TE Circuit Protection, a pioneer of polymeric positive
temperature coefficient resettable devices, has developed
several material platforms to help protect battery
applications. Each of these material platforms offers
different performance characteristics, allowing the
engineer greater design flexibility. PolySwitch devices
for battery protection include SRP, LR4, VTP, VLP, VLR
and MXP series, disc, and special application strap
devices.
Benefits
PolySwitch Resettable Devices – Strap Battery Devices
PolySwitch Resettable Devices
Strap Battery Devices
Features
• Many material platforms and device form factors
give engineers more design flexibility
• RoHS compliant
• Compatible with high-volume electronics assembly
• Broad range of resettable devices available
• Assists in meeting regulatory requirements
• Current ratings from 1.1A to 13A
• Low resistance devices increase battery operating
time
• Voltage ratings from 6V to 30V
• Lead free versions of all devices are available
• Agency recognition, UL, CSA, TÜV
• Fast time-to-trip
• Low resistance
Applications
• Mobile phone and smart phone battery packs
• Digital camera battery packs
• Tablet PC battery packs
• Portable media player battery packs
• Mobile radio battery packs
• Power tools (charge line)
12
• Computer battery packs
199
Application Selection Guide for Strap Battery Devices
The guide below lists PolySwitch strap battery devices which are typically used in these applications.
The following pages contain the specifications for the part numbers recommended below.
Once a device is selected, the user should evaluate and test each product for its intended application.
PolySwitch Resettable Devices — Key Device Selection Criteria
Protection Application
Additional Comments
Installation Method
Lowest Resistance
Mobile phone battery packs
Li-ion
Surface Mount
refer to Surface-mount section of this catalog
Lowest Thermal Cut-off
Prismatic
MXP370BD
VLR175F
Cordless phone battery packs
NiMH
Cylindrical
VLP210F
––
Mobile radio battery packs
NiMH
Cylindrical
LR4-380F
SRP175F
––
SRP350F
Computer battery packs
NiMH
Cylindrical
LR4-900F
––
Li-ion
Cylindrical
LR4-1300SSF
––
Prismatic
Consult local Rep
Consult local Rep
Camcorder battery packs
NiMH or Li-ion
Prismatic
VLP270F
VTP210GF
LR4-380F
––
PDA battery packs
Li-ion
Prismatic
VLP220F
VLR175F
Power tools (charge line)
NiCd, NiMH or Li-ion
Cylindrical
custom LR4
custom VTP
Table B1
Product Series - Current Rating, Voltage Rating / Typical Resistance for
Strap Battery Devices
VLR
Hold
Current (A)
MXP
SRP
LR4
85°C
90°C
90°C
120°C
125°C
125°C
—
—
16V/0.054Ω
—
—
—
1.20
—
16V/0.053Ω
—
—
15V/0.123Ω
—
—
—
—
1.70
12V/0.025Ω
—
16V/0.041Ω
1.75
12V/0.024Ω
16V/0.040Ω
16V/0.040Ω
—
15V/0.070Ω
—
—
—
6V/0.010Ω
—
15V/0.056Ω
1.90
—
2.00
—
—
—
—
30V/0.045Ω
—
2.10
—
16V/0.024Ω
16V/0.024Ω
—
—
—
—
16V/0.023Ω
—
—
—
—
—
—
—
—
—
—
—
—
15V/0.031Ω
2.30
200
VTP
1.10
2.20
12
VLP
Typical Activation Temperature
12V/0.015Ω
2.60
—
—
2.70
—
16V/0.015Ω
—
—
—
—
3.50
—
—
—
—
30V/0.024Ω
—
3.70
—
—
—
6V/0.013Ω
—
—
3.80
—
—
—
—
—
15V/0.020Ω
4.20
—
—
—
—
30V/0.018Ω
—
4.50
—
—
—
—
—
20V/0.016Ω
5.50
—
—
—
—
—
20V/0.013Ω
6.00
—
—
—
—
—
20V/0.011Ω
7.30
—
—
—
—
—
20V/0.009Ω
9.00
—
—
—
—
—
20V/0.008Ω
13.00
—
—
—
—
—
20V/0.006Ω
RoHS Compliant, ELV Compliant
Part Number
Thermal Derating for Strap Battery Devices
[Hold Current (A) at Ambient Temperature (°C)]
Maximum Ambient Temperature
-40°C
-20°C
0°C
20°C
Amps
25°C
40°C
50°C
60°C
70°C
80°C
85°C
85°C Typical Activation
VLR*
VLR170F
3.5
2.9
2.4
1.84
1.70
1.2
1.0
0.7
0.3
—
—
VLR170LF
3.5
2.9
2.4
1.84
1.70
1.2
1.0
0.7
0.3
—
—
VLR170UF
3.5
2.9
2.4
1.84
1.70
1.2
1.0
0.7
0.3
—
—
VLR175F
3.5
2.9
2.4
1.87
1.75
1.3
1.0
0.8
0.3
—
—
VLR175LF
3.5
2.9
2.4
1.87
1.75
1.3
1.0
0.8
0.3
—
—
VLR175UF
3.5
2.9
2.4
1.87
1.75
1.3
1.0
0.8
0.3
—
—
VLR230F
5.0
4.2
3.4
2.52
2.30
1.7
1.3
0.9
0.4
—
—
VLP120UF
2.4
2.1
1.8
1.30
1.20
1.0
0.7
0.6
0.3
0.2
0.1
VLP175UF
3.2
2.7
2.3
1.70
1.75
1.2
1.0
0.8
0.5
0.2
0.1
VLP210F
4.3
3.6
2.9
2.31
2.10
1.6
1.3
1.0
0.6
0.3
0.1
VLP220F
4.5
3.8
3.0
2.45
2.20
1.7
1.4
1.1
0.7
0.3
0.1
VLP270F
5.6
4.7
4.0
3.05
2.70
2.2
1.7
1.4
0.9
0.4
0.1
VTP110F
2.0
1.7
1.4
1.12
1.10
0.85
0.75
0.7
0.4
0.2
0.1
VTP170F
3.2
2.7
2.2
1.80
1.70
1.3
1.0
0.8
0.5
0.3
0.1
VTP170SSF
3.2
2.7
2.2
1.80
1.70
1.3
1.0
0.8
0.5
0.3
0.1
VTP170XF
3.2
2.7
2.2
1.80
1.70
1.3
1.0
0.8
0.5
0.3
0.1
VTP170XSF
3.2
2.7
2.2
1.80
1.70
1.3
1.0
0.8
0.5
0.3
0.1
VTP175F
3.2
2.7
2.2
1.84
1.75
1.3
1.0
0.8
0.5
0.3
0.1
VTP175LF
3.2
2.7
2.2
1.84
1.75
1.3
1.0
0.8
0.5
0.3
0.1
VTP210GF
4.1
3.5
2.9
2.26
2.10
1.6
1.3
1.0
0.7
0.4
0.1
VTP210SF
4.1
3.5
2.9
2.26
2.10
1.6
1.3
1.0
0.7
0.4
0.1
90°C Typical Activation
VLP*
VTP*
PolySwitch Resettable Devices – Strap Battery Devices
Table B2
120°C Typical Activation
MXP*
MXP190BB
—
—
2.6
—
1.90
—
—
0.85
—
—
—
MXP370BD
—
—
5.0
—
3.70
—
—
1.90
—
—
—
125°C Typical Activation
SRP
SRP120F
1.9
1.7
1.5
1.20
1.17
1.0
0.9
0.8
0.6
0.5
0.4
SRP120LF
1.9
1.7
1.5
1.20
1.17
1.0
0.9
0.8
0.6
0.5
0.4
SRP120SF
1.9
1.7
1.5
1.20
1.17
1.0
0.9
0.8
0.6
0.5
0.4
SRP175F
2.5
2.2
2.0
1.75
1.68
1.4
1.3
1.2
1.0
0.9
0.8
SRP175LF
2.5
2.2
2.0
1.75
1.68
1.4
1.3
1.2
1.0
0.9
0.8
SRP175SF
2.5
2.2
2.0
1.75
1.68
1.4
1.3
1.2
1.0
0.9
0.8
SRP200F
3.1
2.8
2.5
2.00
1.97
1.7
1.5
1.4
1.2
1.0
0.9
SRP350F
5.3
4.8
4.3
3.50
3.44
3.0
2.7
2.5
2.1
1.8
1.7
SRP420F
6.3
5.7
5.1
4.20
4.11
3.6
3.3
3.0
2.6
2.2
2.1
LR4-190F
2.8
2.5
2.3
1.9
1.86
1.6
1.5
1.4
1.2
1.1
1.0
LR4-260F
3.8
3.4
3.1
2.6
2.54
2.2
2.0
1.9
1.7
1.4
1.3
LR4-260SF
3.8
3.4
3.1
2.6
2.54
2.2
2.0
1.9
1.7
1.4
1.3
LR4-380F
5.4
4.9
4.4
3.8
3.64
3.3
3.0
2.8
2.5
2.3
2.1
LR4-380XF
5.4
4.9
4.4
3.8
3.64
3.3
3.0
2.8
2.5
2.3
2.1
LR4-450F
6.5
5.8
5.3
4.5
4.38
3.9
3.6
3.3
2.9
2.6
2.4
LR4-550F
7.6
6.9
6.2
5.5
5.32
4.7
4.3
4.0
3.6
3.2
3.0
LR4-600F
8.7
7.8
7.1
6.0
5.86
5.2
4.7
4.4
3.9
3.4
3.2
LR4-600XF
8.7
7.8
7.1
6.0
5.86
5.2
4.7
4.4
3.9
3.4
3.2
LR4-730F
10.5
9.5
8.6
7.3
7.13
6.3
5.7
5.4
4.7
4.2
4.0
LR4-900F
12.7
11.4
10.0
9.0
8.50
7.5
6.8
6.2
5.5
4.9
4.5
LR4-1300SSF
17.9
16.2
14.5
13.0
12.40
11.1
10.3
9.5
8.6
7.7
7.2
LR4
12
* Product electrical characteristics determined at 25°C.
RoHS Compliant, ELV Compliant
201
Figure B1 Thermal Derating Curve for Strap Battery Devices
=
=
=
=
Figure B1
LR4
SRP
VTP, VLP, MXP
VLR
200
D
C
180
% of Rated Hold and Trip Current
A
B
C
D
160
B
A
140
120
100
80
60
A
B
40
20
0
-50
C
-40
-30
-20
-10
0
10
20
30
40
50
60
70
80
D
90
Temperature (˚C)
Table B3 Electrical Characteristics for Strap Battery Devices
IH
(A)
IT
(A)
VMAX
(VDC)
IMAX
(A)
PD MAX
(W)
RMIN
(Ω)
RMAX
(Ω)
R1MAX
(Ω)
Figure for
Dimensions
VLR170F
1.70
4.1
12
100
1.4
8.50
VLR170LF
1.70
4.1
12
100
1.4
8.50
5.0
0.018
0.032
0.064
B3
5.0
0.018
0.032
0.064
VLR170UF
1.70
4.1
12
100
1.4
B3
8.50
5.0
0.018
0.032
0.064
VLR175F
1.75
4.2
12
100
B5
1.4
8.75
5.0
0.017
0.031
0.062
VLR175LF
1.75
4.2
12
B3
100
1.4
8.75
5.0
0.017
0.031
0.062
VLR175UF
1.75
4.2
B3
12
100
1.4
8.75
5.0
0.017
0.031
0.062
VLR230F
2.30
B5
5.0
12
100
2.5
10.00
5.0
0.012
0.018
0.036
B3
VLP120UF
VLP175UF
1.20
3.6
16
60
1.6
7.00
5.0
0.039
0.067
0.134
B5
1.75
3.9
16
60
1.6
8.75
5.0
0.030
0.050
0.100
B5
VLP210F
2.10
5.0
16
60
1.8
10.50
5.0
0.018
0.030
0.060
B2
VLP220F
2.20
5.3
16
60
1.8
11.00
5.0
0.017
0.029
0.058
B3
VLP270F
2.70
6.5
16
60
2.5
13.50
5.0
0.012
0.018
0.036
B3
VTP110F
1.10
2.7
16
100
1.3
5.50
5.0
0.038
0.070
0.140
B5
VTP170F
1.70
3.4
16
100
1.4
8.50
5.0
0.030
0.052
0.105
B2
VTP170SSF
1.70
3.4
16
100
1.4
8.50
5.0
0.030
0.052
0.105
B7
VTP170XF
1.70
3.4
16
100
1.4
8.50
5.0
0.030
0.052
0.105
B3
VTP170XSF
1.70
3.4
16
100
1.4
8.50
5.0
0.030
0.052
0.105
B4
VTP175F
1.75
3.6
16
100
1.4
8.75
5.0
0.029
0.051
0.102
B3
VTP175LF
1.75
3.6
16
100
1.4
8.75
5.0
0.029
0.051
0.102
B3
VTP210GF
2.10
4.7
16
100
1.5
10.00
5.0
0.018
0.030
0.060
B3
VTP210SF
2.10
4.7
16
100
1.5
10.00
5.0
0.018
0.030
0.060
B4
MXP190BB
1.90
4.9
6
50
1.0
9.50
2.0
0.007
0.015
0.024
B12
MXP370BD
3.70
9.0
6
50
1.3
18.50
5.0
0.004
0.010
0.016
B12
Part
Number
Max. Time-to-trip
(A)
(s)
85°C Typical Activation
VLR*
90°C Typical Activation
VLP*
VTP*
12
120°C Typical Activation
MXP*
* Product electrical characteristics determined at 25°C.
202
RoHS Compliant, ELV Compliant
IH
(A)
IT
(A)
VMAX
(VDC)
IMAX
(A)
PD MAX
(W)
SRP120F
1.20
2.7
15
100
1.2
6.00
SRP120LF
1.20
2.7
15
100
1.2
6.00
SRP120SF
1.20
2.7
15
100
1.2
SRP175F
1.75
3.8
15
100
SRP175LF
1.75
3.8
15
SRP175SF
1.75
3.8
SRP200F
2.00
SRP350F
SRP420F
Cont’d
RMIN
(Ω)
RMAX
(Ω)
R1MAX
(Ω)
Figure for
Dimensions
5.0
0.085
0.160
0.220
B6
5.0
0.085
0.160
0.220
B6
6.00
5.0
0.085
0.160
0.220
B10
1.5
8.75
5.0
0.050
0.090
0.120
B6
100
1.5
8.75
5.0
0.050
0.090
0.120
B6
15
100
1.5
8.75
5.0
0.050
0.090
0.120
B10
4.4
30
100
1.9
10.00
4.0
0.030
0.060
0.100
B6
3.50
6.3
30
100
2.5
20.00
3.0
0.017
0.031
0.050
B6
4.20
7.6
30
100
2.9
20.00
6.0
0.012
0.024
0.040
B6
LR4-190F
1.90
3.9
15
100
1.2
9.5
5.0
0.0390
0.0720
0.102
B8
LR4-260F
2.60
5.8
15
100
2.5
13.0
5.0
0.0200
0.0420
0.063
B8
LR4-260SF
2.60
5.8
15
100
2.5
13.0
5.0
0.0200
0.0420
0.063
B9
LR4-380F
3.80
8.3
15
100
2.5
19.0
5.0
0.0130
0.0260
0.037
B8
LR4-380XF
3.80
8.3
15
100
2.5
19.0
5.0
0.0130
0.0260
0.037
B8
LR4-450F
4.50
8.9
20
100
2.3
22.5
5.0
0.0110
0.0200
0.028
B8
LR4-550F
5.50
10.5
20
100
2.8
27.5
5.0
0.0090
0.0160
0.022
B8
LR4-600F
6.00
11.7
20
100
2.8
30.0
5.0
0.0070
0.0140
0.019
B8
LR4-600XF
6.00
11.7
20
100
2.8
30.0
5.0
0.0075
0.0140
0.019
B8
LR4-730F
7.30
14.1
20
100
3.3
30.0
5.0
0.0060
0.0120
0.015
B8
LR4-900F
9.00
16.7
20
100
3.8
45.0
5.0
0.0060
0.0100
0.014
B8
13.00
21.2
20
100
4.5
50.0
10.0
0.0035
0.0065
0.009
B11
Part
Number
Max. Time-to-trip
(A)
(s)
125˚C Typical Activation
SRP
LR4
LR4-1300SSF
PolySwitch Resettable Devices – Strap Battery Devices
Table B3 Electrical Characteristics for Strap Battery Devices
* Product electrical characteristics determined at 25°C.
Notes:
IH
IT
VMAX
IMAX
PD
RMIN
RMAX
R1MAX
: Hold current: maximum current device will pass without interruption in 20°C still air unless otherwise specified.
: Trip current: minimum current that will switch the device from low resistance to high resistance in 20°C still air unless otherwise specified.
: Maximum voltage device can withstand without damage at rated current.
: Maximum fault current device can withstand without damage at rated voltage.
: Power dissipated from device when in the tripped state in 20°C still air unless otherwise specified.
: Minimum resistance of device as supplied at 20°C unless otherwise specified.
: Maximum resistance of device as supplied at 20°C unless otherwise specified.
: Maximum resistance, measured at 20°C unless otherwise specified, of device one hour after being tripped the first time.
Figure B2-B12 Dimension Figures for Strap Battery Devices
Figure B2
Figure B3
C
A
B
F
D
E
RoHS Compliant, ELV Compliant
Figure B4
C
A
B
F
D
E
12
C
A
B
F
D
E
203
Figure B2-B12 Dimension Figures for Strap Battery Devices
Figure B5
Cont’d
Figure B6
Figure B7
B
B
F
D
C
A
C
A
E
A
F
D
C
B
F
D
Figure B11
A
C
B
E
E
Figure B10
C
B
F
D
E
Figure B9
A
C
B
F
D
Figure B8
A
E
D
E
Figure B12
A
A
C
C
B
B
F
D
E
F
D
E
Table B4 Dimensions for Strap Battery Devices in Millimeters (Inches)
A
Part Number
85°C Typical Activation
VLR
VLR170F
12
B
Min.
Max.
20.8
23.2
(0.832) (0.928)
VLR170LF
38.8
41.2
(1.552) (1.648)
VLR170UF
20.8
23.2
(0.832) (0.928)
VLR175F
23.0
24.5
(0.920) (0.980)
VLR175LF
29.3
31.7
(1.172) (1.268)
VLR175UF
23.0
24.5
(0.920) (0.980)
VLR230F
20.9
23.1
(0.836) (0.924)
204
RoHS Compliant, ELV Compliant
C
D
Min.
Max.
Min.
3.5
3.9
—
0.8
—
(0.032)
(0.140) (0.156)
3.5
3.9
(0.140) (0.156)
3.5
3.7
(0.140) (0.148)
2.9
3.3
(0.116) (0.132)
2.9
3.3
(0.116) (0.132)
2.9
3.1
(0.116) (0.124)
4.9
5.3
(0.196) (0.212)
Max.
—
0.8
—
(0.032)
—
0.07
—
(0.003)
0.5
0.8
(0.020) (0.032)
—
0.8
—
(0.032)
—
0.7
—
(0.028)
—
0.8
—
(0.032)
E
Min.
Max.
4.5
6.5
(0.180) (0.260)
8.7
10.3
(0.348) (0.412)
5.3
6.7
(0.212) (0.268)
4.7
7.2
(0.188) (0.288)
5.2
6.8
(0.208) (0.272)
5.2
7.5
(0.208) (0.300)
4.1
5.8
(0.164) (0.232)
F
Min.
Max.
4.5
6.5
(0.180) (0.260)
18.7
20.3
(0.748) (0.812)
5.3
6.7
(0.212) (0.268)
3.8
5.4
(0.152) (0.216)
10
12.5
(0.400) (0.500)
4.3
5.7
(0.172) (0.228)
4.1
5.8
(0.164) (0.232)
Min.
2.4
Max.
Figure
2.6
B3
(0.096) (0.104)
2.4
2.6
B3
(0.096) (0.104)
2.4
2.6
B5
(0.096) (0.104)
2.4
2.6
B3
(0.096) (0.104)
2.4
2.6
B3
(0.096) (0.104)
2.4
2.6
B5
(0.096) (0.104)
3.9
4.1
(0.156) (0.164)
B3
A
Part Number
90°C Typical Activation
VLP
VLP120UF
B
Min.
Max.
10.9
11.8
(0.430) (0.460)
VLP175UF
19.0
21.0
(0.750) (0.830)
VLP210F
15.4
17.5
(0.616) (0.700)
VLP220F
21.1
23.3
(0.844) (0.932)
VLP270F
20.9
23.1
(0.836) (0.924)
C
D
Min.
Max.
Min.
4.4
4.6
—
0.7
—
(0.028)
(0.170) (0.180)
3.4
3.6
(0.130) (0.140)
6.9
7.3
(0.276) (0.292)
3.5
3.9
(0.140) (0.156)
4.9
5.3
(0.196) (0.212)
Max.
—
0.7
—
(0.030)
0.6
0.8
(0.024) (0.032)
0.6
0.8
(0.024) (0.032)
0.6
0.8
(0.024) (0.032)
E
Min.
Max.
5.5
6.5
(0.220) (0.260)
10.0
11.0
(0.390) (0.430)
4.0
6.2
(0.160) (0.248)
5.1
6.8
(0.204) (0.272)
4.1
Cont’d
5.8
(0.164) (0.232)
F
Min.
Max.
1.65
1.9
(0.065) (0.075)
2.5
3.5
(0.100) (0.140)
4.0
6.2
(0.160) (0.248)
5.1
6.8
(0.204) (0.272)
4.1
5.8
(0.164) (0.232)
Min.
2.3
Max.
Figure
2.5
B5
(0.091) (0.098)
2.9
3.1
B5
(0.110) (0.120)
3.9
4.1
B2
(0.156) (0.164)
2.9
3.1
B3
(0.116) (0.124)
3.9
4.1
B3
(0.156) (0.164)
VTP
VTP110F
23.6
25.6
(0.944) (1.024)
VTP170F
15.4
17.5
(0.616) (0.700)
VTP170SSF
15.4
17.5
(0.616) (0.700)
VTP170XF
20.9
22.9
(0.836) (0.916)
VTP170XSF
20.9
22.9
(0.836) (0.916)
VTP175F
21.2
23.2
(0.848) (0.928)
VTP175LF
25.8
28.2
(1.032) (1.128)
VTP210GF
20.9
23.1
(0.836) (0.924)
VTP210SF
20.9
23.1
(0.836) (0.924)
2.7
2.9
(0.108) (0.116)
7.0
7.4
(0.280) (0.296)
7.0
7.4
(0.280) (0.296)
4.9
5.3
(0.196) (0.212)
4.9
5.3
(0.196) (0.212)
3.5
3.9
(0.140) (0.156)
3.5
3.9
(0.140) (0.156)
4.9
5.3
(0.196) (0.212)
4.9
5.3
(0.196) (0.212)
—
0.7
—
(0.028)
0.5
0.8
(0.020) (0.032)
0.5
0.8
(0.020) (0.032)
0.5
0.8
(0.020) (0.032)
0.5
0.8
(0.020) (0.032)
—
0.8
—
(0.032)
—
0.8
—
(0.032)
—
0.8
—
(0.032)
0.6
0.8
(0.024) (0.032)
7.0
8.0
(0.280) (0.320)
4.0
6.2
(0.160) (0.248)
4.0
6.2
(0.160) (0.248)
6.0
8.6
(0.240) (0.344)
6.0
8.6
(0.240) (0.344)
4.6
6.6
(0.184) (0.264)
5.7
7.3
(0.228) (0.292)
4.1
5.8
(0.164) (0.232)
4.1
5.8
(0.164) (0.232)
7.0
8.0
(0.280) (0.320)
4.0
6.2
(0.160) (0.248)
4.0
6.2
(0.160) (0.248)
6.0
8.6
(0.240) (0.344)
6.0
8.6
(0.240) (0.344)
4.6
6.6
(0.184) (0.264)
8.7
10.3
(0.348) (0.412)
4.1
5.8
(0.164) (0.232)
4.1
5.8
(0.164) (0.232)
2.3
2.5
B5
(0.092) (0.100)
3.9
4.1
B2
(0.156) (0.164)
3.9
4.1
B7
(0.156) (0.164)
3.9
4.1
B3
(0.156) (0.164)
3.9
4.1
B4
(0.156) (0.164)
2.9
3.1
B3
PolySwitch Resettable Devices – Strap Battery Devices
Table B4 Dimensions for Strap Battery Devices in Millimeters (Inches)
(0.116) (0.124)
2.4
2.6
B3
(0.096) (0.104)
3.9
4.1
B3
(0.156) (0.164)
3.9
4.1
B4
(0.156) (0.164)
120°C Typical Activation
MXP
MXP190BB
9.2
10.8
(0.368) (0.432)
MXP370BD
10.5
11.3
(0.420) (0.452)
2.96
3.26
(0.118) (0.130)
2.96
3.26
(0.118) (0.130)
0.7
1.1
(0.028) (0.044)
0.7
1.1
(0.028) (0.044)
1.6
3.1
(0.064) (0.124)
1.6
3.1
(0.064) (0.124)
5.0
—
2.0
—
(0.200)
—
(0.080)
—
5.5
7.5
5.5
7.5
2.2
2.4
B12
(0.088) (0.096)
2.2
2.4
B12
(0.088) (0.096)
125°C Typical Activation
SRP
SRP120F
19.9
22.1
(0.796) (0.884)
SRP120LF
24.9
27.1
(0.996) (1.084)
SRP120SF
19.9
22.1
(0.796) (0.884)
SRP175F
20.9
23.1
(0.836) (0.924)
SRP175LF
29.9
32.1
(1.196) (1.284)
SRP175SF
20.9
23.1
(0.836) (0.924)
SRP200F
21.3
23.4
(0.852) (0.936)
SRP350F
28.4
31.8
(1.136) (1.272)
SRP420F
30.6
32.4
(1.224) (1.296)
RoHS Compliant, ELV Compliant
4.9
5.2
(0.196) (0.208)
4.9
5.2
(0.196) (0.208)
4.9
5.2
(0.196) (0.208)
4.9
5.2
(0.196) (0.208)
4.9
5.2
(0.196) (0.208)
4.9
5.2
(0.196) (0.208)
10.2
11.0
(0.408) (0.440)
13.0
13.5
(0.520) (0.540)
12.9
13.6
(0.516) (0.544)
0.6
1.0
(0.024) (0.040)
0.6
1.0
(0.024) (0.040)
0.6
1.0
(0.024) (0.040)
0.6
1.0
(0.024) (0.040)
0.6
1.0
(0.024) (0.040)
0.6
1.0
(0.024) (0.040)
0.5
1.1
(0.020) (0.044)
0.5
1.1
(0.020) (0.044)
0.5
1.1
(0.020) (0.044)
(0.220) (0.300)
5.5
7.5
(0.220) (0.300)
5.5
7.5
(0.220) (0.300)
4.1
5.5
(0.164) (0.220)
10.5
12.5
(0.420) (0.500)
4.1
5.5
(0.164) (0.220)
5.0
7.6
(0.200) (0.304)
6.3
8.9
(0.252) (0.356)
5.0
7.5
(0.200) (0.300)
(0.220) (0.300)
10.5
12.5
(0.420) (0.500)
5.5
7.5
(0.220) (0.300)
4.1
5.5
(0.164) (0.220)
5.5
7.5
(0.220) (0.300)
4.1
5.5
(0.164) (0.220)
5.0
7.6
(0.200) (0.304)
6.3
8.9
(0.252) (0.356)
5.0
7.5
(0.200) (0.300)
3.9
4.1
B6
(0.156) (0.164)
3.9
4.1
B6
(0.156) (0.164)
3.9
4.1
B10
(0.156) (0.164)
3.9
4.1
B6
12
(0.156) (0.164)
3.9
4.1
B6
(0.156) (0.164)
3.9
4.1
B10
(0.156) (0.164)
4.8
5.4
B6
(0.192) (0.216)
6.0
6.6
B6
(0.240) (0.264)
6.0
6.7
B6
(0.240) (0.268)
205
Table B4 Dimensions for Strap Battery Devices in Millimeters (Inches)
A
Part Number
B
Min.
Max.
19.9
22.1
C
Min.
Max.
4.9
5.5
D
Min.
Max.
0.6
1.0
Cont’d
E
Min.
Max.
5.5
7.5
F
Min.
Max.
5.5
7.5
Min.
Max.
Figure
4.1
B8
LR4
LR4-190F
(0.796) (0.884)
LR4-260F
20.9
23.1
(0.836) (0.924)
LR4-260SF
20.9
23.1
(0.836) (0.924)
LR4-380F
24.0
26.0
(0.960) (1.040)
LR4-380XF
32.2
35.8
(1.288) (1.432)
LR4-450F
24.0
26
(0.960) (1.040)
LR4-550F
35.0
37.0
(1.400) (1.480)
LR4-600F
24.0
26.0
(0.960) (1.040)
LR4-600XF
40.5
42.7
(1.620) (1.708)
LR4-730F
27.1
29.1
(1.084) (1.164)
LR4-900F
45.4
47.6
(1.816) (1.904)
LR4-1300SSF
61.5
66.5
(2.460) (2.660)
(0.196) (0.220)
4.9
5.5
0.6
(0.196) (0.220)
4.9
5.5
7.5
4.9
5.5
9.9
10.5
6.9
7.5
13.9
14.5
6.9
7.5
13.9
14.5
7.9
8.5
9.4
10.0
1.3
(0.036) (0.052)
0.9
(0.376) (0.400)
1.0
(0.024) (0.040)
0.9
(0.316) (0.340)
1.0
(0.024) (0.040)
0.6
(0.556) (0.580)
1.0
(0.024) (0.040)
0.6
(0.276) (0.300)
1.0
(0.024) (0.040)
0.6
(0.556) (0.580)
1.0
(0.024) (0.040)
0.6
(0.276) (0.300)
1.0
(0.024) (0.040)
0.6
(0.396) (0.420)
1.0
(0.024) (0.040)
0.6
(0.196) (0.220)
1.0
(0.024) (0.040)
0.6
(0.276) (0.300)
1.0
(0.024) (0.040)
0.6
(0.196) (0.220)
6.9
(0.024) (0.040)
1.3
(0.036) (0.052)
(0.220) (0.300)
4.1
5.5
(0.164) (0.220)
4.1
5.5
(0.164) (0.220)
4.1
5.5
(0.164) (0.220)
5.5
7.5
(0.220) (0.300)
5.3
6.7
(0.212) (0.268)
5.3
6.7
(0.212) (0.268)
4.1
5.5
(0.164) (0.220)
5.2
6.8
(0.208) (0.272)
4.1
5.5
(0.164) (0.220)
4.6
6.2
(0.184) (0.248)
5.0
7.5
(0.200) (0.300)
(0.220) (0.300)
4.1
5.5
(0.164) (0.220)
4.1
5.3
4.1
4.1
5.0
5.9
4.9
B8
4.1
B8
6.1
B8
5.1
B8
5.9
6.1
B8
(0.236) (0.244)
4.9
5.1
B8
(0.196) (0.204)
5.9
6.1
B8
(0.236) (0.244)
5.9
6.1
B8
(0.236) (0.244)
7.5
(0.200) (0.300)
5.1
(0.196) (0.204)
6.2
(0.184) (0.248)
B9
(0.236) (0.244)
5.5
(0.164) (0.220)
4.6
3.9
6.8
(0.208) (0.272)
4.1
(0.156) (0.164)
5.5
(0.164) (0.220)
5.2
4.9
6.7
(0.212) (0.268)
B8
(0.196) (0.204)
6.7
(0.212) (0.268)
5.3
3.9
7.5
(0.220) (0.300)
4.1
(0.156) (0.164)
5.5
(0.164) (0.220)
5.5
3.9
(0.156) (0.164)
5.5
(0.164) (0.220)
4.1
3.9
(0.156) (0.164)
5.9
6.1
B11
(0.236) (0.244)
Figure B13-B18 Typical Time-to-trip Curves at 20°C for Strap Battery Devices
VLR (data at 25°C)
A = VLR170F
B = VLR175F
C = VLR230F
Figure B13
100
C
10
12
Time-to-trip (s)
B
A
1
0.10
C
B
A
0.01
0.001
1
10
Fault Current (A)
206
RoHS Compliant, ELV Compliant
100
Figure B14
100
10
B
C
D
E
A
1
Time-to-trip (s)
VLP (data at 25°C)
A = VLP120UF
B = VLP175UF
C = VLP210F
D = VLP220F
E = VLP270F
Cont’d
0.10
0.01
E
D
C
0.001
B
A
0.0001
1
10
100
Fault Current (A)
VTP (data at 25°C)
A = VTP110F
B = VTP170F
C = VTP175F
D = VTP210GF
Figure B15
100
PolySwitch Resettable Devices – Strap Battery Devices
Figure B13-B18 Typical Time-to-trip Curves at 20°C for Strap Battery Devices
D
10
A
Time-to-trip (s)
C
B
1
0.10
0.01
B
D
A
C
0.001
1
10
100
Fault Current (A)
Figure B16
MXP (data at 25°C)
A = MXP190BB
B = MXP370BD
10
B
A
12
Typical Time-to-trip (s)
1
0.10
B
A
0.01
0.001
1
10
100
Fault Current (A)
RoHS Compliant, ELV Compliant
207
Figure B13-B18 Typical Time-to-trip Curves at 20°C for Strap Battery Devices
Figure B17
SRP120F
SRP175F
SRP200F
SRP350F
SRP420F
100
10
Typical Time-to-trip (s)
SRP
A =
B =
C =
D =
E =
Cont’d
C
D
E
B
A
1
0.10
C
D
E
B
A
0.01
1
10
100
Fault Current (A)
Figure B18
LR4-190F
LR4-260F
LR4-380F
LR4-450F
LR4-550F
LR4-600F
LR4-730F
LR4-900F
LR4-1300SSF
G
100
F
E
A
10
Typical Time-to-trip (s)
LR4
A =
B =
C =
D =
E =
F =
G =
H =
I =
B
C
H
I
D
G
F
E
D
C
1
I
H
B
A
0.10
0.01
1
10
100
Fault Current (A)
Table B5 Physical Characteristics and Environmental Specifications for Strap Battery Devices
12
VLR
Physical Characteristics
Lead material
Tape material
0.125mm nominal thickness, quarter-hard nickel
Polyester
Environmental Specifications
Test
Passive aging
Humidity aging
Thermal shock
Vibration
208
RoHS Compliant, ELV Compliant
Conditions
-40°C, 1000 hours
60°C, 1000 hours
60°C/95% RH, 1000 hours
85°C, -40°C (10 times)
MIL-STD-883D, Method 2026
Resistance Change
±5% typical
±20% typical
±30% typical
±5% typical
No change
Cont’d
VLP and VTP
Physical Characteristics
Lead material
Tape material
0.125mm nominal thickness, quarter-hard nickel
Polyester
Environmental Specifications
Test
Passive aging
Humidity aging
Thermal shock
Vibration
Conditions
-40°C, 1000 hours
60°C, 1000 hours
60°C/95% RH, 1000 hours
85°C, -40°C (10 times)
MIL-STD-883D, Method 2026
Resistance Change
±5% typical
±10% typical
±10% typical
±5% typical
No change
MXP
Physical Characteristics
Lead material
Coating material
0.1mm nominal thickness, half-hard nickel
Epoxy
Environmental Specifications
Test
Passive aging
Humidity aging
Thermal shock
Vibration
Conditions
-40°C, 1000 hours
60°C, 1000 hours
60°C/95% RH, 1000 hours
85°C, -40°C (10 times)
MIL-STD-883D, Method 2026
Resistance Change
±5% typical
±20% typical
±30% typical
±5% typical
No change
PolySwitch Resettable Devices – Strap Battery Devices
Table B5 Physical Characteristics and Environmental Specifications for Strap Battery Devices
SRP
Physical Characteristics
Lead material
Tape material
0.125mm nominal thickness, quarter-hard nickel
Polyester
Environmental Specifications
Test
Passive aging
Humidity aging
Vibration
Conditions
70°C, 1000 hours
85°C/85% RH, 7 days
MIL-STD-883C, Test Condition A
Resistance Change
±10% typical
±5% typical
No change
LR4
Physical Characteristics
Lead material
Tape material
12
0.125mm nominal thickness, quarter-hard nickel
Polyester
Environmental Specifications
Test
Passive aging
Humidity aging
Vibration
Conditions
70°C, 1000 hours
85°C/85% RH, 7 days
MIL-STD-883D, Method 2026
Resistance Change
±10% typical
±5% typical
No change
Note: Storage conditions: 40°C max., 70% RH max.; devices should remain in original sealed bags prior to use. Devices may not meet specified values if these storage conditions are exceeded.
RoHS Compliant, ELV Compliant
209
Table B6 Packaging and Marking Information/Agency Recognition for Strap Battery Devices
Bag
Quantity
Tape & Reel
Quantity
Standard Package
Quantity
Part Marking
Agency Recognition
VLR170F
1,000
—
10,000
R17
UL, CSA,TÜV
VLR170LF
1,000
—
10,000
R17
UL, CSA,TÜV
VLR170UF
1,000
—
10,000
—
UL, CSA,TÜV
VLR175F
1,000
—
10,000
R1X
UL, CSA,TÜV
VLR175LF
1,000
—
10,000
R1X
UL, CSA,TÜV
VLR175UF
1,000
—
10,000
—
UL, CSA,TÜV
VLR230F
1,000
—
10,000
R23
UL, CSA,TÜV
VLP120UF
1,000
—
10,000
—
UL, CSA, TÜV
VLP175UF
1,000
—
10,000
—
UL, CSA, TÜV
VLP210F
1,000
—
10,000
W21
UL, CSA, TÜV
VLP220F
1,000
—
10,000
W22
UL, CSA, TÜV
VLP270F
1,000
—
10,000
W27
UL, CSA, TÜV
VTP110F
1,000
—
10,000
—
UL, CSA, TÜV
VTP170F
1,000
—
10,000
V17
UL, CSA, TÜV
VTP170SSF
1,000
—
10,000
V17
UL, CSA, TÜV
VTP170XF
1,000
—
10,000
V17
UL, CSA, TÜV
VTP170XSF
1,000
—
10,000
V17
UL, CSA, TÜV
VTP175F
1,000
—
10,000
V1X
UL, CSA, TÜV
VTP175LF
1,000
—
10,000
V1X
UL, CSA, TÜV
VTP210GF
1,000
—
10,000
V21
UL, CSA, TÜV
VTP210SF
1,000
—
10,000
V21
UL, CSA, TÜV
MXP190BB
4,000
—
8,000
—
UL, CSA, TÜV
MXP370BD
2,000
—
4,000
—
UL, CSA, TÜV
SRP120F
1,000
—
10,000
120
UL, CSA, TÜV
SRP120LF
1,000
—
10,000
120
UL, CSA, TÜV
SRP120SF
2,000
—
10,000
120
UL, CSA, TÜV
SRP175F
2,000
—
10,000
175
UL, CSA, TÜV
SRP175LF
1,000
—
10,000
175
UL, CSA, TÜV
SRP175SF
2,000
—
10,000
175
UL, CSA, TÜV
SRP200F
1,000
—
10,000
200
UL, CSA, TÜV
SRP350F
500
—
10,000
350
UL, CSA, TÜV
SRP420F
500
—
10,000
420
UL, CSA, TÜV
LR4-190F
2,000
—
10,000
E19
UL, CSA, TÜV
LR4-260F
1,000
—
10,000
E26
UL, CSA, TÜV
LR4-260SF
1,000
—
10,000
E26
UL, CSA, TÜV
LR4-380F
1,000
—
10,000
E38
UL, CSA, TÜV
LR4-380XF
1,000
—
10,000
E38
UL, CSA, TÜV
LR4-450F
1,000
—
10,000
E45
UL, CSA, TÜV
LR4-550F
1,000
—
10,000
E55
UL, CSA, TÜV
LR4-600F
1,000
—
10,000
E60
UL, CSA, TÜV
LR4-600XF
1,000
—
10,000
E60
UL, CSA, TÜV
LR4-730F
1,000
—
10,000
E73
UL, CSA, TÜV
LR4-900F
500
—
10,000
E90
UL, CSA, TÜV
LR4-1300SSF
250
—
10,000
EX3
UL, CSA, TÜV
Part Number
85°C Typical Activation
VLR
90°C Typical Activation
VLP
VTP
120°C Typical Activation
MXP
125°C Typical Activation
SRP
LR4
12
210
RoHS Compliant, ELV Compliant
PolySwitch Resettable Devices – Strap Battery Devices
Agency Recognition for Strap Battery Devices
UL
CSA
TÜV
File # E74889
File # 78165C
Certificate number available on request
Installation Guidelines for the Strap Family
• PPTC devices operate by thermal expansion of the conductive polymer. If devices are placed under pressure or installed in spaces that
would prevent thermal expansion, they may not properly protect against damage caused by fault conditions. Designs must be selected in
such a manner that adequate space is maintained over the life of the product.
• Twisting, bending, or placing the PPTC device in tension will decrease the ability of the device to protect against damage caused by
electrical faults. No residual force should remain on device after installation. Mechanical damage to the PPTC device may affect device
performance and should be avoided.
• Chemical contamination of PPTC devices should be avoided. Certain greases, solvents, hydraulic fluids, fuels, industrial cleaning agents,
volatile components of adhesives, silicones, and electrolytes can have an adverse effect on device performance.
• PPTC strap devices are designed to be resistance welded to battery cells or to pack interconnect straps, yet some precautions must be
taken when doing so. In order for the PPTC device to exhibit its specified performance, weld placement should be a minimum of 2mm from
the edge of the PPTC device, weld splatter must not touch the PPTC device, and welding conditions must not heat the PPTC device above
its maximum operating temperature.
• PPTC strap devices are not designed for applications where reflow onto flex circuits or rigid circuit boards is required.
• The polyester tape on PPTC strap devices is intended for marking and identification purposes only, not for electrical insulation.
• The coating on MXP devices is intended to prevent oxidization/aging of the devices. Damaging the coating or causing the coating to
delaminate can have negative effects on device performance and should be avoided.
• MXP devices have small PPTC chip size and therefore have weaker peel strength between polymer and Ni-foil of the chip. Excessive
mechanical force to the device may cause delamination of Ni-foil from polymer.
Part Numbering System for Strap Battery Devices
VTP 210 SF
Modifier
B, BB = Modified resistance window
D
= Short leaded strap
F
= Lead-free version
G
= Global design (standard product)
L
= Long lead or leads
S
= Slit lead
SS
= Both leads slit
U
= Untaped
X
= Rotated chip
Hold Current Indicator
Product Series
12
Warning :
• Users should independently evaluate the suitability of and test each product selected for their own application.
• Operation beyond the maximum ratings or improper use may result in device damage and possible electrical arcing and flame.
• These devices are intended for protection against damage caused by occasional overcurrent or overtemperature fault conditions and should
not be used when repeated fault conditions or prolonged trip events are anticipated.
• Contamination of the PPTC material with certain silicone-based oils or some aggressive solvents can adversely impact the performance of the devices.
• Device performance can be impacted negatively if devices are handled in a manner inconsistent with recommended electronic, thermal, and
mechanical procedures for electronic components.
• PPTC devices are not recommended for installation in applications where the device is constrained such that its PTC properties are inhibited,
for example in rigid potting materials or in rigid housings, which lack adequate clearance to accommodate device expansion.
• Operation in circuits with a large inductance can generate a circuit voltage (Ldi/dt) above the rated voltage of the device.
RoHS Compliant, ELV Compliant