KILOVAC High Voltage DC Contactors
KILOVAC LEV200 Series Contactor With 1 Form X
Contacts Rated 500+ Amps, 12-900Vdc
Product Facts
Performance Data
n
Designed to be the lowest
cost sealed contactor in the
industry with its current
rating (500+A carry, 2000A
interrupt at 320Vdc)
n
Available with bottom or
side mounting — not
position sensitive
n
Optional auxiliary contact
for easy monitoring of
power contact position
n
Hermetically sealed —
intrinsically safe, operates
in explosive/harsh
environments with no
oxidation or contamination
of coils or contacts,
including long periods of
non-operation
n
Typical applications include
battery switching and
backup, DC voltage power
control, circuit protection
and safety
n
Versatile coil/power
connections
n
Designed and built in
accordance to AIAG QS9000
n
RoHS compliant
Coil Data (Valid Over Temperature Range) 4
12Vdc
24Vdc
Nominal Voltage
Pickup Voltage (Will Operate) 9.0Vdc
19.0Vdc
Voltage (Max.)
15Vdc
30Vdc
0.75 1.0 Dropout Voltage
5.0Vdc
2.0Vdc
Coil Resistance @ 25° (Typ.) 11 ohms 40 ohms
48Vdc
38.0Vdc
60Vdc
2.0 7.0Vdc
145 ohms
72Vdc
57.0Vdc
90Vdc
3.0 12.0Vdc
357 ohms
Ordering Information
LEV200 A 4 N A A
Typical Part Number 䊳
Series:
LEV200 = 500+ Amp, 12-900Vdc Contactor
Contact Form:
A = Normally Open
H = Normally Open with Aux. Contacts. (Option
“H” requires option “A” in Coil Wire Length
and option “N” in Coil Terminal Connector.)
Note: Other auxiliary contact forms available.
Consult factory.
Coil Voltage:
4 = 12Vdc 5 = 24Vdc B = 28Vdc
6 = 48Vdc K = 72Vdc
8 = 96Vdc L = 110Vdc O = 115Vac 9 = 240Vac
Notes: Consult factory for detailed specifications
and availability of coils not listed in
“Coil Data” table above. In coil voltage
codes, 115Vac is designated by the
letter “O” rather than the numeral “0.”
Coil Wire Length:
A = 15.3 in (390 mm)
N = None (Requires option
“A” in next step.)
Coil Terminal Connector:
N = None, stripped wires
(Requires option “A” in previous step.)
A = Studs, #10-32 Threaded (Electrical connection
is made to the tab at the base of the stud.)
Note: Specify option A, stripped wires, for coil voltages
> 96Vdc
For factory-direct application assistance,
dial 800-253-4560, ext. 2055, or
805-220-2055.
Mounting & Power Terminals:
A = Bottom Mount & Male 10mm x M8 Threaded Terminals
F = Side Mount & Male 10mm x M8 Threaded Terminals
Consult factory regarding other available mountings and
power terminals.
Contact Arrangement, Power
Contacts — 1 Form X (SPST-NO-DM)
Rated Operating Voltage —
12 - 900 VDC
Continuous (Carry) Current,
Typical — 500 A @ 65°C, 400 mcm
conductors
Consult TE for required conductors for
higher (500+ A) currents
Make/Break Current at Various
Voltages 1 — See graph next page
Break Current at 320VDC 1 —
2,000 A, 1 cycle 3
Contact Resistance, Typ.
(@200A) — 0.2 mohms
Load Life — See graph next page
Mechanical Life — 1 million cycles
Contact Arrangement, Auxiliary
Contacts — 1 Form A (SPST-NO)
Aux. Contact Current, Max. —
2A @ 30VDC / 3A @ 125VAC
Aux. Contact Current, Min. —
100mA @ 8V
Aux. Contact Resistance, Max. —
0.417 ohms @ 30VDC /
.150 ohms @ 125VAC
Operate Time @ 25°C —
Close (includes bounce), Typ. — 25 ms
Bounce (after close only), Max. — 7 ms
Release (includes arcing), Max @
2000A — 12 ms
Dielectric Withstanding Voltage —
2,200 Vrms @ sea level (leakage
很抱歉,暂时无法提供与“LEV200AKANA”相匹配的价格&库存,您可以联系我们找货