Glass Wire Wound sensor Type GX
Temperature sensor
Large temperature range
From -200°C to +400°C
No hysteresis
High vibrations resistant
Resistant to external forces and
pressures
Small dimensions
High temperature stability
Short response time
DESCRIPTION
One or two platinum bands layout are wounded on a glass tube and are protected from environment by a glass
layer.
FEATURES
APPLICATIONS
Nominal value: 100 at 0°C
Tolerance according to IEC 60751: class W 0.3,
W 0.15 and W 0.1
Temperature coefficient = 3850 ppm/K
Closer tolerances in restricted temperature range
Environments subject to high vibrations
Cryogenics
Accurate temperature measurement with high
temperature gradient
Connection wires: Platinum coated nickel
The lead wires connection is pull up force
resistant
Housing advise: To be used preferably in dry
environment
Limited mounting space required
Options: - Lead wires length
- Extension cable
Food industry
H.V.A.C.
GWW type GX
www.meas-spec.com
1/3
Rev1 February 2012
Glass Wire Wound sensor Type GX
PERFORMANCE SPECIFICATIONS
Type
DesiReference
gnation
Nominal
reference
(Ohm at 0°C)
1Pt100
1Pt100
1Pt100
1Pt100
1Pt100
2Pt100
GX 518
GX 1013
GX 1018
GX 1218
GX 1513
GX 1528
1Pt100
1Pt100
1Pt100
1Pt100
2Pt100
GX 518
GX 1013
GX 1218
GX 1513
GX 1528
1Pt100
1Pt100
1Pt100
1Pt100
GX 518
GX 1013
GX 1218
GX 1513
L WL D AL1 AL2
(Dimensions in mm)
A
Selfheating
in air
(K/mW)
Response time (s)
Water
v = 0,4 m/s
t0,5
t0,9
Tolerance Class W 0.3 = ± (0.3+0.005 ItI) From -196°C to + 400°C
32 205 108
100
5 3 1,8 10
- 0,20
0,36
0,14
0,35
32 205 113
100
10 6 1,3 10
- 0,20
0,39
0,4
1,30
32 205 118
100
10 6 1.8 10 - 0,20
0.36
0.14
0.35
34 015 120
100
12 3 1.8 6
- 0,20
0.36
0.14
0.35
SB0921
100
15 6 1.3 10 - 0,20
0.39
0.4
1.3
32 205 228
100
15 7 2,8 10 12 0,25
0,20
0,3
1,0
Tolerance Class W 0.15 = ± (0.15+0.002 ItI) From -100°C to + 250°C
32 205 074
100
5 3 1,8 10
- 0,20
0,36
0,14
0,35
32 205 458
100
10 6 1,3 10
- 0,20
0,39
0,4
1,30
34 015 121
100
12 3 1.8 6
- 0,20
0.36
0.14
0.35
SB0920
100
15 6 1.3 10 - 0,20
0.39
0.4
1.3
32 205 241
100
15 7 2,8 10 12 0,25
0,20
0,3
1,0
Tolerance Class W 0.1 = ± (0.1+0.0017 ItI) From 0°C to + 150°C
32 205 101
100
5 3 1,8 10
- 0,20
0,36
0,14
0,35
32 205 463
100
10 6 1.3 10
- 0.20
0.39
0.4
1.3
34 015 123
100
12 3 1.8 6
- 0,20
0.36
0.14
0.35
SB0919
100
15 6 1.3 10 - 0,20
0.39
0.4
1.3
Air
v = 1 m/s
t0,5 t0,9
8
4
8
8
4
12
30
12
30
30
12
45
8
4
8
4
12
30
12
30
12
45
8
4
8
4
30
12
30
12
VALUES FOR PT100
°C
-200
-150
-100
-50
0
50
100
GWW type GX
Ohms
18.52
39.72
60.26
80.31
100
119.40
138.51
Ohms/°C
0.432
0.417
0.405
0.397
0.391
0.385
0.379
°C
150
200
250
300
350
400
www.meas-spec.com
2/3
Ohms
157.33
175.86
194.10
212.05
229.72
247.09
Ohms/°C
0.374
0.368
0.362
0.356
0.350
0.345
Rev1 February 2012
Glass Wire Wound sensor Type GX
BLOCK DIAGRAM
DIMENSIONAL TOLERANCES:
L
D
AL
A
(length of body)
(diameter of body)
(connection wire length)
(connection wire diameter)
= 1mm
= +0,1;-0,3mm
= 2mm
= 0,02 mm
ORDERING INFORMATION
NORTH AMERICA
EUROPE
ASIA
MEAS - Shrewsbury
910 Turnpike Road
Shrewsbury, MA 01545
United States
+1 508-842-0516
+1 508-842-0342
MEAS - France
48, rue de Frégy
77610 Fontenay Trésigny
France
Tel: +33(0) 1 64 42 52 52
Fax: +33(0) 1 64 42 63 17
temperature.cs.amer@meas-spec.com
sales.ftny.fr@meas-spec.com
MEAS - China
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District, Shenzhen 518057
China
Tel: +86 (0) 755 33305088
Fax: +86 (0) 755 33305099
temperature.sales.asia@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the
manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement
Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different
applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement
Specialties, Inc. does not convey any license under its patent rights nor the rights of others.
GWW type GX
www.meas-spec.com
3/3
Rev1 February 2012
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TE Connectivity:
SB0920