TECHNICAL DATA SHEET
400R SIGNAL WIRE & CABLE
Document number: TTDSIssue: 1
Date: January 2016
APPLICATION/USE:
400R SERIES PRODUCT
FAMILY:
Rail approved limited fire hazard, light weight wire and cable for
signal, and low voltage applications. The Insulation is a dual wall
combination of TE Connectivity formulated polymer blends.
Developed to meet Rail specification requirements such as
NFPA 130, whilst maintaining the desirable properties of small
size, lightweight, flexible and easy to handle and install.
400R*1**
Rail approved 600V range of Wires & Cables
Page 1 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
Document number: TTDSIssue: 1
Date: January 2016
400R SIGNAL WIRE & CABLE
PART DESCRIPTION
400 R 0 1 1 1 – 18 – 0
Jacket Colour
Conductor Size
(26AWG-000AWG)
Conductor Type
(1 = Tin plated copper)
Number of Conductors
( 1 to 9)
Class of Wire
(1 = 600V)
(3 = 2500V)
Constructions
0 = Just primary wire, 1 = Round braid, screened and Jacketed, 4 = Jacketed, no screen
Type R - Rail
Base Wire
SINGLE CORE 400R0111-xx
Page 2 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
400R SIGNAL WIRE & CABLE
Document number: TTDSIssue: 1
Date: January 2016
SINGLE CORE 400R0111-xx (600V)
Part Number
400R0111-26-*
400R0111-24-*
400R0111-22-*
400R0111-20-*
400R0111-18-*
400R0111-16-*
400R0111-14-*
400R0111-12-*
400R0111-10-*
Wire
Size
Conductor
Stranding
Diameter of stranded
conductor
AWG
26
24
22
20
18
16
14
12
10
No. x AWG
19 x 38
19 x 36
19 x 34
19 x 32
19 x 30
19 x 29
19 x 27
37 x 28
37 x 26
inch min
0.018
0.023
0.029
0.037
0.046
0.052
0.065
0.084
0.106
inch max
0.021
0.026
0.033
0.041
0.051
0.058
0.073
0.090
0.114
Max
Resistance
at 20°C
Ω/1000ft
41.3
26.2
16.2
9.88
6.23
4.81
3.06
2.02
1.26
Diameter
inch
min
max
0.032
0.036
0.038
0.042
0.045
0.049
0.053
0.057
0.063
0.067
0.069
0.075
0.085
0.093
0.104
0.112
0.125
0.133
Maximum
weight
lbs/1000ft
1.4
2.0
3.0
4.5
6.8
8.6
13.2
20.2
31.1
Page 3 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
400R SIGNAL WIRE & CABLE
Document number: TTDSIssue: 1
Date: January 2016
TWO CORE 400R1121-xx (600v)
Construction Details
Part Number
Wire
Size
Shield size
AWG
26
24
22
20
18
16
14
12
10
AWG
38
36
36
36
36
36
36
36
36
Jacket thickness
Diameter
Maximum
weight
inch
400R1121-26-*
400R1121-24-*
400R1121-22-*
400R1121-20-*
400R1121-18-*
400R1121-16-*
400R1121-14-*
400R1121-12-*
400R1121-10-*
inch min
0.006
0.006
0.006
0.006
0.007
0.007
0.007
0.007
0.008
inch nom
0.008
0.008
0.008
0.008
0.009
0.009
0.009
0.009
0.010
nom
0.102
0.118
0.132
0.148
0.170
0.184
0.218
0.256
0.299
max
0.107
0.123
0.137
0.153
0.175
0.189
0.225
0.265
0.314
lbs/1000ft
8.1
11.3
14.5
18.8
25.7
30.2
43.2
61.5
86.3
Page 4 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
400R SIGNAL WIRE & CABLE
Document number: TTDSIssue: 1
Date: January 2016
THREE CORE 400R1131-xx (600v)
Construction Details
Part Number
Wire
Size
Shield size
AWG
26
24
22
20
18
16
14
12
AWG
36
36
36
36
36
36
36
36
Jacket thickness
Diameter
Maximum
weight
inch
400R1131-26-*
400R1131-24-*
400R1131-22-*
400R1131-20-*
400R1131-18-*
400R1131-16-*
400R1131-14-*
400R1131-12-*
inch min
0.006
0.006
0.006
0.006
0.007
0.007
0.007
0.008
inch nom
0.008
0.008
0.008
0.008
0.009
0.009
0.009
0.010
nom
0.111
0.124
0.140
0.157
0.180
0.196
0.232
0.275
max
0.116
0.129
0.145
0.163
0.185
0.201
0.239
0.282
lbs/1000ft
11.1
14.4
18.8
25.0
34.4
41.1
59.6
86.8
Page 5 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
400R SIGNAL WIRE & CABLE
Document number: TTDSIssue: 1
Date: January 2016
Four Core 400R1141-xx (600v)
Construction Details
Part Number
Wire
Size
Shield size
AWG
26
24
22
20
18
16
14
12
AWG
36
36
36
36
36
36
36
36
Jacket thickness
Diameter
Maximum
weight
inch
400R1141-26-*
400R1141-24-*
400R1141-22-*
400R1141-20-*
400R1141-18-*
400R1141-16-*
400R1141-14-*
400R1141-12-*
inch min
0.006
0.006
0.006
0.007
0.007
0.007
0.007
0.008
inch nom
0.008
0.008
0.008
0.009
0.009
0.009
0.009
0.010
nom
0.119
0.134
0.151
0.172
0.196
0.213
0.254
0.302
max
0.137
0.154
0.175
0.200
0.229
0.249
0.298
0.355
lbs/1000ft
14.0
17.6
23.1
31.4
42.9
51.7
74.1
108.0
Page 6 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
Document number: TTDSIssue: 1
Date: January 2016
APPROVALS &
DECLARATIONS:
Operating temperature
Maximum operating
Temperature
400R SIGNAL WIRE & CABLE
NFPA 130 Vertical Flammability
BSS 7238 Ds Smoke 4 Minutes
BSS 7238 Dm Smoke 4 Minutes
BSS 7239 Toxicity
-65°C to +125°C
125°C / 10 Years
110oC / 30 Years
Fire Hazard
Low toxicity, Low smoke, Highly flame retarded
Voltage rating
400R*1** 600V
400R*3** 2,500V
Conductor size range
26AWG-00AWG
Construction
Single core and multi core
Colours
Single core insulation available in all colour codes 0-9
Standard insulation colours black & white
Conductors
Tin plated copper stranded
Page 7 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
Document number: TTDSIssue: 1
Date: January 2016
400R SIGNAL WIRE & CABLE
FIRE HAZARD PERFORMANCE
TEST
Flammability – small scale
METHOD
Smoke Testing
NFPA 130
FT4 / IEEE 1202
BSS 7238
Toxicity
BSS 7239
RESULT
Char Length < 1.5m
Ds < 50 @ 4 minutes
Dm < 300 @ 4 minutes
HCN < 100 ppm
CO < 3500 ppm
SO2 < 100 ppm
HF < 100 ppm
HCL < 500ppm
Page 8 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
400R SIGNAL WIRE & CABLE
Document number: TTDSIssue: 1
Date: January 2016
GENERAL PROPERTIES (See WSD for full details)
TEST
Maximum Temperature Rating
Voltage Rating
Accelerated Aging
Blocking
Jacket Colour
Dielectric Withstand 600V
2,500V
Jacket Concentricity
Jacket Elongation
600V
2,500V
Jacket TS
600V
2,500V
Jacket Flaws
600V
2,500V
o
REQUIREMENT
-65 to +125 C
600V, 1,000V, 2,500V ACRMS Depending on type
300oC +/- 3oC for 6 hours
150oC +/- 3oC for 6 hours
White Preferred
2,500V AC RMS, 60Hz 1 minute
5,000V AC RMS, 60Hz 1 minute
70% Minimum
200% Minimum
150% Minimum
27.5 MPa minimum
17.2 MPa minimum
High Frequency 4.2KV AC RMS @ 3KHz
Impulse
6.0KV Peak
High Frequency 8.0KV AC RMS @ 3KHz
Impulse
13.0KV Peak
Page 9 of 10
Business
Businesslocations:
locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.
TECHNICAL DATA SHEET
400R SIGNAL WIRE & CABLE
Document number: TTDSIssue: 1
Date: January 2016
GENERAL PROPERTIES (See WSD for full details)
TEST
Shield Coverage
Voltage Withstand
REQUIREMENT
600V
2,500V
Humidity Resistance
85% Minimum
2,500V AC RMS, 60Hz 1 minute
5,000V AC RMS, 60Hz 1 minute
IR 5,000 M Ohms.1000ft Minimum
Page 10 of 10
Business locations:
( Asia: +86-21-33980184
( Australia: 1-800-144-078
( Eire: 800-557-810
( Germany: + 49 (0) 173-3169004
(
(
(
(
New Zealand: 0800-TYCO-HELP
N America: + 1-800-430-7226 X4 (East Coast)
N America: + 1-800-430-7226 X5 (West Coast)
UK: + 44 (0) 800988 9177
While TE Connectivity Ltd. has made every reasonable effort to ensure the accuracy of the information in this document, TE does
not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is
accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any
time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not
limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for
reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE
for the latest dimensions and design specifications.