SPECIFICATION CONTROL DRAWING
55PC0811
WIRE, RADIATION-CROSSLINKED, MODIFIED, ETFE-INSULATED,
GENERAL PURPOSE, NORMAL AIRFRAME
TITLE
Date
Revision
07-09-04
F
This specification sheet forms a part of the latest issue of Raychem Specifiction 55PC.
CONDUCTOR - TIN-COATED COPPER
INSULATION - RADIATION-CROSSLINKED,
MODIFIED ETFE
CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
55PC0811-26-*
55PC0811-24-*
55PC0811-22-*
55PC0811-20-*
55PC0811-18-*
55PC0811-16-*
55PC0811-14-*
55PC0811-12-*
55PC0811-10-*
55PC0811- 8-*
55PC0811- 6-*
55PC0811- 4-*
55PC0811- 2-*
55PC0811- 0-*
55PC0811- 00-*
26
24
22
20
18
16
14
12
10
8
6
4
2
0
00
CONDUCTOR
STRANDING
(number x AWG)
19
19
19
19
19
19
19
37
37
133
133
133
665
1045
1330
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
38
36
34
32
30
29
27
28
26
29
27
25
30
30
30
CONDUCTOR DIAMETER
( in.)
LOWER
SPEC
LIMIT
TARGET
VALUE
UPPER
SPEC
LIMIT
.0175
.0225
.0285
.0365
.0452
.0514
.0644
.0825
.1050
.158
.198
.250
.320
.395
.440
.0183
.0233
.0293
.0375
.0464
.0527
.0659
.0845
.1070
.163
.205
.260
.330
.415
.462
.0191
.0241
.0301
.0385
.0476
.0538
.0674
.0865
.1090
.169
.212
.268
.340
.425
.475
FINISHED WIRE
DIAMETER
MAXIMUM
( in.)
RESISTANCE
AT 20°C
LOWER SPEC
TARGET UPPER SPEC
(ohms/1000 ft.)
LIMIT
VALUE
LIMIT
41.3
26.2
16.2
9.88
6.23
4.81
3.06
2.02
1.26
.701
.445
.280
.183
.116
.091
.0366
.0416
.0476
.0561
.0659
.0737
.0896
.1076
.1290
.188
.233
.300
.370
.449
.505
.0385
.0435
.0495
.0580
.0680
.0760
.0920
.1105
.1330
.196
.242
.311
.383
.466
.525
.0404
.0454
.0514
.0599
.0701
.0783
.0944
.1134
.1370
.203
.251
.322
.397
.483
.545
WEIGHT
( lbs/1000 ft. )
TARGET
VALUE
UPPER SPEC
LIMIT
1.55
2.18
3.12
4.64
6.94
8.80
13.50
20.45
31.73
56.8
89.7
146.
227.
343.
450.
1.70
2.34
3.30
4.85
7.27
9.17
13.99
21.08
32.78
59.9
94.7
154.
240.
366.
481.
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
COLOR: White preferred
CROSSLINK VERIFICATION: 300 ± 3°C for 1 hour
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
SHRINKAGE: 230 ± 3°C for 1 hour, 0.125 in. (maximum) in 12 in.
INSULATION ELONGATION AND TENSILE STRENGTH:
VOLTAGE WITHSTAND TEST (Post Environmental):
Total Insulation,
2500 volts (rms)
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
PART NUMBER:
INSULATION FLAWS:
The "*" in the part numbers above shall be replaced by
Spark Test, 3.0 kV (rms)
color code designators.
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS: .010 in. (nominal) total insulation 1/ Example: AWG 22, white: 55PC0811-22-9
AWG 22, white with black stripe: 55PC0811-22-90
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 1
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
R Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297