General Purpose Relays
Industrial Relays
Potter & Brumfield
KRP-3_H Series Panel Plug-in Relay
n
20 amp capability
Contact arrangement of 1 Form X (SPST - NO-DM)
n Heavy copper alloy movable contact arms
n Twin silver-cadmium oxide contacts
n
Typical applications
Automation controls, high current switching
U
Approvals
Insulation Data
UL E22575
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial insulation resistance
between insulated elements
Technical data of approved types on request
Contact Data
Contact arrangement
Rated voltage
Rated current
Contact material
Min. recommended contact load
Initial contact resistance
Frequency of operation
Operate/release time max.
Contacts ratings
Type
Load
UL 508
1 pole, AgCdO
20A, 120VAC
3/4HP, 120VAC
Mechanical endurance
Coil Data
Coil voltage range
Coil versions, DC coil
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
6
6
4.5
12
12
9.0
24
24
18.0
48
48
36.0
110
110
82.5
1 form X (NO-DM)
120VAC
20A
AgCdO
300mA, 12VDC
200mΩ
360 ops./hour
15/10ms
100MΩ at 500VDC
Other Data
Cycles
2.5x106 ops.
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
DC coil
-45ºC to 70ºC
AC coil
-45ºC to 55ºC
Category of environmental protection
IEC 61810
RTI - dust protected
Terminal type
Octal plug
Weight
57g
Packaging/unit tray/25 pcs., box/150pcs.
Accessories
6 to 110VDC
6 to 240VAC
Coil
resistance
Ω±10%
32
120
472
1800
10000
500Vrms
500Vrms
500Vrms
For details see datasheet
Rated coil
power
W
1.15
1.2
1.25
1.3
1.2
Sockets and Accessories, KRP Relays
Product Code Description
27E891
DIN socket (use 20C203 clip)
27E122
Track mount socket (use 20C203 clip)
All figures are given for coil without preenergization, at ambient temperature +23°C.
Coil versions, AC coil
Coil
Rated
Operate
code
voltage
voltage
VAC
VAC
6
6
5.1
12
12
10.2
24
24
20.4
120
120
102.0
240
240
204.0
Coil
resistance
Ω±15%
6
24
85
2250
9110
Rated coil
power
VA
2.01
2.02
2.02
2.1
2.1
All figures are given for coil without preenergization, at ambient temperature +23°C.
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
General Purpose Relays
Industrial Relays
Potter & Brumfield
KRP-3_H Series Panel Plug-in Relay (Continued)
Dimensions
Terminal assignment
1 Form X (1NO-DM)
8
1.406 MAX.
(35.71)
2.281 MAX.
(57.94)
1.531 MAX.
(38.89)
1
7
2
6
3
5
4
.031
(.79)
Product code structure
Typical product code
KRP-3 D
H
-12
Type
KRP-3 Enclosed panel plug-in relay with 1 Form X (1NO-DM) contacts
Coil Input
A AC
D DC
Contact material and rating
H AgCdO, 6.35mm (0.25") dia., rated 20A
Coil voltage
Coil code: please refer to coil versions table
Product Code
KRP-3AH-120
2
08-2011, Rev. 0811
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Arrangement
1 Form X
Material
AgCdO
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Coil
120 VAC
Terminals
Octal plug
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Part Number
1-1393102-1
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
很抱歉,暂时无法提供与“KRP-3DH-110”相匹配的价格&库存,您可以联系我们找货
免费人工找货