CT05 Series Current Sense Transformer
FEATURES
-Full Selection of Turns Ratios -Primary Current (Ip) Rated for 25A -Frequency Range up to 500kHz -Compact Package -Pcs/Tray: -Trays/Box: -Pcs/Box:
PACKAGING
108 12 1296
APPLICATIONS
-DC/DC Converters -AC/DC Converters
Mechanical
17.6 MAX
Dimensions in mm
Footprint
15.3 MAX
2 7.5 3 12.5
Schematic
33 Pri. Pri. 55
Pin 1&2: sq. 0.5 Pin 3&5: dia. 1.2
22 Sec. Sec. 11
CT05-XXX YYWW
12.0 MAX
5.0
5 1 15.0 4
3.0 +/- 0.5 1 5 3 1 5 3
TOP VIEW
Electrical Specifications
Part Number Turns Ratio (Np:Ns) Sec. Ls1 (mH, min.) Sec. DCR (Ω, max.) ET5 (V-mS max.) Hi-Pot
CT05-050 CT05-100 CT05-200 CT05-500 CT05-1000
1:50 1:100 1:200 1:500 1:1000
4.7 18.0 76.0 470 1900
0.50 2.0 4.5 16.0 50.0
175 350 700 1750 3500
4,000 4,000 4,000 4,000 4,000
1. Tested @ 10kHz, 0.1Vrms -1000 tested @ 1kHz, 0.1Vrms 2. Electrical specifications at 25ºC. 3. Operating temperature range: -40ºC to +130ºC. 4. Meets UL 94V-0. 5. ET rating is based on a bipolar waveform
Output Voltage and ET Rating Formulas
Rb (Ω): Terminating Resistance F (HZ): Freq Es (V): Ouptut Voltage ET rating is based on a bipolar waveform
Es=Ip*Rb/Ns ET=Es*1/2F
Specifications subject to change without notice.
800.729.2099 tel
www.icecomponents.com
(10/10) CT05-1
很抱歉,暂时无法提供与“CT05-100”相匹配的价格&库存,您可以联系我们找货
免费人工找货