SPECIFICATION CONTROL DRAWING
44A0311
WIRE, RADIATION-CROSSLINKED, POLYALKENE-INSULATED,
LIGHTWEIGHT, GENERAL PURPOSE, 2500 VOLT
28MAR11
This specification sheet forms a part of the latest issue of Raychem Specification 44.
I
L1
PRIMARY INSULATION - RADIATION-CROSSLINKED,
EXTRUDED POLYALKENE
CONDUCTOR- TIN-COATED COPPER
JACKET- RADIATION-CROSSLINKED,
MODIFIED PVDF
Thickness:
AWG 26- 4, .005 ± .001 in.
AWG 2 -00, .010 ± .002 in.
TABLE I. CONSTRUCTION DETAILS
PART NUMBER
jJ
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
DIAMETER OF
STRANDED
CONDUCTOR
(in.)
MINIMUM
MAXIMUM
FINISHED WIRE
MAXIMUM
RESISTANCE
AT 20"C
(ohms/1 000 ft)
DIAMETER
(in.)
MAXIMUM
WEIGHT
(lbs/1 000 ft.)
44A0311-26-•
26
19 X 38
.018
.020
41.3
.053 ± .002
2.1
44A0311-24-•
24
19 X 36
.023
.025
26.2
.057 ± .002
3.0
44A0311-22-•
22
19 X 34
.029
.033
16.2
.069 ± .003
4.3
44A0311-2o-·
20
19 X 32
.037
.041
9.88
.078 ± .003
6.1
44A0311-18-•
18
19 X 30
.046
.051
6.23
.088 ± .003
8.7
44A0311-16-•
16
19 X 29
.052
.058
4.81
.097 ± .004
10.9
44A0311-14-•
14
19 X 27
.065
.073
3.06
.115 ± .004
16.2
44A0311-12-•
12
37 X 28
.084
.090
2.02
.131 ± .004
24.2
44A0311-1o-·
10
37 X 26
.106
.114
1.26
.161 ± .005
36.5
44A0311-8-·
8
133 X 29
.158
.173
.701
.219 ± .006
44A0311-6-•
6
133 X 27
.198
.217
.445
.269 ± .007
65.0
103.
44A0311 -4- •
4
133 X 25
.250
.274
.280
.325 ± .008
158 .
44A0311 2-·
2
665 X 30
.320
.340
.183
.404 ± .012
252.
44A0311 -0- •
0
1045x30
.405
.425
.116
.494 ± .016
380 .
44A0311-oo-·
00
1330x30
.450
.475
.092
.545 ± .016
459 .
TE Connect1v1ty
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND
COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681
OTHER CODES AND SUFFIXES MAY BE ADDED
TE Connectivity TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER
The TE logo, TE Connect1v1ty
Page 1 of3
and Raychem are trademarks.
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID
CTE
TE
Connecti•;ity
TE Connectivity Wire & Cable
501 OaksideAvenue
Redwoxi City, CA94003-3800
Phone 1-800-227-8816
Fax: 1-650-361-6297
~TE
TE Connectivity
SCD Number
SPECIFICATION CONTROL DRAWING
44A0311
Page 2 of 3
TABLE II. PERFORMANCE DETAILS
BEND TESTING
PART NUMBER
jJ
MANDREL DIAMETER
WEIGHT
(inch)(± 3%)
(lb) (± 3%)
IMMERSION
LIFE CYCLE AND
ACCELERATED AGING
COLD
BEND
WRAP
IMMERSION
LIFE CYCLE AND
ACCELERATED AGING
COLD
BEND
44A0311-26-•
.500
1.00
.250
.625
3.00
44A0311-24-•
.500
1.00
.250
.625
3.00
44A0311-22-•
.750
1.00
.250
.750
1.00
.250
2.50
4.00
1.50
.375
2.50
4.00
44A0311-2o-·
2.00
3.00
44A0311-18-•
1.00
44A0311-16-•
1.00
1.50
.375
2.50
5.00
44A0311-14-•
1.50
2.00
.500
2.50
5.00
44A0311-12-•
2.00
2.00
.500
3.00
5.00
44A0311-1o-·
3.00
3.00
.750
3.00
5.00
44A0311 -8- •
3.00
4.00
.750
6.00
44A0311 -6- •
4.00
5.00
44A0311 -4- •
5.00
44A0311-2-•
6.00
44A0311 -0- •
8.00
44A0311-oo-·
9.00
6.00
1.00
6.00
10.0
6.00
1.25
6.00
10.0
8.00
3.00
6.00
15.0
10.0
4.00
7.00
15.0
12.0
5.00
7.00
15.0
~TE
TE Connectivity
SCD Number
SPECIFICATION CONTROL DRAWING
Page 3 of 3
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150"C
Maximum continuous conductor temperature
VOLTAGE RATING: 2500 volts (rms) at sea level
ACCELERATED AGING: 300 ± 2"C for 6 hours
Identification legibility, 225 ± 2oC for 6 hours
BLOCKING: 150 ± 2"C for 24 hours
COLOR: White preferred
FLAMMABILITY: 30 seconds (maximum); 3 in, (maximum); no flaming of facial tissue
HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft (minimum)
IDENTIFICATION AND COLOR STRIPING DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown,
INSULATION ELONGATION AND TENSILE STRENGTH:
1,5 inch jaw separation, 2,0 inch/minute crosshead speed
Primary Insu Iat ion,
Elongation, 150% (minimum)
Tensile Strength, 2500 lbf/in 2 (minimum), AWG 26-12
2000 lbf/in 2 (minimum), AWG 10-00
INSULATION FLAWS:
Primary Insu Iat ion,
Spark Test, 5,0 kV (rms)
Impulse Dielectric Test, 6,0 kV (peak)
Finished Wire,
Spark Test, 8,0 kV (rms) at 3kHz
Impulse Dielectric Test, 13,0 kV (peak)
INSULATION RESISTANCE: 5000 megohms for 1000 ft (minimum)
LIFE CYCLE: 200 ± 2"C for 168 hours
LOW TEMPERATURE-COLD BEND: -65 ± 2"C for 4 hours
SHRINKAGE: 300 ± 2°C, 0,125 in, (maximum) in 12 in,, AWG 26-12
300 ± 2°C, 0,250 in, (maximum) in 12 in,, AWG 10-00
SMOKE: 200 ± 2"C, No visible smoke,
SURFACE RESISTANCE: 500 megohms-in, (minimum), both readings
THERMAL SHOCK RESISTANCE: 150 ± 2°C, 0,060 in, (maximum)
VOLTAGE WITHSTAND (Post Environmental): 5000 volts (rms), 60 Hz, 5 minutes
WICKING: 2,25 in, (maximum)
PART NUMBER: The"*" in the part numbers on pages 1 and 2 shall be replaced by color code
designators,
1J Example: AWG 20, white: 44A0311-20-9
AWG 20, white with black stripe: 44A0311-20-90
1/ See footer section on page 1
44A0311