828904
C2__DWG_PN_2_0
C2__DWG_PN_2_1
C2__DWG_PN_3_0
TE SEAL
CABLE DIAMETER
C2__DWG_PN_4_0
C2__DWG_PN_3_1
7
7
-
8
-
WIRE
SIZE
0.50mm2
0.35mm2
0.25mm2
0.20mm2
CRIMP HEIGHT
mm [INCH]
W1__DWG_WGAUGE_1
W1__DWG_WGAUGE_2
W1__DWG_WGAUGE_3
W1__DWG_WGAUGE_4
1.12+/-0.03 [.044+/-.001]
1.05+/-0.03 [.041+/-.001]
1.00+/-0.03 [.039+/-.001]
0.98+/-0.03 [.039+/-.001]
CRIMP HEIGHT
REFERENCE SETTING
W1__DWG_CRIMP_HT_1
W1__DWG_CRIMP_HT_2
W1__DWG_CRIMP_HT_3
W1__DWG_CRIMP_HT_4
5.5
6.3
6.8
7.0
WIRE
SIZE
4
W1__FA_SETTING_1
W1__FA_SETTING_2
0.50mm2
0.35mm2
CRIMP HEIGHT
mm [INCH]
W2__DWG_WGAUGE_1
W2__DWG_WGAUGE_2
1.08+/-0.03 [.043+/-.001]
1.02+/-0.03 [.040+/-.001]
-
CRIMP HEIGHT
4
REFERENCE SETTING
W2__DWG_CRIMP_HT_1
W2__DWG_CRIMP_HT_2
4.2
4.8
-
W2__FA_SETTING_1
-
W2__FA_SETTING_2
5
W1__FA_SETTING_3
W1__FA_SETTING_4
-
1
2
B
3
4
5
-
RECOMMENDED SPARE PARTS
-
REFER TO SUPPLIED INSTRUCTION SHEET FOR CLEANING, LUBRICATION AND
STORAGE OF APPLICATOR.
-
APPLY PART NUMBER 2-23419-6 LOCTITE TO THREADS OF ITEM 242.
CRIMP HEIGHT REFERENCE SETTING WAS THE SETTING USED WHEN THE
APPLICATOR WAS QUALIFIED AT THE FACTORY. ADJUSTMENT MAY BE
NECESSARY WHEN RUNNING APPLICATOR IN THE FIELD.
APPLY TORQ-SEAL IN ALLEN SOCKET TO FILL HOLE AFTER FLAT HD
HAS BEEN ADJUSTED TO CORRECT HEIGHT AT QUALIFICATION.
APPLY #1-23419-5 LOC-TITE TO THREADS.
6. UNLESS SPECIFIED OTHERWISE TORQUE VALUES SHALL BE USED PER
DOCUMENT, 101-35000.
7 INSULATION RANGLE QUOTED IS THAT OF THE TERMINAL. THE SEAL
INSULATION RANGE IS 1.2-2.1mm [.047-.083 IN.]
8
-
*WARNING
ON INSTALLATION, SET WIRE DISC TO CRIMP HEIGHT REFERENCE
SETTING FOR LARGEST WIRE SIZE. CRIMP HEIGHT REFERENCE
SETTINGS GREATER THAN THE VALUE SHOWN MAY CAUSE DAMAGE TO
THE CRIMP TOOLING. REFER TO THE INSTRUCTION SHEET FOR
PROPER SETUP AND ADJUSTMENTS.
1
-
TERMINAL LUBRICANT IS RECOMMENDED.
1
-
1
1
1
-
A
1
1
1
1
-
1
1
2
1
1
1
1
1
1
1
REF
1
1
1
1
1
1
1
2
1
1
1
1
4
2
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
2
1
1
2
2
1
1
2
1
1
1
1
1
1
-
REF
1
1
1
1
1
1
1
2
1
1
1
1
4
2
2
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
2
1
1
2
2
1
1
1
1
DATE
DWN
APVD
B
ECR-18-007158
09MAY2018
TB
JDG
C
ECR-19-006079
15APR2019
LG
TE
C1
ECR-20-016280
16NOV2020
FJ
TE
D
ECR-22-136610
20APR2022
ROY
GWB
1
2
1
2
1
1
ATLANTIC VERSION
Shown on sheets 1 of 4
& 2 of 4
(Pacific version shown on sheets 3 of 4
mm
& 4 of 4)
MATERIAL
-
PART NO
1
1
-
REF REF REF REF
1
1
1
1
1
1
1
1
1
1
1
-
1
1
1
1
-
-
1
1
1
-
-
1
1
1
-
-
1
1
1
-
-
1
1
1
-
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
1
1
1
-
-
1
1
-
-
1
1
1
-
2
1
1
1
2
2
1
1
1
2
2
1
1
1
2
2
1
1
1
2
1
1
1
1
1
1
1
1
1
-
-
1
2
-
1
-
2
1
1
-
4
2
2
-
1
4
2
1
1
1
4
2
1
1
1
4
1
1
1
1
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
-
1
-
1
-77 -72 -71 -52 -51 -2
DIMENSIONS:
-1
1
-
-
1
1
1
1
1
1
1
1
-
1
1
1
1
-
1
1
1
-
1
1
1
1
-
-
1
2
1
1
1
1
2
1
1803945-4
22278-9
4-18032-3
1803944-1
2-1803583-1
2119641-1
2119082-9
2079764-1
2119083-1
7-18023-7
2119580-1
2844940-1
994970-2
1-18028-2
2119955-1
2844908-1
2844907-1
455888-7
1803607-3
2119740-1
2168078-1
2168083-2
5-18022-5
985575-3
1338685-1
2168083-3
2168083-3
18023-9
2119652-1
2119653-1
1803583-9
1803515-1
1803602-1
1-1752356-7
2079383-5
2-2844962-8
2844992-2
1-455888-4
1320928-2
2168083-2
1-18028-2
2119533-1
2119806-1
3-22280-3
1-356885-5
2119805-1
318707-1
2-1333202-7
2119781-1
238011-1
2-2119784-6
1-456403-3
1
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
AMP 4805 REV 31MAR2000
DESCRIPTION
D
F
O
WIRE STRIP LENGTH
C
LTR
-
TERMINAL DATA:
TERMINAL
APPLICATION
SPECIFICATION
P
TYPE
APPLICATOR INSTRUCTIONS
408-35042
3.70-4.30 mm [.146-.169 IN]
66
PNEUMATIC
CRIMP TOOLING KIT
3.94 mm [.155]
TERMINAL NAME:
REVISIONS
DIST
A
ATLANTIC VERSION TERMINATOR
INTERFACE ADAPTER
1
MECHANICAL
PNEUMATIC AND CRIMP
TOOLING KIT
1.57 mm [.062]
TERMINAL DATA:
2
PNEUMATIC
MECHANICAL AND CRIMP
TOOLING KIT
SIZE
3
PNEUMATIC
SEAL STRIPPER CRIMPER
TERMINATING UNIT
APPLICATOR DATA
4
LOC
DESCRIPTION
D
5
20
ALL RIGHTS RESERVED.
BY TYCO ELECTRONICS CORPORATION.
2151840 -2
D
6
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
-
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
-
TONKER
SPRING, COMPRESSION
SCR, SET, FLT PNT, M3 X 6.0
SPACER, TONKER
APPLICATOR BASIC ASSEMBLY, SF
FEED CAM, AIR FEED
CAM, SNAIL, INSULATION ADJUSTMENT
WASHER, WAVE SPRING, CREST-TO-CREST
RETAINER, INSULATION DIAL
SCR, SKT HD CAP M3 X 4.0
MECHANICAL FEED ASSEMBLY
AIR FEED MODULE
COUNTER, MAGNETIC
WASHER, FLAT, REG M4
ASSY, LUBRICATOR, SIDE FEED
SCREW, LOCKING
POST, LOCKING
SPACER, CRIMPER
DOCUMENTATION PACKAGE
TAG,IDENTIFICATION
SCREW, DRIVE, RH, RoHS, 2 x .188
SCR, SKT HD CAP, RoHS, M4 X 8.0
SCR, HEX HD CAP, M4 X 6.0
SCR, FLT SKT HD CAP M3 X 10.0
PAWL, FEED
SCR, SKT HD CAP, RoHS, M4 X 12.0
SCR, SKT HD CAP, RoHS, M4 X 12.0
SCR, SKT HD CAP M4 X 6.0
FEED CAM, PRE FEED
FEED CAM, POST FEED
APPLICATOR BASIC ASSEMBLY, SF
RAM ASSEMBLY, SF ATLANTIC
SCR, BHSC, RoHS (M8 X 25)
SUPPORT, TERMINAL
SCR, BHSC, RoHS (M4 X 20)
SPACER, CYLINDRICAL, STRIP GUIDE
ASSEMBLY, STRIP GUIDE
SPACER, CRIMPER
STRIP GUIDE
SCR, SKT HD CAP, RoHS, M4 X 8.0
WASHER, FLAT, REG M4
STRIPPER, SIDE FEED
INSERT, SHEAR
SPRING, COMPRESSION
STOP, SHEAR
SHEAR HOLDER, FRONT
FLOATING SHEAR, FRONT
ANVIL, COMBINATION
DEPRESSOR, SHEAR
BLOCK, CRIMPER SPACER
CRIMPER, INSULATION O
PREMIUM
CRIMPER, WIRE PREMIUM
DWN
04DEC2012
CHK
04DEC2012
APVD
04DEC2012
C.CHEN
S.XI
I.CRUZ
NAME
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 3
1
1803944-1
1
2-1803583-1
1
2119641-1
1
2119082-9
1
2079764_APP
1
2119083
1
7-18023-7
1
2119580-1
1
2844940-1
1
COUNTER_994970
1
1-18028-2
1
2119955-1
1
2844908
1
2844907
1
455888-7
1
1803607_3
1
2119740-1
2
2168078-1
1
2168083-2
1
5-18022-5
1
985575-3
1
1338685-1
4
2168083-3
2
2168083-3
3
18023-9
1
2119652
1
2119653
1
1803583-9
1
1803515-1
1
1803602-1
1
1-1752356-7
2
2079383-5
2
2-2844962-8
1
2844992-2
1
1-455888-4
1
1320928-2
1
2168083-2
1
1-18028-2
1
2119533
1
2119806
1
SIMP_3-22280-3
1
1-356885-5
1
2119805-1
1
318707-1
1
2-1333202-7
..
1
ITEM_7
..
1
ITEM_6
1
2119781-1
1
238011-1
1
2-2119784-6
..
1
ITEM_2
1
1-456403-3
ITEM
NO
Harrisburg, PA 17105-3608
-
WEIGHT
2
4-18032-3
300
299
298
297
292
248
244
243
242
241
239
238
164
119
113
99
98
82
71
67
66
60
59
57
56
54
53
49
48
47
46
44
41
34
33
30
29
28
24
21
20
19
13
12
11
10
9
8
7
6
5
4
3
2
1
TE Connectivity
APPLICATION SPEC
-
1
SIMP_22278-9
DESCRIPTION
PRODUCT SPEC
-
1
1803945-4
Ocean Side Feed
Applicator
-
DRAWING NO
2151840
SCALE
1:2
RESTRICTED TO
SHEET
1
OF
-
4
& 4 ARE NOT REQUIRED FOR ATLANTIC VERSION
REV
D
C
B
A
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
20
RELEASED FOR PUBLICATION
BY TYCO ELECTRONICS CORPORATION.
6
5
4
3
2
20
LOC
A
ALL RIGHTS RESERVED.
1
REVISIONS
DIST
66
P
LTR
DESCRIPTION
DATE
SEE SHEET 1
-
DWN
APVD
-
-
-
FEED TYPE
MECHANICAL
A
D
REF
5
239
D
59
56
44
PNEUMATIC
2
57 REF
5.9 REF
SHEAR DEPRESSOR DETAIL
244
243
A
242
238
53
59
3
297
8
298
82
299
C
2
1
0.8
REF
34 REF
1
C
300
SEE DETAIL A
3
1
56
4
FEED SPRING SETTING POSITION
(SHOWN FROM REAR SIDE)
TERMINAL SUPPORT LOCATION
28
5
41
44 REF
44.76
0.05
66
DETAIL A
2
164
33
57
5
RAM SET-UP
A
24
B
67
19
30
B
20
21
29
9
1
ITEM 30 LOCATED AT
REAR HOLES
12
241
CAM POSITIONS
13
47
1
11
30mm STROKE
30mm STROKE
30mm STROKE
30 REF
29 REF
113
8
292
46
98
99
34
54
8
119
1
60
54
10
1
248
48
FEED TRACK POSITION
GUIDE BY
INSULATION BARREL
A
A
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
49
40mm STROKE
MECHANICAL
POST FEED
AMP 4805 REV 31MAR2000
49
40mm STROKE
MECHANICAL
PRE FEED
49
40mm STROKE
AIR FEED
DIMENSIONS:
ATLANTIC VERSION
Shown on sheets 1 of 4
& 2 of 4
(Pacific version shown on sheets 3 of 4
mm
& 4 of 4)
MATERIAL
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
-
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
-
DWN
04DEC2012
CHK
04DEC2012
APVD
04DEC2012
C.CHEN
S.XI
I.CRUZ
TE Connectivity
Harrisburg, PA 17105-3608
NAME
PRODUCT SPEC
-
APPLICATION SPEC
-
-
WEIGHT
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 3
Ocean Side Feed
Applicator
-
DRAWING NO
2151840
SCALE
1:2
RESTRICTED TO
SHEET
2
OF
& 4 ARE NOT REQUIRED FOR ATLANTIC VERSION
-
4
REV
D
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
20
RELEASED FOR PUBLICATION
6
REVISION
DESCRIPTION
FEED TYPE
2- 2151840 -1
D
FINE CRIMP HEIGHT ADJUST
MECHANICAL
7- 2151840 -7
A
CRIMP TOOLING KIT
-
D
3
2
LOC
PART
NUMBER
2- 2151840 -2
4
20
ALL RIGHTS RESERVED.
BY TYCO ELECTRONICS CORPORATION.
5
FINE CRIMP HEIGHT ADJUST
REVISIONS
DIST
A
PACIFIC VERSION TERMINATOR
INTERFACE ADAPTER
1
66
P
LTR
-
DESCRIPTION
DATE
SEE SHEET 1
DWN
APVD
-
-
-
PNEUMATIC
D
D
CRIMP
WIRE
INSUL
APPLICATOR DATA
SIZE
TYPE
F
O
1.57 mm [.062]
3.94 mm [.155]
APPLICATOR INSTRUCTIONS
408-35042
-
1
-
TE TERMINAL
TERMINAL DATA:
TAB 2.8 X 0.8
TERMINAL NAME:
WIRE STRIP LENGTH
3.70-4.30 mm [.146-.169 IN]
C
TERMINAL
APPLICATION
SPECIFICATION
1-965982-1
114-18051
WIRE STRIP LENGTH
INSULATION DIAMETER RANGE
-
3.4mm [.134 IN] MAX
-
1-965982-3
C1__DWG_PN_1_1
-
TERMINAL
APPLICATION
SPECIFICATION
114-18051
-
TERMINALS APPLIED
C1__DWG_PN_2_0
C1__DWG_PN_2_1
TE SEAL
C1__DWG_PN_3_0
828904
n
.171-.186 IN [4.34-4.72 mm]
7
8
TE TERMINAL
C1__DWG_PN_1_0
-
TE CRIMP SPECIFICATION
TE SEAL
CABLE DIAMETER
C1__DWG_PN_4_0
C1__DWG_PN_3_1
7
TE TERMINAL
5-965982-1
C2__DWG_PN_1_1
-
-
7
C2__DWG_PN_2_1
TE SEAL
828904
C2__DWG_PN_3_0
-
CABLE DIAMETER
C2__DWG_PN_3_1
1
-
0.50mm2
0.35mm2
0.25mm2
0.20mm2
W1__DWG_WGAUGE_1
W1__DWG_WGAUGE_2
W1__DWG_WGAUGE_3
W1__DWG_WGAUGE_4
1.12+/-0.03 [.044+/-.001]
1.05+/-0.03 [.041+/-.001]
1.00+/-0.03 [.039+/-.001]
0.98+/-0.03 [.039+/-.001]
CRIMP HEIGHT
REFERENCE SETTING
-
W1__DWG_CRIMP_HT_1
W1__DWG_CRIMP_HT_2
W1__DWG_CRIMP_HT_3
W1__DWG_CRIMP_HT_4
5.5
6.3
6.8
7.0
W1__FA_SETTING_1
W1__FA_SETTING_2
W1__FA_SETTING_3
WIRE
SIZE
0.50mm2
0.35mm2
CRIMP HEIGHT
4
REFERENCE SETTING
CRIMP HEIGHT
mm [INCH]
W2__DWG_WGAUGE_1
W2__DWG_WGAUGE_2
1.08+/-0.03 [.043+/-.001]
1.02+/-0.03 [.040+/-.001]
W2__DWG_CRIMP_HT_1
W2__DWG_CRIMP_HT_2
4.2
4.8
2
RECOMMENDED SPARE PARTS
REFER TO SUPPLIED INSTRUCTION SHEET FOR CLEANING, LUBRICATION AND
STORAGE OF APPLICATOR.
3
APPLY PART NUMBER 2-23419-6 LOCTITE TO THREADS OF ITEM 242.
4
CRIMP HEIGHT REFERENCE SETTING WAS THE SETTING USED WHEN THE
APPLICATOR WAS QUALIFIED AT THE FACTORY. ADJUSTMENT MAY BE
NECESSARY WHEN RUNNING APPLICATOR IN THE FIELD.
2
2
2
1
1
1
-
1
1
-
1
1
-
1
1
-
1
1
-
1
1
-
1
1
-
1
1
-
1
1
-
1
1
1
1
1
-
1
-
-
-
-
-
-
1
-
1
1
1
1
1
-
1
-
1
A
1
2
-
1
1
1
-
1
1
1
-
TERMINAL LUBRICANT IS RECOMMENDED.
2
-
-
8
2
1
-
1
1
2
-
1
1
1
-
1
1
1
-
7 INSULATION RANGLE QUOTED IS THAT OF THE TERMINAL. THE SEAL
INSULATION RANGE IS 1.2-2.1mm [.047-.083 IN.]
2
1
-
1
1
2
-
APPLY TORQ-SEAL IN ALLEN SOCKET TO FILL HOLE AFTER FLAT HD
HAS BEEN ADJUSTED TO CORRECT HEIGHT AT QUALIFICATION.
APPLY #1-23419-5 LOC-TITE TO THREADS.
6. UNLESS SPECIFIED OTHERWISE TORQUE VALUES SHALL BE USED PER
DOCUMENT, 101-35000.
1
1
-
5
1
1
-
1
1
1
-
B
1
1
-
*WARNING
ON INSTALLATION, SET WIRE DISC TO CRIMP HEIGHT REFERENCE
SETTING FOR LARGEST WIRE SIZE. CRIMP HEIGHT REFERENCE
SETTINGS GREATER THAN THE VALUE SHOWN MAY CAUSE DAMAGE TO
THE CRIMP TOOLING. REFER TO THE INSTRUCTION SHEET FOR
PROPER SETUP AND ADJUSTMENTS.
1
1
-
5
1
1
-
W1__FA_SETTING_4
1
1
-
W2__FA_SETTING_2
1
1
-
W2__FA_SETTING_1
1
1
-
8
4
-
-
4
1
4
-
CRIMP HEIGHT
mm [INCH]
-
1
-
WIRE
SIZE
-
REF REF
7
1
1
C2__DWG_PN_4_0
1
-
-
TE SEAL
1
1
-
C2__DWG_PN_2_0
1
1
-
-
1
1
-
8
TE TERMINAL
5-965982-3
C2__DWG_PN_1_0
-
3.4mm [.134 IN] MAX
1
1
3
2
1
-
INSULATION DIAMETER RANGE
1
2
-
AMP MCP 2.8K FLAT TYPE RECEPTACLE
TERMINAL NAME:
C1__DWG_PN_4_0
-
TERMINALS APPLIED
TE TERMINAL
n
TE TERMINAL
TERMINAL DATA:
TE CRIMP SPECIFICATION
1
-
1803945-4
22278-9
4-18032-3
1803944-1
2119082-9
2079764-1
2119083-1
7-18023-7
2119580-1
2844940-1
994970-2
2119641-2
2168083-8
2168083-9
2119653-2
1-1803583-0
1803516-1
1-18028-2
2119955-1
2844908-1
2844907-1
455888-7
1803607-3
2119740-1
2168078-1
5-18022-5
985575-3
1338685-1
2168083-3
18023-9
2119652-1
1803602-1
1-1752356-7
2079383-5
2-2844962-8
2844992-2
1-455888-4
1320928-2
2168083-2
1-18028-2
2119533-1
2119806-1
3-22280-3
1-356885-5
2119805-1
318707-1
2-1333202-7
2119781-1
238011-1
2-2119784-6
1-456403-3
1
-
1
1
PART NO
-77 -22 -21
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
DIMENSIONS:
PACIFIC VERSION
Shown on sheets 3 of 4
& 4 of 4
(Atlantic version shown on sheets 1 of 4
AMP 4805 REV 31MAR2000
mm
& 2 of 4)
MATERIAL
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
-
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
-
TONKER
SPRING, COMPRESSION
SCR, SET, FLT PNT, M3 X 6.0
SPACER, TONKER
CAM, SNAIL, INSULATION ADJUSTMENT
WASHER, WAVE SPRING, CREST-TO-CREST
RETAINER, INSULATION DIAL
SCR, SKT HD CAP M3 X 4.0
MECHANICAL FEED ASSEMBLY
AIR FEED MODULE
COUNTER, MAGNETIC
FEED CAM, AIR FEED
SCR, SKT HD CAP, RoHS, M4 X 16
SCR, SKT HD CAP, RoHS, M4 X 20
FEED CAM, POST FEED
APPLICATOR BASIC ASSEMBLY, SF
RAM ASSEMBLY, SF PACIFIC
WASHER, FLAT, REG M4
ASSY, LUBRICATOR, SIDE FEED
SCREW, LOCKING
POST, LOCKING
SPACER, CRIMPER
DOCUMENTATION PACKAGE
TAG,IDENTIFICATION
SCREW, DRIVE, RH, RoHS, 2 x .188
SCR, HEX HD CAP, M4 X 6.0
SCR, FLT SKT HD CAP M3 X 10.0
PAWL, FEED
SCR, SKT HD CAP, RoHS, M4 X 12.0
SCR, SKT HD CAP M4 X 6.0
FEED CAM, PRE FEED
SCR, BHSC, RoHS (M8 X 25)
SUPPORT, TERMINAL
SCR, BHSC, RoHS (M4 X 20)
SPACER, CYLINDRICAL, STRIP GUIDE
ASSEMBLY, STRIP GUIDE
SPACER, CRIMPER
STRIP GUIDE
SCR, SKT HD CAP, RoHS, M4 X 8.0
WASHER, FLAT, REG M4
STRIPPER, SIDE FEED
INSERT, SHEAR
SPRING, COMPRESSION
STOP, SHEAR
SHEAR HOLDER, FRONT
FLOATING SHEAR, FRONT
ANVIL, COMBINATION
DEPRESSOR, SHEAR
BLOCK, CRIMPER SPACER
CRIMPER, INSULATION O
PREMIUM
CRIMPER, WIRE PREMIUM
DWN
04DEC2012
CHK
04DEC2012
APVD
04DEC2012
C.CHEN
S.XI
I.CRUZ
NAME
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 1
1
1803944-1
1
2119082-9
1
2079764_APP
1
2119083
1
7-18023-7
1
2119580-1
1
2844940-1
1
COUNTER_994970
1
2119641-2
1
2168083-8
4
2168083-9
1
2119653-2
1
1-1803583-0
1
1803516-1
1
1-18028-2
1
2119955-1
1
2844908
1
2844907
1
455888-7
1
1803607_3
1
2119740-1
2
2168078-1
1
5-18022-5
1
985575-3
1
1338685-1
2
2168083-3
3
18023-9
1
2119652
1
1803602-1
1
1-1752356-7
2
2079383-5
2
2-2844962-8
1
2844992-2
1
1-455888-4
1
1320928-2
1
2168083-2
1
1-18028-2
1
2119533
1
2119806
1
SIMP_3-22280-3
1
1-356885-5
1
2119805-1
1
318707-1
1
2-1333202-7
..
1
ITEM_7
..
1
ITEM_6
1
2119781-1
1
238011-1
1
2-2119784-6
..
1
ITEM_2
1
1-456403-3
ITEM
NO
Harrisburg, PA 17105-3608
-
WEIGHT
2
4-18032-3
300
299
298
297
244
243
242
241
239
238
164
151
144
143
142
141
140
119
113
99
98
82
71
67
66
59
57
56
53
49
48
41
34
33
30
29
28
24
21
20
19
13
12
11
10
9
8
7
6
5
4
3
2
1
TE Connectivity
APPLICATION SPEC
-
1
SIMP_22278-9
DESCRIPTION
PRODUCT SPEC
-
1
1803945-4
Ocean Side Feed
Applicator
-
DRAWING NO
2151840
SCALE
1:2
RESTRICTED TO
SHEET
3
OF
-
4
& 2 ARE NOT REQUIRED FOR PACIFIC VERSION
REV
D
C
B
A
7
8
THIS DRAWING IS UNPUBLISHED.
C
COPYRIGHT
RELEASED FOR PUBLICATION
BY TYCO ELECTRONICS CORPORATION.
20
6
5
4
3
2
20
LOC
A
ALL RIGHTS RESERVED.
1
REVISIONS
DIST
66
P
LTR
DESCRIPTION
DATE
SEE SHEET 1
-
DWN
APVD
-
-
-
FEED TYPE
MECHANICAL
A
D
REF
5
239
140
59
D
2
244
5.9 REF
56
PNEUMATIC
243
242
A
57
REF
SHEAR DEPRESSOR DETAIL
2
3
0.8
238
53
REF
8
297
34
REF
59
298
82
299
C
SEE DETAIL A
TERMINAL SUPPORT LOCATION
1
C
1
300
56
3
1
4
28
FEED SPRING SETTING POSITION
(SHOWN FROM REAR SIDE)
5
41
140
35.73
REF
0.05
66
164
DETAIL A
67
2
57
33
A
24
B
5
RAM SET-UP
19
20
30
B
9
21
29
1
12
241
13
CAM POSITIONS
30mm STROKE
1
30 REF
REF
29
30mm STROKE
30mm STROKE
142
ITEM 30 LOCATED AT
REAR HOLES
151
141
113
48
8
98
99
34
143
8
1
144
143
10
1
119
FEED TRACK POSITION
GUIDE BY
INSULATION BARREL
11
A
A
THIS DRAWING IS A CONTROLLED DOCUMENT FOR TYCO ELECTRONICS CORPORATION
IT IS SUBJECT TO CHANGE AND THE CONTROLLING ENGINEERING ORGANIZATION
SHOULD BE CONTACTED FOR THE LATEST REVISION.
PACIFIC VERSION
49
MECHANICAL
POST FEED
49
MECHANICAL
PRE FEED
49
AIR FEED
Shown on sheets 3 of 4
& 4 of 4
(Atlantic version shown on sheets 1 of 4
DIMENSIONS:
mm
& 2 of 4)
MATERIAL
AMP 4805 REV 31MAR2000
-
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
-
0 PLC
1 PLC
2 PLC
3 PLC
4 PLC
ANGLES
FINISH
-
DWN
04DEC2012
CHK
04DEC2012
APVD
04DEC2012
C.CHEN
S.XI
I.CRUZ
TE Connectivity
Harrisburg, PA 17105-3608
NAME
PRODUCT SPEC
-
APPLICATION SPEC
-
-
WEIGHT
SIZE
-
A1
CAGE CODE
00779
Customer Accessible Production Drawing
SHEETS 1
Ocean Side Feed
Applicator
-
DRAWING NO
2151840
SCALE
1:2
RESTRICTED TO
SHEET
4
OF
-
4
& 2 ARE NOT REQUIRED FOR PACIFIC VERSION
REV
D