SPECIFICATION CONTROL DRAWING
Title
55A7526
Date
TWO CONDUCTOR CABLE, TIN-COATED COPPER CONDUCTOR,
07-15-04
UNSHIELDED, UNJACKETED
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
Revision
COMPONENT WIRES - 55A6768
PART NUMBER
1/
55A7526-18-*
CABLE CONSTRUCTION DETAILS
OUTSIDE DIAMETER
CONDUCTOR
(inches)
SIZE
(AWG)
NOMINAL
MAXIMUM
18
.140
.146
MAXIMUM
WEIGHT
(lbs/1000 ft)
14.7
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
INSULATION FLAWS:
Spark Test, 5.7 kV (rms) at 3kHz
Impulse Dielectric Test, 8.0 kV (peak)
The “*” in the part numbers above shall be replaced by
color code designators with a slash separating
component wire colors:
1/ Example: AWG 18, black and white component wires:
55A7526-18-0/9
NOTE: Nominal values are for information only
Nominal values are not requirements.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: "901/902..." MAY BE REPLACED BY "Axxx".) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
Page 1 of 1
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297