U86B
Urea Dosing
SPECIFICATIONS
FEATURES
•
•
•
•
•
Mountable O-ring with seal
±0.5% Accuracy
±2.0 Total Error Band
Cable option
Freeze Protection Available
APPLICATIONS
•
•
•
•
•
Urea level
Urea pressure
Air brakes
Corrosive fluid measurement for E&V
applications
Automotive
SENSOR SOLUTIONS ///U86B
•
Mountable with O-ring seal
•
Stainless Steel wetted surfaces
•
Amplified
•
ASIC calibrated
•
Absolute, sealed gage
•
Cable option
•
Analog output
•
SENT Output Optional (contact factory for details)
The U86B is an automotive designed 16mm media isolated,
piezoresistive silicon pressure sensor packaged in a 316L
stainless steel housing and is designed for O-ring mounting.
The sensing package utilizes silicone oil to transfer pressure
from the 316L stainless steel diaphragm to the sensing element.
The U86B is designed for high performance, low pressure
applications. A custom ASIC is used for temperature
compensation, offset correction, and provides an amplified
output of 0.5 to 4.5V. CE approved and manufactured to
TS16949 standard, this model may also come with a cable if
desired. For a similar sensor without plastic housing, refer to the
86A or for a plastic threaded fitting, refer to the LM pressure
transducer.
07/2018
Page 1
U86B
Urea Dosing
STANDARD RANGES
Range
psiA, psiG, psiS
Range
barA, barG, barS
0 to 050
•
0 to 005
•
0 to 100
•
0 to 010
•
0 to 150
•
0 to 012
•
0 to 200
•
0 to 013
•
Other pressure ranges available, please contact factory
PERFORMANCE SPECIFICATIONS
Unless otherwise specified: Supply Voltage: 5V, Ambient Temperature: 25°C after 10 sec warm-up
PARAMETERS
MIN
TYP
MAX
Supply Voltage
4.75
5.00
5.25
V
12.5
mA DC
Supply Current
UNITS
NOTES
Ratiometric Output
0.5
4.5
V
1, 5
Accuracy (combined linearity, hysteresis &
repeatability)
-0.5
0.5
%Span
2
Total Error Band
-2.0
2.0
%Span
3
Compensated Temperature
-7
+105
°C
Operating Temperature
-40
+105
°C
Storage Temperature
-40
+125
Insulation Resistance (500VDC)
10
°C
MΩ
Reverse Voltage
Overvoltage Protection
18
V
18
V
Continuous
Short Circuit Protection
Output Noise @ 1kHZ
13
mV
Response Time (10% to 90%)
1.0
ms
Long Term Stability
Output Load
4
-0.15
0.15
47
Diagnostics Ability
%Span/Year
kΩ
Included
Notes
1.
2.
3.
4.
5.
Ratiometric to supply voltage, pressure transfer function at 5V Voltage Supply, see Chart A
Best Fit Straight Line
TEB includes all accuracy errors, thermal errors, span and zero tolerance over the compensated range
Between sensor body to any pins of connector
This product can be configured for custom OEM requirements, contact factory for different transfer functions and output clipping. See Chart B
SENSOR SOLUTIONS ///U86B
07/2018
Page 2
U86B
Urea Dosing
ENVIRONMENTAL SPECIFICATIONS
PARAMETERS
MAX
UNITS
NOTES
Pressure Overload
MIN
2X
Rated
6
Pressure Burst
3X
Rated
7
Pressure Cycle
TYP
1M
Cycles
Port: 316/316L ST STL
Sealing: FKM Fluoroelastomer 70 (O-Ring)
Housing: PA66 + 30%GF
Material
Freezing Protecting
Optional
9
Notes
6.
7.
8.
9.
The maximum pressure that can be applied without changing the transducer’s performance or accuracy.
The maximum pressure that can be applied to a transducer without rupture of either the sensing element or transducer.
Transducers can be installed by M4X0.7 Torx washer head screws (qty 2) with 2.2Nm torque (values provided are for reference). Actual torque depends
upon on mating support material, surface flatness and different screws. Transducer housing may crack if over-torqued when installing
Medium dead volume that exceeds 350mm3 max in manifold (excluding sensor) may damage the sensor during frozen condition
Agency Approvals
EMC Performance Criteria: Output Change < ±1.5% of FS @RT
ESD
8kV Contact / 15kV Air
ISO 10605
Immunity Radiated Field
Level V, 140V/m, 200MHz-3.2GHz
ISO 11452-2
BCI
d = 150mm, d = 450mm, d = 750mm
ISO 11452-4
Frequency Range: 1MHz-400MHz
Modulation CW, AM
Severity Level V (200mA)
SENT Only
Magnetic Field Test
ISO 11452-8
Emission Conducted. Voltage Mode/Current Probe
CISPR 25
Emission Radiated
CISPR 25
Output Interface
SENSOR SOLUTIONS ///U86B
15Hz to 150kHz, Level 4
Frequency Range: 150kHz – 108MHz, Class 5
Frequency Range: 150kHz - 2.5GHz, Class 5
SENT (SAE J2716, 2010)
07/2018
Page 3
U86B
Urea Dosing
CHARTS
Chart A: Pressure Transfer Function, Supply = 5V
𝑂𝑢𝑡𝑝𝑢𝑡 𝑉𝑜𝑙𝑡𝑎𝑔𝑒 =
80% × 𝑆𝑢𝑝𝑝𝑙𝑦 𝑉
× (𝑃𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝐴𝑝𝑝𝑙𝑖𝑒𝑑 − 𝑃𝑚𝑖𝑛) + 10% × 𝑆𝑢𝑝𝑝𝑙𝑦 𝑉
𝑃𝑚𝑎𝑥 − 𝑃𝑚𝑖𝑛
Chart B: OEM Custom Calibration. High/Low Rail values can be adjusted by Circuit
SENT Functional Block Diagram
(Pin 1)
(Pin 3)
(Pin 2)
SENSOR SOLUTIONS ///U86B
07/2018
Page 4
U86B
Urea Dosing
DIMENSIONS
Dimensions are in inches [mm]
Non-Vent Cap/Non-Freeze option shown
See Note 8
See Note 9
SENSOR SOLUTIONS ///U86B
07/2018
Page 5
U86B
Urea Dosing
CABLE DIMENSIONS
See “Cable Ordering Information” matrix for cable length options
MOLEX HOUSING # 50-57-9403
MOLEX TERMINALS # 16-02-0082
(.100 [2.54] PITCH)
HIGH TEMPERATURE CABLE,
3 CONDUCTORS, 24 AWG
MOLEX CONNECTOR # 43645-0300
MOLEX TERMINALS # 43030-0003
CONDUCTOR: 24 AWG
RATED VOLTAGE: 300V
TEMPERATURE RANGE:
-40OC – 200OC
Customer & Sensor Side
Pos No
Color
Function
1
Red
Supply
2
Black
GND
3
Blue
Output
SENSOR SOLUTIONS ///U86B
07/2018
Page 6
U86B
Urea Dosing
ORDERING INFORMATION
U86B – 100P A 2 – F 1 A
Output Type
A
Analog
Pressure Range
050P
005B
100P
010B
150P
012B
200P
013B
Pressure Type
G
Gage
A
Absolute
S
Sealed Gage
1
2
3
1
Connector
Molex
Freeze Protection
N
None
F
Freeze
Output Ratiometric
0.5V @ 0.0barG/A/S
0.5V @-0.5barG/S
0.5V @ -1.0 barG/S
SENT Output available, contact factory for details
CABLE ORDERING INFORMATION
U86B – CBL – 010 – 1
005
010
020
Cable Length
5 [127]
10 [254]
20 [508]
0
1
Connector
No Connector
Molex Connector #50579403
Cable Lengths are in inches[mm]
NORTH AMERICA
EUROPE
ASIA
Measurement Specialties, Inc.,
a TE Connectivity Company
Tel: +1 800-522-6752
Email: customercare.frmt@te.com
Measurement Specialties (Europe), Ltd.,
a TE Connectivity Company
Tel: +31 73 624 6999
Email: customercare.lcsb@te.com
Measurement Specialties (China), Ltd.,
a TE Connectivity Company
Tel: +86 0400-820-6015
Email: customercare.shzn@te.com
TE.com/sensorsolutions
Measurement Specialties, Inc., a TE Connectivity company.
Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein
might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes
no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard
Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse
of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
© 2015
TE Connectivity Ltd. family of companies
SENSOR SOLUTIONS ///U86B
All Rights Reserved.
07/2018
Page 7