KHA series
General Purpose
Dry Circuit to 5A
Multicontact
AC or DC Relay
File E22575
File LR15734
KHS
KHAU
Features
Coil Data @ 25°C
• Miniature size from 2 pole to 4 pole. A 5 pole version is available as a
special order.
• KHS hermetically sealed version UL Approved for Class 1 Division 2
hazardous locations.
• Various applications include process control, photocopier, and data
processing.
• Low cost, semiautomated construction.
Voltage: From 6 to 120VDC, and 6 to 240VAC, 50/60 Hz.
Nom. Power: DC coils - 0.9 watt; 0.5 watt minimum operate @ 25°C.
AC coils - 1.2 VA; 0.55 VA minimum operate @ 25°C.
Max. Power: DC coils - 2.0 watts @ 25°C.
Duty Cycle: Continuous.
Initial Breakdown Voltage: 500V rms, 60 Hz.
Coil Data
AC Coils
DC Coils
Contact Data @ 25°C
Arrangements: 2 Form C (DPDT), 4 Form C (4PDT).
Expected Life: 10 million operations, mechanical; 100,000 operations min.
at rated loads. Ratings are based on tests of relays with
ungrounded frames.
Initial Breakdown Voltage: 500V rms, 60 Hz., between open contacts.
1240V rms, 60 Hz., between all other
elements.
Contact Ratings
Nominal
Voltage
Resistance
in Ohms
±10% @
250C
5
6
12
24
48
90
110 *
120 *
240
32
40
160
650
2,600
9,000
11,000
13,500
—
Nominal
Inductance
in Henrys
.072
.08
.28
1.0
4.5
13.5
17.0
—
—
Resistance
in Ohms
±15%
Nominal
AC Current
in mA
—
10.5
43
160
668
—
—
3,900
12,000
—
200
100
52
25
—
—
11.0
6.0
*Note: For 220 and 240VDC, use series dropping 5W resistor of 11,000Ω.
Resistive Rating
Contact
Code
Material
1
Minimum
Maximum
Silver
100mA @
12VAC/12VDC
3A @
120VAC/28VDC
2*
Silver-cadmium
oxide
500mA @
12VAC/12VDC
5A @
120VAC/28VDC
3
Gold-silver-nickel
10mA @
12VAC/12VDC
2A @
120VAC/28VDC
4
Palladium
100mA @
12VAC/12VDC
3A @
120VAC/28VDC
5
Silver alloy
500mA @
12VAC/12VDC
3A @
120VAC/28VDC
6
Bifurcated cross bar,
gold overlay silver
Dry circuit
1A @
120VAC/28VDC
8
Gold diffused silver
50mA @
12VAC/12VDC
3A @
120VAC/28VDC
Operate Data @ 25°C
Must-Operate Voltage: DC: 75% of nominal voltage.
AC: 85% of nominal voltage.
Operate Time: 13 milliseconds typical @ nominal voltage (excluding
bounce).
Release Time: 6 milliseconds typical @ nominal voltage (excluding
bounce).
Environmental Data
Temperature Range: -45°C to +70°C operate.
-60°C to +130°C storage.
Mechanical Data
Note: Relays should only carry a maximum of 15 amps continuously for all poles combined.
*Note: KHS hermetically sealed version maximum rating is 5A @ 120VAC/28VDC.
Siemens Electromechanical Components, Inc.
Potter & Brumfield Products Division
200 S. Richland Creek Drive
Princeton, IN 47671-0001
Mountings: #3-48 stud, sockets with printed circuit or solder terminals,
or bracket plate with #6-32 threaded stud.
Termination: Printed circuit or solder/socket terminals.
Printed circuit terminals are available for KHS on a special
order basis.
Insulating Material: Molded high-dielectric material.
Enclosures: See Ordering Information table.
Cover colors are available in black, red, blue, yellow and
green by special order.
Weight: 1.6 oz. approx. (45g).
Specifications and availability subject to change without notice.
13CXXXX
Printed in U.S.A.
PX/X-XX
Ordering Information
Typical Part No.
B
KHA
U
-17
A
1
1
1. Basic Series: (See Note 1)
2. Type:
E = Printed circuit terminals, nylon dust cover, contacts rated opposite polarity (UL & CSA).
F = Printed circuit terminals, nylon dust cover, contacts rated same polarity (UL & CSA).
S = Solder terminals, hermetically sealed steel case (UL & CSA). Note: Do not ground
KHS frame without consulting factory for load levels. (Order as KHS, not KHAS.)
U = Solder terminals, clear polycarbonate dust cover, contacts rated same polarity
(UL & CSA).
X = Solder terminals, clear polycarbonate dust cover, contacts rated opposite polarity
(UL & CSA).
3. Contact Arrangement:
11 = 2 Form C (DPDT)
17 = 4 Form C (4PDT)
4. Operating Coil:
A = AC
D = DC
5. Mounting and Termination:
Relay Type
E
F
S
U
X
Available Codes
1
1
1, 2,
3, 4
1, 3,
4, 9
1, 3,
4, 9
1 = Socket mount, solder terminals on S, U, X types; printed circuit terminals on E, F types.
2 = Mounting plate with stud on broad side, solder terminals.
3 = Mounting plate with stud on narrow side, solder terminals.
4 = Mounting plate with stud on dust cover end, solder terminals.
9 = Socket mount, without stud.
6. Contact Material:
Relay Type
Available Codes
E
F
S
U
X
1, 2, 3,
5, 6, 8
1, 2, 3,
5, 6, 8
1*, 2*,
3, 5,
1, 2, 3,
5, 6, 8
1, 2, 3,
5, 6, 8
*UL Rated 1/10 HP, 3A, 120VAC when used with mounting & termination 1.
1 = Silver.
2 = Silver-cadmium oxide.
3 = Gold-silver-nickel.
4 = Palladium.
5 = Silver alloy.
6 = Bifurcated crossbar, gold overlay silver.
8 = Gold diffused silver.
7. Options Available (None available with contact arrangement 20.):
Relay Type
E
F
Available Codes B (DPDT only)
B
S
None
U
X
N
B
H
L
M
N
B (DPDT only)
H (DPDT only)
B = Push to test button.
N = Neon indicator. Only available with 120VAC or 110VDC coils. Not available with mounting & termination 4 or 8.
H = Neon indicator and push to test button. Only available with 120VAC or DC coils. Not available with mounting & termination 4 or 8.
L = LED indicator. Only available with 6-48VDC coils.
M = LED indicator and push-to-test button. Only available with 6-48VDC coils.
8. Coil Voltage:
6, 12, 24, 48, 120, 240**VAC
6, 12, 24, 48, 90, 110, 120VDC
**240VAC coil is not available on KHS type relays.
Note 1: All KHA models available in KH construction. Specify KH instead of KHA.
Stock Items - The following items are normally maintained in stock for immediate delivery.
KHAE-17D12-24
KHAU-11A11-120
KHAU-11D11-24
KHAU-17A11-12
KHAU-17A11-24
KHAU-17A11-120
KHAU-17A11N-120
KHAU-17A12-120
KHAU-17A13-120
KHAU-17A16-24
KHAU-17A16-120
KHAU-17A18-120
KHAU-17D11-6
KHAU-17D11-12
KHAU-17D11-24
KHAU-17D11-48
KHAU-17D11-110
KHAU-17D12-12
KHAU-17D12-24
KHAU-17D12-48
KHAU-17D12-110
KHAU-17D13-24
KHAU-17D16-12
KHAU-17D16-24
KHS-17A11-24
KHS-17A11-120
KHS-17A12-120
KHS-17A13-120
KHS-17D11-12
KHS-17D11-24
KHS-17D11-48
KHS-17D11-110
KHS-17D12-12
KHS-17D12-24
KHS-17D13-24
KHU-17A11-12
KHU-17A11-24
KHU-17A11-120
KHU-17A11N-120
KHU-17A12-120
KHU-17A13-120
KHU-17A16-120
KHU-17A18-120
KHU-17D11-5
KHU-17D11-6
KHU-17D11-12
KHU-17D11-24
KHU-17D11-48
KHU-17D11-110
KHU-17D12-12
KHU-17D12-24
KHU-17D16-24
KHU-17D18-24
B
-24
Outline Dimensions
Mounting Code 1 - KHAU and KHAX only.
Mounting Code 1 - KHS only.
2 & 4 Pole
2 & 4 Pole
.859 MAX.
(21.82)
.750
(19.05)
.25
(6.4)
#3-48
THREAD
1 2 3
5 6 7
.022
(.56)
4
8
.312
(7.92)
.022 REF
(.56)
9 10 11 12 1.109 MAX.
(28.17)
.168
(4.27)
.000 - .010
(.00 - .25)
1.281 MAX.
(32.54)
.265
(6.73)
.263
(6.68)
.525
(13.34)
1.281 MAX.
(32.54)
.421
(10.69)
Class 1 Div. 2 Group A, B, C & D Hazards
Mounting Code 1 - Neon Indicator, Push-To-Test.
.040 ± .010
(1.02 ± .25)
#3-48 THREAD
.265 ± .046
(6.73 ± 1.17)
.219
(5.56)
1.281 MAX.
(32.54)
1.600 MAX WITH
INDICATOR LAMP
(38.10)
.313
(7.95)
1 2 3
5 6 7
9 10 11 12
.263
(6.68)
.312 ± .031
(7.92 ± .79)
.180 DIA. BOSSES
(4.57)
(Special Order)
.168
(4.27)
.052 REF.
(1.32)
.421 ± .046
(10.69 ± 1.17)
.050 DIA.
TYPICAL
(1.27)
.112
(2.84)
.047
REF.
(1.19)
.15
(3.81)
Printed circuit terminal thickness .022 (.558)
.200 (5.08) terminal length available on special order
Mounting
Code 4
Recommended Chassis Cutout
For Stud Mount
.375 REF.
(9.53)
.156
(3.96)
KHS Printed Circuit
Terminals
.168 ± 020
(4.27 ± .51)
.525
(13.34)
Mounting
Code 3
Mounting Code 2 - Stud On Broad Side.
4
8
Printed Circuit
Terminals
1.109 MAX.
(28.17)
.250
(6.35)
.859 MAX.
(21.82)
.750
(19.05)
.022 ± .015
(.56 ± .38)
.125 DIA.
(3.18)
.263 REF.
(6.68)
.281 REF.
(7.14) .525 REF.
(13.34)
.312 + .031
(7.92 ± .79)
.45 REF.
(11.4)
1.156 MAX.
(29.36)
#3-48 THREAD
PC terminal models have rivet, not stud.
Max. seated height in 27E006 socket is
1.37" (34.8mm).
.797 ± .020
(20.24 ± .51)
.910 MAX.
(23.11)
.250 + .015
(6.35 ± .38)
2 & 4 Pole
.770
(19.56)
.437
(11.10)
.660
(16.76)
.158
(4.01)
.547
(13.89)
.645
(16.38)
#6-32
THREAD
.085 MAX.
(2.16)
Stud On
Narrow Side
1
5
9
4 Pole
1
5
9
4
8
12
13
+
Stud On
End
.263
(6.68)
.525
(13.34)
PC Board Layout (Bottom View)
Wiring Diagrams (Bottom Views)
2 Pole
.022
(.56)
.201 DIA
(5.11)
2 HOLES
.130 DIA.
(3.30)
14
-
2
6
10
3
7
11
13
14
+
-
+ = Polarity for LED indicator or diode suppression if ordered special.
Siemens Electromechanical Components, Inc.
Potter & Brumfield Products Division
200 S. Richland Creek Drive
Princeton, IN 47671-0001
.160
(4.06)
4
8
12
.410
(10.41)
.660
(16.76)
14
PLACES
.070 DIA.
(1.78)
.175
(4.45)
.525
(13.34)
For KHAE, KHAF Relays
with PC terminals
and sockets with
PC terminals
.350
(8.89)
Specifications and availability subject to change without notice.
13CXXXX
Printed in U.S.A.
PX/X-XX
Sockets For KHA And KHS Series
All sockets are normally maintained in stock for immediate delivery.
4-Pole Socket
For KHAU, KHAX, KHS Relays.
Relays wilth solder terminals are required for use with sockets.
.068
(1.73)
Socket Description
Industrial
Part No.
No. of
Poles
Terminal
and Length
Grounding
Provision
Socket
Material
27E006*
4
Yes
Nylon
27E007*
4
Yes
Nylon
27E023*
4
No
Nylon
No
27E166**
4
Solder .375"
(9.53mm)
P.C. .218"
(5.54mm)
P.C. .218"
(5.54mm)
Screw
27E894**
4
Screw
20C217
20C297
Yes
1.150
(29.21)
.850
(21.59)
Glass-filled
Polyester
Glass-filled
Polyester
Relay Hold Down Spring
Relay Hold Down Spring
(use with 27E166 &
27E894)
1.07
(2.72)
.012
(0.30)
.310
(7.87)
.440
(11.18)
Recommended Chassis Cutouts
For Mounting Sockets
.858
(21.79)
* UL Recognized, file E22575
** UL Recognized, file E59244
Recommended Chassis Thickness
.031 (.79) to .062 (1.57)
Pierced Solder Terminals
1.015
(25.78)
Mounting Strip 37D633
.629
(15.98)
.25
(6.4)
.125 ± .010
(3.18 ± 0.25)
GROUND
LUG
.105
(2.67)
.183
(4.65)
1.323
(33.60)
1.388
(35.26)
1.388
(35.26)
.090 R.
(2.29)
.617
(15.67)
Printed Circuit Terminals
With Grounding Lug
1.750
(44.45) 1.015
(25.78)
.171
(4.34)
.090
(2.29)
.052 ± .010
(1.32 ± 0.25)
.429
(10.90)
Socket punch Greenlee part
5015115.0, Type 731R available
from Greenlee Tool Co.,
Rockford, Illinois. (4-pole)
.218 ± .016
(5.54 ± 0.41)
.16
.180
(4.1) (4.57)
.065 .32
(1.65) (8.1)
.858
(21.79)
.13
(3.3)
.061
(1.55)
GROUND
LUG
Without Grounding Lug
37D633 will mount eight solder terminal sockets
in one length of aluminum strip measuring 10.97" x 2.25" x .062
(278.6 x 57.15 x 1.57)
Screw Terminal Socket 27E166
Relays with solder terminals are required for use
with screw terminal sockets.
.47
(11.93)
.94 .800 MAX.
(23.88) (20.32)
.140 TYP.
(3.56)
1.181
(30.00)
1.22 MAX.
(30.99)
M3 SCREWS &
CAPTIVE WASHERS
.709
(18.01)
27E166
Terminal
Location
8
4
14
1.771
(44.98)
2.441
(62.00)
.210 TYP.
(5.33)
.600
(15.24)
.236
(5.99)
.165
(4.19)
# 4-40 SCREWS &
CAPTIVE WASHERS
7
G
12 11 10
.118
(3.00)
1.024
(26.01)
27E894
Terminal
Location
6
3 2
5
1
.061
(1.55)
(Use with mounting track 24A110)
1.18
(30.0)
2.363 MAX.
(60.02)
.218 ± .016
(5.54 ± 0.41)
Screw Terminal DIN Rail,
Snap-Mount Socket 27E894
.446 REF.
(11.33)
8 7
43
6 5
21
14
13
.171
(4.34)
.984
(24.99)
.728
(18.49)
Caution: Printed circuit sockets are manufactured with
"floating" (Loose) terminals. This permits them to align
with holes in the circuit board and with the relay terminals.
During the mounting and soldering of the socket, vertical
float should be eliminated and the terminals seated on the
board. (This may be accomplished by inserting a dummy
relay in the socket.) Failure to eliminate float may cause
fracture of the solder joint or separation of the copper
conductor from the printed circuit board when a relay is
inserted in the socket after soldering.
Hold Down
Spring 20C217
13
9
12
11 10
9
Top View
Siemens Electromechanical Components, Inc.
700 Westpark Drive
Peachtree City, GA 30269-1498
Specifications and availability subject to change without notice.
13C5420
Printed in U.S.A.
IH/10-98