L
Table of Dimensions, inch (mm):
Part
Description
URHR-2
URHR-3
URHR-4
Inside Diameter
Min. Exp. (a)
Max. Rec’d (b)
1.23 (31)
1.44 (37)
1.85 (47)
0.10 (2.5)
0.14 (3.5)
0.18 (4.6)
Outside Diameter
Recovered
(c), Ref
0.375 (9.5)
0.500 (12.7)
0.562 (14.2)
Overall Length
Recovered
L, Ref (See Note*)
0.50 (13)
0.50 (13)
0.75 (19)
Note*:
Alternate lengths available upon request.
Material:
heat shrinkable, cross linked polyolefin, meets MIL-I-81765/1 Type II with Shore
Hardness value 35+/- 5.
Color:
Black
Specification Control Drawing
shrinkHOoP is a Trademark of Tyco Electronics
Tyco Electronics Corporation
300 Constitution Drive
Menlo Park, CA 94025 USA
Title:
shrinkHOoP –Cable Clamp Heat
Shrink Grommet Sizes 2, 3 and 4
Tyco Electronics reserves the right to amend this drawing at any time.
Users should evaluate the suitability of the product for their application.
Document No.
URHR-2-thru-4
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES.
METRIC DIMENSIONS ARE SHOWN IN BRACKETS
DRAWN BY:
U.NGUYEN
CAGE CODE:
06090
Org. Date:
File name:
10/03/2001
R040891
Rev.:
Rev. Date:
F
December 9, 2004
SCALE:
©2004 Tyco Electronics Corporation. All rights reserved
If this document is printed it becomes uncontrolled. Check for the latest revision.
None
SIZE:
SHEET:
A
1 of 2
Table 2: Properties
Physical
Property
Tensile strength
Ultimate elongation
Specific gravity
Water absorption
Hardness, Shore D
Flammability
Corrosion resistance
Low temperature flex
4 hours at –67 ± 2°F (-55 ± 1°C)
Heat resistance
168 hours at 347 ± 2°F
(175 ± 1°C)
Heat shock
4 hours at 437 ± 5°F (225 ± 2°C)
Elastic Memory
Electrical
Dielectric strength
Volume resistivity
Chemical
Fluid Resistance
Requirements
1200 psi (8.3 Mpa) minimum
250% minimum
1.4 maximum
0.5% maximum
35 ± 5
Pass
Pass
Pass
Pass
Test method
ASTM D-412
ASTM D-412
ASTM D-792
ASTM D-570
ASTM D-2240
ASTM D-635
FAR-25
MIL-I-81765
MIL-I-81765
200% ultimate elongation,
minimum
1000 psi (6.9 Mpa) tensile
strength, minimum
No cracking, dripping or flowing
MIL-I-81765
MIL-I-81765
275% minimum expansion to 4 inch (10 cm) of a
fully recovered test specimen, and 93% recovery of
expanded specimen after oven condition for 1
minute at 302 ± 4°F (150 ± 2° C)
200 v/mil (7880 v/mm) minimum ASTM D-149
1012 ohm-cm minimum
ASTM D-257
200% ultimate elongation,
MIL-I-81765
minimum
750 psi (5.2 Mpa) tensile
strength, minimum
Specification Control Drawing