SCD
SPECIFICATION CONTROL DRAWING
55/0312
Date
Revision
WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED,
6-6-17
ULTRA LIGHTWEIGHT, OUTER SPACE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 55/.
Title
CONDUCTOR - SILVER-COATED COPPER
K
INSULATION - RADIATION-CROSSLINKED,
MODIFIED ETFE
TABLE I. CONSTRUCTION DETAILS
PART NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
DIAMETER OF
STRANDED
CONDUCTOR
(inch)
MINIMUM
MAXIMUM
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20°C
(ohms/1000 ft.)
MAXIMUM
WEIGHT
(lbs/1000 ft.)
DIAMETER
(inch)
55/0312-30-*
30
7 x 38
.0110
.0120
100.7
.0195 ± .0015
55/0312-28-*
28
7 x 36
.0140
.0150
63.8
.0225 ± .0015
.52
.76
55/0312-26-*
26
19 x 38
.0175
.0191
38.4
.0274 ± .0017
1.22
55/0312-24-*
24
19 x 36
.0225
.0241
24.3
.0322 ± .0017
1.79
55/0312-22-*
22
19 x 34
.0285
.0301
15.1
.0390 ± .0017
2.70
55/0312-20-*
20
19 x 32
.0365
.0385
9.19
.0495 ± .0017
4.27
55/0312-18-*
18
19 x 30
.0452
.0476
5.79
.0590 ± .0017
6.56
55/0312-16-*
16
19 x 29
.0514
.0538
4.52
.0665 ± .0019
8.33
55/0312-14-*
14
19 x 27
.0644
.0674
2.88
.0810 ± .0021
12.81
55/0312-12-*
12
37 x 28
.0825
.0865
1.90
.1000 ± .0026
19.71
55/0312-10-*
10
37 x 26
.1050
.1090
1.19
.1260 ± .0040
31.70
TABLE II. PERFORMANCE DETAILS
CROSSLINKED VERIFICATION - BEND TESTING
PART NUMBER
1/
MANDREL DIAMETER
(inch) (± 3%)
WEIGHT
(lb) (± 3%)
55/0312-30-*
.250
.063
55/0312-28-*
.250
.063
55/0312-26-*
.375
.063
55/0312-24-*
.375
.125
55/0312-22-*
.500
.188
55/0312-20-*
.500
.250
55/0312-18-*
.500
.250
55/0312-16-*
.750
.375
55/0312-14-*
1.00
.500
55/0312-12-*
1.50
.750
55/0312-10-*
2.00
.750
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
TE Connectivity also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Raychem, TE Connectivity, and TE Connectivity (logo) are trademarks.
Page 1 of 2
DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-522-6752
Fax: 1-650-361-6297
© 2006-2017 TE Connectivity Ltd. family of companies. All Rights Reserved.
Page
SPECIFICATION CONTROL DRAWING
2 of 2
Revision
SCD
K
55/0312
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
COLOR: White preferred
CONCENTRICITY: 80% (minimum)
CROSSLINKED VERIFICATION: 300 ± 3°C for 1 hour
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
INSULATION ELONGATION: 50% (minimum)
INSULATION FLAWS:
Spark Test, 1.5 kV (rms) (30-24 AWG)
3.0 kV (rms) (22-10 AWG)
Impulse Dielectric Test, 6.0 kV (peak)
INSULATION THICKNESS: .004 in. (nominal)
RADIATION RESISTANCE: 500 megarads
SHRINKAGE: 230 ± 3°C for 1 hour, 0.125 in. (maximum) in 12 inches
VACUUM STABILITY:
Total Mass Loss (TML), 1.00% (maximum)
Volatile Condensable Material (VCM): 0.10% (maximum)
VOLTAGE WITHSTAND (Post Environmental): 1500 volts (rms), 60 Hz, 5 minutes
1/ PART NUMBER:
The "*" in the part numbers in Tables I and II shall be replaced by a color code designator.
Example: AWG 20, white: 55/0312-20-9
AWG 20, white with a black stripe: 55/0312-20-90
1/ See footer section on page 1