General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M
n 4
pole relay with force guided contacts according to EN EN61810-3
(formerly EN50205)
n Compact design and space efficient
Typical applications
Emergency shut-off, press control, machine control, elevator and escalator
control, safety relays
F0244-C
Z
Approvals
VDE Cert. No. 40005334, UL E214025, TUV 968/EL 230,
CCC 2020970303000303
Technical data of approved types on request
Contact Data
Contact arrangement 3 form A + 1 form B contacts
3 NO + 1 NC
2 form A + 2 form B contacts
2 NO + 2 NC
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A
Contact material
AgSnO2
Contact style single contact, force guided
type A according to EN61810-3
(formerly EN50205)
Min. recommended contact load
5V/10mA
Initial contact resistance
≤100mΩ at 1A, 24VDC
≤20Ω at 10mA, 5VDC
Frequency of operation, with/without load
6/150min-1
Contact ratings
Type
Contact
Load
Cycles
IEC 61810
SR4
1xA (NO)
8A, 250VAC, cosφ=1, 70°C
20x103
SR4
1xB (NC)
5A, 250VAC, cosφ=1, 70°C
20x103
UL 508
SR4
A/B (NO/NC) 8A, 250VAC, general purpose, 70°C 6.000
SR4
1xA (1xNO) R300, B300
6.000
SR4
1xB (1xNC) R300
6.000
EN60947-5-1
SR4
1xA/1xB (1xNO/1xNC) 3A, 24VDC, DC13
6.050
SR4
1xA (1xNO)
3A, 250VAC AC-15
6.050
More ratings and information see product specification 2158002
Mechanical endurance
10x106 operations
10-2020, Rev. 1020
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Coil data
Coil voltage range
5 to 110VDC
Coil versions, DC-coil
Coil
Rated
Operate
Release
Coil
Rated coil
code voltage voltage voltage
resistance power
VDC VDC VDC
Ω±10%
mW
005 5 3.8 0.5 31 806
006 6 4.5 0.6 45 800
009 9 6.8 0.9 101 802
012 12 9.0 1.2 180 800
015 15 11.3 1.5 281 801
018 18 13.5 1.8 405 800
021 21 16.0 2.1 551 800
024 24 18.0 2.4 720 800
036 36 27.0 3.6 1620 800
040 40 30.0 4.0 2000 800
048 48 36.0 4.8 2880 800
060 60 45.0 6.0 4500 800
085 85 63.8 8.5 9031 800
110 110 83.0 11.0 15125 800
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M (Continued)
Insulation Data
PCB layout / terminal assignment
Initial dielectric strength
between open contacts
1500Vrms
between contact and coil
4000Vrms
between adjacent contacts
2500Vrms
Clearance/creepage
between open contacts
microdisconnection
between contact and coil
≥10/10mm
between adjacent contacts
≥3/3.5mm
Insulation to EN 50178, type of insulation
between contact and coil
reinforced
between adjacent contacts
basic
Bottom view on solder pins
S0413-BC
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
-25 to 70°C
Category of environmental Protection
IEC 61 810
RTIII
Weight 30g
Resistance to soldering heat THT
IEC 60068-2-20
260°C/5s
Packaging/unit
tube/10 pcs.
2 form A + 2 form B, 2 NO + 2 NC contacts
S0413-BB
3 form A + 1 form B, 3 NO + 1 NC contacts
For more detailed information see product specification 2158002
Dimensions
S0413-BA
S0412-BH
Product code structure
Typical product code SR4 D 4 012
Type
SR4 Relay with force guided contacts SR4
Contact arrangement
D 2 form A + 2 form B contacts (2 NO + 2 NC)
M 3 form A + 1 form B contacts (3 NO + 1 NC)
Contact material
4 AgSnO2
Coil
Coil code: please refer to coil versions table (e.g. 012=12VDC)
Other types on request
2
10-2020, Rev. 1020
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
General Purpose Relays
Force Guided Relays
SCHRACK
Force Guided Relay SR4 D/M (Continued)
Product code
Type
Contact arrangement Contact material
Coil
Part number
SR4D4005
4 pole
2 form A + 2 form B,
AgSnO2 5VDC 7-1415054-1
SR4D4006
relay with
2 NO + 2 NC
6VDC
8-1415054-1
SR4D4009
force guided contacts
contacts
9VDC
9-1415054-1
SR4D4012
12VDC
1415055-1
SR4D4018
18VDC
1-1415055-1
SR4D4021
21VDC
2-1415055-1
SR4D4024
24VDC
3-1415055-1
SR4D4036
36VDC
4-1415055-1
SR4D4040
40VDC
5-1415055-1
SR4D4048
48VDC
6-1415055-1
SR4D4060
60VDC
7-1415055-1
SR4D4085
85VDC
8-1415055-1
SR4D4110
110VDC
9-1415055-1
SR4M4005
3 form A + 1 form B,
5VDC
5-1415053-1
SR4M4006
3 NO + 1 NC
6VDC
6-1415053-1
SR4M4009 contacts 9VDC
7-1415053-1
SR4M4012
12VDC
8-1415053-1
SR4M4018
18VDC
9-1415053-1
SR4M4021
21VDC
1415054-1
SR4M4024
24VDC
4-1415053-1
SR4M4036
36VDC
1-1415054-1
SR4M4040
40VDC
2-1415054-1
SR4M4048
48VDC
3-1415054-1
SR4M4060
60VDC
4-1415054-1
SR4M4085
85VDC
5-1415054-1
SR4M4110
110VDC
6-1415054-1
10-2020, Rev. 1020
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
3