File E28476
Service Request: 1181364
Issued: July 13, 2009
Revised: January 31, 2023
REPORT
on
COMPONENT –
Connectors for Use in Data, Signal, Control and Power
Applications - Component
TYCO ELECTRONICS CORP
MIDDLETOWN,PA
Copyright 2009 Underwriters Laboratories Inc.
UL LLC authorizes the above named company to reproduce this Report provided
it is in its entirety.
UL LLC authorizes the above named company to reproduce the latest pages of
that portion of this Report consisting of this Cover Page through Page 3.
File E28476
Vol. 124
Sec. 2
and Report
Page 1
Issued:
Revised:
2009-07-13
2023-01-31
DESCRIPTION
PRODUCT COVERED:
USR – Component Connectors, Series YHDP24 or YHDP26 or HDP24- or HDP26, followed by 18-6-, 18-8-, 18-14-, 18-20-, 18-21-, 24-9-, 24-14-, 24-16-,
24-18-, 24-19-, 24-21-, 24-23-, 24-29-, 24-31-, 24-33-, 24-34-, 24-35-, or
24-47- or 24-91-, followed by P or S, followed by N, T, or E, followed by
four alphanumeric characters.
USR – Component Connectors Cat. Nos. 2293821-1, 2293822-1, 2294433-1,
2294434-1, 2294435-1, 2294479-1, 2294482-1, 2294488-1.
.
GENERAL:
These devices are multi-pole connectors intended for factory assembly
on stranded copper conductors where the acceptability of combinations is
determined by UL LLC. The devices are identified as follows:
USR indicates investigation to United States Standards as referenced in
the Test Record.
Disconnecting Use - see Sec Gen for required marking
*
File E28476
Vol. 124
Sec. 2
and Report
Page 1A
Issued:
New:
2009-07-13
2023-01-31
CAT NO NOMENCLATURE:
Y
A
HDP
I
2
II
6
III
-24-21
IV
S
V
N
VI
L024
VII
A. Optional – Y - Indicates an identical construction Cat No.
I.
May be HDP Only - Designates Deutsch Heavy Duty Plastic Connector
II.
May be 2 only - Indicates Type, Bulk Packaged without Contacts or
Accessories
III.
IV.
Indicates Connector Style
4 = Receptacle (female) - Jam nut type mounting
6 = Plug (male)
Indicates Shell Size and Insert Arrangements
May be: 18-6, 18-8, 18-14, 18-20, 18-21, 24-9, 24-14, 24-16, 24-18,
24-19, 24-21, 24-23, 24-29, 24-31, 24-33, 24-34, 24-35, or 24–47 or 2491.
Refer to Ills. 1 and 32 for specific arrangement layout
V.
Indicates Contact style
P = Pin (male)
S = Socket (female)
VI.
Indicates Wire sealing options, colors indicate slight dimensional
diameter variation, to accommodate different wire insulation ranges and
outer diameters. May be either N, T, or E.
N = Normal position & wire seals (green ring)
T = Thin wall wire seals (gray ring)
E = Extra thin wall wire seals (blue ring)
VII. Special Modifications
Four Alphanumeric characters – Assigned for Commercial Purposes only
File E28476
Vol. 124
Sec. 2
and Report
Page 1B
Issued:
New:
2009-07-13
2023-01-31
The following table lists Cat. Nos that are identical except for Cat. No.
designation.
Cat. No.
Identical
YHDP24-18-14PEL024
HDP24-18-14PE-L024
YHDP24-18-20PEL024
HDP24-18-20PE-L024
YHDP24-18-20PNL024
HDP24-18-20PN-L024
2293821-1
HDP24-18-8PE-L024
2293822-1
HDP24-24-16PE-L024
YHDP24-24-18PEL024
HDP24-24-18PE-L024
YHDP24-24-18PNL024
HDP24-24-18PN-L024
YHDP24-24-19PEL024
HDP24-24-19PE-L024
YHDP24-24-21PEL024
HDP24-24-21PE-L024
YHDP24-24-21PNL024
HDP24-24-21PN-L024
YHDP24-24-23PEL024
HDP24-24-23PE-L024
YHDP24-24-29PEL024
HDP24-24-29PE-L024
YHDP24-24-31PEL024
HDP24-24-31PE-L024
2294433-1
HDP24-24-31PT-L024
2294434-1
HDP24-24-33PN-L024
YHDP24-24-35PEL024
HDP24-24-35PE-L024
YHDP24-24-47PEL024
HDP24-24-47PE-L024
YHDP24-24-9PE-L024
HDP24-24-9PE-L024
2294435-1
HDP26-24-18PN-L024
YHDP26-24-19PEL024
HDP26-24-19PE-L024
2294479-1
HDP26-24-21PN-L024
YHDP26-24-23PEL024
HDP26-24-23PE-L024
YHDP26-24-31PEL024
HDP26-24-31PE-L024
2294482-1
HDP26-24-31PT-L024
YHDP26-24-35PEL017
HDP26-24-35PE-L017
2294488-1
HDP26-24-9PN-L024
File E28476
Vol. 124
Sec. 2
and Report
Page 1C
Issued:
New:
2009-07-13
2023-01-31
ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE):
Use - For use only in or with complete equipment where the
acceptability of the combination is determined by UL LLC.
Conditions of Acceptability - The following are among the
considerations to be made when evaluating the device in the end-use product.
Interruption of Current
1.
These devices are not suitable for interrupting the flow of current by
connecting or disconnecting the mating connector.
Current-Carrying Capability and Current Ratings
2.
These devices have not been subjected to the Temperature test and as a
result do not have an assigned current rating. The device’s current
carrying capability is to be reviewed in the end-use by measuring
temperatures on the connector housing and/or terminals when current is
flowing through the connector under conditions of normal use.
File E28476
Vol. 124
Sec. 2
and Report
Page 2A
Issued:
Revised:
2009-07-13
2017-03-07
8.
The following crimp contacts have been evaluated for the wire sizes as tabulated
below:
Stamped and Formed Type -
Pin / Socket
1060-12-0222 / 1062-12-0222
1060-12-0166 / 1062-12-0166
1060-16-0122 / 1062-16-0122
1060-16-0622 / 1062-16-0622
1060-16-0622 / 1062-16-0622
1060-16-0144 / 1062-16-0144
1060-16-0988 / 1062-16-0988
1060-16-1222 / 1062-16-1222
1060-14-0122 / 1062-14-0122
1060-20-0222 / 1062-20-0222
1060-20-0222 / 1062-20-0222
1060-20-0122 / 1062-20-0122
1060-20-0122 / 1062-20-0122
Solid Type *Socket
0462-203-04141 /
0462-203-08141 /
0462-203-12141 /
0462-209-16141 /
0462-201-16141 /
0462-201-16141 /
/ Pin
0460-204-0490
0460-204-08141
0460-204-12141
0460-215-16141
0460-202-16141
0460-202-16141
Wire Size, AWG
10
12, 14
14 – 18
16, 18
20
14 - 18
14 - 18
12 - 16
14 – 18
16, 18
20
16, 18
20
Wire Size, AWG
6
8
12, 14
14
16, 18
20
Force, lbf
20
20
20
20
8
20
20
20
20
20
8
20
8
Force, lbf
20
20
20
20
20
8