KRPA, KRP, KA, KR series
5 to 10 Amp
General Purpose Relay
File E29244, E22575, E81558 (KR Hermetic)
File LR15734
KRPA
KRP
KA
Features
Initial Dielectric Strength
•
•
•
•
•
Between Open Contacts: 500V rms.
Between All Elements: 1,500V rms.
Industry standard octal-type termination for quick installation.
Contact arrangements from 1 Form C (SPDT) to 3 Form C (3PDT).
Indicator lamp and push-to-test options available on certain models.
The KRPA is the automated manufactured version of the KRP.
Hermetically sealed option available with KR UL recognized for Class I
Div. 2 Hazardous locations, Groups A, B, C, D.
Coil Data @ 25°C
Nominal Power
Contact Data @ 25°C
Arrangements: See Ordering Information Table.
Materials: Silver or silver-cadmium oxide, with or without gold flashing.
Expected Life: 10 million operations min., mechanical; 100,000
operations min. @ rated loads.
KA, KRP, KRPA
UL/CSA Contact Ratings @ 25°C
(Except KR)
Contact Code
Arrangement
Y
(Silver)
1, 2, 3 Poles
G&N
(Silver-Cad.
Oxide)
1, 2, 3 Poles
KR–E (Herm. Sealed)
Contact Code
Contact Rating
5A @ 120VAC
3A @ 240VAC
1/10HP @ 120VAC
1/6HP @ 240VAC
KRP
KRPA
KA
Arrangement
1, 2, 3 Poles
5A @ 120VAC
3A @ 240VAC
1/10HP @ 120VAC
1/6HP @ 240VAC
G&N
(Silver-Cad. Oxide)
1, 2, 3 Poles
10A @ 240VAC
1/6 HP @ 120VAC
Enclosed Models - 4VA
Enclosed Models - 3W
Open Models - 4VA
Open Models - 4W
Coil Data @ 25°C
DC
Coils
Contact Rating
Y
(Silver)
2VA
1.2W
2VA
125mW per movable arm
Duty Cycle: Continuous.
Initial Insulation Resistance: KRP, KRPA - 1000 Megohms, min.
KA - 100 Megohms, min.
10A @ 240VAC
1/2 HP @ 240VAC
1/3HP @ 120VAC
UL Contact Ratings @ 25°C
Class I, Div. 2, Hazardous Loc.
AC
DC
AC
DC
Maximum Power
AC
Coils
Nominal
Voltage
DC Resistance (Ω)
±10%
Nominal Coil
Current (mA)
6
12
24
48
110
220
6
12
24
120
240
32
120
472
1,800
10,000
188
100
51
26.6
11.5
Use 110V relay with 10,000 Ω 5W Resistor in series
6
24
85
2,250
9,110
335
168
84
17.5
8.75
Operate Data @ 25°C
KR–E (Herm. Sealed)
Contact Code
Arrangement
Y,G
(Silver)
KRP, KRPA
UL Contact Ratings @ 25°C
UL 508 Industrial Control
1, 2, 3 Poles
Contact Rating
3A @ 120VAC
3A @ 28VDC
1/10HP @ 120VAC
Factory Ratings
Contact Code
Arrangement
Contact Rating
Y
1, 2, 3 Poles
5A @ 28VDC, 120VAC, 80% PF
G&N
1, 2, 3 Poles
10A @ 28VDC, 120VAC, 80% PF
6A @ 250VAC
KA UL Contact Ratings
Contact Code
Must-Operate Voltage:
DC: 75% or less of nominal voltage.
AC: 85% or less of nominal voltage.
Operate Time (Excluding Bounce):
15 milliseconds typical @ nominal voltage.
Release Time (Excluding Bounce):
10 milliseconds typical @ nominal voltage.
Series
Environmental Data
Temperature Range:
Open Models: AC: -45°C to +70°C.
DC: -45°C to +85°C.
Enclosed Models: AC: -45°C to +55°C.
DC: -45°C to +70°C.
Contact Ratings
Y
KA1
5A @ 120VAC, 3A @ 240VAC,
1/10 HP @ 120VAC, 1/6 HP @ 240VAC
G
KA2
10A @ 120VAC, 6A @ 240VAC
1/6 HP @ 120VAC, 1/3 HP @ 240VAC
1Listed by C.S.A. for 5A @ 120VAC 80% PF
2Listed by C.S.A. for 10A @ 120VAC 80% PF
Note: See KRPA, KRP, KA, KR-E Ordering Information table on page 106.
Mechanical Data
Open Models: Solder terminals.
Enclosed Models: Octal-type plug.
Enclosures: Transparent polycarbonate (except KR).
Hermetically sealed metal case available with KR only.
Weight: KA: 1.7 oz. (48.2g) approximately.
KRPA, KRP: 3.0 oz. (85g) approximately.
Ordering Information
Typical Part No.
B
KRPA
-5
A
Y
1. Series:
KRPA (Newer version, enclosed)
KRP (Older version, enclosed)
KR (Hermetically sealed option ‘E’only)
KA (Open style)
2. Contact Arrangement:
5 = 1 Form C (SPDT)
11 = 2 Form C (DPDT)
14 = 3 Form C (3PDT)
3. Coil Input:
A = AC, 50/60 Hz.
D = DC
4. Contact Rating and Indicator Lamp Option:
TYPE
Codes
Available
KRPA
KRP
KR
KA
Y, G, N,
Y, G, N,
Y, G,
Y, G,
Leave Blank = Silver, no indicator lamp for hermetically sealed KR (option E below).
Y = Silver, no indicator lamp
G = Silver-cadmium oxide, no indicator lamp
N = Silver-cadmium oxide, with indicator lamp*
5. Options:
Leave Blank = No options (except KR).
E = Hermetically Sealed Option (KR only).
6. Coil Voltage:
Up to 240VAC
Up to 125VDC
*Indicator Lamp not available on 25-90V coils. Only 120-240VAC and 110VDC models are UL recognized and CSA certified.
Stock Items – The following items are normally maintained in stock for immediate delivery.
KA-5AG-120
KA-5AY-120
KA-5DG-6
KA-5DG-12
KA-5DG-110
KA-11AG-120
KA-11AY-6
KA-11AY-24
KA-11AY-120
KA-11DG-12
KA-11DG-24
KA-11DG-110
KA-14AG-120
KA-14AY-120
KA-14DG-24
KA-14DG-110
KR-11AE-120
KR-11AGE-120
KR-11DE-24
KR-11DGE-12
KR-11DGE-24
KR-14AGE-120
KR-14DGE-24
KRP-5AG-120
KRP-11AG-24
KRP-11AG-120
KRP-11AG-240
KRP-11AN-24
KRP-11AN-120
KRP-11AY-120
KRP-11DG-12
KRP-11DG-24
KRP-11DG-48
KRP-11DG-110
KRP-11DG-125
KRP-11DN-12
KRP-11DN-24
KRP-11DY-24
KRP-14AG-120
KRP-14AG-240
KRP-14AN-120
KRP-14AY-120
KRP-14DG-12
KRP-14DG-24
KRP-14DG-110
KRP-14DN-24
KRPA-5AG-24
KRPA-5AG-120
KRPA-5AY-120
KRPA-5DG-6
KRPA-5DG-12
KRPA-5DG-24
KRPA-5DY-12
KRPA-5DY-24
KRPA-11AG-6
KRPA-11AG-12
KRPA-11AG-24
KRPA-11AG-120
KRPA-11AG-240
KRPA-11AN-12
KRPA-11AN-24
KRPA-11AN-120
KRPA-11AN-240
KRPA-11AY-6
KRPA-11AY-12
KRPA-11AY-24
KRPA-11AY-120
KRPA-11AY-240
KRPA-11DG-6
KRPA-11DG-12
KRPA-11DG-24
KRPA-11DG-48
KRPA-11DG-110
KRPA-11DN-12
KRPA-11DN-24
KRPA-11DN-110
KRPA-11DY-12
KRPA-11DY-24
KRPA-14AG-12
KRPA-14AG-24
KRPA-14AG-120
KRPA-14AG-240
KRPA-14AN-24
KRPA-14AN-120
KRPA-14AN-240
KRPA-14AY-24
KRPA-14AY-120
KRPA-14AY-240
KRPA-14DG-12
KRPA-14DG-24
KRPA-14DG-48
KRPA-14DG-110
KRPA-14DN-24
KRPA-14DY-24
-120
KRP-3-H series
20 Amp
Small AC or DC Relays
File E22575
KRP-3-H
Features
Coil Data @ 25°C
• 1 Form X (SPST - NO - DM) contact rating of 20A.
• Heavy copper alloy movable contact arms.
• Twin silver-cadmium oxide contacts.
• Many uses in automation controls and other applications requiring high
current switching.
See chart on page 105.
Nominal Power: DC Coils: 1.2W
AC Coils: 2.0VA
Initial Insulation Resistance: 1,000 megohms.
Operate Data @ 25°C
Contact Data @ 25°C
Must-Operate Voltage: DC: 75% of nominal voltage.
AC: 85% of nominal voltage.
Operate Time: 15 milliseconds approximate (Excluding Bounce).
Release Time: 10 milliseconds approximate (Excluding Bounce).
Arrangement: 1 Form X (SPST - NO - DM).
Ratings: UL Rating: 20A @ 120VAC, 3/4 HP @ 120VAC.
Factory Rating: 20A @ 120VAC, 80% PF; 1 HP @
120/240VAC.
Material: Twin, silver-cadmium oxide.
Expected Life: 2.5 million operations min., mechanical. 100,000
operations at rated contact load.
Environmental Data
Temperature Range: Enclosed Models: AC: -45°C to +55°C.
DC: -45°C to +70°C.
Initial Dielectric Strength
Between Open Contacts: 500V rms, 60 Hz. between all elements.
Mechanical Data
Mounting: Socket mounting.
Termination: Octal-type plug.
Enclosure: Polycarbonate enclosure with octal-type mounting.
Weight: 2 oz. (57g) approximately.
Ordering Information
Typical Part No.
B
KR
1. Basic Series: KR
2. Type:
P = Enclosed
(20 amp models available only with Contact Arrangement 3 and Material H.)
3. Contact Arrangement:
3 = 1 Form X (SPST - NO - DM)
4. Coil Input:
A = AC
D = DC
5. Contact Material & Rating:
H = Silver-cadmium oxide, 1/4" (6.35mm) dia., 20 amps.
6. Coil Voltage:
To 240VAC, 50/60 Hz. or 110VDC.
Stock Items
KRP-3AH-120
KRP-3DH-24
KRP-5AG-120
P
-3
D
H
-12
Outline Dimensions
KA Series
1.375 MAX.
(34.93)
1.468 MAX.
(37.29)
.25
(6.4)
1.06 MAX.
.44
(26.9)
(11.2)
1.92 MAX.
(48.8)
1 STUD
#6-32
THREAD
.15
(3.8)
.312
(7.92)
Tolerances on .XX Decimals ± .02 (± .5) Unless Otherwise Specified
Tolerances on .XXX Decimals ± .005 (± .13) Unless Otherwise Specified
KR Series Enclosures
Type “P” Clear Dust Cover
For KRPA and KRP
For KRP3-H
1.531 MAX.
(38.89)
1.406 MAX.
(35.71)
1.406 MAX.
(35.71)
2.0 MAX.
(50.8)
2.281 MAX.
(57.94)
1.406 MAX.
(35.71)
.031
(.79)
Hermetically Sealed Enclosure
Hold-Down Spring
(KR only)
20C176 KRPA & KRP
20C206 KAP and KRP3
Durable stainless steel
spring can be moved
aside for relay removal or
installation. Mounts with
same machine screws or
rivets that secure socket
to chassis. Two .156"
(3.96mm) dia. holes
required.
Octal Plug
1.656
(53.98)
1.437
(36.50)
Height: 2.125" (53.98mm) max.
Wiring Diagrams (Bottom Views)
KA
KR11
KAP11
KRP11
KRPA11
KR5
KAP5
KRP5
KRPA5
8
6
5
8
1
7
4
2
7
3
6
1
10
2
3
5
KR14*
KAP14
KRP14
KRPA14
4
11 1
KRP3AH
8
2
9
3
8
4
7
6
5
1
7
2
3
6
5
4
* The hermetically sealed KR14
has pins 5 and 6 reversed.
Sockets For KRP, KRPA Series Relays
The following sockets are normally maintained in stock for immediate delivery.
Screw Terminal, DIN Rail Snap-Mount Sockets
(Use with mounting track 24A110)
27E891
10A, 300VAC
Terminal
Location
Terminal
Location
27E892
10A, 300VAC
Top View
Top View
1.295
(32.89)
2
1
8
7
2.060
(52.32)
1
1.005
(25.53)
11
2
1.018
(25.84)
10
3
2.010
(51.05)
9
2.035
(51.69)
.165
(4.19)
DIA.TYP.
3
.312 TYP.
(7.92)
4
5
.165
(4.19)
DIA.TYP
6
.580
(14.73)
4
8
6
.312 TYP.
(7.92)
.580
(14.73)
2.332
(59.22)
1.575
(40.01)
7
5
.770
(19.56)
.970
(24.64)
.970
(24.64)
Sockets have M3.5 screw terminals which accept up to two #12 AWG
wires. Rated 10 amps @ 300VAC and meets UL 94V-0.
Screw Terminal Sockets
27E123
10A, 300VAC
11-pin
27E122
10A, 300VAC
8-pin
1.296
(32.92)
2.060
(52.32)
.648
(16.46)
1.030
(26.16)
.156 TYP.
(3.96)
.062
(1.57)
1.188
(30.18)
2.385 MAX.
(60.58)
.093
(2.36)
.781 ¢
(19.84)
.156 DIA. TYP.
(3.96)
.210 TYP.
(5.33)
1.572 MAX.
(39.93)
+
+
1.188
(30.18)
= 6-32 SCREWS &
CAPTIVE WASHERS
1.156
(29.36)
¢
= 6-32 SCREWS &
CAPTIVE WASHERS
¢
6
5
4
.925 MAX.
(23.50)
3
Terminal
Location
7
8
1
.210 TYP.
(5.33)
.093
(2.36)
2.322 MAX.
(58.98)
.925 MAX.
(23.50)
Terminal
Location
.062
(1.57)
.156 TYP.
(3.96)
2.385 MAX.
(60.58)
1.296
(32.92)
.648
(16.46)
8
7
6
5
4
2
3
2
9 10 11 1
Tyco Electronics Corporation - P&B, Winston-Salem, NC 27102
Technical Support Center: 1-800-522-6752, www.pandbrelays.com
Specifications and availability subject to change without notice.
13C5272
Printed in U.S.A.
IH/3-00