Specialty Relays
SST Series, Industrial Grade Discrete Plug-in, Time Delay Relay
Timing Specifications
Product Facts
n
On-Delay, Off-Delay,
Interval, One Shot & Repeat
modes
n
Time delays to 120 min.
n
Fast setting with time
calibrated knobs
n
Superior transient
protection
n
Rugged construction with
8- or 11-pin plug
n
Flame retardant housing
n
File E15631, File LR33434
Timing Modes —
On-Delay, Off-Delay, Interval, One Shot
(Latching Interval) or Repeat Cycle.
Timing Ranges — Nine ranges spanning 0.1 sec. to 120 min.
Timing Adjustment — Knob adjust.
Accuracy —
Repeat Accuracy — ±1%
Overall Accuracy — ±5%
Reset Time — 50 ms., max., (25 ms
typ.) for on-delay and interval; 300 ms,
max., for off-delay and one shot; 500
ms, max., for repeat type.
Relay Operate Time — 50 ms.
Relay Release Time — 30 ms.
Expected Mechanical Life —
10 million operations
Expected Electrical Life — 500,000
operations, min., at rated resistive load.
Initial Dielectric Strength —
Between Contacts, Line Inputs and
Control Circuits — 1,500V RMS,
minimum, at 60 Hz.
Input Data @ 25°C
Voltage — See Ordering Information
section for details.
Power Requirement — 3W max.
Transient Protection —
Non-repetitive transients of the following
magnitudes will not cause spurious
operation of affect function and accuracy.
Contact Data @ 25°C
Arrangements — 2 Form C (DPDT)
Rating — 10A @ 120/240VAC, resistive; 1/3 HP @ 120/240VAC, 50/60 Hz.
Operating
Voltage
12VDC
12 &
24 VAC/VDC
120 VAC