55A9002
Issue 5
26th November 2008
Specification Control Drawing
Page 1 of 2
Page 2 is for internal use only
WIRE, ELECTRIC, RADIATION CROSSLINKED EXTRUDED, MODIFIED
ETFE INSULATED, SILVER PLATED COPPER
FOR WRAPPED SOLDERLESS CONNECTIONS
The complete requirements for procuring the wire described herein shall consist of this document.
Conductor Solid
Silver Plated Copper
Insulation Radiation Crosslinked
Extruded Modified ETFE
Conductor
Wire
Outside
Size
Diameter
(AWG)
(mm)
Nom.
55A9002-30-*
30
0.25
55A9002-26-*
26
0.40
55A9002-24-*
24
0.52
Part
Description
Resistance
@ 20°C
(ohms/ km)
Max.
387
152
92.8
FINISHED WIRE
Diameter
(mm)
Min.
0.46
0.64
0.74
Nominal
0.50
0.67
0.78
Max.
0.53
0.71
0.81
Weight
(kg/ km)
Nom.
0.73
1.63
2.38
COLOUR CODE:
The '*' in the part number shall be replaced by a standard colour code
designator in accordance with Mil Std 681.
PERFORMANCE
REQUIREMENTS:
To be tested to and meet the requirements of the issue in effect of
Raychem specification WSD 1244.
APPROVAL:
Electronic sign off - no signatures will appear.
Tyco Electronics
UK Ltd
Faraday Road
Dorcan
SWINDON
SN3 5HH
Tel: (01793) 528171
Telex: 449409
Registration Number: 550926
London, England
This drawing and the information set forth hereon are the property of Tyco
Electronics UK Ltd, and are to be held in trust and confidence. Publication,
duplication, disclosure or use for any purpose not expressly authorised in writing
by Tyco Electronics UK Ltd is prohibited.
Insulation
Removal
Force (grms)
Min.
Max.
150
500
150
1000
150
1000
This specification sheet takes precedence over documents referenced
herein. As Tyco Electronics UK Ltd. reserve the right to make changes in
construction without notice please contact Tyco Electronics UK Ltd to
ensure that this document is the latest issue.
©2008 Tyco Electronics Corporation. All International Rights Reserved.
很抱歉,暂时无法提供与“99M0111-20-9”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+983.39946
- 50+974.45398