CR1702-000

CR1702-000

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
CR1702-000 数据手册
0026A0664 SPECIFICATION CONTROL DRAWING CHEMINAX 100 OHMS, AWG 26, 19 STRANDS OF AWG 38, TWIN CONDUCTOR CABLE, OUTER SPACE Date: 12-13-06 Revision: D THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE DESIGNATED. CONDUCTOR AWG 26, 19 Strands of AWG 38, Silver-Coated High Strength Copper Alloy .020 .060 DIELECTRIC Radiation-crosslinked Modified ETFE (Dual Extruded) Color - Light Blue/White SHIELD AWG 38 Tin-Coated Copper .137 JACKET Radiation-Crosslinked Modified ETFE .153 ELECTRICAL CHARACTERISTICS CHARACTERISTIC IMPEDANCE 100 ± 10 ohms, Method D at 1 MHz CAPACITANCE - MUTUAL 16.0 pF/ft. (nominal) ADDITIONAL REQUIREMENTS COMPONENT WIRE PRIOR TO CABLING (Test Procedures per SAE AS22759) CROSSLINK PROOF 300 ± 3°C for 1 hour, .750 inch mandrel, .625 lb., 2.5 kV dielectric test -65 ± 2°C for 4 hours, .500 inch mandrel, .500 lb., 2.5 kV dielectric test 200 ± 3°C for 1 hours, .125 inch (maximum) in 12 inches 5000 megohms for 1000 ft. (minimum) LOW TEMPERATURE COLD BEND SHRINKAGE INSULATION RESISTANCE INSULATION (DIELECTRIC) (total insulation) TENSILE STRENGTH ELONGATION INSULATION FLAWS SPARK TEST IMPULSE TEST 5000 lbf/in² (minimum) 50% (minimum) 3.0 kV (rms) 8.0 kV (peak) FINISHED CABLE (Test Procedures per NEMA WC27500) BLOCKING LOW TEMPERATURE COLD BEND CROSSLINKED VERIFICATION FLAMMABILITY (Method B of Spec 1200) JACKET FLAWS SPARK TEST IMPULSE TEST JACKET TENSILE STRENGTH ELONGATION JACKET THICKNESS SHIELD COVERAGE VOLTAGE WITHSTAND (DIELECTRIC) WEIGHT 200°C for 6 hours -55 ± 5°C for 4 hours, 6.0 inch mandrel 300 ± 5°C for 6 hours, 6.0 inch mandrel 3 seconds (maximum); 3.0 inches (maximum), no flaming of facial tissue 1.0 kV (rms) 6.0 kV (peak) 5000 lbf/in² (minimum) 50% (minimum) .005 (minimum) .008 (nominal) 90% (minimum) 1500 volts (rms) 14.6 lbs/1000 ft. (nominal) OUTER SPACE REQUIREMENTS Outer jacket color will be white (designated by a "-9" appended to the part number, e.g. 0026A0664-9) unless otherwise specified. Designate outer jacket color with a dash number in accordance with MIL-STD-681. Other codes and suffixes may be added to the part number, as necessary, to capture any additional requirements imposed by the purchase order. RADIATION RESISTANCE VACUUM STABILITY TOTAL MASS LOSS (TML) VOLATILE CONDENSABLE MATERIAL (VCM) WEIGHT LOSS: (Test per Spec 55/) 500 megarads/4.50 inch mandrel 1.0% (maximum) 0.1% (maximum) 0.45% (maximum) Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. R Wire & Cable 501 Oakside Avenue Redwood City, California 94063-3800 1-800-227-8816 Fax: 1-650-361-6297 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. © 2006 Tyco Electronics Corporation. All rights reserved.
CR1702-000 价格&库存

很抱歉,暂时无法提供与“CR1702-000”相匹配的价格&库存,您可以联系我们找货

免费人工找货