Solid State Relay
Potter & Brumfield
IAC Series
AC Input Module
File E29244
Users should thoroughly review the technical data before selecting a
product part number. It is recommended that users also seek out the
pertinent approvals files of the agencies/laboratories and review them to
ensure the product meets the requirements for a given application.
Engineering Data
Features
Switch Form: 1 Form A (SPST-NO)
Duty: Continuous.
Operating Temperature: –30°C to +80°C.
Storage Temperature: –30°C to 100°C.
Potting Compound Flammability: UL94V-0.
Approximate Weight: 1.38 oz. (35g).
• Industry standard package and pin-out.
• Color coded by function.
• 4000V rms optical isolation.
• High immunity to false operation.
• Series compatible.
• Compatible with 2IO series mounting boards.
Ordering Information
Typical Part Number
>
IAC
-5
A
1. Basic Series: IAC = AC input module - yellow case
2. Logic Voltage: 5 = 5VDC
15 = 15VDC
24 = 24VDC
3. Input: Blank = 120VAC input (90-140VAC) * *
A = 240VAC input (180-280VAC) * *
E = 18-36VAC input * *
* * Is not polarity sensitive.
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
IAC-5
IAC-5A
IAC-5E
IAC-15
IAC-24
Input Specifications
Parameter
Control Voltage Range VIN
Must Operate Voltage VIN(OP)
Must Release Voltage VIN(REL)
Max. Input Current
Input Resistance
1
02-2019, Rev. 0219
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Conditions
@VIN=Max.
IAC-5
IAC-15 IAC-24
Units
VAC
VAC
VAC
mA
Ohms
Min.
90
Typ.
120
60
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Max.
140
90
IAC-5A
IAC-15A IAC-24A
Min.
180
Typ.
240
Max.
280
180
60
1-5
IAC-5E
IAC-15E IAC-24E
Min.
18
Typ.
24
Max.
36
18
10
1-8
Current Regulator
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
0.2 - 2.0
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Solid State Relay
Potter & Brumfield
IAC Series(Continued)
AC Input Module
Output Specifications (@ +25˚C unless otherwise specified)
Parameter
Maximum Output Voltage
Maximum Output Current
Maximum Output Leakage Current
Maximum Output Voltage Drop
Logic Supply Voltage VCC
Logic Supply Current
Turn-On Time (Nominal)
Turn-Off Time (Nominal)
Output Type (Open Collector)
Conditions
VOUT=Max.
ISINK=50mA
VCC=Max.
ISINK=25mA
ISINK=25mA
Units
VDC
mADC
mA
VDC
VDC
mADC
ms
ms
IAC Operating Diagram
IAC-5
IAC-5A IAC-5E
Min.
Typ.
Max.
30
50
10
0.2
3
5
6
15
20
30
Normally Open(SINKING)
IAC-15
IAC-15A IAC-15E
Min.
Typ.
Max.
30
50
10
0.2
12
15
18
15
20
30
Normally Open(SINKING)
IAC-24
IAC-24A IAC-24E
Min.
Typ.
Max.
30
50
10
0.2
20
24
30
15
20
30
Normally Open(SINKING)
PCB Layout
Outline Dimensions
Note : Extra nut and washer will be provided on the screw, which will goes under PCB to fix the relay.
Hex Nut S= 6.35 (width across flats), Thickness = 2.40
Washer = OD : 4.85±0.25, ID: 2.75±0.15, Thickness = 0.55
02-2019, Rev. 0219
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
2
很抱歉,暂时无法提供与“IAC-5E”相匹配的价格&库存,您可以联系我们找货