PE0SXDS3A

PE0SXDS3A

  • 厂商:

    HUMIREL(泰科)

  • 封装:

  • 描述:

    CORCOM - TE CONNECTIVITY - PE0SXDS3A - Filtered IEC Power Entry Module, IEC C14, Medical, 3 A, 250 V...

  • 数据手册
  • 价格&库存
PE0SXDS3A 数据手册
CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications P Series UL Recognized CSA Certified VDE Approved PS Unfiltered PS000SS30 PS Filtered The P series power entry module offers fuller flexibility of design in a more compact package. H models provide susceptibility protection without leakage current associated with line-to-ground capacitors and are designed to allow equipment to meet UL 544 for patient care and non-patient care equipment. As the first 10 amp module to provide all five power entry functions in one compact design, the CHAMELEON module readily adapts to its environment and the needs of international markets. Also available is an interconnection block, B models. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with a switch and and IEC connector to reduce external wiring. • Snap-in or flange mounting L Models – High performance medical filter versions that are designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC part 15J, Class B) conducted emissions limits while additionally allowing equipment to meet UL544, UL2601and EN60601 for patient care equipment and non-patient care equipment. They are available with current ratings of 6 and 10 amps. High performance versions are available with horizontal mounting ears, single voltage, complete can shield with options for switch, fuses and current ratings only. Extenders are not available. P Series • IEC power line connector • Both North American and European fusing capabilities • Two voltage selections • Optional DPST on/off switch • Filtering options for general purpose, medical and high-performance applications. The CHAMELEON modules compact design and modular construction will allow you to select the power entry features you require — without altering the panel cutout. And the Chameleon module, with adapters, will fit any standard panel cutout. The CHAMELEON module has four filter options. S models offer protection for general purpose applications where line-to-ground and line-to-line noise must be controlled. The filters are designed to meet low leakage requirements of VDE portable equipment. They are available in current ratings of 3, 6 and 10 amps. Z Models – High performance filter versions are designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10 amps. High performance versions are available with horizontal mounting ears, no extenders, single voltage, complete can shield with options for switch, fuses and current ratings only. Tyco Electronics CORCOM Products PE Filter with "A" Shield 122 Catalog 1654001 Revised 03-04 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series P Series Part Number Schematic Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. Mounting Extender Style Options* Switch Options Voltage Select Fuse Options Filter Type Filter Current Shield Options* P S J 0 X S S 6 0 The part number PSJ0XSS60 would represent the equivalent of CORCOM J Series 6J4. The part would feature the J extender to fit the current 6J4 panel cutout, and includes no switch, dual voltage select, single fusing, and a 6-amp general purpose filter. Switch Option 0 = Blank S = Double pole single throw (DPST) Extender Option 0 = None C = FN260 J = J Series L = L Series Filter Current 0 = No filter 3 = 3 amps 6 = 6 amps X = 10 amps Fuse Options D = Dual fuse S = Single fuse Input Voltage Select 0 = Single voltage S = Dual voltage select (SMPS) X = Dual voltage select (series/parallel) Filter Type 0 = No filter B = Interconnection block✝ H = Medical Filter L = High Performance Medical S = General purpose Z = High Performance Power Entry Modules Mounting Style E = Mounting ears (Horizontal) S = Snap-in M = Mounting ears (Vertical) Shield Options 0 = No shield A = Filter shield B = Complete Shield C = Complete can (for L & Z models) Part Numbers (partial list) PS000S000 PS0XSS000 PS0S0SBX0 PS000SH30 PS00SDH3A PS0S0SH60 PS0SSDH6A PS00SSHXA PS0SSSHX0 PS000SS30 PS0S0SS30 PS0SSSS6B PS0SXDS60 PSJ0XSS60 PSLS0SS60 PS0SXSS60 PS00SSSXA PS0SSSSX0 PE000DL6C PE000DLXC PE000DZ6C PE000DZXC PE000SL6C PE000SLXC PE000SZ6C PE000SZXC PE000SS30 PE0S0SS30 PE000SS60 PE0SSSSX0 PE000SZXC PE0SSS000 PE0SSSH60 PE0S0DL6C PE0S0DLXC PE0S0DZ6C PE0S0DZXC PE0S0SL6C PE0S0SLXC PE0S0SZ6C PE0S0SZXC Extender for J-Series or others Fuse holder Optional switch Optional filter Additional extender which allows the P series to adapt to CORCOM's L series product cutout, as well as the panel cutout of Schaffner and Delta parts is available. * Extenders cannot be added to units with B shields. ✝ When using the interconnection block, the last 3 digits of the part number are BX(0, A, or B). 123 Catalog 1654001 Revised 03-04 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Filter Options Voltage Selection The P series of power entry modules provides a dual voltage selector which is integrated with the fuseholder. To simplify the wiring in each individual application, Tyco Electronics provides dedicated voltage selectors for different voltage selection schemes. The two most popular schemes are the parallel and serial for dual primary transformers and the “DPST switch” for switching mode power supplies (jumper types.) P series products with an “S” as the fifth digit are specifically designed for “jumper” type applications associated with switching mode power supplies. P series products with an “X” as the fifth digit are specifically designed for dual primary transformer applications. The voltage selector installed will allow proper wiring from these applications. No matter what voltage selection scheme is used, wiring is always made to the same four terminals. Fuseholder Another feature of the P series power entry module is a versatile fusing arrangement. Its fuseholder can hold two 1/4” x 1-1/4” or 5 x 20mm fuses. It can also be converted to accept one fuse with a conversion clip that bridges one of the two fuse chambers. The conversion clip is installed on the P Series power entry modules set for single fusing (those with part numbers with an “S” as the sixth digit). Units with a “D” as the sixth digit do not include a conversion clip. Four filtering options are available in three current ratings. S models (those with an S as the seventh digit) provide general purpose filtering for both line-to-ground and lineto-line noise. The increased inductance of the P series allows better performance than most power entry modules on the market. The S models will generally allow compliance with FCC limits for linear power supplies. The high-performance Z models are available for general applications requiring higher attenuation. The H models greatly reduce line-to-ground capacitance in compliance with UL 544 low leakage current specification. The high-performance L models are available for medical applications requiring higher attenuation. Electrical Schematics H Model S Model L Model LINE LOAD Interconnection Block Installation of the unfiltered versions of the P series involves wiring of the IEC socket to the switch and the switch to the fuseholder. Labor can be eliminated by ordering the product with an interconnection block. This feature, designated by a BX in the seventh and eighth digits, prewires the module for easier installation. The wiring is protected with the plastic case to better prevent access to the terminals and connections. Wiring can be further simplified by ordering a PA100 connector assembly. See page 131 for accessories. The dimensions of this alternative are the same as the filtered versions. Z Model LINE LOAD Shield A new feature available on the P series is an RF shield. The metal shield, available on filtered models, provides shielding from radiated emissions and provides an additional RF ground for the filter to the case. The shield is available in two versions, a shield of the filter components (designated by A as the ninth digit) and a complete shield (designated by B as the ninth digit). The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from magnetic coupling. This shield improves RF ground connection to the case while still allowing the use of the P Series extender. A Shield B Shield The B shield covers the entire power entry module with metal, protecting the equipment from all radiated noise. Used with the filter, the shield provides the most secure protection from RFI noise problems. The B shield cannot be used with any extender. 124 Catalog 1654001 Revised 03-04 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Specifications – Unfiltered Models Hipot rating (one minute): line-to-ground line-to-line Operating frequency: Specifications – Filtered Models 1500 VAC 1450 VDC 50/60 Hz Rated voltage (max.): 250 VAC Rated current, all unfiltered models: 10A @ 120 VAC 10A @ 250 VAC Recommended use connector - no solder Voltage Selection Schemes 1) Dual Primary Transformer Type: 115V 230V Power on/off Hot G Note 1 Note 2 Note 1 Note 2 A B Ground Neutral C 115V 115V Transformer primary Provision for single fusing 2) Jumper Type: 115V 230V Power on/off G Note 1 Note 1 Neutral A B Ground Note 1 .187 x .032 [4.8 x .81] terminal tabs Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Frequency-MHz Rating .03 .1 .15 .5 1 3 5 H Models 03A 7 17 21 27 30 29 26 06A 8 11 15 17 19 18 10A 3 5 8 10 12 11 11 S Models 03A 7 17 21 27 33 40 44 06A 8 12 17 23 32 36 10A 3 5 10 13 23 27 C Note 1 H Power input Sel. Jumpers D SMPS Provision for single fusing Note 1: Jumpers are required if a filter or interconnection module is not used. Note 2: Location of optional filter. Jumpers are required if a filter or interconnection module is not used. Current Rating .01 .05 Z Models 06A 8 21 10A 5 17 L Models 06A 8 21 10A 5 17 30 23 16 10 15 13 10 50 44 35 32 30 27 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. .1 Frequency-MHz .15 .5 1 5 10 30 27 22 30 37 24 27 43 32 49 52 52 47 42 40 27 22 29 34 23 24 35 25 25 21 21 18 16 14 10 30 48 40 40 41 35 32 50 55 55 45 45 45 Line-to-line in 50 ohm circuit Current Frequency-MHz Rating .10 .15 .5 1 3 5 H Models 03A 2 4 12 18 31 40 06A 2 4 12 16 26 35 10A 2 4 12 16 26 33 S Models 03A 2 4 12 15 30 48 06A 2 4 12 15 22 42 10A 2 4 12 15 22 42 Current Rating .01 .05 Z Models 06A 10 15 10A 10 20 L Models 06A 10 15 10A 10 20 Catalog 1654001 Revised 03-04 10 D H Hot Terminals: Power Entry Modules Operating voltages: Selectable or fixed 115/230 VAC Fuseholder: Accepts one or two fuses 1/4 x 1-1/4 or 5 x 20 mm Conversion clip provided on fuseholder for single fuse models. Switch: Double-insulated rated for 10,000 operations at full load. 51 Amp inrush capability Terminals: .187 x .032 [4.8 x .81] terminal tabs Maximum leakage current, each line-to-ground: @ 120 VAC 60 Hz: H Models 2 µA S Models 0.25 mA @ 250 VAC 50 Hz: H Models 5 µA S Models .50 mA Hipot rating (one minute): line-to-ground 1500 VAC line-to-line 1450 VAC Operating voltages: Selectable or fixed 115/230 VAC Operating frequency: 50/60 Hz Rated voltage: 120/250 VAC Conversion clip provided on fuseholder for single fuse models Switch: Double-insulated, rated for 10,000 operations at full load. 51 Amp inrush capability. Dimensions are shown for reference purposes only. Specifications subject to change. .1 Frequency-MHz .15 .5 1 5 10 30 34 20 44 75 35 67 75 75 75 75 70 70 60 60 34 20 44 75 35 67 75 75 75 75 70 70 60 60 USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com 125 CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Case Styles PS/PSL Filtered Unfiltered Panel Cutout 0.06 R Max. 1.52 C C E (1) 0.02 R Min. .508 .225 Max. 5.72 B1 .225 5.72 D (1) For snap-in applications, the D sides of the cutout must have a .02 [.508] radius on the installation side. Note: Snap-in models allow front mounting only. PS not recommended for plastic panels. B2 A PE Filtered Unfiltered Panel Cutout .06 R Max 1.52 E C C .020 R Min .508 .225 Max. 5.72 D B1 .225 Max. 5.72 D B2 F F A PM Filtered Unfiltered Panel Cutout A D D F E C .225 Max. 5.72 B1 .225 Max. 5.72 B2 F .06 1.52 R Max 126 Catalog 1654001 Revised 03-04 ACTUAL MEASUREMENTS A = 1.2" B = 2.13" Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com CORCOM Product Guide The CHAMELEON Adaptable Module for General, High Performance or Medical Applications (Continued) P Series Case Styles PSC/PSJ Unfiltered Filtered Panel Cutout 0.06 R Max. 1.52 C C E Power Entry Modules (1) 0.02 R Min. .508 D .225 Max. 5.72 A B1 Filtered Versions .225 5.72 (1) For snap-in applications, the D sides of the cutout must have a .02 [.508] radius on the installation side. Note: Snap-in models allow front mounting only. PS not recommended for plastic panels. B2 Case Dimensions Part No. "A" Shield A B1 B2 C D (max) (max) (max) (max) PS PSL C PE PM 0.225 Max. .508 B PSC PSJ "B" Shield 1.24 31.49 1.24 31.49 1.98 50.29 1.24 31.49 1.24 31.49 1.24 31.49 1.93 49.02 1.93 49.02 1.93 49.02 1.93 49.02 1.93 49.02 1.93 49.02 2.13 54.1 2.13 54.1 2.13 54.1 2.13 54.1 2.13 54.1 2.13 54.1 2.31 58.67 2.31 58.67 2.31 58.67 2.9 73.66 2.51 63.75 2.72 69.09 E F +.008/-.000 +.008/-.000 +.20/-.00 +.20/-.00 1.06∆ 26.93 1.12 28.45 1.122 28.5 1.06 26.93 1.06 26.93 1.06 26.93 2.201* — 55.91 2.201* — 55.91 2.201* 1.575 55.91 40.0 2.13 2.496 54.1 63.4 2.52 — 64.01 2.6+ — 66.0 * Panel cutout for thickness of .031 - .079 [0.8 - 2.0]. For panel thickness at .083 - .114 [2.1 - 2.9] use 2.213 [56.21]. + Panel cutout for thickness of 0.06 - 0.09 [0.76 - 2.29]. ∆ For shielded models use D=1.12 +.008/-.000. Shields can be used only with filtered models. Shields add approximately 0.06" to depth. B shield may not be used with J or C extender. C Rear View Filtered 0.225 Max. .508 B Unfiltered A B C D A B C D L N 127 Catalog 1654001 Revised 03-04 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 1-508-992-4495 Germany: 49-89-6089-0 www.cor.com www.tycoelectronics.com
PE0SXDS3A 价格&库存

很抱歉,暂时无法提供与“PE0SXDS3A”相匹配的价格&库存,您可以联系我们找货

免费人工找货