0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
9-1423674-1

9-1423674-1

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

    W54-XC2A4B10-40=CKTBKR,THERM,P

  • 数据手册
  • 价格&库存
9-1423674-1 数据手册
Quick Reference Guide INDUSTRIAL RELAYS RELAYS, CONTACTORS & CIRCUIT BREAKERS INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS RELAYS, CONTACTORS & CIRCUIT BREAKERS TE Connectivity (TE) has extensive capabilities in the design and manufacture of relays and a broad portfolio of switching solutions for demanding, high performance applications. These relay products are remotely actuated to control electrical power flow by either interrupting or completing an electrical circuit. Complying with standardized PCB footprints, TE offers a wide range of inrush current capabilities and addresses the complete spectrum of requirements for production lines, robotics, elevators, control panels, CNC machines, motion control systems, lighting, building systems, solar, HVAC, and an array of safety-critical applications. Through agency approved test labs, we ensure that our relays are tested to meet the expectations of the industry. Whether you are designing for harsh or indoor applications, TE delivers high quality relays from state-of-the-art production lines. SOLAR HVAC LIGHTING ROBOTICS BUILDING SYSTEMS INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS CONTENTS RELAYS, CONTACTORS & CIRCUIT BREAKERS Power PCB Relays up to 16A.......................................4 Power PCB Relays up to 50A+.....................................11 Force Guided Relays......................................................14 Panel Plug-In Relays......................................................16 Signal Relays....................................................................22 High Frequency Relays.................................................27 Solid State Relays...........................................................28 Circuit Breakers..............................................................33 Transformers....................................................................36 MOTION CONTROL WHAT’S INSIDE PAGE 3 Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers Key Features SCHRACK PE SCHRACK RE/REL PCJ Low height 10.0mm Sensitive 200mW coil Mono-or bistable coil WG type available (IEC 60335-1) Miniature PCB relays PCB area 200mm2 Slim outline Sensitive coil 200mW WG type available (IEC 60335-1) Ambient temperature up to 105°C Industrial electronics White goods Measurement and control PLC; Timers; I/O cards Temperature control White goods Home applications HVAC 1 form C (CO) 250VAC 5A (CO) 6A (NO) 1250VA AgNi 90/10, AgSnO2 1 form A (NO) 250VAC 6/5A 1 form A (NO) 250VAC 3A/5A (WG type) 1500/1250VA AgNi 0.15, AgNi 90/10 1) see footnote below 1) see footnote below 750VA/1250VA (WG type) AgNi 100mA at 5VDC DC, bistable 3 to 48VDC 200mW DC 5 to 48VDC 200/360mW DC 5 to 24VDC 200mW 1000Vrms 4000Vrms 1000Vrms 4000/3000Vrms 750Vrms 4000Vrms 3.2/4mm 4/4mm 8/>8mm + 85°C RTII, RTIII +70°C (RE)/ + 85°C (REL) RTIII(RE), RTII(REL) + 85/ +105°C (WG type) RTII, RTIII THT PCB 20x10x10mm THT PCB 20x10x10.6mm/20.7x10.7x12mm THT PCB 20.4x7x15mm SCHRACK PE SCHRACK RE SCHRACK REL PCJ Wash tight Footprint 2) see footnote below Applications Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions Accessories Link to datasheet 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers Key Features PCH OJ/OJE/T77 PCN/PCNH Compact size WG type available (IEC 60335-1) TV-3 ratings for NO contact Miniature size Sensitive coil 200mW 4kV coil-contacts (OJ/OJT) Meet UL TV-5 ratings (OJT) 1 pole 3A/5A Only 5mm wide Allows high function/packaging density RoHS compliant (Directive 2002/95/EC) 4 – .05 DIA (1.3) .067 (1.71) Footprint 2) see footnote below .300 ± .004 (7.6 ± .1) .100 ± .004 (2.54 ± .1) .500 ± .004 (12.7 ± .1) Applications 1a Appliances HVAC Refrigerators, microwave ovens Appliances HVAC Industrial control PLC Temperature control I/O modules 1 form C (CO), 1 form A (NO) 277VAC/30VDC 3/5/10A 1400VA/150W (NO) 850VA/90W (NC) AgSnO2 100mA at 5VDC 1 form A (NO) 250VAC/28VDC 3/5/8/10A 720 to 2500VA/ 90 to 240W Ag, AgCdO, AgSnO2 1 form A (NO) 250VAC 3A/5A 750VA /1250VA 1) see footnote below AgNi gold plated 100mA at 5VDC DC, sensitive 3 to 48VDC 200/400mW DC, sensitive 3 to 48VDC 200/250/450mW DC 3 to 24VDC 100mW/120mW 750Vrms 4000Vrms 750/1000Vrms 3000/4000Vrms 750Vrms 3000Vrms 1.6/3.2mm 1.6/3.2mm and 3.2/6.4mm 3.5mm +70°C (standard)/+85°C (WG type) RTII, RTIII up to 85°C +85°C RTII, RTIII RTIII THT PCB 20x10x15.2mm THT PCB 18.2x10.2x14.7mm THT PCB 20x5x12.5mm PCH OJ/OJE T77 PCN Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Accessories Link to datasheet 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. PAGE 5 Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers SCHRACK SNR SCHRACK RYII SCHRACK MSR/T75 5mm wide slim outline Strong coil pins for DIN-rail socket Allows high function/ packaging density Reflow solderable version Low height 12.3mm Reinforced insulation Pinnings 3.2mm and 5mm High inrush currents with AgSnO contacts 4kV/8mm coil-contact Reinforced insulation Interface technology PLC, timers, Heating control Interface technology HVAC, PLC, Power supplies Domestic appliances Interface technology HVAC, PLC, Power supplies Domestic appliances Contact arrangement 1 form C (CO), 1 form A (NO) Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 250VAC 6A 1500VA AgSnO2 , AgSnO2 gold plated 100mA at 12VDC 1 form C (CO), 1 form A (NO), 1 from B (NC) 250VAC 8A 2000VA AgNi0.15, AgSnO2, AgNi 0.15 gold plated 1 form C (CO) 1 form A (NO) 250VAC 8/10A 2000VA AgNi90/10, AgSnO2 DC 5 to 48VDC 170/217mW DC 5 to 60VDC (223 - 257)mW DC 3 to 60VDC (212-262)mW 1000Vrms 4000Vrms 1000Vrms 5000Vrms 1000Vrms 4000Vrms 6/8mm 8/8mm 8/8mm Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +85°C RTIII +70°C RTII, RTIII +85°C RTII, RTIII THT PCB or on socket 28x5x15mm THT, THR PCB or on socket 28.5x10.1x12.3mm THT PCB 28.6x10x15mm Accessories DIN rail sockets PCB sockets Link to datasheet SCHRACK SNR SCHRACK RYII Key Features Footprint 2) see footnote below Applications Contact Data 1) see footnote below 1) see footnote below Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS SCHRACK MSR 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers Key Features SCHRACK RZ SCHRACK RT SCHRACK RT INRUSH High performance version available Reinforced insulation High ambient temperature version (105°C) WG type available (IEC 60335-1) AgNi and AgSnO contact versions THR (reflow) version DC and AC coil Mono-or bistable coil Reinforced insulation WG type available (IEC 60335-1) High ambient temperature version (105°C) THR (reflow) version Sensitive version Bifurcated contacts For inrush peak currents up to 80A Mono-or bistable coil Reinforced insulation WG type available (IEC 60335-1) Household appliances HVAC, Home automation Machine control, Energy control HVAC, Home automation, Machine control, Energy control Switching cabinet, Interface modules Lighting applications, Movement detectors, Motors control, Domestic appliances 1 form C (CO) 1 form A (NO) 250VAC 16A 4000VA AgNi90/10, AgSnO2 1 form C (CO), 1 from A (NO) 2 form C (CO), 2 form A (NO) 250VAC 2X8/16A 2X2000/4000VA AgNi90/10, AgSnO2 1 form C (CO) 1 from A (NO) 250VAC 16A 4000VA AgNi90/10, AgSnO2 DC 5 to 48VDC 400mW DC, AC, bistable 5 to 110VDC/24 to 230VAC 400mW/0.75VA DC, bistable 5 to 11VDC 400mW 1000Vrms 5000Vrms 1000Vrms 5000Vrms 2500Vrms 1000Vrms 5000Vrms >10/10mm >10/10mm >10/10mm +85°C +105°C (HOT type) +70°C (transparent cover type) RTII, RTIII +75°C (AC type) +85°C +85°C RTII, RTIII RTII THT PCB 29x12.7x15.7mm THT, THR (DC and AC type) PCB or on socket 29x12.7x15.7mm THT PCB or socket 29x12.7x15.7mm Footprint 2) see footnote below Applications Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1) see footnote below 1) see footnote below 1) see footnote below Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Accessories Link to datasheet PCB and DIN rail sockets SCHRACK RZ SCHRACK RT 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. SCHRACK RT INRUSH 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. PAGE 7 Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers Key Features SCHRACK RTX SCHRACK RT iPOWER SCHRACK RP3SL Inrush peak currents up to 370A Bistable coil Reinforced insulation 16A rated fluorescent load acc. EN60669-1 8A electronic ballast acc. UL508 1 1/2 HP motor load acc. UL508 High Inrush peak currents up to 165A (20ms) and 800A (200µs) Mono-or bistable coil RTS3T: 5A Electronic ballast acc. UL508 RTSET: 8A Electronic ballast acc. UL508 Test tab (manual operator) optional for RTT3T bistable versions Inrush peak currents up to 120A (20ms) Mono-or bistable coil Sealed version available Footprint 16A, pinning 5mm 2) see footnote below S0418-CM Applications Lighting control systems Motion sensors Home automation applications LED lighting systems, Lighting control, Movement detectors Filament and incandescent lamp Motor control Lighting control Motor control Building automation Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material 1 from A (NO) 250VAC 16A 4000VA W (pre-make contact) + AgSnO2 1 from A (NO) 250VAC 16A 4000VA W (pre-make contact) + AgSnO2 AgSnO2 1 form A, 1 NO 250VAC 16A 4000VA AgSnO2 Min. recommended contact load 1) see footnote below 1) see footnote below 100mA at 12VDC Bistable 5 to 48VDC 650mW/665mW DC, bistable 5 to 11VDC 400mW DC 6 to 110VDC 500mW 1250Vrms 5000Vrms 1250Vrms 5000Vrms 2000Vrms 4000Vrms min. 6/6mm 10/10mm 8/8mm +70°C RTII RTS3L/RTS3T +105°C, RTSET +85°C RTII +70°C RTII, RTIII THT PCB 29.1x12.7x16mm THT PCB 29x12.7x15.7mm (RTS3T), 29x12.7x16.0mm (RTS3L) THT PCB 29x12.6x25.5mm SCHRACK RTX SCHRACK RT IPOWER SCHRACK RP3SL Contact Data Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Accessories Link to datasheet 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Power PCB Relays up to 16A Relays, Contactors & Circuit Breakers Key Features SCHRACK RP-2POLE 1.5MM SCHRACK PB/PBH SCHRACK ORWH 2 pole 8A 1.5mm contact gap per pole Creepage distance complies with IEC 60950 Sealed version available Compact and simple design gives high process security High ambient temperature version up to 105°C (PBH) WG type acc. IEC 60335-1 Compact relay with 1 form A and 1 form C contact arrangement 10A switching capacity Footprint .236 ± .004 (6.0 ± .1) 2) see footnote below .236 ± .004 (6.0 ± .1) .079 ± .004 (2.0 ± .1) Applications .48 ± .004 (12.2 ± .1) Domestic appliances UPS Solar Inverter White goods Small home appliances Heating temperature controllers Appliances HVAC Emergency lighting Contact arrangement 2 form A, 2 NO Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 250VAC 8A 2000VA AgSnO2 100mA at 12VDC 1 form C (CO) 1 form A (NO) 250VAC 10A 2500VA AgNi90/10, AgSnO 1) see footnote below 1 form C (CO) 1 form A (NO) 277VAC/28VDC 10A 2770VA/360W AgZnO, AgNi 100mA at 5VDC DC 5 to 110VDC 780mW DC 5 to 48VDC 360mW/500mW DC 5 to 24VDC 360mW 25000Vrms 5000Vrms 300Vrms 1000Vrms 2500Vrms 750Vrms 1500Vrms 7/8mm 3/4mm / 4/5mm 3.2mm +40°C RTII, RTIII +85°C/+105°C RTII +85°C RTII, RTIII THT PCB 29x12.6x25.5mm THT PCB 15x15x20mm THT PCB 19.0x15.5x15.8mm SCHRACK RP-2POLE 1.5MM SCHRACK PB SCHRACK PBH SCHRACK ORWH 5 – .05 DIA (1.3) Contact Data Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Accessories Link to datasheet 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. PAGE 9 Power PCB Relays up to 50A+ Relays, Contactors & Circuit Breakers Key Features Potter & Brumfield T9G Potter & Brumfield T9A Potter & Brumfield T9S/T9V High breaking capacity PCB and quick connect connections 4kV coil-contact Minimum board space (29mm x 21.5mm) UL-class F as standard High breaking capacity PCB and quick connect and chassis mount version UL-class F as standard Open version available 1 pole 35A (T9S)/40A (T9V) Contact gap 1.5mm/1.8mm min. Ambient temperature up to 85°C at 35A Production in accordance to IEC 60335-1 RoHS compliant (Directive 2002/95/EC) Footprint .140 MAX. (3.56) 2) see footnote below .250 MAX. (6.35) .300 .100 (7.62) (2.54) .600 (15.24) .500 (12.7) .150 (3.81) Applications .550 (13.97) .700 (17.78) HVAC, Appliances Industrial control Energy management HVAC Appliances Industrial controls Photovoltaic inverter Electrical vehicle loading stations Electrical vehicle 1 form C (1 CO) 1 form B (1 NC) 1 form A (1 NO) 250VAC 1 form C (1 CO) 1 form B (1 NC) 1 form A (1 NO) 250VAC 1 form A (1NO) 30A AgSnO2 1A at 12VAC/VDC 30A 7500VA AgCdO, AgSnInO 1A at 5VDC or 12VAC 277VAC (1.5mm gap), 250VAC (1.8mm gap) 35A (T9S) , 40A (T9V) 9695VA (T9S), 10000VA (T9V) AgNi 1A at 5VDC/12VAC DC 5 to 110VDC 900mW DC 6 to 48VDC 1W/900mW Monostable 12VDC 2.25W 1500Vrms 4000Vrms 1500Vrms 2500Vrms 2500Vrms 4000Vrms >6.4mm/>8mm 3.1/6.3mm 3/4mm +105°C RTII, RTIII +85°C RT0, RTI, RTII, RTIII +85°C RTII/RTIII THT/Quick connect PCB 29x21.5x15.7mm THT/Quick connect PCB, panel mount 32.3x27.4x20.4mm PCB PCB 32x27x20mm POTTER & BRUMFIELD T9G POTTER & BRUMFIELD T9A Potter & Brumfield T9V Potter & Brumfield T9S Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Accessories Link to datasheet 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Power PCB Relays up to 50A+ Relays, Contactors & Circuit Breakers Key Features Potter & Brumfield T92 PCF PCFN SOLAR Switching capacity 7500VA DC or AC coil 4kV/8mm coil-contact PCB or quick connect connections or chassis mount Quick connect terminal for load (PCF only) Height 26.5mm Meet 4kV dielectric voltage between coil and contact Ambient temperature 85°C Specially designed to meet the requirements for solar Contact gap 1.5mm/1.8mm min. 200mW hold power Footprint 2) see footnote below .309 (7.85) .585 (14.86) 1.618 (41.10) .185 (4.70) 1.09 ± .008 (27.6 ± .2) .244 (6.2) .472 ± .008 .228 (12.0 ± .2) (5.8) .365 (9.27) .630 (16.00) .203 TYP. (5.16) .162 (4.12) Applications 2 – .071 DIA (1.8) 1.000 (25.40) .052 TYP. (1.32) .072 TYP. (1.83) 2 – .063 DIA (1.6) .472 (12.0) .394 (10.0) HVAC Residential/commercial appliances Industrial controls Applicances HVAC Office machines Photovoltaic Inverter 2 form C (2 CO) 2 form A (2 NO) 400VAC 30A 7500VAC AgCdO, AgSnInO 500mA (NO)/ 100mA (NC) at 12VAC 1 form A (1 NO) 1 form A (1 NO) 250VAC 25A 6370VA Visit TE.com for more information 100mA at 5VDC 277VAC 26A 7200VA AgSnO2 100mA at 5VDC DC, AC 5 to 110VDC/12 to 240VAC 1.7W/4.0VA DC 6 to 24VDC 900mW DC 12VDC and 24VDC 1.5W/200mW hold power 1500Vrms 4000Vrms 2000Vrms 1000Vrms 4000Vrms 2500Vrms 4000Vrms 8/9.5mm 6.7/>8mm 6.1/6.1mm DC Coil +85°C; AC Coil +65°C RTI, RTII, RTIII +85°C RTII +85°C RTII THT/Quick connect Panel mount, PCB 52.3x34.6x30.8mm THT/Quick connect (#250) PCB 30.4x16x26.5mm PCB-THT PCB 30.4x16x26.5mm POTTER & BRUMFIELD T92 PCF PCFN SOLAR Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Accessories Link to datasheet 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. PAGE 11 Power PCB Relays up to 50A+ Relays, Contactors & Circuit Breakers EW60 Key Features 1 pole 60A, 1 form A (NO) contact Polarized bistable (latching) with 1 or 2 coils NEMA 410-2011, 16A, 277VAC, electronic ballast; 20A branch circuit 480A inrush, 2.1m sec Footprint 2) see footnote below 1) Applications Lighting control, bus actuator, power distribution, circuit protection, inverter Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 1 form A (1 NO) 440VAC 60A 15000VA AgSnO2 Visit TE.com for more information Coil Data Magnetic system Rated coil voltage Rated coil power Bistable 5 to 24VDC 1.5W/3W Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil 1500Vrms 4000Vrms ≥6/9mm Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +70°C RTI PCB PCB 36.8×17.2x30.4mm Accessories Link to datasheet EW60 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Power PCB Relays up to 50A+ Relays, Contactors & Circuit Breakers IHV Potter & Brumfield PRD Hermetically sealed - intrinsically safe Designed accordance to AIAG QS9000 No position sensitive RoHS compliance Contact ratings to 50A Magnetic blowout available for switching DC loads SPDT auxiliary switch available Class B insulation system PCB mount not applicable. Visit TE.com for more information PCB mount not applicable. Visit TE.com for more information DC charging, Solar inverter, Energy store station BMS, Electrical forklift, AGV, Rail transit Circuit protection and Safety in Industrial Machinery Industrial controls Lighting Contact arrangement 1 form X Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 450VDC / 750VDC 50A/100A/150A/200A/250A/350A Visit TE.com for more information 1 form A (1 NO) 1 form C (1 CO) 1 form X (NO-DM) 2 form A (2 NO) 2 form C (2 CO) 600VAC, 28/125VDC 50A 12000VA Ag, AgCdO 1A at 12VDC/VAC DC 12VDC, 24VDC or PWM Visit TE.com for more information DC, AC 6 to 110VDC/6 to 480VAC 2W/9.8VA 2000Vrms 2000Vrms 2000Vrms 2000Vrms Visit TE.com for more information >8mm Ambient temperature (max.) +85°C Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) RTV Screw Panel mount Visit TE.com for more information DC +80°C AC +45°C RT 0/open Screw/Quick connect Panel mount 85.7X63.8X63.5mm Key Features Applications Contact Data Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Accessories Dust cover Link to datasheet POTTER & BRUMFIELD PRD 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. PAGE 13 Force Guided Relays Relays, Contactors & Circuit Breakers SCHRACK SR2M SCHRACK SR4 D/M 2 pole relay with force guided contacts according to EN50205 Reinforced insulation between poles 4 pole relay with force guided contacts according to EN50205 Compact design, space efficient Safety modules Process technology Elevator and Escalator control Safety modules Process technology Elevator and Escalator control 1 form A + 1 from B (1 NO + 1 NC) 2 form C (2 CO) 250VAC 6A 1500VA AgNi 10mA at 5VDC 3 form A + 1 form B (3 NO + 1 NC) 2 form A + 2 form B (2 NO + 2 NC) 250VAC 8A 2000VA AgSnO2 10mA at 5VDC DC 5 to 110VDC 700mW DC 5 to 110VDC 800mW 1500Vrms 4000Vrms 3000Vrms 1500Vrms 4000Vrms 2500Vrms 8/8mm 10/10mm Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +70°C RTIII THT/Plug-in PCB/Socket 29x12.6x25.5mm +70°C RTIII THT PCB 40x13x16.5mm Accessories Sockets and relay clips Link to datasheet SCHRACK SR2M Key Features Footprint 2) see footnote below Applications Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS SCHRACK SR4 D/M 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Force Guided Relays Relays, Contactors & Circuit Breakers Key Features SCHRACK SR6 SCHRACK SRL7 4/6 pole relay with force guided contacts according to EN50205 Reinforced insulation between all contacts depending on version 7 pole relay with force guided contacts according to EN50205 Safety modules Process technology Elevator and escalator control Safety modules Process technology Elevator and escalator control 3 form A + 1 form B (3 NO + 1 NC) 2 form A + 2 form B (2 NO + 2 NC) 3 form A + 3 form B (3 NO + 3 NC) 4 form A + 2 form B (4 NO + 2 NC) 5 form A + 1 form B (5 NO + 1 NC) 250VAC 8A 2000VA AgSnO2 10mA at 5VDC 2 form B + 5 form A (2 NC + 5 NO) DC 5 to 110VDC 1200/800mW DC 5 to 110VDC 700mW 1500Vrms 4000Vrms 3000/4000Vrms 1000Vrms 2500/4000Vrms 2500/4000Vrms 5.5/5.5mm, 15/15mm ≥3/4mm and ≥5.5/5.5mm +70°C RTIII THT PCB 55x16.5x16.5mm +85°C RTII THT PCB 55.5x33.8x10.8mm SCHRACK SR6 SCHRACK SRL7 Footprint 2) see footnote below Applications Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 250VAC 6A 1500VA Ag alloy 10mA at 5VDC Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Accessories Link to datasheet 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. PAGE 15 Panel Plug-In Relays Relays, Contactors & Circuit Breakers SCHRACK SLIM INTERFACE SCHRACK INTERFACE SNR RELAY RT SCHRACK INTERFACE RELAY XT Strong coil pins for DIN-rail socket LED and protection circuit standard 4kV coil-contact, 6/8mm clearance/ creepage System width only 6.2mm Strengthened pins designed to plug into DIN-rail-sockets Cadmium-free contacts Complete interface solutions available Modular concept socket/relay/module Manual test tab, optionally lockable Mechanical and electrical indicator Reinforced insulation 4kV/8mm dielectric strength between coil and contact Interface technology Panel board Mechanical engineering Panel board Mechanical engineering Machine Industry Panel boards Mechanical engineering Contact arrangement 1 form C, (CO) Rated voltage Rated current Switching power / Max. break Contact material 250VAC 6A 1500VA AgSnO2, AgSnO2 Au plated 1 form C, (1 CO) 2 form C, (2 CO) 240VAC 8/16A 2000/4000VA AgSnO2, AgNi90/10 AgNi90/10 Au plated 1 form C, (1 CO) 2 form C, (2 CO) 240VAC 8/16A 2000/4000VA AgNi90/10 Min. recommended contact load 1) see footnote below 1) see footnote below 10mA at 12VDC DC 5 to 60VDC 170mW DC, AC 5 to 110VDC/24 to 230VAC 400mW/0.75VA DC, AC 12 to 110VDC/24 to 230VAC 400mW/0.75VA 1000Vrms 4000Vrms 1000Vrms 4000/5000Vrms 2500Vrms 1000Vrms 4000/5000Vrms 2500Vrms ≥6/8mm ≥8/8mm ≥8/8mm Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) Relay +85°C, in socket +55°C RTIII +70/+85°C RTII +70/+85°C RTII Plug-in Socket 28x5x15mm Plug-in Socket 29x13x15.7mm Plug-in Socket 29x13x26.7mm Accessories DIN rail sockets, jumper bars DIN rail and PCB sockets, DIN rail and PCB sockets, clips, marking tags, modules, jumper clips, marking tags, modules, bars jumper bars Link to datasheet SCHRACK SLIM INTERFACE SNR SCHRACK INTERFACE RELAY RT Key Features Footprint 2) see footnote below Applications Contact Data Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS SCHRACK INTERFACE RELAY XT 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Panel Plug-In Relays Relays, Contactors & Circuit Breakers Potter & Brumfield R10 Key Features Footprint 2) see footnote below Broad range of coil options provide sensitivity ranging from 25 to 750mW Various contacts switch from dry circuit to 7.5A Many mounting and termination options .210 (5.33) .400 .550 (10.16) (13.97) .450 (11.43) Applications Sensitive coil Low height 29/33mm Manual test tab, optionally lockable Mechanical indicator Optional LED, protection diode Potter & Brumfield K10 Mounting options include socket, PCB, top flange DC and AC coils LED versions available .740 .530 (18.80) .420 (13.46) (10.67) .320 (8.13) .110 (2.79) SCHRACK PT/ Potter & Brumfield KH .232 (5.89) .086 DIA. (2.18) .630 (16.00) HOLES .004 DIA. .056 +- .000 .10 1.42 +- .00 ( .394 .185 (10.01) (4.70) .285 (7.24) ) .559 (14.20) Coin changers Audio equipment Ultrasonic test equipment Machine industry Elevator industry Building management Industrial controls Motor controls Industrial timers Contact arrangement 1, 2, 3, 4, 6, 8 form C (CO) 2 form C (2 CO) Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load 115VAC, 115VDC 0.5/2/3/7.5A 862VA max. Ag, AgCdO, Ag w/ Au overlay Dry circuit to 300mA at 12VDC 2 form C (2 CO) 3 form C (3 CO) 4 form C (4 CO) 240VAC 1/2/5/6/10/12A 1500/2500/3000VA AgNi90/10, AgNi90/10 Au plated 1) Bifurcated contacts for dry circuit available on KH DC, AC 3 to 115VDC/6 to 115VAC 36mW to 1.6W/1.5VA DC, AC 6 to 220VDC/6 to 240VAC 750 to 900mW/1 to 1.2VA DC, AC 6 to 220VDC/6 to 240VAC 750 to 900mW/1 to 1.2VA 500/1000Vrms 1000Vrms 1000Vrms 1200Vrms 2500Vrms 2000/2500Vrms 1200/1000Vrms 2500/1500Vrms 2500/1500Vrms Visit TE.com for more information ≥4/4mm ≥3.1/3.1mm Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) +75°C RTI, RTIII +70°C RTII +70°C RTII Solder/plug-in and PCB Socket, panel mount and PCB 29.6x18.7x30.2mm THT, plug-in, Quick connect Socket, PCB 28x22.5x29/30/36mm Quick connect, solder, PCB Socket and bracket mount 28x22.5x29/34.9mm Accessories Solder/PCB sockets, clips, hold down strap, mounting strip DIN rail and PCB sockets, clips, marking tags, modules, jumper bars Screw, solder and PCB sockets and clips Link to datasheet POTTER & BRUMFIELD R10 Potter & Brumfield KHA SCHRACK PT POTTER & BRUMFIELD K10 Contact Data 120/240VAC 10/15A 1800/2500VA AgCdO, AgNi90/10 1) see footnote below Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. PAGE 17 Panel Plug-In Relays Relays, Contactors & Circuit Breakers Key Features Potter & Brumfield KRPA/MT Industry standard octal/undecal type termination for quick installation DC and AC coils Mechanical indicator, indicator lamp and push-to-test options SCHRACK RM2/3/7 Wide selection of termination and mounting styles PC terminals available Push to test button and indicator lamps Class B coil insulation Potter & Brumfield KUP/ KUMP/KUIP Wide selection of termination and mounting styles Broad range of contact forms PC terminals available Push to test button and indicator lamps Class B coil insulation Footprint .206 (5.23) .076 DIA. TYP. (1.93) 2) see footnote below .328 (8.33) .626 (15.90) PCB mount not applicable. Visit TE.com for more information .340 (8.64) .170 (4.32) .510 (12.95) 1.020 (25.91) Mechanical engineering Elevator control, Plant control Baggage handling Elevator control Power supplies HVAC Pump motor controls Hospital beds Contact arrangement 1 form C (1 CO) (KRPA) 2 form C (2 CO) 3 form C (3 CO) 2 form C (2 CO) 3 form C (3 CO) Rated voltage Rated current Switching power / Max. break Contact material 240VAC 4/10A 500/2400/2500VA AgCdO, AgNi90/10, AgNi90/10 Au plated 1) see footnote below 400VAC 10/16A 3800/6000VA AgCdO, AgNi90/10 in preparation 1, 2, 3, 4 form C (CO) 1, 2, 3 form A (NO) 2, 3 form B (NC) 1 form X (NO-DM) 1 form Y (NC-DB) 1 from Z (CO-DM/DB) 240VAC 10/15A 2400/4155VA Ag, AgCdO, AgSnOInO 100mA at 12VDC 100mA at 12VDC(Ag) 300mA at 12VDC (AgCdO, AnSnOInO) DC, AC 6 to 220VDC/6 to 240VAC 760mW to 1.3W/0.74 to 2.3VA DC, AC 6 to 220VDC/6 to 400VAC 1.2 to 1.8W/2 to 2.8VA DC, AC 5 to 110VDC/6 to 240VAC 1.2 to 1.8W/2 to 2.7VA 1000/1500Vrms 1000/2500Vrms 1000/2500Vrms 1500Vrms 2500Vrms 2500Vrms 1200Vrms 2200/3750Vrms 2200Vrms ≥2.8/4mm ≥4/14.9mm Visit TE.com for more information DC +60/+70°C AC +50/+55°C RTI +50/+70°C RTI DC +50/+70/+95°C AC +45/+55/+70°C RTI Plug-in Socket THT, Plug-in, solder, Quick connect Socket, PCB, bracket, flange mount and DIN-snap-on 38.5x35.5x48.5mm THT, Plug-in, solder, Quick connect Socket, PCB, bracket, flange, stud and tapped core 38.9x35.7x48.4mm Applications Contact Data Min. recommended contact load Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) 35.7x35.7x50.8/57mm Accessories DIN rail and PCB sockets, clips, marking tags, modules DIN rail and PCB sockets, clips DIN rail, panel and PCB sockets, clips Link to datasheet POTTER & BRUMFIELD KRPA SCHRACK MT SCHRACK RM2/3/7 Potter & Brumfield KUIP KUGP KUM KUMP KUP 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Panel Plug-In Relays Relays, Contactors & Circuit Breakers Key Features SCHRACK RM8/C/D Potter & Brumfield KUHP SCHRACK RM5/6/B 3MM Power relay with push-on and solder terminals Various mounting options Indicator lamps and mechanical indicator Optional push to test button Power relay with push-on and solder terminals Various mounting options Designed to meet VDE space requirements Class B coil insulation 3mm contact gap DC or AC coil Push-to-test button Plug-in version, PCB terminals or chassis or DIN-rail mount Footprint .875 (22.23) 2) see footnote below .243 (6.17) PCB mount not applicable. Visit TE.com for more information .240 (6.10) .076 DIA. TYP. (1.93) Applications .397 (10.08) Cleaning equipment Heating equipment Cooling equipment Baggage handling motors Industrial pumps Commercial ovens Power supplies Pump control 1 form C (1 CO) 2 form C (2 CO) 1 form Z contact (1 NO + 1 NC) 1 form X contact (1 NO) 400VAC 25/30/32A 6000/7500VA AgCdO, AgNi90/10 100mA at 12VDC 1 form C (1 CO) 2 form C (2 CO) 2 form A (2 NO) 3 form A (3NO) 240VAC, 50/60Hz; 28VDC 20/30A 4800/7200VA AgCdO, AgSnOInO 300mA at 12VDC 240/400VAC 10/16A 3800/6000VA AgCdO, AgNi90/10 in preparation 100mA at 12VDC DC, AC 6 to 220VDC/6 to 400VAC 1.2W/2.7VA DC, AC DC, AC 6 to 110VDC 50/60Hz. 6 to 277VAC 6 to 220VDC/6 to 400VAC 1.2W/2.7VA 1.2W/2.7VA 1500/2000Vrms 2500Vrms 4000Vrms 1200Vrms 3750Vrms 3750Vrms 2500Vrms 2500Vrms 2500Vrms ≥4/14.9mm Visit TE.com for more information ≥4/14.9mm DC +60/+65°C AC +40°C RTI DC +45°C AC +75°C RTI, RT0 +50/+60°C Solder/PCB THT/Quick connect Bracket and top flange panel mount 38.9x35.7x48.4mm Plug-in, solder, Quick connect, PCB THT Dimensions (lwh) Solder/Quick connect Bracket, top flange panel mount and DIN snap-on 38.5x35.5x48.5mm Accessories No sockets No sockets DIN rail and PCB sockets, clips Link to datasheet SCHRACK RM8C/D SCHRACK RM 8 POTTER & BRUMFIELD KUHP SCHRACK RM5/6/B 3MM Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. RTI Socket, PCB, bracket, flange mount and DIN-snap-on 38.5x35.5x48.5mm 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. PAGE 19 Panel Plug-In Relays Relays, Contactors & Circuit Breakers Key Features Footprint Potter & Brumfield KUGP Potter & Brumfield KUL Potter & Brumfield KUEP 3mm contact gap DC or AC coil Plug-in version, PCB terminals or chassis mount Magnetic latching Single and dual coils Panel mounting 10A relay with various contact arrangements Magnetic blowout for 150VDC load switching Indicator lamp option .076 DIA. TYP. (1.93) .206 (5.23) .076 DIA. TYP. (1.93) 2) see footnote below .328 (8.33) .626 (15.90) .437 (11.10) 2 5 3 6 7 8 9 A 2.156 MAX. (54.76) .875 (22.23) Applications 1 4 .281 REF. (7.14) .206 (5.23) .328 (8.33) .626 (15.90) 1.406 MAX. (35.71) B 1.531 MAX. (38.89) .875 (22.23) Voltage control units Alarm systems Machine tools Battery chargers DC load switvhing in industrial controls 1 form C (1 CO) 2 form A (2 NO) 2 form C (2 CO) 3 form C (3 CO) 240/400VAC 10A 2400VA Ag, AgCdO 100mA at 12VDC (Ag) 300mA at 12VDC (AgCdO) 1 form C (1 CO) 2 form C (2 CO) 3 form C (3 CO) 1 form X (NO-DM) 2 form A (2 NO) 2 form C (2 CO) 28/240VAC 10A 150VDC/240VAC 10A 1500W/2400VA AgCdO, AgSnOInO 300mA at 12VDC DC, AC 6-110VDC/6-240VAC 1.8W/2.7VA DC, AC 12 to 48VDC/24 to 120/240VAC 1.6W dual coil/1.2W single coil DC, AC 5 to 110VDC/6 to 240VAC 1.2W to 1.8W/2 to 2.7VA 3500Vrms 2200Vrms 2200Vrms 500Vrms 1500Vrms 1500Vrms 1200Vrms 2200Vrms 2200Vrms >8mm Visit TE.com for more information Visit TE.com for more information DC +75°C AC +70°C RTI DC +70°C AC +50/+70°C RTI AC +55/+70°C DC +50/+70°C RTI Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Contact material Min. recommended contact load Ag, AgCdO 100mA at 12VDC (Ag) 300mA at 12VDC (AgCdO) Coil Data Magnetic system Rated coil voltage Rated coil power Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Quick connect, solder and PCB Mounting Dimensions (lwh) THT, Plug-in, solder, Quick connect, .187 Quick connect, solder PCB Socket, PCB, bracket, flange mount Socket, bracket 38.9x35.7x48.4mm 38.9x35.7x54.8mm Accessories DIN rail and PCB sockets, clips Screw, solder, PCB and Quick connect sockets and clips DIN rail, track mount, chassis mount, and snap-in sockets, clips Link to datasheet POTTER & BRUMFIELD KUGP POTTER & BRUMFIELD KUL POTTER & BRUMFIELD KUEP 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. INDUSTRIAL /// QUICK REFERENCE GUIDE INDUSTRIAL RELAYS Socket, PCB, bracket and top flange mount 38.9x35.7x48.4mm 2) F  ootprint images are representative. For a complete selection, refer to the TE data sheet via the link above. Panel Plug-In Relays Relays, Contactors & Circuit Breakers Key Features ACCESSORIES SETS DIN rail and PCB sockets Screw and screwless fingersafe terminals Retaining and ejection clips Marking tags, jumper bars, jumper links LED and protection modules Relay package consisting of relay, DIN rail socket, plastic retaining clip, marking tag and module 1 form C (1 CO) 2 form C (2 CO) 3 form C (3 CO) 4 form C (4 CO) 240/250VAC 6 to 16A 1 form C (1 CO) 2 form C (2 CO) 3 form C (3 CO) 4 form C (4 CO) 240/250VAC 6 to 16A 1500 to 4000VA Applications Contact Data Contact arrangement Rated voltage Rated current Switching power / Max. break Min. recommended contact load 1) see footnote below Coil Data Magnetic system Rated coil voltage Rated coil power DC, AC 6 to 220VDC/6 to 230VAC 170 to 700mW/0.4 to 1VA Dielectric Strength Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil Other Data Ambient temperature (max.) Category of environmental protection IEC61810 Terminal type Mounting Dimensions (lwh) IP20 Screw, screwless, plate mount, PCB Screw, screwless Accessories PCB, panel mount and DIN rail DIN, panel mount Link to datasheet ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES RELAY PACKAGE RT RELAY PACKAGE PT RELAY PACKAGE SNR ACCESSORIES MULTIMODE RELAY MT SLIM INTERFACE RELAY SNR INDUSTRIAL POWER RELAY RT MINIATURE RELAY PT INTERFACE PLUG-IN RELAY XT 1) Recommended minimum load indication for contact material: AU and gold plated: 1mA at 6VDC; AgNi0.15 and AgNi90/10: 10mA at 12VDC: AgCdO and AgSnO2: 100mA at 12VDC. Please contact technical support for detailed technical data. PAGE 21 Signal Relays Relays, Contactors & Circuit Breakers Axicom IM Axicom IMB Axicom IMC Telecommunication, access and transmission equipment Thermostat controls, fire and security equipment Measurement and test equipment, Industrial controls, medical equipment Telecommunication, access and transmission equipment Thermostat controls, fire and security equipment Measurement and test equipment, Industrial controls, medical equipment Telecommunication, access and transmission equipment Thermostat controls, fire and security equipment Measurement and test equipment, Industrial controls, medical equipment 2 form C, 2 CO Single contact + Bifurcated contacts 250VAC/220VDC 2/5A 60W/62.5VA 100µV/1µA
9-1423674-1 价格&库存

很抱歉,暂时无法提供与“9-1423674-1”相匹配的价格&库存,您可以联系我们找货

免费人工找货