H5PS1G83EFR Series
1Gb DDR2 SDRAM
H5PS1G83EFR-xxC H5PS1G83EFR-xxI H5PS1G83EFR-xxL H5PS1G83EFR-xxJ [TBD] H5PS1G83EFR-xxP H5PS1G83EFR-xxQ H5PS1G83EFR-G7x
This document is a general product description and is subject to change without notice. Hynix Semiconductor does not assume any responsibility for use of circuits described. No patent licenses are implied. Rev. 1.0 / Aug 2009 1
Release H5PS1G83EFR Series
Revision Details
Rev. 1.0 Released History Draft Date Aug. 2009
Rev. 1.0 / Aug 2009
2
Release H5PS1G83EFR Series
Contents
1. Description
1.1 Device Features and Ordering Information 1.1.1 Key Features 1.1.2 Ordering Information 1.1.3 Operating Frequency 1.2 Pin configuration 1.3 Pin Description
2. Maximum DC ratings
2.1 Absolute Maximum DC Ratings 2.2 Operating Temperature Condition
3. AC & DC Operating Conditions
3.1 DC Operating Conditions 3.1.1 Recommended DC Operating Conditions(SSTL_1.8) 3.1.2 ODT DC Electrical Characteristics 3.2 DC & AC Logic Input Levels 3.2.1 Input DC Logic Level 3.2.2 Input AC Logic Level 3.2.3 AC Input Test Conditions 3.2.4 Differential Input AC Logic Level 3.2.5 Differential AC Output Parameters 3.3 Output Buffer Levels 3.3.1 Output AC Test Conditions 3.3.2 Output DC Current Drive 3.3.3 OCD default characteristics 3.4 IDD Specifications & Measurement Conditions 3.5 Input/Output Capacitance
4. AC Timing Specifications 5. Package Dimensions
Rev. 1.0 / Aug 2009
3
Release H5PS1G83EFR Series
1. Description
1.1 Device Features & Ordering Information
1.1.1 Key Features
• • • • • • • • • • • • • • • • • • • • • • • • • VDD = 1.8 +/- 0.1V VDDQ = 1.8 +/- 0.1V All inputs and outputs are compatible with SSTL_18 interface 8 banks Fully differential clock inputs (CK, /CK) operation Double data rate interface Source synchronous-data transaction aligned to bidirectional data strobe (DQS, DQS) Differential Data Strobe (DQS, DQS) Data outputs on DQS, DQS edges when read (edged DQ) Data inputs on DQS centers when write (centered DQ) On chip DLL align DQ, DQS and DQS transition with CK transition DM mask write data-in at the both rising and falling edges of the data strobe All addresses and control inputs except data, data strobes and data masks latched on the rising edges of the clock Programmable CAS latency 3, 4, 5 and 6 supported Programmable additive latency 0, 1, 2, 3, 4 and 5 supported Programmable burst length 4/8 with both nibble sequential and interleave mode Internal eight bank operations with single pulsed RAS Auto refresh and self refresh supported tRAS lockout supported 8K refresh cycles /64ms JEDEC standard 60ball FBGA(x8) Full strength driver option controlled by EMR On Die Termination supported Off Chip Driver Impedance Adjustment supported Self-Refresh High Temperature Entry
Rev. 1.0 / Aug 2009
4
Release H5PS1G83EFR Series Ordering Information
Part No. / Status H5PS1G83EFR-xx*C H5PS1G83EFR-xx*I H5PS1G83EFR-xx*L 128Mx8 H5PS1G83EFR-xx*J H5PS1G83EFR-xx*P H5PS1G83EFR-xx*Q Note: -XX* is the speed bin, refer to the Operating Frequency table for complete part number. -xxP and xxQ are the low current bin, refer to the IDD specification table. - Hynix Halogen-free products are compliant to RoHS. Hynix supports Lead & Halogen free parts for each speed grade with same specification, except Lead free materials. We'll add "R" character after "F" for Lead & Halogen free products Low Power Consumption (IDD6 Only) Low Current Consumption Low Current Consumption Industrial Commercial Industrial Configuration Power Consumption Normal Consumption Normal Consumption Low Power Consumption (IDD6 Only) Operation Temp Commercial Industrial Commercial 60 Ball fBGA Package
Operating Frequency
Grade E3 C4 Y5 S6 S5 G7 Note: -G7 is a special speed product used in electronic engineering for high speed storage of the working data of a consumer digital electronic device. tCK(ns) 5 3.75 3 2.5 2.5 1.875 CL 3 4 5 6 5 7 tRCD 3 4 5 6 5 7 tRP 3 4 5 6 5 7 Unit Clk Clk Clk Clk Clk Clk
Rev. 1.0 / Aug 2009
5
Release H5PS1G83EFR Series
1.2 Pin Configuration & Address Table
128Mx8 DDR2 PIN CONFIGURATION(Top view: see balls through package)
1 2 3 7 8 9
VDD DQ6 VDDQ DQ4 VDDL
NU/RDQS VSSQ DQ1 VSSQ VREF CKE
VSS DM/RDQS VDDQ DQ3 VSS WE BA1 A1 A5 A9 NC
A B C D E F G H J K L
VSSQ DQS VDDQ DQ2 VSSDL RAS CAS A2 A6 A11 NC
DQS VSSQ DQ0 VSSQ CK CK CS A0 A4 A8 A13
VDDQ DQ7 VDDQ DQ5 VDD ODT
BA2
BA0 A10
VDD
VSS
A3 A7
VSS
VDD
A12
ROW AND COLUMN ADDRESS TABLE
ITEMS # of Bank Bank Address Auto Precharge Flag Row Address Column Address Page size 128Mx8 8 BA0, BA1, BA2 A10/AP A0 - A13 A0-A9 1 KB
Rev. 1.0 / Aug 2009
6
Release H5PS1G83EFR Series
1.3 PIN DESCRIPTION
PIN CK, CK TYPE Input DESCRIPTION Clock: CK and CK are differential clock inputs. All address and control input signals are sampled on the crossing of the positive edge of CK and negative edge of CK. Output (read) data is referenced to the crossings of CK and CK (both directions of crossing). Clock Enable: CKE HIGH activates, and CKE LOW deactivates internal clock signals, and device input buffers and output drivers. Taking CKE LOW provides PRECHARGE POWER DOWN and SELF REFRESH operation (all banks idle), or ACTIVE POWER DOWN (row ACTIVE in any bank). CKE is synchronous for POWER DOWN entry and exit, and for SELF REFRESH entry. CKE is asynchronous for SELF REFRESH exit. After VREF has become stable during the power on and initialization sequence, it must be maintained for proper operation of the CKE receiver. For proper self-refresh entry and exit, VREF must be maintained to this input. CKE must be maintained HIGH throughout READ and WRITE accesses. Input buffers, excluding CK, CK and CKE are disabled during POWER DOWN. Input buffers, excluding CKE are disabled during SELF REFRESH. Chip Select: All commands are masked when CS is registered HIGH. CS provides for external bank selection on systems with multiple banks. CS is considered part of the command code. On Die Termination Control: ODT (registered HIGH) enables on die termination resistance internal to the DDR2 SDRAM. When enabled, ODT is only applied to DQ, DQS, DQS, RDQS, RDQS, and DM signal for x4,x8 configurations. For x16 configuration ODT is applied to each DQ, UDQS/UDQS.LDQS/LDQS, UDM and LDM signal. The ODT pin will be ignored if the Extended Mode Register(EMR(1)) is programmed to disable ODT. Command Inputs: RAS, CAS and WE (along with CS) define the command being entered. Input Data Mask: DM is an input mask signal for write data. Input Data is masked when DM is sampled High coincident with that input data during a WRITE access. DM is sampled on both edges of DQS, Although DM pins are input only, the DM loading matches the DQ and DQS loading. For x8 device, the function of DM or RDQS/ RDQS is enabled by EMR command to EMR(1). Bank Address Inputs: BA0 - BA2 define to which bank an ACTIVE, Read, Write or PRECHARGE command is being applied (For 256Mb and 512Mb, BA2 is not applied). Bank address also determines if one of the mode register or extended mode register is to be accessed during a MR or EMR command cycle. Address Inputs: Provide the row address for ACTIVE commands, and the column address and AUTO PRECHARGE bit for READ/WRITE commands to select one location out of the memory array in the respective bank. A10 is sampled during a precharge command to determine whether the PRECHARGE applies to one bank (A10 LOW) or all banks (A10 HIGH). If only one bank is to be precharged, the bank is selected by BA0-BA2. The address inputs also provide the op code during MRS or EMRS commands. Data input / output: Bi-directional data bus Data Strobe: Output with read data, input with write data. Edge aligned with read data, centered in write data. For the x16, LDQS correspond to the data on DQ0~DQ7; UDQS corresponds to the data on DQ8~DQ15. For the x8, an RDQS option using DM pin can be enabled via the EMR(1) to simplify read timing. The data strobes DQS, LDQS, UDQS, and RDQS may be used in single ended mode or paired with optional complementary signals DQS, LDQS,UDQS and RDQS to provide differential pair signaling to the system during both reads and writes. An EMR(1) control bit enables or disables all complementary data strobe signals. DQS, (DQS) (UDQS),(UDQS) (LDQS),(LDQS) (RDQS),(RDQS) Input/Output In this data sheet, "differential DQS signals" refers to any of the following with A10 = 0 of EMR(1) x4 DQS/DQS x8 DQS/DQS if EMR(1)[A11] = 0 x8 DQS/DQS, RDQS/RDQS, if EMR(1)[A11] = 1 x16 LDQS/LDQS and UDQS/UDQS "single-ended DQS signals" refers to any of the following with A10 = 1 of EMR(1) x4 DQS x8 DQS if EMR(1)[A11] = 0 x8 DQS, RDQS, if EMR(1)[A11] = 1 x16 LDQS and UDQS
CKE
Input
CS
Input
ODT
Input
RAS, CAS, WE DM (LDM, UDM)
Input Input
BA0 - BA2
Input
A0 -Amax
Input
DQ
Input/Output
Rev. 1.0 / Aug 2009
7
Release H5PS1G83EFR Series
-ContinuedPIN NC VDDQ VSSQ VDDL VSSDL VDD VSS VREF Supply Supply Supply Supply Supply Supply Supply TYPE DESCRIPTION No Connect: No internal electrical connection is present. DQ Power Supply: 1.8V +/- 0.1V DQ Ground DLL Power Supply: 1.8V +/- 0.1V DLL Ground Power Supply: 1.8V +/- 0.1V Ground Reference voltage.
Rev. 1.0 / Aug 2009
8
Release H5PS1G83EFR Series
2. Maximum DC Ratings
2.1 Absolute Maximum DC Ratings
Symbol VDD VDDQ VDDL VIN, VOUT TSTG II IOZ Parameter Voltage on VDD pin relative to Vss Voltage on VDDQ pin relative to Vss Voltage on VDDL pin relative to Vss Voltage on any pin relative to Vss Storage Temperature Input leakage current; any input 0V VIN VDD; all other balls not under test = 0V) Output leakage current; 0V VOUT VDDQ; DQ and ODT disabled Rating - 1.0 V ~ 2.3 V - 0.5 V ~ 2.3 V - 0.5 V ~ 2.3 V - 0.5 V ~ 2.3 V -55 to +100 -2 uA ~ 2 uA -5 uA ~ 5 uA Units V V V V °C uA uA Notes 1 1 1 1 1, 2
Note: 1. Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. 2. Storage Temperature is the case surface temperature on the center/top side of the DRAM. For the measurement conditions. please refer to JESD51-2 standard.
2.2 Operating Temperature Condition
Symbol TOPER Note: 1. Operating Temperature is the case surface temperature on the center/top side of the DRAM. For the measurement conditions, please refer to JESD51-2 standard. 2. At 85~95° TOPER , Double refresh rate(tREFI: 3.9us) is required, and to enter the self refresh mode at this temperature range it must be required an EMRS command to change itself refresh rate. Parameter Commercial Operating Temperature Industrial Rating 0 to 95 -40 to 95 Units °C Notes 1,2
Rev. 1.0 / Aug 2009
9
Release H5PS1G83EFR Series
3. AC & DC Operating Conditions
3.1 DC Operating Conditions
3.1.1 Recommended DC Operating Conditions (SSTL_1.8)
Symbol VDD VDDL VDDQ VREF VTT Note: 1. Min. Typ. and Max. values increase by 100mV for C3(DDR2-533 3-3-3) speed option. 2. VDDQ tracks with VDD,VDDL tracks with VDD. AC parameters are measured with VDD,VDDQ and VDD. 3. The value of VREF may be selected by the user to provide optimum noise margin in the system. Typically the value of VREF is expected to be about 0.5 x VDDQ of the transmitting device and VREF is expected to track variations in VDDQ 4. Peak to peak ac noise on VREF may not exceed +/-2% VREF (dc). 5. VTT of transmitting device must track VREF of receiving device. Parameter Supply Voltage Supply Voltage for DLL Supply Voltage for Output Input Reference Voltage Termination Voltage Rating Min. 1.7 1.7 1.7 0.49*VDDQ VREF-0.04 Typ. 1.8 1.8 1.8 0.50*VDDQ VREF Max. 1.9 1.9 1.9 0.51*VDDQ VREF+0.04 Units V V V mV V Notes 1 1,2 1,2 3,4 5
3.1.2 ODT DC electrical characteristics
PARAMETER/CONDITION Rtt effective impedance value for EMR(A6,A2)=0,1; 75 ohm Rtt effective impedance value for EMR(A6,A2)=1,0; 150 ohm Rtt effective impedance value for EMR(A6,A2)=1,1; 50 ohm Deviation of VM with respect to VDDQ/2 SYMBOL Rtt1(eff) Rtt2(eff) Rtt3(eff) delta VM MIN 60 120 40 -6 NOM 75 150 50 MAX 90 180 60 +6 UNITS NOTES ohm ohm ohm % 1 1 1 1
Note: 1. Test condition for Rtt measurements Measurement Definition for Rtt(eff): Apply VIH (ac) and VIL (ac) to test pin separately, then measure current I(VIH (ac)) and I(VIL(ac)) respectively. VIH (ac), VIL (ac), and VDDQ values defined in SSTL_18 VIH (ac) - VIL (ac) I(VIH (ac)) - I(VIL (ac)) Measurement Definition for VM: Measurement Voltage at test pin (mid point) with no load.
Rtt(eff) =
2 x Vm delta VM =( VDDQ - 1) x 100%
Rev. 1.0 / Aug 2009
10
Release H5PS1G83EFR Series 3.2 DC & AC Logic Input Levels
3.2.1 Input DC Logic Level
Symbol VIH(dc) VIL(dc) Parameter dc input logic HIGH dc input logic LOW Min. VREF + 0.125 - 0.3 Max. VDDQ + 0.3 VREF - 0.125 Units V V Notes
3.2.2 Input AC Logic Level
Symbol VIH (ac) VIL (ac) Symbol VIH (ac) VIL (ac) Parameter DDR2 400,533 Min. Max. DDR2 667,800 Min. Max. Units V V Units V V Notes Notes
ac input logic HIGH VREF + 0.250 VDDQ+Vpeak VREF + 0.200 VDDQ+Vpeak ac input logic LOW Parameter ac input logic HIGH ac input logic LOW VSSQ-Vpeak VREF - 0.250 VSSQ-Vpeak VREF - 0.200 DDR2 1066 Min. VREF + 0.200 VSSQ-Vpeak Max. VDDQ+Vpeak VREF - 0.200
3.2.3 AC Input Test Conditions
Symbol VREF VSWING(MAX) SLEW Note: 1. Input waveform timing is referenced to the input signal crossing through the VREF level applied to the device under test. Condition Input reference voltage Input signal maximum peak to peak swing Input signal minimum slew rate Value 0.5 * VDDQ 1.0 1.0 Units V V V/ns Notes 1 1 2, 3
VDDQ VIH(ac) min
VSWING(MAX)
VIH(dc) min VREF VIL(dc) max VIL(ac) max VSS
delta TF Falling Slew = VREF - VIL(ac) max delta TF
delta TR
Rising Slew = VIH(ac) min - VREF delta TR
2. The input signal minimum slew rate is to be maintained over the range from VREF to VIH(ac) min for rising edges and the range from VREF to VIL(ac) max for falling edges as shown in the figure below. 3. AC timings are referenced with input waveforms switching from VIL(ac) to VIH(ac) on the positive transitions and VIH(ac) to VIL(ac) on the negative transitions.
Rev. 1.0 / Aug 2009
11
Release H5PS1G83EFR Series
3.2.4 Differential Input AC logic Level
Symbol VID (ac) VIX (ac) Note:
Parameter ac differential input voltage ac differential cross point voltage
Min. 0.5 0.5 * VDDQ - 0.175
Max. VDDQ + 0.6 0.5 * VDDQ + 0.175
Units Notes V V 1 2
1. VIN(DC) specifies the allowable DC execution of each input of differential pair such as CK, CK, DQS, DQS, LDQS, LDQS, UDQS and UDQS. 2. VID(DC) specifies the input differential voltage |VTR -VCP | required for switching, where VTR is the true input (such as CK, DQS, LDQS or UDQS) level and VCP is the complementary input (such as CK, DQS, LDQS or UDQS) level. The minimum value is equal to VIH(DC) - V IL(DC).
VDDQ VTR VID VCP VSSQ
< Differential signal levels >
Note: 1. VID(AC) specifies the input differential voltage |VTR -VCP | required for switching, where VTR is the true input signal (such as CK, DQS, LDQS or UDQS) and VCP is the complementary input signal (such as CK, DQS, LDQS or UDQS). The minimum value is equal to V IH(AC) - V IL(AC). 2. The typical value of VIX(AC) is expected to be about 0.5 * VDDQ of the transmitting device and VIX(AC) is expected to track variations in VDDQ. VIX(AC) indicates the voltage at which differential input signals must cross.
Crossing point
VIX or VOX
3.2.5 Differential AC output parameters
Symbol VOX (ac) Note: 1. The typical value of VOX(AC) is expected to be about 0.5 * V DDQ of the transmitting device and VOX(AC) is expected to track variations in VDDQ. VOX(AC) indicates the voltage at which differential output signals must cross. Parameter ac differential cross point voltage Min. 0.5 * VDDQ - 0.125 Max. 0.5 * VDDQ + 0.125 Units V Notes 1
Rev. 1.0 / Aug 2009
12
Release H5PS1G83EFR Series 3.3 Output Buffer Characteristics
3.3.1 Output AC Test Conditions
Symbol VOTR Note: 1. The VDDQ of the device under test is referenced. Parameter Output Timing Measurement Reference Level SSTL_18 Class II 0.5 * VDDQ Units V Notes 1
3.3.2 Output DC Current Drive
Symbol IOH(dc) IOL(dc) Note: 1. VDDQ = 1.7 V; VOUT = 1420 mV. (VOUT - VDDQ)/IOH must be less than 21 ohm for values of VOUT between VDDQ and VDDQ - 280 mV. 2. VDDQ = 1.7 V; VOUT = 280 mV. VOUT/IOL must be less than 21 ohm for values of VOUT between 0 V and 280 mV. 3. The dc value of VREF applied to the receiving device is set to VTT 4. The values of IOH(dc) and IOL(dc) are based on the conditions given in Notes 1 and 2. They are used to test device drive current capability to ensure VIH min plus a noise margin and VIL max minus a noise margin are delivered to an SSTL_18 receiver. The actual current values are derived by shifting the desired driver operating point (see Section 3.3) along a 21 ohm load line to define a convenient driver current for measurement. Parameter Output Minimum Source DC Current Output Minimum Sink DC Current SSTl_18 - 13.4 13.4 Units mA mA Notes 1, 3, 4 2, 3, 4
Rev. 1.0 / Aug 2009
13
Release H5PS1G83EFR Series
3.3.3 OCD default characteristics
Description Output impedance Output impedance step size for OCD calibration Pull-up and pull-down mismatch Output slew rate Note : 1. Absolute Specifications ( Toper; VDD = +1.8V ±0.1V, VDDQ = +1.8V ±0.1V) 2. Impedance measurement condition for output source dc current: VDDQ=1.7V; VOUT=1420mV; (VOUTVDDQ)/Ioh must be less than 23.4 ohms for values of VOUT between VDDQ and VDDQ-280mV. Impedance measurement condition for output sink dc current: VDDQ = 1.7V; VOUT = 280mV; VOUT/Iol must be less than 23.4 ohms for values of VOUT between 0V and 280mV. 3. Mismatch is absolute value between pull-up and pull-dn, both are measured at same temperature and voltage. 4. Slew rate measured from vil(ac) to vih(ac). 5. The absolute value of the slew rate as measured from DC to DC is equal to or greater than the slew rate as measured from AC to AC. This is guaranteed by design and characterization. 6. This represents the step size when the OCD is near 18 ohms at nominal conditions across all process corners/variations and represents only the DRAM uncertainty. A 0 ohm value(no calibration) can only be achieved if the OCD impedance is 18 ohms +/- 0.75 ohms under nominal conditions. Output Slew rate load:
VTT
Parameter
Min 0 0
Nom -
Max 1.5 4
Unit ohms ohms ohms V/ns
Notes 1 6 1,2,3 1,4,5,6,7,8
Sout
1.5
-
5
25 ohms
Output (Vout)
Reference point
7. DRAM output slew rate specification applies to 400, 533 and 667 MT/s speed bins. 8. Timing skew due to DRAM output slew rate mis-match between DQS / DQS and associated DQs is included in tDQSQ and tQHS specification.
Rev. 1.0 / Aug 2009
14
Release H5PS1G83EFR Series
3.4 IDD Specifications & Test Conditions IDD Specifications(max) - I
DDR2 400 x8 IDD0 IDD1 IDD2P IDD2Q IDD2N IDD3P IDD3N IDD4W IDD4R IDD5 Normal IDD6 Low power F S 60 70 10 22 30 25 12 40 100 100 160 10 5 190 DDR2 533 x8 65 75 10 27 35 25 12 45 120 120 160 10 5 190 DDR2 667 x8 70 80 10 30 40 25 12 50 145 140 165 10 5 195 DDR2 800 x8 75 85 10 32 45 25 12 55 170 160 170 10 5 230 DDR2 1066 x8 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD mA mA mA mA mA mA mA mA mA mA mA mA mA mA
Symbol
Units
IDD7
Note : Product list Part No. H5PS1G83EFR-xx*C H5PS1G83EFR-xx*I H5PS1G83EFR-xx*L 128Mx8 Configuration Power Consumption Normal Consumption Normal Consumption Low Power Consumption (IDD6 Only) Low Power Consumption (IDD6 Only) Operation Temp Commercial Industrial Commercial 60 Ball fBGA Package
H5PS1G83EFR-xx*J
Industrial
Rev. 1.0 / Aug 2009
15
Release H5PS1G83EFR Series
3.4 IDD Specifications & Test Conditions IDD Specifications(max) - II
Symbol IDD0 IDD1 IDD2P IDD2Q IDD2N IDD3P IDD3N IDD4W IDD4R IDD5 IDD6 IDD7 F S DDR2 667 x8 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD DDR2 800 x8 TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD TBD Units mA mA mA mA mA mA mA mA mA mA mA mA mA
Note : Product list Part No. H5PS1G83EFR-xx*P H5PS1G83EFR-xx*Q 128Mx8 Low Current Consumption Industrial Configuration Power Consumption Low Current Consumption Operation Temp Commercial Package 60 Ball fBGA
Rev. 1.0 / Aug 2009
16
Release H5PS1G83EFR Series IDD Test Conditions
(IDD values are for full operating range of Voltage and Temperature, Notes 1-5)
Symbol IDD0 Conditions Operating one bank active-precharge current; tCK = tCK(IDD), tRC = tRC(IDD), tRAS = tRAS min(IDD); CKE is HIGH, CS is HIGH between valid commands;Address bus inputs are SWITCHING;Data bus inputs are SWITCHING Operating one bank active-read-precharge current; IOUT = 0mA;BL = 4, CL = CL(IDD), AL = 0; tCK = tCK(IDD), tRC = tRC (IDD), tRAS = tRASmin(IDD), tRCD = tRCD(IDD); CKE is HIGH, CS is HIGH between valid commands; Address bus inputs are SWITCHING; Data pattern is same as IDD4W Precharge power-down current; All banks idle; tCK = tCK(IDD); CKE is LOW; Other control and address bus inputs are STABLE; Data bus inputs are FLOATING Precharge quiet standby current;All banks idle; tCK = tCK(IDD);CKE is HIGH, CS is HIGH; Other control and address bus inputs are STABLE; Data bus inputs are FLOATING Precharge standby current; All banks idle; tCK = tCK(IDD); CKE is HIGH, CS is HIGH; Other control and address bus inputs are SWITCHING; Data bus inputs are SWITCHING Active power-down current; All banks open; tCK = tCK(IDD); CKE is LOW; Other control and address bus inputs are STABLE; Data bus inputs are FLOATING Fast PDN Exit MR(12) = 0 Slow PDN Exit MR(12) = 1 Units mA
IDD1
mA
IDD2P IDD2Q IDD2N
mA mA mA mA mA
IDD3P
IDD3N
Active standby current; All banks open; tCK = tCK(IDD), tRAS = tRASmax(IDD), tRP =tRP(IDD); CKE is HIGH, CS is HIGH between valid commands; Other control and address bus inputs are SWITCHING; Data bus inputs are SWITCHING Operating burst write current; All banks open, Continuous burst writes; BL = 4, CL = CL(IDD), AL = 0; tCK = tCK(IDD), tRAS = tRASmax(IDD), tRP = tRP(IDD); CKE is HIGH, CS is HIGH between valid commands; Address bus inputs are SWITCHING; Data bus inputs are SWITCHING Operating burst read current; All banks open, Continuous burst reads, IOUT = 0mA; BL = 4, CL = CL(IDD), AL = 0; tCK = tCK(IDD), tRAS = tRASmax(IDD), tRP = tRP(IDD); CKE is HIGH, CS is HIGH between valid commands; Address bus inputs are SWITCHING; Data pattern is same as IDD4W Burst refresh current; tCK = tCK(IDD); Refresh command at every tRFC(IDD) interval; CKE is HIGH, CS is HIGH between valid commands; Other control and address bus inputs are SWITCHING; Data bus inputs are SWITCHING Self refresh current; CK and CK at 0V; CKE ≤ 0.2V; Other control and address bus inputs are FLOATING; Data bus inputs are FLOATING Operating bank interleave read current; All bank interleaving reads, IOUT = 0mA; BL = 4, CL = CL(IDD), AL = tRCD(IDD)-1*tCK(IDD); tCK = tCK(IDD), tRC = tRC(IDD), tRRD = tRRD(IDD), tRCD = 1*tCK(IDD); CKE is HIGH, CS is HIGH between valid commands; Address bus inputs are STABLE during DESELECTs; Data pattern is same as IDD4R; - Refer to the following page for detailed timing conditions
mA
IDD4W
mA
IDD4R
mA
IDD5B
mA
IDD6
mA
IDD7
mA
Rev. 1.0 / Aug 2009
17
Release H5PS1G83EFR Series
Note : 1. VDDQ = 1.8 +/- 0.1V ; VDD = 1.8 +/- 0.1V (exclusively VDDQ = 1.9 +/- 0.1V ; VDD = 1.9 +/- 0.1V for C3 speed grade) 2. IDD specifications are tested after the device is properly initialized 3. Input slew rate is specified by AC Parametric Test Condition 4. IDD parameters are specified with ODT disabled. 5. Data bus consists of DQ, DM, DQS, DQS, RDQS, RDQS, LDQS, LDQS, UDQS, and UDQS. IDD values must be met with all combinations of EMR bits 10 and 11. 6. For DDR2-667/800 testing, tCK in the COnditions should be interpreted as tCK (avg). 7. Definitions for IDD LOW is defined as Vin ≤ VILAC (max) HIGH is defined as Vin ≥ VIHAC (min) STABLE is defined as inputs stable at a HIGH or LOW level FLOATING is defined as inputs at VREF = VDDQ/2 SWITCHING is defined as: inputs changing between HIGH and LOW every other clock cycle (once per two clocks) for address and control signals, and inputs changing between HIGH and LOW every other data transfer (once per clock) for DQ signals not including masks or strobes.
Rev. 1.0 / Aug 2009
18
Release H5PS1G83EFR Series IDD Testing Parameters
For purposes of IDD testing, the following parameters are to be utilized. DDR2-800 Parameter CL(IDD) tRCD(IDD) tRC(IDD) tRRD(IDD)-x4/x8 tRRD(IDD)-x16 tCK(IDD) tRASmin(IDD) tRASmax(IDD) tRP(IDD) tRFC(IDD)-256Mb tRFC(IDD)-512Mb tRFC(IDD)-1Gb tRFC(IDD)-2Gb 5-5-5 5 12.5 57.5 7.5 10 2.5 45 70000 12.5 75 105 127.5 197.5 6-6-6 6 15 60 7.5 10 2.5 45 70000 15 75 105 127.5 197.5 DDR2667 5-5-5 5 15 60 7.5 10 3 45 70000 15 75 105 127.5 197.5 DDR2533 4-4-4 4 15 60 7.5 10 3.75 45 70000 15 75 105 127.5 197.5 DDR2400 3-3-3 3 15 55 7.5 10 5 40 70000 15 75 105 127.5 197.5 Units tCK ns ns ns ns ns ns ns ns ns ns ns ns
Detailed IDD7 The detailed timings are shown below for IDD7. Changes will be required if timing parameter changes are made to the specification. Legend: A = Active; RA = Read with Autoprecharge; D = Deselect IDD7: Operating Current: All Bank Interleave Read operation All banks are being interleaved at minimum tRC(IDD) without violating tRRD(IDD) and tFAW (IDD) using a burst length of 4. Control and address bus inputs are STABLE during DESELECTs. IOUT = 0mA Timing Patterns for 4 bank devices x4/ x8/ x16 -DDR2-400 4/4/4: A0 RA0 A1 RA1 A2 RA2 A3 RA3 D D D D D -DDR2-400 3/3/3: A0 RA0 A1 RA1 A2 RA2 A3 RA3 D D D D -DDR2-533 4/4/4: A0 RA0 D A1 RA1 D A2 RA2 D A3 RA3 D D D -DDR2-533 4/4/4: A0 RA0 D A1 RA1 D A2 RA2 D A3 RA3 D D D -DDR2-667 5/5/5: A0 RA0 D D A1 RA1 D D A2 RA2 D D A3 RA3 -DDR2-667 4/4/4: A0 RA0 D D A1 RA1 D D A2 RA2 D D A3 RA3 -DDR2-800 6/6/6: A0 RA0 D D A1 RA1 D D A2 RA2 D D A3 RA3 -DDR2-800 5/5/5: A0 RA0 D D A1 RA1 D D A2 RA2 D D A3 RA3 -DDR2-800 4/4/4: A0 RA0 D D A1 RA1 D D A2 RA2 D D A3 RA3
DD DD DD DD DD DD DD
DDD DDD DDD DDD DDD
D DDDDD DDDD DDD
Timing Patterns for 8 bank devices x4/8 -DDR2-400 all bins: A0 RA0 A1 RA1 A2 RA2 A3 RA3 A4 RA4 A5 RA5 A6 RA6 A7 RA7 -DDR2-533 all bins: A0 RA0 A1 RA1 A2 RA2 A3 RA3 D D A4 RA4 A5 RA5 A6 RA6 A7 RA7 D D -DDR2-667 all bins: A0 RA0 D A1 RA1 D A2 RA2 D A3 RA3 D D A4 RA4 D A5 RA5 D A6 RA6 D A7 RA7 D D -DDR2-800 all bins: A0 RA0 D A1 RA1 D A2 RA2 D A3 RA3 D D D A4 RA4 D A5 RA5 D A6 RA6 D A7 RA7 D D D
Rev. 1.0 / Aug 2009
19
Release H5PS1G83EFR Series
Timing Patterns for 8 bank devices x16 -DDR2-400 all bins: A0 RA0 A1 RA1 A2 RA2 A3 RA3 D D A4 RA4 A5 RA5 A6 RA6 A7 RA7 D D -DDR2-533 all bins: A0 RA0 D A1 RA1 D A2 RA2 D A3 RA3 D D D A4 RA4 D A5 D A6 RA6 D A7 RA7 D D D -DDR2-667 all bins: A0 RA0 D D A1 RA1 D D A2 RA2 D D A3 RA3 D D D A4 RA4 D D A5 RA5 D D A6 RA6 D D A7 RA7 DDD -DDR2-800 all bins: A0 RA0 D D A1 RA1 D D A2 RA2 D D A3 RA3 D D D D A4 RA4 D D A5 RA5 D D A6 RA6 D D A7 RA7 DDDD
3.5. Input/Output Capacitance
DDR2 400 DDR2 533 Min Input capacitance, CK and CK Input capacitance delta, CK and CK Input capacitance, all other input-only pins Input capacitance delta, all other input-only pins Input/output capacitance, DQ, DM, DQS, DQS Input/output capacitance delta, DQ, DM, DQS, DQS CCK CDCK CI CDI CIO CDIO 1.0 x 1.0 x 2.5 x Max 2.0 0.25 2.0 0.25 4.0 0.5 DDR2 667 DDR2 800 Units Min 1.0 x 1.0 x 2.5 x Max 2.0 0.25 2.0 0.25 3.5 0.5 Min 1.0 x 1.0 x 2.5 x Max 2.0 0.25 1.75 0.25 3.5 0.5 pF pF pF pF pF pF
Parameter
Symbol
Rev. 1.0 / Aug 2009
20
Release H5PS1G83EFR Series
4. Electrical Characteristics & AC Timing Specification
(TOPER; VDDQ = 1.8 +/- 0.1V; VDD = 1.8 +/- 0.1V)
Refresh Parameters by Device Density
Parameter Refresh to Active/Refresh command time Average periodic refresh interval
Note: 1: If refresh timing is violated, data corruption may occur and the data must be re-written with valid data before a valid READ can be executed. 2. This is an optional feature. For detailed information, please refer to “operating temperature condition” in this data sheet.
Symbol tRFC 0 ℃ ≤ TCASE ≤ 85℃ tREFI 85℃< T CASE ≤ 95 ℃
256Mb 512Mb 1Gb 75 7.8 3.9 105 7.8 3.9 127.5 7.8 3.9
2Gb 195 7.8 3.9
4Gb 327.5 7.8 3.9
Units Notes ns us us 1 1 1,2
DDR2 SDRAM speed bins and tRCD, tRP and tRC for corresponding bin
Speed Parameter Bin(CL-tRCD-tRP) CAS Latency tRCD tRP
*1
DDR2-800 min 5-5-5 5 12.5 12.5 45 57.5 min 6-6-6 6 15 15 45 60
DDR2-667 min 4-4-4 4 12 12 45 57 min 5-5-5 5 15 15 45 60
DDR2-533 min 4-4-4 4 15 15 45 60
DDR2-400 min 3-3-3 3 15 15 40 55
Units Notes
tCK ns ns ns ns 2 2 2,3 2
tRAS tRC
Note:
1. 8 bank device Precharge All Allowance: tRP for a Precharge All command for an 8 Bank device will equal to tRP+1*tCK, where tRP are the values for a single bank Precharge, which are shown in the table above. 2. Refer to Specific Notes 32. 3. Refer to Specific Notes 3.
Rev. 1.0 / Aug 2009
21
Release H5PS1G83EFR Series
Timing Parameters by Speed Grade (DDR2-400 and DDR2-533)
Parameter
DQ output access time from CK/CK DQS output access time from CK/CK CK HIGH pulse width CK LOW pulse width CK half period Clock cycle time, CL=x DQ and DM input setup time(differential strobe)
Symbol
DDR2-400 min max
+600 +500 0.55 0.55 -
DDR2-533 min
-500 -450 0.45 0.45 min(tCL, tCH) 3750 100
Unit
Note
max
+500 +450 0.55 0.55 ps ps tCK tCK ps 11,12
tAC tDQSCK tCH tCL tHP
-600 -500 0.45 0.45 min(tCL, tCH) 5000 150
tCK tDS(base)
8000 -
8000 -
ps ps
15 6,7,8,20 ,28 6,7,8,21 ,28 6,7,8,25 6,7,8,26
DQ and DM input hold time(differential strobe) DQ and DM input setup time(single ended strobe) DQ and DM input hold time(single ended strobe) Control & Address input pulse width for each input DQ and DM input pulse width for each input Data-out high-impedance time from CK/CK DQS low-impedance time from CK/CK
tDH(base) tDS(base) tDH(base) tIPW tDIPW tHZ tLZ (DQS) tLZ (DQ) tDQSQ tQHS tQH tDQSS tDQSH tDQSL tDSS tDSH tMRD tWPRE tWPST tIS tIH tRPRE tRPST
275 25 25 0.6 0.35 tAC min
tAC max tAC max
225 -25 -25 0.6 0.35 tAC min
tAC max tAC max
ps ps ps tCK tCK ps ps
18 18
DQ low-impedance time from CK/CK DQS-DQ skew for DQS and associated DQ signals DQ hold skew factor DQ/DQS output hold time from DQS Write command to first DQS latching transition DQS input HIGH pulse width DQS input LOW pulse width DQS falling edge to CK setup time DQS falling edge hold time from CK Mode register set command cycle time Write preamble Write postamble Address and control input setup time Address and control input hold time Read preamble Read postamble
2*tAC min
tAC max
2*tAC min
tAC max
ps
18
tHP - tQHS WL - 0.25 0.35 0.35 0.2 0.2 2 0.35 0.4 350 475 0.9 0.4
350 450 WL + 0.25 0.6 1.1 0.6
tHP - tQHS WL - 0.25 0.35 0.35 0.2 0.2 2 0.35 0.4 250 375 0.9 0.4
300 400 WL + 0.25 0.6 1.1 0.6
ps ps ps tCK tCK tCK tCK tCK tCK tCK tCK ps ps tCK tCK ns
13 12
10 5,7,9,23 5,7,9,23 19 19 4
Active to active command period for 1KB page size products (x4, x8) Active to active command period for 2KB page size products (x16) Rev. 1.0 / Aug 2009
tRRD
7.5
-
7.5
-
tRRD
10
-
10
-
ns
4
22
Release H5PS1G83EFR Series -ContinuedParameter Four Active Window for 1KB page size products Four Active Window for 2KB page size products CAS to CAS command delay Write recovery time Auto precharge write recovery + precharge time Internal write to read command delay Internal read to precharge command delay Exit self refresh to a non-read command Exit self refresh to a read command Exit precharge power down to any nonread command Exit active power down to read command Exit active power down to read command (Slow exit, Lower power) CKE minimum pulse width (HIGH and LOW pulse width) ODT turn-on delay ODT turn-on Symbol DDR2-400 min tFAW 37.5 max DDR2-533 min 37.5 max ns
Units
Notes
tFAW tCCD tWR tDAL tWTR tRTP tXSNR tXSRD tXP tXARD tXARDS tCKE tAOND tAON
50 2 15 WR+tRP* 10 7.5 tRFC + 10 200 2 2 6 - AL 3 2 tAC(min) tAC(min)+ 2 2.5 tAC(min) tAC(min)+ 2 3 8 0 tIS+tCK+tI H
-
50 2
-
ns
tCK ns tCK ns ns ns tCK tCK tCK tCK tCK 2 tAC(max) +1 2tCK+tA C(max)+1 2.5 tAC(max) + 0.6 2.5tCK+t AC(max) +1 tCK ns 1 1, 2 27 16 16 14 24 3
-
15 WR+tRP* 7.5 7.5 tRFC + 10
-
200 2 2 6 - AL 3
2 tAC(max) +1 2tCK+tAC (max) +1 2.5 tAC(max) + 0.6 2.5tCK+tA C(max)+1
2 tAC(min) tAC(min)+ 2 2.5 tAC(min) tAC(min)+ 2 3 8
ODT turn-on(Power-Down mode) ODT turn-off delay ODT turn-off
tAONPD tAOFD tAOF
ns tCK ns 17,44 17,44
ODT turn-off (Power-Down mode) ODT to power down entry latency ODT power down exit latency OCD drive mode output delay Minimum time clocks remains ON after CKE asynchronously drops LOW
tAOFPD tANPD tAXPD tOIT tDelay
ns tCK tCK
12
0 tIS+tCK+tI H
12
ns ns 15
Rev. 1.0 / Aug 2009
23
Release H5PS1G83EFR Series
(DDR2-667 and DDR2-800)
Parameter
DQ output access time from CK/CK DQS output access time from CK/CK CK HIGH pulse width CK LOW pulse width CK half period Clock cycle time, CL=x DQ and DM input setup time DQ and DM input hold time Control & Address input pulse width for each input DQ and DM input pulse width for each input Data-out high-impedance time from CK/CK DQS low-impedance time from CK/CK DQ low-impedance time from CK/CK DQS-DQ skew for DQS and associated DQ signals DQ hold skew factor DQ/DQS output hold time from DQS First DQS latching transition to associated clock edge DQS input HIGH pulse width DQS input LOW pulse width DQS falling edge to CK setup time DQS falling edge hold time from CK Mode register set command cycle time Write preamble Write postamble Address and control input setup time Address and control input hold time Read preamble Read postamble Activate to precharge command Active to active command period for 1KB page size products (x4, x8) Active to active command period for 2KB page size products (x16) Four Active Window for 1KB page size products Four Active Window for 2KB page size products CAS to CAS command delay Write recovery time Auto precharge write recovery + precharge time
Symbol
tAC tDQSCK tCH(avg) tCL(avg) tHP tCK(avg) tDS(base) tDH(base) tIPW tDIPW tHZ tLZ(DQS) tLZ(DQ) tDQSQ tQHS tQH tDQSS tDQSH tDQSL tDSS tDSH tMRD tWPRE tWPST tIS(base) tIH(base) tRPRE tRPST tRAS tRRD tRRD tFAW tFAW tCCD tWR tDAL
DDR2-667 min
-450 -400 0.48 0.48 min(tCL(abs), tCH(abs)) 3000 100 175 0.6 0.35 tAC min 2*tAC min tHP - tQHS - 0.25 0.35 0.35 0.2 0.2 2 0.35 0.4 200 275 0.9 0.4 45 7.5 10 37.5 50 2 15 WR+tnRP -
DDR2-800 min
-400 -350 0.48 0.48 min(tCL(abs), tCH(abs)) 2500 50 125 0.6 0.35 tAC min 2*tAC min tHP - tQHS - 0.25 0.35 0.35 0.2 0.2 2 0.35 0.4 175 250 0.9 0.4 45 7.5 10 35 45 2 15 WR+tnRP -
Unit
ps ps tCK(avg) tCK(avg) ps ps ps ps tCK(avg) tCK(avg) ps ps ps ps ps ps tCK(avg) tCK(avg) tCK(avg) tCK(avg) tCK(avg) tCK(avg) tCK(avg) tCK(avg) ps ps tCK(avg) tCK(avg) ns ns ns ns ns nCK ns nCK
Note
40 40 35,36 35,36 37 35,36 6,7,8,20,28,31 6,7,8,21,28,31
max
+450 +400 0.52 0.52 8000 tAC max tAC max tAC max 240 340 + 0.25 0.6 1.1 0.6 70000 -
max
+400 +350 0.52 0.52 8000 tAC max tAC max tAC max 200 300 + 0.25 0.6 1.1 0.6 70000 -
18,40 18,40 18,40 13 38 39 30
30 30
10 5,7,9,22,29 5,7,9,23,29 19,41 19,42 3 4,32 4,32 32 32
32 33
Rev. 1.0 / Aug 2009
24
Release H5PS1G83EFR Series -ContinuedSymbol
tWTR tRTP tXSNR tXSRD tXP tXARD tXARDS tCKE tAOND tAON tAONPD tAOFD tAOF tAOFPD tANPD tAXPD tOIT tDelay 7.5 7.5 tRFC + 10 200 2 2 7 - AL 3 2 tAC(min) tAC(min)+2 2.5 tAC(min) tAC(min) +2 3 8 0 tIS + tCK (avg) + tIH 12 2 tAC(max) +0.7 2tCK(avg)+ tAC(max)+1 2.5 tAC(max)+ 0.6 2.5tCK(avg)+ tAC(max)+1 -
Parameter
Internal write to read command delay Internal read to precharge command delay Exit self refresh to a non-read command Exit self refresh to a read command Exit precharge power down to any non-read command Exit active power down to read command Exit active power down to read command (Slow exit, Lower power) CKE minimum pulse width (HIGH and LOW pulse width) ODT turn-on delay ODT turn-on ODT turn-on(Power-Down mode) ODT turn-off delay ODT turn-off ODT turn-off (Power-Down mode) ODT to power down entry latency ODT power down exit latency OCD drive mode output delay Minimum time clocks remains ON after CKE asynchronously drops LOW
DDR2-667 min max
-
DDR2-800 min
7.5 7.5 tRFC + 10 200 2 2 8 - AL 3 2 tAC(min) tAC(min) +2 2.5 tAC(min) tAC(min) +2 3 8 0 tIS + tCK (avg) + tIH 12 2 tAC(max) +0.7 2tCK(avg)+ tAC(max)+1 2.5 tAC(max) +0.6 2.5tCK(avg)+ tAC(max)+1 -
Unit
ns ns ns nCK nCK nCK nCK nCK nCK ns ns nCK ns ns nCK nCK ns ns
Notes
24,32 3,32 32
max
-
1 1, 2 27 16 6,16,40
17,45 17,43,4 5
32 15
Rev. 1.0 / Aug 2009
25
Release H5PS1G83EFR Series
General notes, which may apply for all AC parameters
1. DDR2 SDRAM AC timing reference load The following figure represents the timing reference load used in defining the relevant timing parameters of the part. It is not intended to be either a precise representation of the typical system environment nor a depiction of the actual load presented by a production tester. System designers will use IBIS or other simulation tools to correlate the timing reference load to a system environment. Manufacturers will correlate to their production test conditions (generally a coaxial transmission line terminated at the tester electronics).
VDDQ
DQ DQS DQS RDQS RDQS
DUT
Output Timing reference point 25Ω
VTT = VDDQ/2
AC Timing Reference Load
The output timing reference voltage level for single ended signals is the crosspoint with VTT. The output timing reference voltage level for differential signals is the crosspoint of the true (e.g. DQS) and the complement (e.g. DQS) signal. 2. Slew Rate Measurement Levels a. Output slew rate for falling and rising edges is measured between VTT - 250 mV and VTT + 250 mV for single ended signals. For differential signals (e.g. DQS - DQS) output slew rate is measured between DQS - DQS = -500 mV and DQS - DQS = +500mV. Output slew rate is guaranteed by design, but is not necessarily tested on each device. b. Input slew rate for single ended signals is measured from dc-level to ac-level: from VREF - 125 mV to VREF + 250 mV for rising edges and from VREF + 125 mV and VREF - 250 mV for falling edges. For differential signals (e.g. CK - CK) slew rate for rising edges is measured from CK - CK = -250 mV to CK - CK = +500 mV (+250mV to -500 mV for falling edges). c. VID is the magnitude of the difference between the input voltage on CK and the input voltage on CK, or between DQS and DQS for differential strobe.
3. DDR2 SDRAM output slew rate test load Output slew rate is characterized under the test conditions as shown below.
VDDQ DUT
DQ DQS, DQS RDQS, RDQS
Output Test point 25Ω
VTT = VDDQ/2
Slew Rate Test Load
Rev. 1.0 / Aug 2009
26
Release H5PS1G83EFR Series
4. Differential data strobe DDR2 SDRAM pin timings are specified for either single ended mode or differential mode depending on the setting of the EMR “Enable DQS” mode bit; timing advantages of differential mode are realized in system design. The method by which the DDR2 SDRAM pin timings are measured is mode dependent. In single ended mode, timing relationships are measured relative to the rising or falling edges of DQS crossing at VREF. In differential mode, these timing relationships are measured relative to the crosspoint of DQS and its complement, DQS. This distinction in timing methods is guaranteed by design and characterization. Note that when differential data strobe mode is disabled via the EMR, the complementary pin, DQS, must be tied externally to VSS through a 20 Ω to 10 KΩ resistor to insure proper operation.
DQS
tDQSH
tDQSL
DQS/ DQS
DQS tWPRE VIH(ac) VIH(dc) D VIL(ac) tDS tDS VIH(ac) DMin VIL(ac) tDH DMin D D VIL(dc) tDH DMin VIL(dc) VIH(dc) D tWPST
DQ
DM
DMin
Figure -- Data input (write) timing
tCH CK
tCL
CK/CK
CK
DQS
DQS/DQS
DQS tRPRE tRPST Q tDQSQmax tQH Q Q tDQSQmax tQH Q
DQ
Figure -- Data output (read) timing
5. AC timings are for linear signal transitions. See System Derating for other signal transitions. 6. All voltages referenced to VSS. 7. These parameters guarantee device behavior, but they are not necessarily tested on each device. They may be guaranteed by device design or tester correlation. 8. Tests for AC timing, IDD, and electrical (AC and DC) characteristics, may be conducted at nominal reference/supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified.
Rev. 1.0 / Aug 2009 27
Release H5PS1G83EFR Series
Specific Notes for dedicated AC parameters
1. User can choose which active power down exit timing to use via MRS(bit 12). tXARD is expected to be used for fast active power down exit timing. tXARDS is expected to be used for slow active power down exit timing where a lower power value is defined by each vendor data sheet. 2. AL = Additive Latency 3. This is a minimum requirement. Minimum read to precharge timing is AL + BL/2 providing the tRTP and tRAS(min) have been satisfied. 4. A minimum of two clocks (2 * tCK or 2 * nCK) is required irrespective of operating frequency 5. Timings are specified with command/address input slew rate of 1.0 V/ns. See System Derating for other slew rate values. 6. Timings are guaranteed with DQs, DM, and DQS’s(DQS/RDQS in singled ended mode) input slew rate of 1.0 V/ns. See System Derating for other slew rate values. 7. Timings are specified with CK/CK differential slew rate of 2.0 V/ns. Timings are guaranteed for DQS signals with a differential slew rate of 2.0 V/ns in differential strobe mode and a slew rate of 1V/ns in single ended mode. See System Derating for other slew rate values. 8. tDS and tDH derating
tD S , tD H D e rat in g V alu e s fo r D D R 2 -4 00 , D D R 2 -5 33 (A L L u n it s in 'p s' , N o te 1 ap p lie s to e n tir e T a b le) D Q S , D Q S D iffe re n tia l Sle w R a te 4 .0 V /n s △ △ tD S t D H 1 25 45 83 0 21 0 3 .0 V /n s △ △ tDS tDH 125 45 83 0 -11 21 0 -1 4 2.0 V/n s △ △ t D S tD H + 12 5 + 4 5 +83 0 -1 1 -2 5 +21 0 - 14 - 31 1 .8 V /n s △ △ tD S tD H 95 12 1 -1 3 -3 1 33 12 -2 -1 9 -4 2 1 .6 V /n s △ △ tD S t D H 24 13 -1 - 19 - 43 24 10 -7 -1 9 -5 9 1.4 V/n s △ △ t D S tD H 25 11 -7 -3 1 -7 4 22 5 -8 - 47 - 89 1.2 V /n s △ △ tD S tD H 23 5 -1 9 -6 2 -1 2 7 17 -6 -3 5 -7 7 -1 40 1 .0 V /n s △ △ tD S t D H 17 -7 - 50 - 11 5 6 -2 3 -6 5 -1 2 8 0 .8 V /n s △ △ tD S t D H 5 -38 -1 03 -1 1 -5 3 - 11 6
2 .0 1 .5 1 .0 DQ S le w rat e V /n s 0 .9 0 .8 0 .7 0 .6 0 .5 0 .4
tD S, t D H D e ra tin g V a lu es fo r D D R 2 -6 6 7, D D R 2 -8 0 0( A L L u n it s in ' p s ', N o t e 1 a p p lies to e nt ire T a b le ) D QS , D Q S D iff ere n t ia l S le w R a t e 4 .0 V /n s △ t DS 2 .0 1 .5 1 .0 DQ S le w rat e V /n s 0 .9 0 .8 0 .7 0 .6 0 .5 0 .4 100 67 0 △ tDH 45 21 0 3.0 V /n s △ t DS 100 67 0 -5 △ t DH 45 21 0 -1 4 2.0 V /n s △ tD S 100 67 0 -5 - 13 △ tDH 45 21 0 -1 4 -3 1 1.8 V/n s △ tD S 79 12 7 -1 - 10 △ t DH 33 12 -2 -1 9 -4 2 1.6 V/n s △ tD S 24 19 11 2 - 10 △ tD H 24 10 -7 -3 0 -5 9 1 .4 V/n s △ tD S 31 23 14 2 - 24 △ tD H 22 5 -1 8 -4 7 -8 9 1 .2 V /n s △ tD S 35 26 14 -1 2 -5 2 △ tD H 17 -6 -3 5 -7 7 -1 40 1 .0 V /n s △ tD S 38 26 0 -4 0 △ tD H 6 - 23 - 65 -1 28 0 .8 V /ns △ tD S 38 12 -2 8 △ tD H - 11 - 53 - 1 16
Rev. 1.0 / Aug 2009
28
Release H5PS1G83EFR Series
tD S, t DH De ra ting Va lues fo r D DR2-4 00, D DR2 -53 3( ALL un it s in 'ps ', Not e 1 a pplies to e nt ire Table) D Q S, Sin g le -ended Slew R at e 2 .0 V /ns △ t DS 2.0 1.5 1.0 DQ Sle w rat e V/ns 0.9 0.8 0.7 0.6 0.5 0.4 18 8 14 6 63 △ t DH 1 88 1 67 1 25 1.5 V/n s △ t DS 167 125 42 31 △ t DH 14 6 12 5 83 69 1.0 V/n s △ tD S 12 5 83 0 - 11 - 25 △ t DH 63 42 0 -14 -31 0.9 V/n s △ tD S 81 -2 - 13 - 27 - 45 △ t DH 43 1 -1 3 -3 0 -5 3 0.8 V/ns △ tD S -7 - 18 - 32 - 50 - 74 △ tD H -1 3 -2 7 -4 4 -6 7 -9 6 0 .7 V/ns △ tDS - 29 - 43 - 61 - 85 △ tD H -4 5 -6 2 -8 5 0.6 V/ns △ tDS -6 0 -7 8 △ tD H -8 6 0 .5 V/ns △ tDS △ tDH 0 .4 V/ns △ tDS △ tDH -
-1 09 - 108 -152
-11 4 - 10 2 -1 38 - 132 -181 -18 3 - 2 48 - 21 0 -2 43 - 240 -286 -29 1 - 3 51
- 128 -15 6 - 14 5 -1 80 - 175 -223 -22 6 - 2 88
1) For all input signals the total tDS(setup time) and tDH(hold time) required is calculated by adding the datasheet value to the derating value listed in Table x. Setup(tDS) nominal slew rate for a rising signal is defined as the slew rate between the last crossing of VREF(dc) and the first crossing of Vih(ac)min. Setup(tDS) nominal slew rate for a falling signal is defined as the slew rate between the last crossing of VREF(dc) and the first crossing of Vil(ac)max. If the actual signal is always earlier than the nominal slew rate line between shaded ‘ VREF(dc) to ac region’, use nominal slew rate for derating value(see Fig a.) If the actual signal is later than the nominal slew rate line anywhere between shaded ‘VREF(dc) to ac region’, the slew rate of a tangent line to the actual signal from the ac level to dc level is used for derating value(see Fig b.) Hold(tDH) nominal slew rate for a rising signal is defined as the slew rate between the last crossing of Vil(dc) max and the first crossing of VREF(dc). Hold (tDH) nominal slew rate for a falling signal is defined as the slew rate between the last crossing of Vih(dc) min and the first crossing of VREF(dc). If the actual signal is always later than the nominal slew rate line anywhere between shaded ‘dc to VREF(dc) region’, the slew rate of a tangent line to the actual signal from the dc level to VREF(dc) level is used for derating value(see Fig c.) If the actual signal is earlier than the nominal slew rate line anywhere between shaded ‘dc to VREF(dc) region’, the slew rate of a tangent line to the actual signal from the dc level to VREF(dc) level is used for derating value(see Fig d.) Although for slow slew rates the total setup time might be negative(i.e. a valid input signal will not have reached VIH/IL(ac) at the time of the rising clock transition) a valid input signal is still required to complete the transition and reach VIH/IL(ac). For slew rate in between the values listed in table x, the derating valued may obtained by linear interpolation. These values are typically not subject to production test. They are verified by design and characterization.
Rev. 1.0 / Aug 2009
29
Release H5PS1G83EFR Series
If the actual signal is earlier than the nominal slew rate line anywhere between shaded ‘dc to VREF(dc) region’, the slew rate of a tangent line to the actual signal from the dc level to VREF(dc) level is used for derating value(see Fig d.) Although for slow rates the total setup time might be negative(i.e. a valid input signal will not have reached VIH/IL(ac) at the time of the rising clock transition) a valid input signal is still required to complete the transition and reach VIH/IL(ac). For slew rates in between the values listed in table, the derating values may obtained by linear interpolation. These values are typically not subject to production test. They are verified by design and characterization.
Rev. 1.0 / Aug 2009
30
Release H5PS1G83EFR Series
Fig. a. Illustration of nominal slew rate for tIS,tDS
CK,DQS CK, DQS tIS, tDS VDDQ tIH, tDH tIS, tDS tIH, tDH
VIH(ac)min
VIH(dc)min
nominal slew rate
VREF(dc) nominal slew rate VREF to ac region
VIL(dc)max
VIL(ac)max Vss
Delta TF Setup Slew Rate = Falling Signal VREF(dc)-VIL(ac)max Delta TF
Delta TR Setup Slew Rate = Rising Signal VIH(ac)min-VREF(dc) Delta TR
Rev. 1.0 / Aug 2009
31
Release H5PS1G83EFR Series
Fig. b. Illustration of tangent line for tIS,tDS
CK, DQS CK, DQS tIS, tDS VDDQ nominal line VIH(ac)min tIH, tDH tIS, tDS tIH, tDH
VIH(dc)min tangent line VREF(dc) Tangent line VIL(dc)max VREF to ac region VIL(ac)max Nomial line Vss Delta TF
Delta TR Setup Slew Rate Tangent line[VIH(ac)min-VREF(dc)] = Rising Signal Delta TR
Setup Slew Rate Tangent line[VREF(dc)-VIL(ac)max] = Falling Signal Delta TF
Rev. 1.0 / Aug 2009
32
Release H5PS1G83EFR Series
Fig. c. Illustration of nominal line for tIH, tDH
CK, DQS CK, DQS tIS, tDS VDDQ tIH, tDH tIS, tDS tIH, tDH
VIH(ac)min
VIH(dc)min dc to VREF region VREF(dc) nominal slew rate nominal slew rate
VIL(dc)max
VIL(ac)max
Vss Delta TR Hold Slew Rate = Rising Signal VREF(dc)-VIL(dc)max Delta TR Delta TF
VIH(dc)min - VREF(dc) Hold Slew Rate = Falling Signal Delta TF
Rev. 1.0 / Aug 2009
33
Release H5PS1G83EFR Series
Fig. d. Illustration of tangent line for tIH, tDH
CK, DQS CK, DQS
tIS, tDS
VDDQ
tIH, tDH
tIS, tDS
tIH, tDH
VIH(ac)min nominal line VIH(dc)min tangent line VREF(dc) dc to VREF region VIL(dc)max Tangent line nominal line
VIL(ac)max
Vss Delta TR Hold Slew Rate Tangent line[VREF(dc)-VIL(ac)max] = Rising Signal Delta TR Tangent line[VIH(ac)min-VREF(dc)] Hold Slew Rate = Falling Signal Delta TF Delta TF
Rev. 1.0 / Aug 2009
34
Release H5PS1G83EFR Series
9. tIS and tIH (input setup and hold) derating
tIS, tIH Derating Values for DDR2-400, DDR2-533 CK, CK Differential Slew Rate 2.0 V/ns △ tIS
4.0 3.5 3.0 2.5 2.0 1.5 1.0 +187 +179 +167 +150 +125 +83 +0 -11 -25 -43 -67 -110 -175 -285 -350 -525 -800 -1450
1.5 V/ns △ tIS
+217 +209 +197 +180 +155 +113 +30 +19 +5 -13 -37 -80 -145 -255 -320 -495 -770 -1420
1.0 V/ns △ tIS
+247 +239 +227 +210 +185 +143 +60 +49 +35 +17 -7 -80 -115 -225 -290 -465 -740 -1390
△ tIH
+94 +89 +83 +75 +45 +21 0 -14 -31 -54 -83 -125 -188 -292 -375 -500 -708 -1125
△ tIH
+124 +119 +113 +105 +75 +51 +30 +16 -1 -24 -53 -95 -158 -262 -345 -470 -678 -1095
△ tIH
+154 +149 +143 +135 +105 +81 +60 +46 +29 +6 -23 -65 -128 -232 -315 -440 -648 -1065
Uni ts
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
Note s
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Command / 0.8 Address Slew 0.7 rate(V/ns) 0.6
0.5 0.4 0.3 0.25 0.2 0.15 0.1
0.9
Rev. 1.0 / Aug 2009
35
Release H5PS1G83EFR Series
tIS, tIH Derating Values for DDR2-667, DDR2-800 CK, CK Differential Slew Rate 2.0 V/ns △ tIS
4.0 3.5 3.0 2.5 2.0 1.5 1.0 +15 +143 +133 +120 +100 +67 0 -5 -13 -22 -34 -60 -100 -168 -200 -325 -517 -1000
1.5 V/ns △ tIS
+180 +173 +163 +150 +130 +97 +30 +25 +17 +8 -4 -30 -70 -138 -170 -395 -487 -970
1.0 V/ns △ tIS
+210 +203 +193 +180 +150 +127 +60 +55 +47 +38 +26 0 -40 -108 -140 -265 -457 -940
△ tIH
+94 +89 +83 +75 +45 +21 0 -14 -31 -54 -83 -125 -188 -292 -375 -500 -708 -1125
△ tIH
+124 +119 +113 +105 +75 +51 +30 +16 -1 -24 -53 -95 -158 -262 -345 -470 -678 -1095
△ tIH
+154 +149 +143 +135 +105 +81 +60 +46 +29 +6 -23 -65 -128 -232 -315 -440 -648 -1065
Uni ts
ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps
Note s
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Command / 0.8 Address Slew 0.7 rate(V/ns) 0.6
0.5 0.4 0.3 0.25 0.2 0.15 0.1
0.9
1) For all input signals the total tIS(setup time) and tIH(hold) time) required is calculated by adding the datasheet value to the derating value listed in above Table. Setup(tIS) nominal slew rate for a rising signal is defined as the slew rate between the last crossing of VREF(dc) and the first crossing of VIH(ac)min. Setup(tIS) nominal slew rate for a falling signal is defined as the slew rate between the last crossing of VREF(dc) and the first crossing of VIL(ac)max. If the actual signal is always earlier than the nominal slew rate for line between shaded ‘VREF(dc) to ac region’, use nominal slew rate for derating value(see fig a.) If the actual signal is later than the nominal slew rate line anywhere between shaded ‘VREF(dc) to ac region’, the slew rate of a tangent line to the actual signal from the ac level to dc level is used for derating value(see Fig b.) Hold(tIH) nominal slew rate for a rising signal is defined as the slew rate between the last crossing of VIL(dc)max and the first crossing of VREF(dc). Hold(tIH) nominal slew rate for a falling signal is defined as the slew rate between the last crossing of VREF(dc). If the actual signal is always later than the nominal slew rate line between shaded ‘dc to VREF(dc) region’, use nominal slew rate for derating value(see Fig.c) If the actual signal is earlier than the nominal slew rate line anywhere between shaded ‘dc to VREF(dc) region’, the slew rate of a tangent line to the actual signal from the dc level to VREF(dc) level is used for derating value(see Fig d.) Although for slow rates the total setup time might be negative(i.e. a valid input signal will not have reached VIH/IL(ac) at the time of the rising clock transition) a valid input signal is still required to complete the transition and reach VIH/IL(ac). For slew rates in between the values listed in table, the derating values may obtained by linear interpolation. These values are typically not subject to production test. They are verified by design and characterization.
Rev. 1.0 / Aug 2009 36
Release H5PS1G83EFR Series
10. The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this parameter, but system performance (bus turnaround) will degrade accordingly. 11. MIN (t CL, t CH) refers to the smaller of the actual clock LOW time and the actual clock HIGH time as provided to the device (i.e. this value can be greater than the minimum specification limits for t CL and t CH). For example, t CL and t CH are = 50% of the period, less the half period jitter (t JIT(HP)) of the clock source, and less the half period jitter due to crosstalk (t JIT(crosstalk)) into the clock traces. 12. t QH = t HP – t QHS, where: tHP = minimum half clock period for any given cycle and is defined by clock HIGH or clock LOW (tCH, tCL). tQHS accounts for: 1) The pulse duration distortion of on-chip clock circuits; and 2) The worst case push-out of DQS on one transition followed by the worst case pull-in of DQ on the next transition, both of which are, separately, due to data pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers. 13. tDQSQ: Consists of data pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers as well as output slew rate mismatch between DQS/ DQS and associated DQ in any given cycle. 14. t DAL = (nWR) + (tRP/tCK): For each of the terms above, if not already an integer, round to the next highest integer. tCK refers to the application clock period. nWR refers to the t WR parameter stored in the MR. Example: For DDR533 at t CK = 3.75 ns with t WR programmed to 4 clocks. tDAL = 4 + (15 ns / 3.75 ns) clocks =4 +(4)clocks=8clocks. 15. The clock frequency is allowed to change during self–refresh mode or precharge power-down mode. In case of clock frequency change during precharge power-down, a specific procedure is required as described in section 2.9. 16. ODT turn on time min is when the device leaves high impedance and ODT resistance begins to turn on. ODT turn on time max is when the ODT resistance is fully on. Both are measured from tAOND. 17. ODT turn off time min is when the device starts to turn off ODT resistance. ODT turn off time max is when the bus is in high impedance. Both are measured from tAOFD. 18. tHZ and tLZ transitions occur in the same access time as valid data transitions. These parameters are referenced to a specific voltage level which specifies when the device output is no longer driving (tHZ), or begins driving (tLZ). Below figure shows a method to calculate the point when device is no longer driving (tHZ), or begins driving (tLZ) by measuring the signal at two different voltages. The actual voltage measurement points are not critical as long as the calculation is consistent.
Rev. 1.0 / Aug 2009
37
Release H5PS1G83EFR Series
19. tRPST end point and tRPRE begin point are not referenced to a specific voltage level but specify when the device output is no longer driving (tRPST), or begins driving (tRPRE). Below figure shows a method to calculate these points when the device is no longer driving (tRPST), or begins driving (tRPRE). Below Figure shows a method to calculate these points when the device is no longer driving (tRPST), or begins driving (tRPRE) by measuring the signal at two different voltages. The actual voltage measurement points are not critical as long as the calculation is consistent.
VOH + xmV VOH + 2xmV tHZ tRPST end point T2 T1 VOL + 1xmV VOL + 2xmV
VTT + 2xmV VTT + xmV tLZ tRPRE begin point T1 VTT -xmV VTT - 2xmV T2
tHZ , tRPST end point = 2*T1-T2
tLZ , tRPRE begin point = 2*T1-T2
20. Input waveform timing with differential data strobe enabled MR[bit10] =0, is referenced from the input signal crossing at the VIH(ac) level to the differential data strobe crosspoint for a rising signal, and from the input signal crossing at the VIL(ac) level to the differential data strobe crosspoint for a falling signal applied to the device under test. 21. Input waveform timing with differential data strobe enabled MR[bit10]=0, is referenced from the input signal crossing at the VIH(dc) level to the differential data strobe crosspoint for a rising signal and VIL(dc) to the differential data strobe crosspoint for a falling signal applied to the device under test.
Differential Input waveform timing
DQS
DQS tDS tDH tDS tDH
VDDQ VIH(ac)min VIH(dc)min VREF(dc) VIL(dc)max VIL(ac)max VSS
Rev. 1.0 / Aug 2009
38
Release H5PS1G83EFR Series
22. Input waveform timing is referenced from the input signal crossing at the VIH(ac) level for a rising signal and VIL(ac) for a falling signal applied to the device under test. 23. Input waveform timing is referenced from the input signal crossing at the VIL(dc) level for a rising signal and VIH(dc) for a falling signal applied to the device under test. 24. tWTR is at least two clocks (2 x tCK or 2 x nCK) independent of operation frequency. 25. Input waveform timing with single-ended data strobe enabled MR[bit10] = 1, is referenced from the input signal crossing at the VIH (ac) level to the single-ended data strobe crossing VIH/L (dc) at the start of its transition for a rising signal, and from the input signal crossing at the VIL (ac) level to the singleended data strobe crossing VIH/L (dc) at the start of its transition for a falling signal applied to the device under test. The DQS signal must be monotonic between Vil(dc)max and Vih (dc) min. 26. Input waveform timing with single-ended data strobe enabled MR[bit10] = 1, is referenced from the input signal crossing at the VIH(dc) level to the single-ended data strobe crossing VIH/L(ac) at the end of its transition for a rising signal, and from the input signal crossing at the VIL(dc) level to the single-ended data strobe crossing VIH/L(ac) at the end of its transition for a falling signal applied to the device under test. The DQS signal must be monotonic between Vil(dc)max and Vih (dc) min. 27. tCKEmin of 3 clocks means CKE must be registered on three consecutive positive clock edges. CKE must remain at the valid input level the entire time it takes to achieve the 3 clocks of registration. Thus, after any CKE transition, CKE may not transition from its valid level during the time period of tIS + 2 x tCK + tIH. 28. If tDS or tDH is violated, data corruption may occur and the data must be re-written with valid data before a valid READ can be executed. 29. These parameters are measured from a command/address signal (CKE, CS, RAS, CAS, WE, ODT, BA0, A0, A1, etc.) transition edge to its respective clock signal (CK/CK) crossing. The spec values are not affected by the amount of clock jitter applied (i.e. tJIT (per), tJIT (cc), etc.), as the setup and hold are relative to the clock signal crossing that latches the command/address. That is, these parameters should be met whether clock jitter is present or not. 30. These parameters are measured from a data strobe signal ((L/U/R)DQS/DQS) crossing to its respective clock signal (CK/CK) crossing. The spec values are not affected by the amount of clock jitter applied (i.e. tJIT (per), tJIT (cc), etc.), as these are relative to the clock signal crossing. That is, these parameters should be met whether clock jitter is present or not. 31. These parameters are measured from a data signal ((L/U) DM, (L/U) DQ0, (L/U) DQ1, etc.) transition edge to its respective data strobe signal ((L/U/R)DQS/DQS) crossing. 32. For these parameters, the DDR2 SDRAM device is characterized and verified to support tnPARAM = RU {tPARAM / tCK (avg)}, which is in clock cycles, assuming all input clock jitter specifications
Rev. 1.0 / Aug 2009
39
Release H5PS1G83EFR Series
are satisfied. For example, the device will support tnRP = RU {tRP / tCK (avg)}, which is in clock cycles, if all input clock jitter specifications are met. This means: For DDR2-667 5-5-5, of which tRP = 15ns, the device will support tnRP =RU {tRP / tCK (avg)} = 5, i.e. as long as the input clock jitter specifications are met, Precharge command at Tm and Active command at Tm+5 is valid even if (Tm+5 - Tm) is less than 15ns due to input clock jitter. 33. tDAL [nCK] = WR [nCK] + tnRP [nCK] = WR + RU {tRP [ps] / tCK (avg) [ps]}, where WR is the value programmed in the mode register set. 34. New units, ‘tCK (avg)’ and ‘nCK’, are introduced in DDR2-667 and DDR2-800. Unit ‘tCK (avg)’ represents the actual tCK (avg) of the input clock under operation. Unit ‘nCK’, represents one clock cycle of the input clock, counting the actual clock edges. Note that in DDR2-400 and DDR2-533, ‘tCK’, is used for both concepts. ex) tXP = 2 [nCK] means; if Power Down exit is registered at Tm, an Active command may be registered at Tm+2, even if (Tm+2 - Tm) is 2 x tCK (avg) + tERR(2per),min. 35. Input clock jitter spec parameter. These parameters and the ones in the table below are referred to as 'input clock jitter spec parameters' and these parameters apply to DDR2-667 and DDR2-800 only. The jitter specified is a random jitter meeting a Gaussian distribution.
DDR2-667 Parameter
Clock period jitter Clock period jitter during DLL locking period Cycle to cycle clock period jitter Cycle to cycle clock period jitter during DLL locking period Cumulative error across 2 cycles Cumulative error across 3 cycles Cumulative error across 4 cycles Cumulative error across 5 cycles Cumulative error across n cycles, n=6...10, inclusive Cumulative error across n cycles, n=11...50, inclusive Duty cycle jitter
DDR2-800 Units Notes
35 35 35 35 35 35 35 35 35 35 35
Symbol min
tJIT (per) tJIT (per, lck) tJIT (cc) tJIT (cc, lck) tERR(2per) tERR(3per) tERR(4per) tERR(5per) tERR(6~10per) tERR(11~50per) tJIT (duty) -125 -100 -250 -200 -175 -225 -250 -250 -350 -450 -125
max
125 100 250 200 175 225 250 250 350 450 125
min
-100 -80 -200 -160 -150 -175 -200 -200 -300 -450 -100
max
100 80 200 160 150 175 200 200 300 450 100 ps ps ps ps ps ps ps ps ps ps ps
Rev. 1.0 / Aug 2009
40
Release H5PS1G83EFR Series
36. These parameters are specified per their average values, however it is understood that the following relationship between the average timing and the absolute instantaneous timing holds at all times. (Min and max of SPEC values are to be used for calculations in the table below.)
Parameter
Absolute clock period Absolute clock HIGH pulse width Absolute clock LOW pulse width
Symbol
tCK (abs) tCH (abs) tCL (abs)
min
tCK (avg), min + tJIT (per), min
max
tCK (avg), max + tJIT (per), max
Units
ps ps ps
tCH (avg), min * tCK (avg), min + tCH (avg), max * tCK (avg), max tJIT (per), min + tJIT (per), max tCL (avg), min * tCK (avg), min + tJIT (per), min tCL (avg), max * tCK (avg), max + tJIT (per), max
Example: For DDR2-667, tCH (abs), min = (0.48 x 3000 ps) - 125 ps = 1315 ps 37. tHP is the minimum of the absolute half period of the actual input clock. tHP is an input parameter but not an input specification parameter. It is used in conjunction with tQHS to derive the DRAM output timing tQH. The value to be used for tQH calculation is determined by the following equation; tHP = Min (tCH (abs), tCL (abs)), where, tCH (abs) is the minimum of the actual instantaneous clock HIGH time; tCL (abs) is the minimum of the actual instantaneous clock LOW time; 38. tQHS accounts for: 1) The pulse duration distortion of on-chip clock circuits, which represents how well the actual tHP at the input is transferred to the output; and 2) The worst case push-out of DQS on one transition followed by the worst case pull-in of DQ on the next transition, both of which are independent of each other, due to data pin skew, output pattern effects, and p-channel to n-channel variation of the output drivers 39. tQH = tHP ? tQHS, where: tHP is the minimum of the absolute half period of the actual input clock; and tQHS is the specification value under the max column. {The less half-pulse width distortion present, the larger the tQH value is; and the larger the valid data eye will be.} Examples: 1) If the system provides tHP of 1315 ps into a DDR2-667 SDRAM, the DRAM provides tQH of 975 ps minimum. 2) If the system provides tHP of 1420 ps into a DDR2-667 SDRAM, the DRAM provides tQH of 1080 ps minimum. 40. When the device is operated with input clock jitter, this parameter needs to be derated by the actual tERR(6-10per) of the input clock. (output deratings are relative to the SDRAM input clock.) For example, if the measured jitter into a DDR2-667 SDRAM has tERR(6-10per),min = - 272 ps and tERR(6-10per), max = + 293 ps, then tDQSCK, min (derated) = tDQSCK, min - tERR(6-10per),max = 400 ps - 293 ps = - 693 ps and tDQSCK, max (derated) = tDQSCK, max - tERR(6-10per),min = 400 ps +
Rev. 1.0 / Aug 2009
41
Release H5PS1G83EFR Series
272 ps = + 672 ps. Similarly, tLZ (DQ) for DDR2-667 derates to tLZ (DQ), min (derated) = - 900 ps - 293 ps = - 1193 ps and tLZ (DQ), max (derated) = 450 ps + 272 ps = + 722 ps. (Caution on the min/max usage!) 41. When the device is operated with input clock jitter, this parameter needs to be derated by the actual tJIT (per) of the input clock. (output deratings are relative to the SDRAM input clock.) For example, if the measured jitter into a DDR2-667 SDRAM has tJIT (per), min = - 72 ps and tJIT (per), max = + 93 ps, then tRPRE, min (derated) = tRPRE, min + tJIT (per), min = 0.9 x tCK (avg) - 72 ps = + 2178 ps and tRPRE, max (derated) = tRPRE, max + tJIT (per), max = 1.1 x tCK (avg) + 93 ps = + 2843 ps. (Caution on the min/max usage!) 42. When the device is operated with input clock jitter, this parameter needs to be derated by the actual tJIT (duty) of the input clock. (output deratings are relative to the SDRAM input clock.) For example, if the measured jitter into a DDR2-667 SDRAM has tJIT (duty), min = - 72 ps and tJIT (duty), max = + 93 ps, then tRPST, min (derated) = tRPST, min + tJIT (duty), min = 0.4 x tCK (avg) - 72 ps = + 928 ps and tRPST, max (derated) = tRPST, max + tJIT (duty), max = 0.6 x tCK (avg) + 93 ps = + 1592 ps. (Caution on the min/max usage!) 43. When the device is operated with input clock jitter, this parameter needs to be derated by {tJIT (duty), max - tERR(6-10per),max} and {- tJIT (duty), min - tERR(6-10per),min} of the actual input clock.(output deratings are relative to the SDRAM input clock.) For example, if the measured jitter into a DDR2-667 SDRAM has tERR(6-10per),min = - 272 ps, tERR(610per), max = + 293 ps, tJIT (duty), min = - 106 ps and tJIT (duty), max = + 94 ps, then tAOF, min (derated) = tAOF, min + {- tJIT (duty), max - tERR(6-10per),max} = - 450 ps + {- 94 ps - 293 ps} = - 837 ps and tAOF, max (derated) = tAOF, max + {- tJIT (duty), min - tERR(6-10per),min} = 1050 ps + {106 ps + 272 ps} = + 1428 ps. (Caution on the min/max usage!) 44. For tAOFD of DDR2-400/533, the 1/2 clock of tCK in the 2.5 x tCK assumes a tCH, input clock HIGH pulse width of 0.5 relative to tCK. tAOF, min and tAOF, max should each be derated by the same amount as the actual amount of tCH offset present at the DRAM input with respect to 0.5. For example, if an input clock has a worst case tCH of 0.45, the tAOF, min should be derated by subtracting 0.05 x tCK from it, whereas if an input clock has a worst case tCH of 0.55, the tAOF, max should be derated by adding 0.05 x tCK to it. Therefore, we have; tAOF, min (derated) = tAC, min - [0.5 - Min(0.5, tCH, min)] x tCK tAOF, max (derated) = tAC, max + 0.6 + [Max(0.5, tCH, max) - 0.5] x tCK or tAOF, min (derated) = Min (tAC, min, tAC, min - [0.5 - tCH, min] x tCK) tAOF, max (derated) = 0.6 + Max (tAC, max, tAC, max + [tCH, max - 0.5] x tCK) where tCH, min and tCH, max are the minimum and maximum of tCH actually measured at the DRAM input balls. 45. For tAOFD of DDR2-667/800, the 1/2 clock of nCK in the 2.5 x nCK assumes a tCH (avg), average input clock HIGH pulse width of 0.5 relative to tCK (avg). tAOF, min and tAOF, max should each be derated by the same amount as the actual amount of tCH (avg) offset present at the DRAM input with respect to 0.5. For example, if an input clock has a worst case tCH (avg) of 0.48, the tAOF, min should be derated by subRev. 1.0 / Aug 2009
42
Release H5PS1G83EFR Series
tracting 0.02 x tCK (avg) from it, whereas if an input clock has a worst case tCH (avg) of 0.52, the tAOF, max should be derated by adding 0.02 x tCK (avg) to it. Therefore, we have; tAOF, min (derated) = tAC, min - [0.5 - Min(0.5, tCH (avg), min)] x tCK (avg) tAOF, max (derated) = tAC, max + 0.6 + [Max(0.5, tCH (avg), max) - 0.5] x tCK (avg) or tAOF, min (derated) = Min (tAC, min, tAC, min - [0.5 - tCH (avg), min] x tCK (avg)) tAOF, max (derated) = 0.6 + Max (tAC, max, tAC, max + [tCH (avg), max - 0.5] x tCK (avg)) where tCH (avg), min and tCH (avg), max are the minimum and maximum of tCH (avg) actually measured at the DRAM input balls. Note that these deratings are in addition to the tAOF derating per input clock jitter, i.e. tJIT (duty) and tERR(6-10per). However tAC values used in the equations shown above are from the timing parameter table and are not derated. Thus the final derated values for tAOF are; tAOF, min (derated _ final) = tAOF, min (derated) + {- tJIT (duty), max - tERR(6-10per),max} tAOF, max (derated _ final) = tAOF, max (derated) + {- tJIT (duty), min - tERR(6-10per),min}
Rev. 1.0 / Aug 2009
43
H5PS1G83EFR Series
1Gb DDR2 SDRAM
DDR2-1066 [TBD]
This document is a general product description and is subject to change without notice. Hynix Semiconductor does not assume any responsibility for use of circuits described. No patent licenses are implied. Rev. 1.0 / Aug 2009 44
Release H5PS1G83EFR Series
For purposes of IDD testing, the following parameters are to be utilized
Speed Bin (CL-tRCD-tRP) CL(IDD) tRCD(IDD) tRC(IDD) tRRD(IDD)-x8 tFAW-x8 tCK(IDD) tRASmin(IDD) tRASmax(IDD) tRP(IDD) tRFC(IDD)-256Mb tRFC(IDD)-512Mb tRFC(IDD)-1Gb DDR2-1066 Units 7-7-7 7 13.125 58.125 7.5 35 1.875 45 70000 13.125 75 105 127.5 tCK ns ns ns ns ns ns ns ns ns ns ns
Detailed IDD7 The detailed timings are shown below for IDD7. Changes will be required if timing parameter changes are made to the specification. Legend: A = Active; RA = Read with Autoprecharge; D = Deselect IDD7: Operating Current: All Bank Interleave Read operation All banks are being interleaved at minimum tRC(IDD) without violating tRRD(IDD) using a burst length of 4. Control and address bus inputs are STABLE during DESELECTs. IOUT = 0mA
Timing Patterns for 8 bank devices x8 (1KB Page size)
-DDR2-1066 all bins: A0 RA0 D D A1 RA1 D D A2 RA2 D D A3 RA3 D D D D D A4 RA4 D D A5 RA5 D D A6 RA6 D D A7 RA7 D D D D D
Rev. 1.0 / Aug 2009
45
Release H5PS1G83EFR Series 3.5. Input/Output Capacitance
Parameter Input capacitance, CK and CK Input capacitance delta, CK and CK Input capacitance, all other input-only pins Input capacitance delta, all other input-only pins Input/output capacitance, DQ, DM, DQS, DQS Input/output capacitance delta, DQ, DM, DQS, DQS Symbol CCK CDCK CI CDI CIO CDIO DDR2- 1066 Min 1.0 x 1.0 x 2.5 x Max 2.0 0.25 1.75 0.25 3.5 0.5 Units pF pF pF pF pF pF
4. Electrical Characteristics & AC Timing Specification
( 0 ℃ ≤ TCASE ≤ 95℃; VDDQ = 1.8 V +/- 0.1V; VDD = 1.8V +/- 0.1V)
Refresh Parameters by Device Density
Parameter Refresh to Active /Refresh command time Average periodic refresh interval tREFI Symbol tRFC 0 ℃ ≤ TCASE ≤ 85℃ 85℃ < TCASE ≤ 95℃ 256Mb 512Mb 75 7.8 3.9 105 7.8 3.9 1Gb 127.5 7.8 3.9 2Gb 195 7.8 3.9 4Gb 327.5 7.8 3.9 Units ns us us
DDR2 SDRAM speed bins and tRCD, tRP and tRC for corresponding bin
Speed Bin(CL-tRCD-tRP) Parameter CAS Latency tRCD : ACT to RD(A) or WT(A) Delay tRP : PRE to ACT Delay tRAS : ACT to PRE Delay tRC : ACT to ACT Delay tCK(avg) @ CL=7 DDR2-1066 7-7-7 min 7 13.125 13.125 45 min / 70000 max 58.125 1.875 min / 7.5 max tCK ns ns ns ns ns Units
Rev. 1.0 / Aug 2009
46
Release H5PS1G83EFR Series Timing Parameters by Speed Grade
(Refer to notes for information related to this table at the following pages of this table)
Parameter DQ output access time from CK/CK DQS output access time from CK/CK CK high-level width CK low-level width CK half period Clock cycle time, CL=x DQ and DM input setup time (differential strobe) DQ and DM input hold time (differential strobe) Control & Address input pulse width for each input DQ and DM input pulse width for each input Data-out high-impedance time from CK/CK DQS low-impedance time from CK/CK DQ low-impedance time from CK/CK DQS-DQ skew for DQS and associated DQ signals DQ hold skew factor DQ/DQS output hold time from DQS First DQS latching transition to associated clock edge DQS input high pulse width DQS input low pulse width DQS falling edge to CK setup time DQS falling edge hold time from CK Mode register set command cycle time Write postamble Write preamble Address and control input setup time Address and control input hold time Symbol tAC tDQSCK tCH tCL tHP tCK tDS (base) tDH (base) tIPW tDIPW tHZ tLZ(DQS) tLZ(DQ) tDQSQ tQHS tQH tDQSS tDQSH tDQSL tDSS tDSH tMRD tWPST tWPRE tIS(base) tIH(base) DDR2-1066 min -350 -325 0.48 0.48 min (tCL,tCH) 1875 0 max +350 +325 0.52 0.52 7500 Unit ps ps tCK tCK ps ps ps Note 35 35 30, 31 30, 31 32 30, 31 6,7,8, 17, 23, 26 6,7,8, 16, 23, 26
75 0.6 0.35 tAC min 2*tAC min tHP - tQHS -0.25 0.35 0.35 0.2 0.2 2 0.4 0.35 125 200
tAC max tAC max tAC max 175 250 + 0.25 0.6 -
ps tCK(avg) tCK(avg) ps ps ps ps ps ps tCK(avg) tCK(avg) tCK(avg) tCK(avg) tCK(avg) tCK tCK(avg) tCK(avg) ps ps
15, 35 15, 35 15, 35 11 33 34 25
25 25 10 5,7,9, 19, 24 5,7,9, 20, 24
Rev. 1.0 / Aug 2009
47
Release H5PS1G83EFR Series
-Continue(Refer to notes for information related to this table at the following pages of this table)
Parameter Read preamble Read postamble Active to active command period for 2KB page size products Four Active Window for 2KB page size products CAS to CAS command delay Write recovery time Auto precharge write recovery + precharge time Internal write to read command delay Internal read to precharge command delay Exit self refresh to a non-read command Exit self refresh to a read command Exit active power down to read command Exit active power down to read command (Slow exit, Lower power) CKE minimum pulse width (high and low pulse width) ODT turn-on delay ODT turn-on ODT turn-on(Power-Down mode) ODT turn-off delay ODT turn-off ODT turn-off (Power-Down mode) ODT to power down entry latency ODT power down exit latency OCD drive mode output delay Minimum time clocks remains ON after CKE asynchronously drops LOW Symbol tRPRE tRPST tRRD tFAW tCCD tWR tDAL tWTR tRTP tXSNR tXSRD tXARD tXARDS
tCKE tAOND tAON tAONPD tAOFD tAOF tAOFPD
DDR2-1066 min 0.9 0.4 7.5 35 2 15 WR+tRP 7.5 7.5 tRFC + 10 200 3 3 10 - AL 3 2 tAC(min) tAC(min)+2 2.5 tAC(min) tAC(min)+2 4 11 0 tIS+tCK(avg) +tIH 2 tAC(max) +2.575 3tCK+ tAC(max)+1 2.5 tAC(max)+ 0.6 2.5tCK avg+ tAC(max)+1 max 1.1 0.6 -
Unit tCK(avg) tCK(avg) ns ns tCK ns tCK ns ns ns tCK tCK tCK tCK tCK tCK ns ns tCK ns ns tCK tCK ns ns
Note 16, 36 16, 37 4, 27 27 27 28 21, 27 3, 27 27
Exit precharge power down to any non-read command tXP
1 1, 2 22 13 6, 13, 35
14, 39 14, 38, 39
tANPD tAXPD tOIT tDelay
12
27 12
Rev. 1.0 / Aug 2009
48
Release H5PS1G83EFR Series
General notes, which may apply for all AC parameters
1. Slew Rate Measurement Levels a. Output slew rate for falling and rising edges is measured between VTT - 250 mV and VTT + 250 mV for single ended signals. For differential signals (e.g. DQS - DQS) output slew rate is measured between DQS - DQS = -500 mV and DQS - DQS = +500mV. Output slew rate is guaranteed by design, but is not necessarily tested on each device. b. Input slew rate for single ended signals is measured from dc-level to ac-level: from VIL(dc) to VIH(ac) for rising edges and from VIH(dc) and VIL(ac) for falling edges. For differential signals (e.g. CK - CK) slew rate for rising edges is measured from CK - CK = -250 mV to CK - CK = +500 mV(250mV to -500 mV for falling egdes). c. VID is the magnitude of the difference between the input voltage on CK and the input voltage on CK, or between DQS and DQS for differential strobe. 2. DDR2 SDRAM AC timing reference load The following figure represents the timing reference load used in defining the relevant timing parameters of the part. It is not intended to be either a precise representation of the typical system environment nor a depiction of the actual load presented by a production tester. System designers will use IBIS or other simulation tools to correlate the timing reference load to a system environment. Manufacturers will correlate to their production test conditions (generally a coaxial transmission line terminated at the tester electronics).
VDDQ
DQ DQS DQS RDQS RDQS
DUT
Output Timing reference point 25Ω
VTT = VDDQ/2
AC Timing Reference Load
The output timing reference voltage level for single ended signals is the crosspoint with VTT. The output timing reference voltage level for differential signals is the crosspoint of the true (e.g. DQS) and the complement (e.g. DQS) signal. 3. DDR2 SDRAM output slew rate test load Output slew rate is characterized under the test conditions as shown below.
VDDQ DUT
DQ DQS, DQS RDQS, RDQS
Output Test point 25Ω
VTT = VDDQ/2
Slew Rate Test Load
4. Differential data strobe DDR2 SDRAM pin timings are specified for either single ended mode or differential mode depending on the setting of the EMRS “Enable DQS” mode bit; timing advantages of differential mode are realized in system design. The method by which the DDR2 SDRAM pin timings are measured is mode dependent. In single
Rev. 1.0 / Aug 2009
49
Release H5PS1G83EFR Series
VREF. In differential mode, these timing relationships are measured relative to the crosspoint of DQS and its complement, DQS. This distinction in timing methods is guaranteed by design and characterization. Note that when differential data strobe mode is disabled via the EMRS, the complementary pin, DQS, must be tied externally to VSS through a 20 ohm to 10 K ohm resistor to insure proper operation.
DQS
tDQSH
tDQSL
DQS/ DQS
DQS tWPRE VIH(ac) VIH(dc) D VIL(ac) tDS tDS VIH(ac) DMin VIL(ac) tDH DMin D D VIL(dc) tDH DMin VIL(dc) VIH(dc) D tWPST
DQ
DM
DMin
Figure -- Data input (write) timing
tCH CK
tCL
CK/CK
CK
DQS
DQS/DQS
DQS tRPRE tRPST Q tDQSQmax tQH Q Q tDQSQmax tQH Q
DQ
Figure -- Data output (read) timing 5. AC timings are for linear signal transitions. See System Derating for other signal transitions. 6. All voltages referenced to VSS. 7. These parameters guarantee device behavior, but they are not necessarily tested on each device. They may be guaranteed by device design or tester correlation. 8. Tests for AC timing, IDD, and electrical (AC and DC) characteristics, may be conducted at nominal reference/ supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified.
Rev. 1.0 / Aug 2009
50
Release H5PS1G83EFR Series Specific Notes for dedicated AC parameters
1. User can choose which active power down exit timing to use via MRS(bit 12). tXARD is expected to be used for fast active power down exit timing. tXARDS is expected to be used for slow active power down exit timing where a lower power value is defined by each vendor data sheet. 2. AL = Additive Latency 3. This is a minimum requirement. Minimum read to precharge timing is AL + BL/2 providing the tRTP and tRAS(min) have been satisfied. 4. A minimum of two clocks (2 * tCK) is required irrespective of operating frequency 5. Timings are guaranteed with command/address input slew rate of 1.0 V/ns. See System Derating for other slew rate values. 6. Timings are guaranteed with data, mask, and (DQS/RDQS in singled ended mode) input slew rate of 1.0 V/ns. See System Derating for other slew rate values. 7. Timings are guaranteed with CK/CK differential slew rate of 2.0 V/ns. Timings are guaranteed for DQS signals with a differen tial slew rate of 2.0 V/ns in differential strobe mode and a slew rate of 1V/ns in single ended mode. See System Derating for other slew rate values.
tDS, tDH Derating Values for DDR2-1066(ALL units in 'ps', Note 1 applies to entire Table) DQS, DQS Differential Slew Rate 4.0 V/ns
△ tDS 100 67 0 △ tDH 45 21 0 -
3.0 V/ns
△ tDS 100 67 0 -5 △ tDH 45 21 0 -14 -
2.0 V/ns
△ tDS 100 67 0 -5 -13 △ tDH 45 21 0 -14 -31 -
1.8 V/ns
△ tDS 79 12 7 -1 -10 △ tDH 33 12 -2 -19 -42 -
1.6 V/ns
△ tDS 24 19 11 2 -10 △ tDH 24 10 -7 -30 -59 -
1.4 V/ns
△ tDS 31 23 14 2 -24 △ tDH 22 5 -18 -47 -89 -
1.2 V/ns
△ tDS 35 26 14 -12 -52 △ tDH 17 -6 -35 -77 -140
1.0 V/ns
△ tDS 38 26 0 -40 △ tDH 6 -23 -65 -128
0.8 V/ns
△ tDS 38 12 -28 △ tDH -11 -53 -116
2.0 1.5 DQ Slew rate V/ns 1.0 0.9 0.8 0.7 0.6 0.5 0.4
1) For all input signals the total tIS(setup time) and tIH(hold) time) required is calculated by adding the datasheet value to the derating value listed in above Table. Setup(tIS) nominal slew rate for a rising signal is defined as the slew rate between the last crossing of VREF(dc) and the first crossing of VIH(ac)min. Setup(tIS) nominal slew rate for a falling signal is defined as the slew rate between the last crossing of VREF(dc) and the first crossing of VIL(ac)max. If the actual signal is always earlier than the nominal slew rate for line between shaded ‘VREF(dc) to ac region’, use nominal slew rate for derating value(see fig a.) If the actual signal is later than the nominal slew rate line anywhere between shaded ‘VREF(dc) to ac region’, the slew rate of a tangent line to the actual signal from the ac level to dc level is used for derating value(see Fig b.) Hold(tIH) nominal slew rate for a rising signal is defined as the slew rate between the last crossing of VIL(dc)max and the first crossing of VREF(dc). Hold(tIH) nominal slew rate for a falling signal is defined as the slew rate between the last crossing of VREF(dc). If the actual signal is always later than the nominal slew rate line between shaded ‘dc to VREF(dc) region’, use nominal slew rate for derating value(see Fig.c)
Rev. 1.0 / Aug 2009
51
Release H5PS1G83EFR Series
If the actual signal is earlier than the nominal slew rate line anywhere between shaded ‘dc to VREF(dc) region’, the slew rate of a tangent line to the actual signal from the dc level to VREF(dc) level is used for derating value(see Fig d.) Although for slow rates the total setup time might be negative(i.e. a valid input signal will not have reached VIH/IL(ac) at the time of the rising clock transition) a valid input signal is still required to complete the transition and reach VIH/IL(ac). For slew rates in between the values listed in table, the derating values may obtained by linear interpolation. These values are typically not subject to production test. They are verified by design and characterization.
Rev. 1.0 / Aug 2009
52
Release H5PS1G83EFR Series
Fig. a Illustration of nominal slew rate for tIS,tDS
CK,DQS CK, DQS tIS, tDS VDDQ tIH, tDH tIS, tDS tIH, tDH
VIH(ac)min
VIH(dc)min
nominal slew rate
VREF(dc) nominal slew rate VREF to ac region
VIL(dc)max
VIL(ac)max Vss
Delta TF Setup Slew Rate = Falling Signal VREF(dc)-VIL(ac)max Delta TF
Delta TR Setup Slew Rate = Rising Signal VIH(ac)min-VREF(dc) Delta TR
Rev. 1.0 / Aug 2009
53
Release H5PS1G83EFR Series
Fig. -b Illustration of tangent line for tIS,tDS
CK, DQS CK, DQS tIS, tDS VDDQ nominal line VIH(ac)min tIH, tDH tIS, tDS tIH, tDH
VIH(dc)min tangent line VREF(dc) Tangent line VIL(dc)max VREF to ac region VIL(ac)max Nomial line Vss Delta TF
Delta TR Setup Slew Rate Tangent line[VIH(ac)min-VREF(dc)] = Rising Signal Delta TR
Setup Slew Rate Tangent line[VREF(dc)-VIL(ac)max] = Falling Signal Delta TF
Rev. 1.0 / Aug 2009
54
Release H5PS1G83EFR Series
Fig. -c Illustration of nominal line for tIH, tDH
CK, DQS CK, DQS tIS, tDS VDDQ tIH, tDH tIS, tDS tIH, tDH
VIH(ac)min
VIH(dc)min dc to VREF region VREF(dc) nominal slew rate nominal slew rate
VIL(dc)max
VIL(ac)max
Vss Delta TR Hold Slew Rate = Rising Signal VREF(dc)-VIL(dc)max Delta TR Delta TF
VIH(dc)min - VREF(dc) Hold Slew Rate = Falling Signal Delta TF
Rev. 1.0 / Aug 2009
55
Release H5PS1G83EFR Series
Fig. -d Illustration of tangent line for tIH , tDH
CK, DQS CK, DQS
tIS, tDS
VDDQ
tIH, tDH
tIS, tDS
tIH, tDH
VIH(ac)min nominal line VIH(dc)min tangent line VREF(dc) dc to VREF region VIL(dc)max Tangent line nominal line
VIL(ac)max
Vss Delta TR Hold Slew Rate Tangent line[VREF(dc)-VIL(ac)max] = Rising Signal Delta TR Tangent line[VIH(ac)min-VREF(dc)] Hold Slew Rate = Falling Signal Delta TF Delta TF
Rev. 1.0 / Aug 2009
56
Release H5PS1G83EFR Series
10. The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this parameter, but system performance (bus turnaround) will degrade accordingly. 11. tDQSQ: Consists of data pin skew and output pattern effects, and p-channel to n-channel variation of the output
drivers as well as output slew rate mismatch between DQS / DQS and associated DQ in any given cycle. 12. The clock frequency is allowed to change during self–refresh mode or precharge power-down mode. In case of clock frequency change during precharge power-down, a specific procedure is required as described in section Input clock frequency change during precharge power down. 13. ODT turn on time min is when the device leaves high impedance and ODT resistance begins to turn on. ODT turn on time max is when the ODT resistance is fully on. Both are measured from tAOND, which is interpreted as 2 clock cycles after the clock edge that registered a first ODT HIGH counting the actual input clock edges. 14. ODT turn off time min is when the device starts to turn off ODT resistance. ODT turn off time max is when the bus is in high impedance. Both are measured from tAOFD, which is interpreted as 0.5 x tCK(avg) [ns] after the second trailing clock edge counting from the clock edge that registered a first ODT LOW and by counting the actual input clock edges. For DDR2-1066, this is 0.9375 [ns] (= 0.5 x 1.875 [ns]) after the second trailing clock edge counting from the clock edge that registered a first ODT LOW and by counting the actual input clock edges.
15. tHZ and tLZ transitions occur in the same access time as valid data transitions. Thesed parameters are referenced to a specific voltage level which specifies when the device output is no longer driving(tHZ), or begins driving (tLZ). Below figure shows a method to calculate the point when device is no longer driving (tHZ), or begins driving (tLZ) by measuring the signal at two different voltages. The actual voltage measurement points are not critical as long as the calculation is consistenet. 16. tRPST end point and tRPRE begin point are not referenced to a specific voltage level but specify when the device output is no longer driving (tRPST), or begins driving (tRPRE). Below figure shows a method to calculate these points when the device is no longer driving (tRPST), or begins driving (tRPRE). Below Figure shows a method to calculate these points when the device is no longer driving (tRPST), or begins driving (tRPRE) by measuring the signal at two different voltages. The actual voltage measurement points are not critical as long as the calculation is consistent.
VOH + xmV VOH + 2xmV tHZ tRPST end point T2 T1 VOL + 1xmV VOL + 2xmV
VTT + 2xmV VTT + xmV tLZ tRPRE begin point T1 VTT -xmV VTT - 2xmV T2
tHZ , tRPST end point = 2*T1-T2
tLZ , tRPRE begin point = 2*T1-T2
Rev. 1.0 / Aug 2009
57
Release H5PS1G83EFR Series
17. Input waveform timing tDS with differential data strobe enabled MR[bit10]=0, is referenced from the input signal
crossing at the VIH(ac) level to the differential data strobe crosspoint for a rising signal, and from the input signal crossing at the VIL(ac) level to the differential data strobe crosspoint for a falling signal applied to the device under test. DQS, DQS signals must be monotonic between Vil(dc)max and Vih(dc)min. 18. Input waveform timing tDH with differential data strobe enabled MR[bit10]=0, is referenced from the differential data strobe crosspoint to the input signal crossing at the VIH(dc) level for a falling signal and from the differential data strobe crosspoint to the input signal crossing at the VIL(dc) level for a rising signal applied to the device under test. DQS, DQS signals must be monotonic between Vil(dc)max and Vih(dc)min.
Differential Input waveform timing
DQS
DQS tDS tDH tDS tDH
VDDQ VIH(ac)min VIH(dc)min VREF(dc) VIL(dc)max VIL(ac)max VSS
19. Input waveform timing is referenced from the input signal crossing at the VIH(ac) level for a rising signal and VIL(ac) for a falling signal applied to the device under test. 20. Input waveform timing is referenced from the input signal crossing at the VIL(dc) level for a rising signal and VIH(dc) for a falling signal applied to the device under test. 21. tWTR is at lease two clocks (2 x nCK) independent of operation frequency. 22. tCKEmin of 3 clocks means CKE must be registered on three consecutive positive clock edges. CKE must remain at the valid input level the entire time it takes to achieve the 3 clocks of registration. Thus, after any CKE transition, CKE may not transition from its valid level during the time period of tIS + 2* tCK + tIH. 23. If tDS or tDH is violated, data corruption may occur and the data must be re-written with valid data before a valid READ can be executed.
Rev. 1.0 / Aug 2009
58
Release H5PS1G83EFR Series
24. These parameters are measured from a command/address signal (CKE, CS, RAS, CAS, WE, ODT, BA0, A0, A1, etc.) transition edge to its respective clock signal (CK/CK) crossing. The spec values are not affected by the amount of clock jitter applied (i.e. tJIT(per), tJIT(cc), etc.), as the setup and hold are relative to the clock signal crossing that latches the command/address. That is, these parameters should be met whether clock jitter is present or not. 25. These parameters are measured from a data strobe signal ((L/U/R)DQS/DQS) crossing to its respective clock signal (CK/CK) crossing. The spec values are not affected by the amount of clock jitter applied (i.e. tJIT(per), tJIT(cc), etc.), as these are relative to the clock signal crossing. That is, these parameters should be met whether clock jitter is present or not. 26. These parameters are measured from a data signal ((L/U) DM, (L/U) DQ0, (L/U) DQ1, etc.) transition
edge to its respective data strobe signal ((L/U/R)DQS/DQS) crossing. 27. For these parameters, the DDR2 SDRAM device is characterized and verified to support tnPARAM = RU{tPARAM / tCK(avg)}, which is in clock cycles, assuming all input clock jitter specifications are satisfied. For example, the device will support tnRP = RU {tRP / tCK(avg)}, which is in clock cycles, if all input clock jitterspecifications are met. This means: For DDR2-1066 7-7-7, of which tRP = 13.125ns, the device will support tnRP =RU{tRP / tCK(avg)} = 7, i.e. as long as the input clock jitter specifications are met, Precharge command at Tm and Active command at Tm+7 is valid even if (Tm+7 - Tm) is less than 13.127ns due to input clock jitter.
28. Specific Note 28 tDAL [nCK] = WR [nCK] + tnRP [nCK] = WR + RU {tRP [ps] / tCK(avg) [ps] }, where WR is the value programmed in the mode register set and RU stands for round up. Example: For DDR2-1066 7-7-7 at tCK(avg) = 1.875 ns with WR programmed to 8 nCK, tDAL = 8 + RU {13.125 ns / 1.875 ns} [nCK] = 8 + 7 [nCK] = 15 [nCK] 29.New units, ‘tCK(avg)’ and ‘nCK’, are introduced in DDR2-1066. Unit ‘tCK(avg)’ represents the actual tCK(avg) of the input clock under operation. Unit ‘nCK’ represents one clock cycle of the input clock, counting the actual clock edges. ex) tXP = 3 [nCK] means; if Power Down exit is registered at Tm, an Active command may be registered at Tm+3, even if (Tm+3 - Tm) is 3 x tCK(avg) + tERR(3per),min. 30. Input clock jitter spec parameter. These parameters and the ones in the table below are referred to as
'input clock jitter spec parameters' and these parameters apply to DDR2-1066. The jitter specified is a random jitter meeting a Gaussian distribution.
Rev. 1.0 / Aug 2009
59
Release H5PS1G83EFR Series
Parameter Clock period jitter Clock period jitter during DLL locking period Cycle to cycle clock period jitter
Symbol tJIT(per) tJIT(per,lck) tJIT(cc)
DDR2-1066 min -90 -80 -180 -160 -132 -157 -175 -188 -250 -425 -75 max 90 80 180 160 132 157 175 188 250 425 75
Units ps ps ps ps ps ps ps ps ps ps ps
Notes 30 30 30 30 30 30 30 30 30 30 30
Cycle to cycle clock period jitter during DLL locktJIT(cc,lck) ing period Cumulative error across 2 cycles Cumulative error across 3 cycles Cumulative error across 4 cycles Cumulative error across 5 cycles Cumulative error across n cycles, n=6...10, inclusive Cumulative error across n cycles, n=11...50, inclusive Duty cycle jitter tERR(2per) tERR(3per) tERR(4per) tERR(5per) tERR(6~10per) tERR(11~50per) tJIT(duty)
31. These parameters are specified per their average values, however it is understood that the following relationship between the average timing and the absolute instantaneous timing holds at all times. (Min and max of SPEC values are to be used for calculations in the table below.
Parameter
Absolute clock period Absolute clock HIGH pulse width Absolute clock LOW pulse width
Symbol
tCK(abs) tCH(abs) tCL(abs)
min
tCK(avg),min+tJIT(per),min
tCH(avg),min x tCK(avg),min + tJIT(duty),min tCL(avg),min x tCK(avg),min + tJIT(duty),min
max
tCK(avg),max+tJIT(per),max
tCH(avg),max x tCK(avg),max + tJIT(duty),max tCL(avg),max x tCK(avg),max + tJIT(duty),max
Units
ps ps ps
Example: For DDR2-1066, tCH(abs),min = ( 0.48 x 1875 ps ) - 75 ps = 825 ps
32. tHP is the minimum of the absolute half period of the actual input clock. tHP is an input parameter but not an input specification parameter. It is used in conjunction with tQHS to derive the DRAM output timing tQH.
The value to be used for tQH calculation is determined by the following equation; tHP = Min ( tCH(abs), tCL(abs) ), where, tCH(abs) is the minimum of the actual instantaneous clock HIGH time; tCL(abs) is the minimum of the actual instantaneous clock LOW time;
Rev. 1.0 / Aug 2009
60
Release H5PS1G83EFR Series
33. tQHS accounts for: 1) The pulse duration distortion of on-chip clock circuits, which represents how well the actual tHP at the input is transferred to the output; and 2) The worst case push-out of DQS on one transition followed by the worst case pull-in of DQ on the next transition, both of which are independent of each other, due to data pin skew, output pattern effects, and p-channel to n-channel variation of the output drivers 34. tQH = tHP - tQHS, where: tHP is the minimum of the absolute half period of the actual input clock; and tQHS is the specification value under the max column. {The less half-pulse width distortion present, the larger the tQH value is; and the larger the valid data eye will be.} Examples: 1) If the system provides tHP of 1315 ps into a DDR2-1066 SDRAM, the DRAM provides tQH of 575 ps minimum. 2) If the system provides tHP of 900 ps into a DDR2-1066 SDRAM, the DRAM provides tQH of 650 ps minimum. 35. When the device is operated with input clock jitter, this parameter needs to be derated by the actual tERR(6-10per) of the input clock. (output deratings are relative to the SDRAM input clock.) For example, if the measured jitter into a DDR2-1066 SDRAM has tERR(6-10per),min = - 202 ps and tERR(610per),max = + 223 ps, then tDQSCK,min(derated) = tDQSCK,min - tERR(6-10per),max = - 300 ps - 223 ps = - 523 ps and tDQSCK,max(derated) = tDQSCK,max - tERR(6-10per),min = 300 ps + 202 ps = + 502 ps. Similarly, tLZ(DQ) for DDR2-1066 derates to tLZ(DQ),min(derated) = - 700 ps - 223 ps = - 923 ps and tLZ(DQ),max(derated) = 350 ps + 202 ps = + 552 ps. (Caution on the min/max usage!) 36. When the device is operated with input clock jitter, this parameter needs to be derated by the actual tJIT(per) of the input clock. (output deratings are relative to the SDRAM input clock.) For example, if the measured jitter into a DDR2-1066 SDRAM has tJIT(per),min = - 72 ps and tJIT(per),max = + 63 ps, then tRPRE,min(derated) = tRPRE,min + tJIT(per),min = 0.9 x tCK(avg) - 72 ps = + 1615.5 ps and tRPRE,max(derated) = tRPRE,max + tJIT(per),max = 1.1 x tCK(avg) + 63 ps = + 2125.5 ps. (Caution on the min/max usage!)
37. When the device is operated with input clock jitter, this parameter needs to be derated by the actual tJIT(duty) of
the input clock. (output deratings are relative to the SDRAM input clock.) For example, if the measured jitter into a DDR2-1066 SDRAM has tJIT(duty),min = - 72 ps and tJIT(duty),max = + 63 ps, then tRPST,min(derated) = tRPST,min + tJIT(duty),min = 0.4 x tCK(avg) - 72 ps = + 678 ps and tRPST,max(derated) = tRPST,max + tJIT(duty),max = 0.6 x tCK(avg) + 63 ps = + 1188 ps. (Caution on the min/max usage!)
Rev. 1.0 / Aug 2009
61
Release H5PS1G83EFR Series
38 When the device is operated with input clock jitter, this parameter needs to be derated by { - tJIT(duty),max tERR(6-10per),max } and { - tJIT(duty),min - tERR(6-10per),min } of the actual input clock. (output deratings are relative to the SDRAM input clock.) For example, if the measured jitter into a DDR2-1066 SDRAM has tERR(6-10per),min = - 202 ps, tERR(6-10per),max = + 223 ps, tJIT(duty),min = - 66 ps and tJIT(duty),max = + 74 ps, then tAOF,min(derated) = tAOF,min + { tJIT(duty),max - tERR(6-10per),max } = - 350 ps + { - 74 ps - 223 ps} = - 647 ps and tAOF,max(derated) = tAOF,max + { - tJIT(duty),min - tERR(6-10per),min } = 950 ps + { 66 ps + 202 ps } = + 1218 ps. (Caution on the min/max usage!) 39. For tAOFD of DDR2-1066, the 1/2 clock of nCK in the 2.5 x nCK assumes a tCH(avg), average input clock HIGH pulse width of 0.5 relative to tCK(avg). tAOF,min and tAOF,max should each be derated by the same amount as the actual amount of tCH(avg) offset present at the DRAM input with respect to 0.5. For example, if an input clock has a worst case tCH(avg) of 0.48, the tAOF,min should be derated by subtracting 0.02 x tCK(avg) from it, whereas if an input clock has a worst case tCH(avg) of 0.52, the tAOF,max should be derated by adding 0.02 x tCK(avg) to it. Therefore, we have; tAOF,min(derated) = tAC,min - [0.5 - Min(0.5, tCH(avg),min)] x tCK(avg) tAOF,max(derated) = tAC,max + 0.6 + [Max(0.5, tCH(avg),max) - 0.5] x tCK(avg) or tAOF,min(derated) = Min(tAC,min, tAC,min - [0.5 - tCH(avg),min] x tCK(avg)) tAOF,max(derated) = 0.6 + Max(tAC,max, tAC,max + [tCH(avg),max - 0.5] x tCK(avg)) where tCH(avg),min and tCH(avg),max are the minimum and maximum of tCH(avg) actually measured at the DRAM input balls. Note that these deratings are in addition to the tAOF derating per input clock jitter, i.e. tJIT(duty) and tERR(6-10per). However tAC values used in the equations shown above are from the timing parameter table and are not derated. Thus the final derated values for tAOF are; tAOF,min(derated_final) = tAOF,min(derated) + { - tJIT(duty),max - tERR(6-10per),max } tAOF,max(derated_final) = tAOF,max(derated) + { - tJIT(duty),min - tERR(6-10per),min }
Rev. 1.0 / Aug 2009
62
Release H5PS1G83EFR Series
5. Package Dimension
Package Dimension(x8)
60Ball Fine Pitch Ball Grid Array Outline
8.00 ± 0.10
A1 BALL MARK
11.40 ± 0.10
< Top View>
< SIDE View>
0.15 ± 0.05
2-R0.13MAX
0.80 X 8 = 6.40 2.10 ± 0.10
987 321
1.10 ± 0.10 0.34 ± 0.05
A1 BALL MARK
A B C D E F G H J K L
60X Φ 0.45 ± 0 .05
1.60 1.60
0.80
< Bottom View>
Note: All dimensions are in millimeters.
Rev. 1.0 / Aug 2009
0.80
63