General Purpose
RT-iPower
SCHRACK
Power PCB Relay RT Inrush Power
n 1
pole 16A, 1 form A (NO) contact (AgSnO2 or W pre-make contact +
AgSnO2)
n Mono- or bistable coil
n 5kV/10mm coil-contact
n Reinforced insulation
n Test tab (manual operator) optional for RTT3T bistable versions
n WG version: product in accordance to IEC60335-1
n RTS3T: Electronic ballast UL508/NEMA 410 rated
n RTSET: 8A Electronic ballast rated
Typical applications
LED lighting systems, filament and incandescent lamp loads, movement
detectors, light sensors, intelligent wall sockets, motors (RTS3L), bus
system actuators.
Zb
Approvals
VDE Cert. No. 40007571,UL E214025, cCSAus 1142018
Technical data of approved types on request.
Contact Data
RT.3T / RTSET
RTS3L
Contact arrangement
1 form A (NO) contact
Rated voltage
250VAC
Max. switching voltage
480VAC
Rated current
16A
Limiting continuous current
16A
20A
Limiting making current,
max. 20ms (incand. lamps) 165A peak
120A peak
max. 200µs
800A peak
Breaking capacity max.
4000VA
Contact material
W (pre-make cont.)
AgSnO2
+AgSnO2
Contact style
pre-make contact
single contact
Frequency of operation, with/without load
360/3600h-1
Operate/release time max., DC coil
10/5ms
Operate/Reset time max., bistable version
10/10ms
Bounce time max.
4ms
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
RTS3L
A (NO)
20A, 250VAC resistive, 70°C
20x103
RTS3L monostable A (NO) 16A, 250VAC resistive, 85°C
100x103
RTS3T
A (NO)
16A, 250VAC resistive, 85°C
5x103
In process:
Type
Contact
Load
Cycles
RTSET
A (NO)
16A, 250VAC resistive, 85°C
5x103
UL 508
RTS3L
A (NO)
20A, 250VAC, general purpose, 70°C 20x103
RTS3L
A (NO)
16A, 250VAC, resistive, 85°C
50x103
RTS3L
A (NO)
TV8, 240VAC, 40°C
25x103
RTS3L
A (NO)
1.5hp, 240VAC, 70°C
30x103
RTS3T
A (NO)
1200W Tungsten, 120VAC/277VAC,
60Hz, 50°C
6x103
RTS3T
A (NO)
2A, 480VAC, magnetic ballast, 80°C 10x103 *
RTS3T
A (NO)
2A, 480VAC, electronic ballast, 80°C 10x103*
RTS3T
A (NO)
3A, 277VAC, electronic ballast, 80°C 15x103
RTS3T
A (NO)
5A, 120VAC, electronic ballast, 80°C 15x103
RTS3T
A (NO)
5A, 277VAC, electronic ballast, 85°C 10x103
RTS3T
A (NO)
5A, 347VAC, electronic ballast, 105°C
with z.c
10x103*
RTS3T
A (NO)
5A, 347VAC, magnetic ballast, 105°C 10x103
RTS3T
A (NO)
3A, 480VAC, magnetic ballast, 105°C 10x103*
RTSET
A (NO)
16A, 250VAC, general purpose, 85°C
5x103
RTSET
A (NO)
8A, 277VAC, electronic ballast, 85°C
6x10³
RTSET
A (NO)
5A, 277VAC, electronic ballast, 85°C
10x103
RTSET
A (NO)
3A, 277VAC, electronic ballast, 85°C
20x103
RTSET
A (NO)
5A, 120VAC, electronic ballast, 85°C
20x103
Contact Data (continued),
Mechanical endurance
DC coil
bistable version
tab manually operated
RT.3T / RTSET
>5x106 ops.
>3x106 / >1x106 ops.
>1x103 ops.
Coil Data, monostable DC coil
Coil voltage range
Operative range, IEC 61810
Coil insulation system according UL1446
RT.3T
RTS3L
>10x106 ops.
>5x106 ops.
-
RTSET
5 to 110VDC
2
class F
RTS3L
Coil versions, monostable DC coil
Coil
Rated
Operate
Release
Coil
Rated coil
code voltage voltage voltage
resistance power
1)
VDC VDC VDC
Ω±10% mW
005 5 3.5 0.5 62 403
006 6 4.2 0.6 90 400
009 9 6.3 0.9 203 400
012 12 8.4 1.2 360 400
024 24 16.8 2.4 1440 400
048 48 33.6 4.8 5520 417
060
60
42.0
6.0
85701) 420
110 110 77.0 11.0
288001) 420
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
* Special test conditions available on request
01-2019, Rev. 0119
www.te.com
© 2014 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
1
General Purpose
RT-iPower
SCHRACK
Power PCB Relay RT Inrush Power (Continued)
Coil Data (continued),
bistable coils
1 coil
2 coils
Coil Data
RT.3T
RTS3L
Magnetic system
polarized, bistable
Coil voltage range
3 to 24VDC
Operative range, IEC 61810
2
Limiting voltage, % of rated coil voltage 120%
150%
Min./Max. energization duration 30ms/1min at