HPP804B131

HPP804B131

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

    HPP804B131 - TEMPERATURE AND RELATIVE HUMIDITY SENSOR - Humirel

  • 数据手册
  • 价格&库存
HPP804B131 数据手册
TECHNICAL 1 DATA TEMPERATURE AND RELATIVE HUMIDITY SENSOR HTS2030SMD Meets RoHS regulations Based on a unique capacitive cell for humidity measurement and a Negative Temperature Coefficient (NTC) thermistor for temperature measurement, this dual purpose relative humidity / temperature miniaturized sensor is designed for high volume, cost sensitive applications with tight space constraints. It is useful in all applications where dew point, absolute humidity measurements or humidity compensation are required. MAIN FEATURES ● Miniature Surface mount SMD package. ● Lead free components. ● Full interchangeability with no calibration required in standard conditions. ● Instantaneous desaturation after long periods in saturation phase. ● Compatible with automatized assembly processes, including Pb free wave soldering and reflow processes (1) ● High reliability and long term stability. ● Patented solid polymer structure. ● Suitable for linear voltage or frequency output circuitry. ● Fast response time and very low temperature coefficient. ● Part may be washed with distilled water. ● Individual marking for compliance to stringent traceability requirements. (1) soldering temperature profiles available on request / contact us at application@humirel.com Operating Range 100 MAXIMUM RATINGS Ratings Symbol Value Unit Relative Humidity in % RH 90 80 Operating Temperature Storage Temperature Supply Voltage (Peak) Humidity Operating Range Ta Tstg Vs RH -60 to 140 -60 to 140 10 0 to 100 °C °C Vac % RH 70 60 50 40 30 20 10 0 -60 -40 -20 0 20 40 60 80 100 120 140 160 Temperature in °C CHARACTERISTICS Humidity sensor (Ta = 25°C, measurement frequency @ 10kHz unless otherwise noted) Characteristics Symbol Min. Typ. Max. Unit. Humidity measuring range Supply voltage Nominal capacitance @ 55% RH* Temperature coefficient Averaged Sensitivity from 33% to 75% RH Leakage current (Vcc = 5 Volts) Recovery time after 150 hours of condensation Humidity Hysteresis Long term stability Time constant (33 to 80 % RH, still air @ 63%) Deviation to typical response curve (10% to 90%) RH) RH Vs C Tcc ∆C /% RH I tr 1 99 10 %RH V pF pF/°C pF/% RH 177 180 183 0.01 0.31 1 10 +/-1 nA s %RH %RH/yr s %RH τ ta +/-0.5 3 +/-2 5 *tighter specification available on request HUMIREL HPC055 Rev0 June 2004 HTS2030SMD TECHNICAL 2 DATA TYPICAL RESPONSE IN HUMIDITY • Polynomial response of HTS2030SMD: C (pF)=C@55 %*( 3.903 10-8 *RH3-8.294 10-6 *RH2+2.188 10-3 *RH+0.898) Typical response look-up table (Polynomial Reference curve) “10kHz/1V” RH (%) Cp (pF) RH (%) Cp (pF) 195 190 185 180 175 170 165 160 0 10 20 30 40 50 %RH 0 161.6 5 163.6 10 165.4 15 167.2 20 169.0 25 170.7 30 172.3 35 173.9 40 175.5 45 177.0 50 178.5 55 180 60 181.4 65 182.9 70 184.3 75 185.7 80 187.2 85 188.6 90 190.1 95 191.6 100 193.1 C apa citanc e (pF) 60 70 80 90 100 • Reversed Polynomial response of HTS2030SMD: RH (%) = -3.4656 10+3 *X3+1.0732 10+4 *X2-1.0457 10+4 *X+3.2459 10+3 With X=C(read) / C@55%RH CHARACTERISTICS Temperature sensor Characteristics Nominal resistance @ 25°C Beta value : B25/100 Temperature measuring range Nominal Resistance Toleranceat 25°C B value tolerance Response Time Symbol B Ta Rn B τ Min. 3600 -60 2 3 10 Typ 10 3730 Max. 3800 140 3 °C % % s Unit. kΩ TYPICAL TEMPERATURE OUTPUT HUMIREL HPC055 Rev0 June 2004 HTS2030SMD TECHNICAL Temperature look-up table Temp °C -40 -39 -38 -37 -36 -35 -34 -33 -32 -31 -30 -29 -28 -27 -26 -25 -24 -23 -22 -21 -20 -19 -18 -17 -16 -15 -14 -13 -12 -11 -10 -9 -8 -7 -6 Resistance (Ohm) 262960 247217 232539 218845 206064 194110 182852 172332 162498 153299 144790 136664 129054 121925 115243 109030 103115 97565 92354 87460 82923 78581 74497 70655 67039 63591 60381 57356 54503 51813 49204 46767 44467 42296 40247 Max. deviation 35403 32777 30358 28130 26075 24178 22416 20791 19290 17905 16636 15444 14343 13325 12383 11516 10705 9953 9257 8612 8020 7463 6947 6468 6023 5606 5222 4865 4533 4225 3932 3662 3411 3177 2960 Temp °C -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Resistance (Ohm) 38279 36455 34731 33100 31557 30029 28627 27299 26042 24852 23773 22708 21698 20739 19829 18959 18128 17338 16588 15876 15207 14569 13962 13384 12834 12280 11777 11297 10840 10404 10000 9600 9218 8853 8506 Max. deviation 2756 2568 2393 2230 2078 1932 1799 1675 1560 1452 1355 1261 1174 1093 1017 946 879 817 759 705 654 607 563 522 484 447 413 382 353 325 300 300 300 299 297 Temp °C 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Resistance (Ohm) 8178 7866 7568 7283 7011 6734 6484 6244 6015 5796 5575 5373 5180 4995 4817 4636 4473 4316 4166 4021 3874 3737 3606 3481 3360 3237 3126 3019 2917 2819 2720 2629 2542 2458 2378 Max. deviation 296 294 292 290 287 284 281 278 275 271 267 264 260 257 253 248 245 241 237 233 229 225 221 217 213 208 204 200 197 193 189 185 182 178 175 Temp °C 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 3 DATA Resistance (Ohm) 2304 2229 2158 2089 2022 1960 1898 1839 1782 1727 1673 1622 1573 1526 1480 1432 1390 1349 1310 1272 1235 1199 1163 1130 1097 1067 1038 1009 982 955 927 901 877 853 830 Max. deviation 171 168 165 161 158 155 152 149 146 143 140 138 135 132 130 127 124 122 119 117 115 112 110 108 106 104 102 100 98 96 94 92 90 89 87 SUGGESTED FREQUENCY OUTPUT CIRCUITS Note: R22=499kΩ / R4=49.9kΩ / R1=1 kΩ / RV1=50 kΩ potentiometer / C1=10nF / C2=2.2nF / C3=100nF Typical response look-up table (Humidity output) RH (%) Fout (Hz) RH (%) Fout (Hz) 55 6600 60 6550 0 5 10 7155 65 6500 15 7080 70 6450 20 7010 75 6400 25 6945 80 6355 30 6880 85 6305 35 6820 90 6260 40 6760 95 6210 HTS2030SMD 45 6705 100 50 6650 HUMIREL HPC055 Rev0 June 2004 TECHNICAL 4 DATA QUALIFICATION PROCESS HTS2030SMD sensors have been qualified through a complete qualification process taking in account many of the requirements of the JEDEC standard including: • • • • • • • • Solder heat and solderability including lead free process. Pb free wave soldering and reflow soldering process(260°C) + DI water clean at 45°C Mechanical shock JESD-22-B104-A Vibration - Variable frequency(20 to 2000Hz) JESD-22-B103-A Marking permanency ESD - Electrostatic Discharge –Air Gun +-15kV(IEC 1000) Salt Atmosphere JESD22-A107-A Temperature Cycling - 40°C / +125°C • • • • • High Temperature / Humidity Operating Life - 93%RH / 60°C for 1000 hours Low Humidity storage life - RH < 10%/23°C - 1000 hours Resistance to immersion in water at ambient temperature and 80°C High temperature storage 140°C for 168 hours. Resistance to many chemicals linked to home appliances/automotive or consumer applications. ENVIRONMENTAL AND RECYCLING HTS2030SMD sensors are lead free components and are compatible with Pb Free soldering processes.HTS2030SMD sensors are free from Cr (6+), Cd and Hg. SOLDERING INSTRUCTIONS See Application Note. To get it, please contact: application@humirel.com PACKAGE OUTLINE HTS2030SMD GULL WING (JLEAD option also available) Dimensions in millimeters FOOTPRINT ORDERING INFORMATION of HTS2030SMD: • HPP804B130: TUBE M.P.Q. OF 78 PIECES. • HPP804B131: TAPE AND REEL M.P.Q. OF 1500 PIECES. TEMPERATURE AND RELATIVE HUMIDITY SENSORS. The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsability is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Humirel reserves the right to make changes without further notice to any product herein. Humirel makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Humirel assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. « Typical » parameters can and do vary in different applications. All operating parameters, including « Typical » must be validated for each customer applications by customer’s technical experts. Humirel does not convey any license under its patent rights nor the rights of others. Humirel products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other application intended to support or sustain life, or for any application in which the failure of the Humirel product could create a situation where personal injury or death may occur. Should buyer purchase or use Humirel products for any such unintended or unauthorized application, Buyer shall indemnify and hold Humirel and its officers, employees, subsidaries, affiliates and distributors harmless against all claims, costs, damages and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of presonal injury or death associated with such unintended or unauthorized use, even if such claim alleges that Humirel was negligent regarding the design or manufacture of the part.Humirel is a registred trade mark of Humirel. HUMIREL HPC055 Rev0 June 2004 HTS2030SMD
HPP804B131 价格&库存

很抱歉,暂时无法提供与“HPP804B131”相匹配的价格&库存,您可以联系我们找货

免费人工找货