0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EP5675-000

EP5675-000

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

    11(5 根双绞线 + 1) 芯 多芯 线缆 黑色 24 AWG,26 AWG 编织线 在订单数量中输入英尺数

  • 数据手册
  • 价格&库存
EP5675-000 数据手册
SPECIFICATION CONTROL DRAWING U31-26C493C124 6/14/2021 Date: Revision: Issue B Page 1 of 2 USB CABLE 3.1 THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. CONSTRUCTION DETAILS Conductor Insulation Drainwire Shield Wrap Wrap Shield Jacket Data Pair A (Data) Dimensions Inches (nom) Conductor: AWG 26 19/38 SCHCA .0185 Insulation: Foamed FEP .035 Conductor: AWG 26 19/38 SCHCA .0185 Insulation: Foamed FEP/FEP .044 Drainwire: AWG 26 19/38 SCHCA .0185 Shield: AWG 40 Silver copper (90% min coverage) .101 Wrap: PTFE .004 (25% min overlap) .109 Data Pairs B (Data) Twisted Pair Cable C (Power) Conductor: AWG 24 19/36 SCHCA .0233 Insulation: FEP .0395 1 of component A 2 of component B 1 of component C .222 Cable Assembly TABLE I Core: Data Pair Wire Insulation Color A 1 9 (white) / 5L (light green) Wrap: PTFE .004 (25% min overlap) .230 Shield: AWG 38 silver copper (90% min coverage) .247 Jacket: FEP .015 Weight: 52.44 lbs/kft B 1 3L (light orange) / 7L (light purple) B 2 4L (light yellow) / 6L (light blue) Power Cable C 1 2 (red) / 0 (black) .277 +.014 Color code designators shall be in accordance with MIL-STD-681. Designate outer jacket color with a dash number appended to the part number. Example: Black jacket; U31-26C493C124-0. ADDITIONAL REQUIREMENTS & RATINGS Temperature Rating: 200°C Voltage Withstand: 1500 volts (rms), conductor to conductor 500 volts (rms) shield to shield when applicable per NEMA WC 27500 Jacket Flaws: Spark Test 2.5 kV (rms) Impulse Dielectric 6.0 kV (peak Flammability: Shall meet the requirements of FAR part 25, Appendix F, Part 1 when tested in accordance with the 60 degree test specified therein. Jacket Tensile strength: 2000 psi minimum Jacket Elongation: 200% min Cable will be supplied in 50 ft minimum lengths unless otherwise specified Other codes and suffixes may be added to the part number, as necessary, to capture any additional requirements imposed by the purchase. Users should evaluate the suitability of this product for their application. TE Connectivity Corporation also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. This specification sheet takes precedence over documents referenced herein. Referenced documents shall be of the issue in effect on date of invitation for bid. TE Connectivity Corporation Raychem Wire & Cable 501 Oakside Avenue Redwood City, California 94063-3800 1-800-227-8816 Fax: 1-650-361-6297 Raychem, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. © 2021 TE Connectivity Corporation. All rights reserved. SPECIFICATION CONTROL DRAWING U31-26C493C124 Date: 6/14/2021 Issue: Issue B Page: 2 of 2 ELECTRICAL REQUIREMENTS Data Pair A (Data) Impedance 90±13.5 ohms Skew: 100 ps/4.5m (max) Insertion loss (max): 100 MHz - 2.9 dB/4.5m 200 MHz - 4.2 dB/4.5m 400 MHz - 6.8 dB/4.5m Data Pairs B (Data) Impedance: 90±5 ohms Intra-pair Skew: 15 ps/m (max) Insertion loss (nom): 630 MHz 1.25 GHz 2.5 GHz 5.0 GHz 7.5 GHz - 2.9 dB/m 4.3 dB/m 5.9 dB/m 6.7 dB/m 7.00 dB/m Component Data Pair A Differential NEXT : Maximum limit defined by the vertices: 32 dB at 100 MHz and 2500 MHz. 23 dB at 3 GHz 23 dB at 7.5 GHz (4.5m sample) Component Data Pairs B NEXT and FEXT : Maximum limit defined by the vertices: 21 dB at 100 MHz and 2500 MHz 15 dB at 3 GHz 15 dB at 7.5 GHz (4.5m sample)
EP5675-000 价格&库存

很抱歉,暂时无法提供与“EP5675-000”相匹配的价格&库存,您可以联系我们找货

免费人工找货