0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FX293X-100A-0010-L

FX293X-100A-0010-L

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
FX293X-100A-0010-L 数据手册
te.com FX29 Compact Compression Load Cell Versatile Miniature Force Sensor mV, Amplified, and Digital Outputs Low Power Consumption Rugged Microfused Sensing Element Stainless Steel Enclosure Several Load Ranges TE Connectivity’s (TE) FX29 is a compact compression load cell that offers exceptional price-to-performance in a robust sensor package. Optimized for embedded force sensing applications from disposable medical devices to durable appliances and exercise equipment. The FX29 allows design flexibility with mV, amplified, and digital output options. Features • Compact Design The FX29 incorporates the high reliability Microfused technology and is offered in ranges from 10lbf to 200lbf (50N to 1000N). Microfused technology provides excellent span and zero stability, outstanding cycle life, superior resolution, high over-range capabilities, and an unamplified span sensitivity of 20mV/V. • mV or Amplified Analog Outputs • Optional I2C Digital Interface • High Over Range Capability The FX29 utilizes a two-piece construction of stainless steel materials. The combination of a metal injection molded flexure and micro miniaturized MEMS strain gauges allows flexibility of force range options for a lower cost sensor. These improvements over previous load cell designs give the FX29 more precise dimensional control and better performance. Applications • Medical Infusion Pumps • Analog & Digital Scales • Fitness & Exercise Equipment • Payload Weighing • Power Tools • Robotics • Surgical & Dental Tools • Battery Powered Devices • Manufacturing Equipment CLICK HERE › CONNECT WITH A SPECIALIST TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 1 FX29 Compact Compression Load Cell Absolute Maximum Ratings (Analog) (1) Parameter Symbol Supply voltage Vdd Storage temperature TS Compressive load Min Typ Max Units Notes/Conditions 6.0 V Analog mV Output 5.25 V Analog 0.5-4.5V Output +85 °C 2.5X Rated 4.0 kV Human Body Model Max Units Notes/Conditions 1.00 6.0 V mV Output only 4.75 5.25 V 0.5-4.5V Output only 3 mA 0.5-4.5V Output only -40 Lmax ESD -4.0 (1) Maximum limits the device will withstand without damage Standard Load Ranges Pounds-Force (lbf) 10 Newtons (N) 50 25 125 50 250 100 500 200 1000 Electrical Specifications (Analog) (Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied) Parameter Symbol Min Typ Supply voltage (Vsupply) Vdd Operating current Idd Input resistance Rin 2.4 3.0 3.6 kΩ mV Output only Output resistance Rout 1.76 2.2 2.64 kΩ mV Output only 2.0 ms 10% to 90% mA 0.5-4.5V Output only seconds 0.5-4.5V Output only MΩ @250VDC Rise time Tr Maximum output current Io Output short circuit duration Ts Insulation resistance 2.2 50 Bandwidth TE CONNECTIVITY SENSORS /// FX29 ∞ 1.0 DOC CONTROL NUMBER 05142019 kHz 10/2020 Page 2 FX29 Compact Compression Load Cell Operating Specifications (Analog) (Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied) Parameter Symbol Min Typ -15 Zero offset1 Max Units Notes/Conditions 15 mV/V mV Output only 300 500 700 mV 0.5-4.5V Output only 16 20 24 mV/V mV Output only 3800 4000 4200 mV 0.5-4.5V Output only -1 1 %Span BFSL Hysteresis -0.8 0.8 %Span Zero repeatability -0.8 0.8 %Span Span repeatability -0.8 0.8 %Span Thermal shift for zero -0.05 0.05 %Span/°C Thermal shift for span -0.05 0.05 Cycle life 1E+6 Full scale span1 Non-linearity 0 to full scale cycles Deflection at rated load 0.03 Weight (1) Reference to 25°C, over compensated temperature %Span/°C 6.0 mm grams Without ribbon cable Max Units Notes/Conditions 0.5-4.5V Output only Span and zero offset are ratiometric to power supply voltage Environmental Specifications (Analog) (Unless otherwise specified, all parameters are measured at 25°C @ 5.0V applied) Parameter Compensated temperature range Storage temperature Symbol Min To 0 50 °C Ts -40 85 °C 0 85 %RH Ambient humidity IEC61000-4-2 (8kVair/4kVcontact) IEC61000-4-3 (3V/m) EN55032 Class A EMI/RFI/ESD protection Ingress protection Media compatibility TE CONNECTIVITY SENSORS /// FX29 Typ IP Non-condensing mV Output only 43 External exposed surfaces: 17-4 and 304 stainless steel DOC CONTROL NUMBER 05142019 Excluding cable & connector 10/2020 Page 3 FX29 Compact Compression Load Cell Schematic Diagram – mV output (Analog) Block Diagram – 0.5 to 4.5V output (Analog) Vdd ANALOG OUTPUT TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 4 FX29 Compact Compression Load Cell Absolute Maximum Ratings (Digital) (1) Parameter Symbol Min Typ Supply voltage Storage temperature TS Compressive load Lmax ESD (1) -40 Max Units 5.50 V +85 °C 2.5X Rated 4.0 kV Human Body Model Max Units Notes/Conditions 5.5 V 3 mA 5 µA -4.0 Notes/Conditions Maximum limits the device will withstand without damage Standard Load Ranges Pounds-Force (lbf) 10 Newtons (N) 50 25 125 50 250 100 500 200 1000 Electrical Specifications (Digital) (Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied) Parameter Symbol Min Supply voltage (Vsupply) Vdd 2.7 Operating current Idd Sleep mode current Islp Insulation resistance TE CONNECTIVITY SENSORS /// FX29 Typ 0.5 50 DOC CONTROL NUMBER 05142019 MΩ @250VDC 10/2020 Page 5 FX29 Compact Compression Load Cell Force Operating Specifications (Digital) (Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied) Parameter Symbol Min Typ Max Units Notes/Conditions 300 1000 1700 Counts Base10 14300 15000 15700 Counts Base10 -1 1 %Span BFSL Hysteresis -0.8 0.8 %Span Zero repeatability -0.8 0.8 %Span Span repeatability -0.8 0.8 %Span Thermal shift for zero -0.05 0.05 %Span/°C Thermal shift for span -0.05 0.05 Cycle life 1E+6 Zero offset Full scale span Non-linearity A/D resolution 0 to full scale cycles 14 Bits Response time Deflection at rated load Weight Reference to 25°C, over %Span/°C compensated temperature 3 mS 4MHz, non-sleep mode 8.4 mS 4MHz, sleep mode 0.03 mm 6.0 grams Without ribbon cable Max Units Notes/Conditions Environmental Specifications (Digital) (Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied) Parameter Compensated temperature range Storage temperature Symbol Min To 0 50 °C Ts -40 85 °C 0 85 %RH Ambient humidity Ingress protection Media compatibility TE CONNECTIVITY SENSORS /// FX29 IP Typ Non-condensing 43 External exposed surfaces: 17-4 and 304 stainless steel DOC CONTROL NUMBER 05142019 Excluding cable & connector 10/2020 Page 6 FX29 Compact Compression Load Cell Block Diagram – I2C Digital Output (Digital) SDA SCL TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 7 FX29 Compact Compression Load Cell Force Output Graph (Digital) � � %Output 0% 5% 10% 50% 90% 95% 100% = 4 � � �� ∗ � + Force Sensor Output Counts (decimal) Counts (hex) 1000 0x3E8 1700 0x6A4 2400 0x960 8000 0x1F40 13600 0x3520 14300 0x37DC 15000 0x3A98 I2C Typical Circuit Note: only one pair of pull up resistors are needed for multiple sensing devices. TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 8 FX29 Compact Compression Load Cell I2C Interface Parameter Symbol Min SCLK clock frequency FSCL 100 Start condition hold time relative to SCL edge tHOSTA 0.1 µS tLOW 0.6 µS tHIGH 0.6 µS Minimum SCL clock low width1 Minimum SCL clock high width1 Typ Max Units 400 kHz Start condition startup time relative to SCL edge Data hold time on SDA relative to SCL edge Data setup time on SDA relative to SCL edge tSUSTA 0.1 µS tHDDAT 0 µS tSUDAT 0.1 µS Stop condition setup time on SCL tSUSTO 0.1 µS tBUS 2 µS Bus free time between stop and start condition Notes/Conditions I2C Interface Timing Diagram Digital Input and Output Parameters (Unless otherwise specified, all parameters are measured at 25°C @ 3.0V applied) Symbol Min Max Units Input high voltage Parameter VIH 0.8 Typ 1.0 x Vdd Input low voltage VIL 0.0V 0.2 x Vdd Output low level x Vdd Load capacitance @ SDA 200 pF Input capacitance (each pin) 10 pF TE CONNECTIVITY SENSORS /// FX29 Notes/Conditions DOC CONTROL NUMBER 05142019 @400 kHz 10/2020 Page 9 FX29 Compact Compression Load Cell I2C Measurement Packet Read Sequence TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 10 FX29 Compact Compression Load Cell General Working Mode TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 11 FX29 Compact Compression Load Cell Outline Drawing and Connections TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 12 FX29 Compact Compression Load Cell Mounting Recommendation The sensor can be put into a simple slot fixture for load testing. The load should be applied to the spherical face of center boss. Recommended to stick the sensor with double face 3M adhesive or glue. Some feature to clamp the sensor from top to down can be optional. See below for reference: NOTE: Clamping force may shift the zero reading slightly. Re-zero if needed. Below table shown the Zero change difference when loaded 5 Lbf from the top. (For reference only) Load Range 10L 25L 50L 100L Changing for reference ±0.5%FS ±0.4%FS ±0.35%FS ±0.25%FS Dimension for reference: TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 13 FX29 Compact Compression Load Cell Ordering Information Output Signal Code Output 2 20 mV/V* 3 0.5 – 4.5V* J I2C (None Sleep) K I2C (Sleep)* FX29 X X – XXX X – XXXX – X Measurement Units L Pounds-force (lbf)* N Newtons Output Type mV Amplified Digital Load Range LBF 0010* 0025* 0050* 0100* 0200* Digital I2C Address Code Device Address (hex) X Analog Output* 0 0x28* 1 0x36 2 0x46 3 0x48 4 0x51 Cable Length Code Length 040 40 mm* 100 100 mm* XXX Custom Length (MACHINING) Newtons 0050 0125 0250 0500 1000 Cable & Connector Code Cable and Connector A 4-wire ribbon cable without connector B 4-wire ribbon cable with connector* Note: For digital output, ensure custom cable length does not exceed 1 meter. *Sensor features shown in bold are typically stocked by our distribution partners, or available with short lead times from the factory depending on availability. Contact customer service for details. Caution: For the digital sensor. User can change the address along with the guide as below link. Please notice, any data changed by users means users give up the quality assurance terms. TE will not guarantee the sensor performance any more. https://www.te.com/commerce/DocumentDelivery/DDEController?Action=showdoc&DocId=Specification+Or+Standard%7FDIGITAL_MODEL S_CHANGING_I2C_SLAVE_ADDRES%7FA1%7Fpdf%7FEnglish%7FENG_SS_DIGITAL_MODELS_CHANGING_I2C_SLAVE_ADDRES_A1 .pdf%7FCAT-PTT0015 TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 14 FX29 Compact Compression Load Cell REVISION HISTORY Revision Number Change Description Date Approval A3 Minor corrections ; 06/24/2019 MH A4 Correct pin numerical to be same as connector 07/29/2020 MH A5 Mounting Recommendation and Caution added; 10/27/2020 MH CLICK HERE › CONNECT WITH A SPECIALIST NORTH AMERICA Tel +1 800 522 6752 EUROPE Tel +31 73 624 6999 ASIA Tel +86 0400 820 6015 te.com/sensors Microfused, Measurement Specialties (MEAS), TE Connectivity, TE, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. © 2020 TE Connectivity Corporation. All Rights Reserved. TE CONNECTIVITY SENSORS /// FX29 DOC CONTROL NUMBER 05142019 10/2020 Page 15
FX293X-100A-0010-L 价格&库存

很抱歉,暂时无法提供与“FX293X-100A-0010-L”相匹配的价格&库存,您可以联系我们找货

免费人工找货