86 Compensated
•
316L SS Pressure Sensor
•
Small Profile
•
0 - 100mV Output
•
Absolute and Gage
•
Temperature Compensated
I heard
DESCRIPTION
The 86 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor
packaged in a 316L stainless steel housing. The 86 compensated is designed for o-ring mounting and OEM
applications where compatibility with corrosive media is required.
The sensing package utilizes silicon oil to transfer pressure from the 316L stainless steel diaphragm to
the sensing element. A ceramic substrate is attached to the package that contains laser-trimmed resistors for
temperature compensation and offset correction. An additional laser trimmed resistor is included which can be
used to adjust an external differential amplifier and provide span interchangeability to within ±1%.
Please refer to the 86 uncompensated and constant voltage datasheets for more information on
different features of the 86.
FEATURES
•
•
•
•
•
APPLICATIONS
O-Ring Mount
-40ºC to +125ºC Operating
Temperature Range
±0.2% Pressure Non Linearity
1.0% Interchangeable Span
(provided by gain set resistor)
Solid State Reliability
•
•
•
•
•
•
Medical Instruments
Process Control
Fresh & Waste Water Measurements
Partial Vacuum Gas Measurement
Pressure Transmitters
Tank Level Systems (RV & Industrial)
STANDARD RANGES
Range
0 to 5
0 to 15
0 to 30
0 to 50
0 to 100
0 to 300
0 to 500
86C
psig
•
•
•
•
•
•
•
psia
•
•
•
•
•
•
•
www.meas-spec.com
1/4
August 2011
86 Compensated
PERFORMANCE SPECIFICATIONS
Supply Current: 1.5mA
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS
Span
Zero Pressure Output
≥015PSI
005PSI
MIN
TYP
MAX
50
100
-2.0
0
0.2
-0.1
±0.02
0.10
-0.05
6.5K
2.0K
Pressure Non Linearity
-0.2
Pressure Hysteresis
-0.10
Repeatability
NOTES
TYP
MAX
150
75
100
150
mV
1
2.0
-1.0
0
1.0
mV
2
0.1
%Span
3
±0.02
0.05
%Span
±0.02
±0.02
%Span
Ω
6.0K
Ω
2.5K
Output Resistance
4.0K
7.0K
4.0K
Temperature Error – Span
-1.0
1.0
-0.75
0.75
%Span
4
Temperature Error – Offset
-1.5
1.5
-0.50
0.50
%Span
4, 5
Thermal Hysteresis – Span
-0.25
±0.05
0.25
-0.25
±0.05
0.25
%Span
4
Thermal Hysteresis – Offset
-0.25
±0.05
0.25
-0.25
±0.05
0.25
%Span
4
±0.10
Long Term Stability – Offset
5M
Insulation Resistance (50Vdc)
0.5
50M
1.5
±0.10
2.0
0.5
%Span/Year
1.5
2.0
50M
1.0
Response Time (10% to 90%)
0.1
Pressure Overload
%Span/Year
5M
Output Noise (10Hz to 1KHz)
1.0
0.1
50
6
Ω
7
Ω
8
ms
4X
0
mA
uV p-p
3X
Pressure Burst
Compensated Temperature
±0.10
±0.25
Supply Current
Output Load Resistance
3.5K
5.8K
Input Resistance
Long Term Stability – Span
5.0K
UNITS
MIN
3X
Rated
4X
Rated
-20
+85
°C
9
Operating Temperature
-20
+70
-40
+125
ºC
10
Storage Temperature
-50
+125
-50
+125
ºC
10
Media – Pressure Port
Liquids and Gases compatible with 316/316L Stainless Steel
Media – Reference Port
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber, and 316/316L Stainless
Steel
Notes
1. For amplified output circuits, 3.012V ±1% interchangeability with gain set resistor. See application schematic.
2. Measured at vacuum for absolute (A) and at ambient for gage (G).
3. Best fit straight line.
4. Over the compensated temperature range with respect to 25°C.
5. 15-psi range sensors have a temperature error of °0.75% (max) of zero from -20°C to +85°C.
6. Guarantees output/input ratiometricity.
7. Load resistance to reduce measurement errors due to output loading.
8. Between case and sensing element.
9. The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
10. Maximum temperature range for product with standard cable and connector is -20°C to +105°C.
86C
www.meas-spec.com
2/4
August 2011
86 Compensated
DIMENSIONS
CONNECTIONS
86C
www.meas-spec.com
3/4
August 2011
86 Compensated
APPLICATION SCHEMATIC
ORDERING INFORMATION
86 - 005 G - C T
Vent (T = Tube, Blank = No Tube)
Electrical (C = Ribbon Cable with Connector,
R = Ribbon Cable, P = Solder Pads)
Type (A = Absolute, G = Gage)
Pressure Range
Model
NORTH AMERICA
EUROPE
Measurement Specialties
45738 Northport Loop West
Fremont, CA 94538
Tel: 1-800-767-1888
Fax: 1-510-498-1578
Sales: pfg.cs.amer@meas-spec.com
Measurement Specialties
(Europe), Ltd.
26 Rue des Dames
78340 Les Clayes-sous-Bois, France
Tel: +33 (0) 130 79 33 00
Fax: +33 (0) 134 81 03 59
Sales: pfg.cs.emea@meas-spec.com
ASIA
Measurement Specialties
(China), Ltd.
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District, Shenzhen 518057
China
Tel: +86 755 3330 5088
Fax: +86 755 3330 5099
Sales: pfg.cs.asia@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the
manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement
Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different
applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement
Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
86C
www.meas-spec.com
4/4
August 2011
很抱歉,暂时无法提供与“86-030A-C”相匹配的价格&库存,您可以联系我们找货