MEAS
M5600
Wireless Pressure Transducer
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
±0.25% Pressure Accuracy
±1.0% Total Error Band
±3°C Temperature Output Accuracy
-10°C to +60°C Compensating
Temperature
-20°C to +85°C Operating
Temperature
APPLICATIONS
Industrial Process Control and
Monitoring
Advanced HVAC Systems
Refrigeration Systems
Off-Road Vehicles
Digital 24-bit ADC output, I2C protocol
Ce compliant with a variety of pressure ports
Optional stainless-steel snubber
FCC certified
Gage, sealed, compound
Bluetooth® 4.0 wireless connection
Compact and battery powered [CR2050 OR CR2032]
Weatherproof (IP66/IP67)
Stainless steel and polycarbonate enclosure
IOS, Android™ and Windows® XP/7+ compatible
The modular M5600 wireless pressure transducer from our Microfused
line is enclosed in a stainless steel and polycarbonate housing. This
high accuracy, 24-bit ADC digital output wireless transducer eliminates
hard wiring and provides remote process control and monitoring via
Bluetooth® 4.0 Wireless Communication. This series is suitable for
measurement of liquid or gas pressure, even for difficult media such as
contaminated water, steam, and mildly corrosive fluids.
The wetted material of the pressure port is made of 316L stainless
steel and the transducer’s durability is excellent with no organics
exposed to the pressure media. The M5600 is weatherproof and
exceeds the latest heavy industrial CE requirements.
This product is geared to the OEM customer for mid to high volumes.
TE stands ready to provide a custom design of the M5600 where the
volume and application warrants. Additional configurations not listed
are available. Please inquire for further information.
Automotive Test Stands
Pumps and Compressors
Hydraulic/Pneumatic Systems
Agriculture Equipment
Energy Generation and Management
Pool/Spa Pump Monitoring
TE CONNECTIVITY SENSORS /// M5600
10/2021
Page 1
M5600
Wireless Pressure Transducer
STANDARD RANGES
Range (psi)
0 to 050
0 to 100
0 to 200
0 to 300
0 to 500
0 to 01k
0 to 03k
0 to 05k
0 to 10k
0 to 15k
Range (Bar)
0 to 3.5
0 to 007
0 to 010
0 to 020
0 to 035
0 to 070
0 to 200
0 to 350
0 to 700
0 to 01k
Gage
Sealed
Compound
Intermediate ranges available upon request.
Sealed and absolute type are recommended for high humidity environments.
PERFORMANCE SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified) For custom configurations, consult factory.
Parameters
Min
Typ
Max
Units
Supply Voltage
2.3
Accuracy
-0.25
Temperature Output Accuracy
-3
3
Notes
3.6
VDC
Replaceable CR2032/CR2050
battery
0.25
%F.S.
RSS of linearity, hysteresis, and
repeatability
3
°C
Only for reference
Digital I2C
Output Protocol
Resolution
24
Endurance
1.00E+6
Stability
-0.25
Bit
0~FS Cycles
0.25
%F.S./year
Total Error Band
-1
1
%F.S.
Proof Pressure
2X
20k psi
Rated
Burst Pressure
5X
20k psi
Rated
Compensated Temperature
-10
+60
°C
-20
+85
°C
with CR2050 battery
-20
60
°C
With CR2032 battery
-40
+120
°C
without battery
Operating Temperature
Storage Temperature
Wireless Protocol
Receiver Operating System
Signal Pairing Distance
Signal Transmission Distance
Battery Life
Low Battery Warning
Weatherproof
Pressure Port Material
Enclosure
Shock
@25°C over compensated range
Bluetooth® 4.0 Wireless Connection or above
Android™ 4.3 or above, iOS 7 or above, Windows® XP/7 or above
65 feet
65 feet affected by receiver antenna and blocking objects
2-years typical CR2050 350mAH battery, 1-year typical CR2032 210mAH battery; 5 second
transmission interval
2.5VDC, red battery symbol in app
IP66 & IP67
17-4P Stainless Steel Port, 316L Stainless Steel Snubber
Stainless Steel and Polycarbonate
50g, 11msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A
Vibration
±20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L
Note:
Battery life depends on its capacity, operating temperature and signal transmission interval.
Sony Battery CR2050W or CR2032W offers high operating temperature up to 125ºC.
Temperature can impact battery capacity retention even in idle. Check battery specifications for more details.
Factory default data transmission rate is 5sec, which can be adjusted from 100msec to 5sec in smartphone app or PC software.
TE CONNECTIVITY SENSORS /// M5600
10/2021
Page 2
M5600
Wireless Pressure Transducer
Compliances
EN 55022 Emissions Class A & B
IEC 61000-4-2 Electrostatic Discharge Immunity (4kV contact/8kV air)
IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic Field Immunity (10V/m, 80M-1GHz); deviation
很抱歉,暂时无法提供与“M5600-00000E-020BG”相匹配的价格&库存,您可以联系我们找货
免费人工找货